Moisture Analyzer
Filter
Showing 601–630 of 671 results
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP320 |
| Price | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP330 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP330 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP330 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Model | TP3301 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | HJ 637–2018 |
| Measurement Principle | Infrared Spectrophotometry (Triple-Wavenumber Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹) |
| Sample Preparation | Tetrachloroethylene Extraction + Magnesium Silicate Adsorption |
| Output | Total Extractable Hydrocarbons, Petroleum Hydrocarbons, and Animal/Vegetable Oils (by difference) |
| Operational Mode | Standalone with Onboard Data Processing |
| Calibration | Reference Coefficient-Based (No Calibration Curve Required) |
| Wavenumber Accuracy | < 1 cm⁻¹ (Secant-Mode Scanning) |
| Optical System | Integrated Beam Path with Pulsed IR Source, Active Narrowband Filtering, and Digital Lock-in Amplification |
| Zero Adjustment | Real-time Auto-zero During Source Off-Cycle |
| Display & Interface | Chinese GUI, Touchscreen or Keypad Navigation |
| Data Handling | Onboard Storage, Statistical Analysis, Spectrum Visualization, Thermal Printing |
| Brand | TimePower |
|---|---|
| Model | TP350 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Measurement Principle | Clark-type Membrane Electrode (Galvanic) |
| Display | 128×64 LCD, Chinese Interface |
| Measurement Ranges | 0.0–100 µg/L, 100–1000 µg/L, 1.00–20.00 mg/L (auto-ranging) |
| Resolution | 0.1 µg/L (0–100 µg/L), 1.0 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–45 °C |
| Ambient Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Electrode Type | Galvanic DO sensor with Pt cathode and Pb/Al anode, PTFE/PE hydrophobic membrane |
| Built-in Temp Sensor | Pt1000 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| IP Rating | IP65 |
| Battery Life | Up to 8 hours continuous operation (internal rechargeable battery) |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| A/D Converter | 24-bit |
| Circuit Architecture | High-integration SMT design with embedded MCU |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | TP350 |
| Measurement Principle | Clark-type Membrane Electrode (Galvanic or Polarographic, Configurable) |
| Detection Range | 0.0–100 μg/L, 100–1000 μg/L, 1.00–20.00 mg/L (Auto-ranging) |
| Resolution | 0.1 μg/L (≤100 μg/L), 1.0 μg/L (100–1000 μg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation | Pt1000 sensor, 0–60.0 °C |
| Sample Temp. Range | 5–45 °C |
| Operating Ambient | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| Battery Life | Up to 8 hours continuous operation (internal rechargeable battery) |
| Enclosure Rating | IP65 |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| Electrode Configuration | Integrated galvanic DO sensor with PTFE/PE composite membrane, Pt cathode, Pb/Al anode, aqueous electrolyte |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Co., Ltd. |
| Model | TP526 |
| Test Range | Ambient Temperature to –60 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD |
| Cooling Method | Semiconductor-based Peltier |
| Printer | Thermal, 36-character Chinese/English support |
| Ambient Operating Conditions | 10–40 °C, 30–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 475 × 360 × 495 mm |
| Weight | 21.3 kg |
| Compliance | Designed per GB/T 510 (Petroleum Products—Determination of Cloud Point) and GB/T 3535 (Petroleum Products—Determination of Pour Point) |
| Brand | Timepower |
|---|---|
| Model | TP526 |
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Co., Ltd. |
| Test Range | Ambient Temperature to –60 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD |
| Cooling Method | Semiconductor-based Peltier Cooling |
| Printer | Thermal, 36-character Chinese/English alphanumeric output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 475 × 360 × 495 mm |
| Weight | 21.3 kg |
| Operating Environment | 10–40 °C, 30–80% RH |
| Compliance | Designed per GB/T 510, GB/T 3535, ASTM D97, ASTM D2500, ISO 3016, ISO 2084 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 3 µg – 100 mg |
| Measurement Accuracy | ±0.3% (for samples >1000 µg water) / ±3 µg (for samples 10–1000 µg water) |
| Resolution | 0.1 µg |
| Titration Control Precision | 0.1 µg |
| Minimum Dispensing Increment | 1/1000 |
| Electrolysis Current Range | 0–400 mA |
| Power Supply | AC 220 V ±25 V, 50 Hz ±2.5 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 128×64 dot-matrix LCD |
| Standby Power Consumption | 4 W |
| Dimensions (W×D×H) | 325×245×180 mm |
| Weight | 4.14 kg |
| Compliance Standards | GB/T 1600, GB 7600, GB/T 6283, GB/T 11133, SH/T 0246, SH/T 0255 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Pricing | Available Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Application | Universal Coulometric Moisture Analyzer for Liquids, Solids, and Gases |
