Moisture Analyzer
Filter
Showing 271–300 of 676 results
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP-304 |
| Price | Upon Request |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Model | HT-350 |
| Measurement Principle | High-frequency electromagnetic wave (radio frequency, 1–10 MHz) |
| Moisture Range | 0–80% w/w |
| Accuracy | ±(0.5% of reading + 1%) |
| Resolution | 0.1% |
| Response Time | 1 second |
| Operating Temperature | −10 °C to 50 °C |
| Operating Humidity | 35–85% RH |
| Display | 4-digit LCD with backlight |
| Power Supply | 4 × AAA batteries |
| Dimensions (main unit) | 140 mm × 60 mm × 24 mm |
| Sensor Probe Length | Standard 235 mm (custom lengths available) |
| Net Weight | ~120 g |
| Compliance | Designed for industrial QC environments |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SFY-20 |
| Price | USD 1,890 (FOB Guangdong) |
| Weighing Range | 0–90 g |
| Moisture Measurement Range | 0.01–100% |
| Minimum Readability | 0.001 g |
| Sample Mass | 0.5–90 g |
| Heating Temperature Range | Ambient to 205 °C |
| Heating Method | Variable Hybrid Halogen Heating |
| Auto Temperature Compensation | ±15 °C |
| Moisture Resolution | 0.01% |
| Display Modes | 7 Parameters (Moisture %, Initial/Final Mass, Test Duration, Initial/Final Temp, Endpoint Detection Time) |
| Interface | Dual RS-232 (Printer & PC) |
| Dimensions (W×D×H) | 380 × 205 × 325 mm |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Net Weight | 3.7 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-344 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer Accessory |
| Measurement Resolution | 0.005 mL |
| Moisture Range | 10 ppm to 100% H₂O |
| Burette Accuracy (10 mL) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Titration Control Precision | ±0.5% |
| Heating Method | Surround-type heating of titration cell |
| Temperature Range | Ambient to 60 °C |
| Temperature Stability | ±3 °C |
| Power Supply | AC 100 V, 50/60 Hz, ~55 W |
| Dimensions (W×D×H) | 100 × 150 × 133 mm |
| Weight | 1.8 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512 |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512S |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Volume | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz, ~600 W |
| Heating Temperature Range | 50–1000 °C |
| Evaporation Tube Material | Quartz |
| Sample Boat Material | Quartz |
| Sample Capacity | 10 mL |
| Dimensions | 835(W) × 340(D) × 345(H) mm |
| Weight | 18 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-513 |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg to 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Heating Temperature Range | Ambient to 200 °C |
| Evaporator Capacity | 100 mL |
| Evaporator Material | Transparent Heated Borosilicate Glass |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 210 × 330 mm |
| Weight | 6 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-611 |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric or Coulometric Karl Fischer Moisture Analyzer Compatible |
| Measurement Resolution | 0.1 µg |
| Moisture Content Range | 1 ppm to 100% |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 0–16 mL |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHK-501 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Sample Capacity | 24 positions |
| Heating Temperature Range | Ambient to 300 °C (individually programmable per sample) |
| Heater Type | Quartz Infrared Heater |
| Power Supply | AC 100–120 / 220–240 V, 50/60 Hz, ~100 W |
| Dimensions (W×D×H) | 452 × 400 × 362 mm |
| Weight | 20 kg |
| Origin | Japan |
|---|---|
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Method | Coulometric Karl Fischer Titration |
| Endpoint Detection | Constant-Current Polarity Detection |
| Electrolysis Control | Pulse-Modulated Current Control |
| Max Electrolysis Current | 400 mA |
| Max Water Titration Rate | 2.1 mg H₂O/min |
| Background Correction | Automatic μg/sec Drift Compensation |
| Water Measurement Range | 10 μg – 100 mg H₂O |
| Repeatability | ±5 μg (for 10–1000 μg), RSD ≤0.5% (≥1 mg H₂O) |
| Sensitivity | 0.1 μg H₂O |
| Display | 2-line × 20-character LCD (showing moisture content, reagent concentration, titration rate, background drift, elapsed time, and calculation mode) |
| Connectivity Options | RS-232 interface for printer, PC, or analytical balance |
| End Signal | Visual alert + audible timer alarm |
| Delayed Titration | Programmable start delay (time-based) |
| Calculation Modes | %, ppm, mg/g (M/W) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH, non-condensing |
| Power Supply | AC 230–240 V, 50/60 Hz, 30 VA |
| Dimensions (H×W×D) | 200 × 280 × 180 mm |
| Net Weight | 4.5 kg (main unit), 6.3 kg (unit + power supply) |
| Origin | Japan |
|---|---|
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Coulometric (Electrolytic) KF Titration |
| Endpoint Detection | Constant-Current Polarity Detection |
| Maximum Electrolysis Current | 400 mA |
| Maximum Titration Rate | 2.1 mg H₂O/min |
| Background Correction | Automatic Drift Compensation (µg/s) |
| Measurement Range | 10 µg – 100 mg H₂O |
| Repeatability | ±5 µg (for 10–1000 µg), RSD ≤ 0.5% (≥1 mg H₂O) |
| Sensitivity | 0.1 µg H₂O |
| Display | 2-line × 20-character LCD |
| Environmental Operating Conditions | 5–40 °C, ≤80% RH (non-condensing) |
| Power Supply | AC 230–240 V, 50/60 Hz, 30 VA |
| Dimensions (W×D×H) | 280 × 180 × 200 mm |
| Net Weight | 4.5 kg (main unit), 6.3 kg (unit + power supply) |
| Interface Options | RS-232 for printer, PC, or analytical balance |
| Calculation Modes | %, ppm, mg/g (M/W), auto-unit switching (>1000 ppm → %) |
| Delayed Titration | Programmable start time |
| End Signal | On-screen message + audible alert |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Model | MKC-710 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Moisture Range | 1 µg – 300 mg H₂O (up to 1000 mg with extended range) |
| Precision | RSD < 0.3% (n = 10, per certified reference materials and ASTM E203) |
| Electrode System | Dual-platinum detection electrodes with AC