| Measurement Principle | Coulometric Karl Fischer Titration (ASTM D6304, ISO 12937, USP <921>, GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255) |
| Display | 128×64 Graphic LCD |
| Data Storage | 256 Records with Timestamp (10-Year Non-Volatile Retention) |
| Resolution | 0.1 µg H₂O |
| Measurement Range | 3 µg – 100 mg H₂O |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Electrolysis Current | 0–400 mA |
| Max. Electrolysis Rate | 2.4 mg H₂O/min |
| Stirring Speed | 10 Adjustable Levels |
| Electrolysis Gain | 10 Adjustable Levels |
| Environmental Operating Conditions | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Compliance | GLP-ready architecture with audit-trail-capable data logging, RS232 interface for external data export and LIMS integration |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP553 |
| Titration Method | Coulometric (Karl Fischer) |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 3 µg – 100 mg |
| Accuracy | ≤0.3% (for samples >1 mg) |
| Minimum Sample Injection Volume | 0.5 µL |
| Titration Control Precision | 0.1 µg |
| Electrolysis Current Range | 0–400 mA |
| Max. Electrolysis Rate | 2.4 mg/min |
| Operating Temperature | 20–30 °C |
| Relative Humidity Limit | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Resolution | 0.1 µg H₂O |
| Moisture Range | 1 ppm to 100% w/w |
| Accuracy | ≤0.3% (relative) |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Precision | ±20% for 3 µg H₂O |
| Compliance Standards | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Water Content Range | 1 ppm to 100% (w/w) |
| Measurement Accuracy | ≤0.3% (for samples ≥1000 µg H₂O) |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Detection Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg H₂O |
| Accuracy Specification | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% at ≥100 µg (excluding sampling error) |
| Display | Chinese LCD |
| Printer | Thermal, 36-character Chinese/ASCII support |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <40 W |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Co., Ltd. |
| Model | TP653 |
| Titration Method | Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 3 µg – 100 mg (H₂O) |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Minimum Dispensing Increment | 1/2000 |
| Titration Control Precision | 3 µg – 100 mg (H₂O) |
| Electrolysis Current | 0–400 mA |
| Display | Chinese LCD (not applicable for international UI) |
| Printer | Thermal, 36-character, Chinese character support (not exported) |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <40 W |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg H₂O |
| Titration Control Precision | 0.1 µg |
| Minimum Dispensing Increment | 1/2000 |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Interface | RS-232 for balance & PC connectivity |
| Printer | Integrated thermal printer |
| Operating Environment | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max Power Consumption | ≤40 W |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Principle | Coulometric titration (Karl Fischer) |
| Resolution | ±0.1 µA |
| Moisture Range | 1 ppm to 100% water content |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | 0.1 µA |
| Compliance Standards | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Microprocessor | 32-bit embedded MCU with real-time OS |
| Electrolysis Cell Design | Hermetically sealed, low-drift moisture cell with rapid equilibration |
| User Interface | Dual-mode (capacitive touchscreen + tactile membrane keys) |
| Connectivity | RS-232 for analytical balance integration |
| Method Storage | Up to 12 pre-programmed analysis methods, with 6 user-customizable slots |
| Data Logging | Timestamped measurement records with real-time electrolysis current curve display |
| Auxiliary Functions | Automatic reagent dispensing, waste drainage, background compensation, dual-circuit balanced titration control |
| Brand | TimePower |
|---|---|
| Model | TP653 |
| Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±3 µg (for 3 µg–1 mg), ±0.3% (for >1 mg, excluding sample introduction error) |
| Electrolysis Current | 0–400 mA (auto-controlled) |
| Display | 5.6-inch color TFT touchscreen LCD |
| Data Interface | RS-232 for balance & PC connectivity |
| Printer | Built-in thermal printer |
| Operating Environment | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤40 W |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Compliance | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Application Scope | Liquids, solids, and gases across petroleum, power, pharmaceutical, chemical, agrochemical, and food industries |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Water Content Range | 3 µg – 100 mg (H₂O) |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Minimum Dispensing Volume | 1 µL |
| Resolution | 0.1 µg H₂O |
| Display | Backlit LCD with Chinese interface |
| Printer | Thermal printer (36-character Chinese/ASCII support) |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Power | AC 220 V ±10%, 50 Hz ±10%, <40 W |
| Operating Temperature | 5–40 °C |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Coulometric (Electrolytic Iodine Generation) |
| Moisture Measurement Range | 3 µg – 100 mg H₂O |
| Measurement Accuracy | ±20% at 3 µg H₂O |
| Minimum Dispensing Volume | 1 µL |
| Resolution | 0.1 µg H₂O |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions (W×D×H) | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Environmental Operating Conditions | 20–30 °C, ≤85% RH |
| Compliance Standards | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automated Coulometric Titration |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 3 µg – 100 mg (H₂O) |
| Accuracy | ±3 µg (for 3–1,000 µg), ±0.3% (for >1 mg, excluding sample weighing error) |
| Minimum Dispensing Increment | 1 µL |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Interface | RS-232 for balance & PC connectivity |
| Printer | Integrated thermal printer |
| Operating Environment | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions (W×D×H) | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic Coulometric Titration |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 3 µg – 100 mg (H₂O) |
| Accuracy | < 0.3% RSD |
| Minimum Dispensing Increment | 1/2000 |
| Titration Control Precision | ±3 µg for 3–1000 µg |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Operating Temperature | 20–30 °C |
| Relative Humidity Limit | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions (W×D×H) | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | TimePower |
|---|---|
| Model | TP653 |
| Type | Coulometric Karl Fischer Titrator |
| Measurement Principle | Coulometric Titration (Karl Fischer) |
| Water Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±1% at 100 µg, ±0.5% above 100 µg (excluding sample handling error) |
| Electrolysis Current | 0–400 mA |
| Display | Backlit Chinese LCD |
| Data Storage | Internal non-volatile memory |
| Printer | Thermal printer (36-character Chinese/ASCII output) |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <200 W |
| Dimensions (W×D×H) | 310 × 315 × 215 mm |
| Weight | 3.5 kg |
| Enclosure | Corrosion-resistant engineering plastic |
| Compliance | GB/T 1600, GB 7600, GB/T 683, GB/T 11133, SH/T 0246, SH/T 0255 |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TX-350 |
| Measurement Range | 3–35% w/w |
| Accuracy | ≤ ±0.5% (within primary moisture range) |
| Repeatability | ≤ 0.2% |
| Measurement Time | ≤ 10 s |
| Net Weight | 750 g |
| Power Supply | Dual-mode AC/DC |
| Features | Auto-zeroing, temperature compensation, automatic shut-off, built-in weighing sensor, bulk density conversion, multi-point calibration capability |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | 3051T |
| Power Supply | DC 8.4 V Li-ion Battery (10 h continuous operation) |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity Range | 0–100 % RH (non-condensing) |
| CO₂ Measurement Range | 0–5000 ppm |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Accuracy | ±3 ppm |
| Temperature Range | −20–80 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Humidity Range | 0–100 % RH |
| Humidity Resolution | 0.1 % RH |
| Humidity Accuracy | ≤ ±1.8 % RH |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| PAR Resolution | 1 µmol·m⁻²·s⁻¹ |
| PAR Accuracy | < ±5 µmol·m⁻²·s⁻¹ |
| Spectral Response | 400–700 nm |
| Flow Rate Range | 0–1.5 L·min⁻¹ |
| Flow Resolution | 0.01 L·min⁻¹ |
| Flow Accuracy | ±2 % |
| Chamber Volume | 1 L (standard) |
| Chamber Material | Outer shell — UPVC |
| Display | 256 × 160 dot-matrix LCD (Chinese interface) |
| Data Storage | 2 GB SD card (≥1,000,000 records) |
| Communication | USB data export to PC for post-processing |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LDS-1H / LDS-1S |
| Measurement Range | 3–35% w.b. |
| Accuracy | ≤ ±0.5% (within primary moisture range) |
| Repeatability | ≤ 0.2% |
| Measurement Time | ≤ 10 s |
| Sample Weight | 150 g (fixed-weight mode, exceptions apply) |
| Temperature Compensation | Automatic |
| Operating Ambient | 0–40 °C |
| Net Weight | 860 g |
| Power Supply | 4 × AA alkaline batteries |
| Calibration | Floating three-point calibration (pre-loaded cultivar-specific curves for common grains and vegetable seeds) |
| Auto-shutdown | After 3 minutes of inactivity |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TC-MSUAV Series |
| Pricing | Upon Request |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TZS-EC W-G |
| Price | USD 2,350 (approx.) |
| Brand | TopCloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | TP-DGP (Multispectral) |
| Flight Endurance | >40 min |
| Max Horizontal Speed | 21 m/s |
| Max Wind Resistance | 12 m/s |
| RTK Positioning Accuracy | 1 cm + 1 ppm (horizontal), 1.5 cm + 1 ppm (vertical) |
| Visible Light Camera | 20 MP, 4/3" CMOS, 24 mm equiv. f/2.8 lens, 84° FOV, JPEG/DNG output |
| Multispectral Sensor | 5 MP, 1/2.8" CMOS, 25 mm equiv. lens, 73.91° diagonal FOV, spectral bands: G (560±16 nm), R (650±16 nm), RE (730±16 nm), NIR (860±26 nm), TIFF output, gain 1x–32x |
| Real-time Video Transmission | 1080p/30fps |
| Operating Temperature | −10°C to +40°C |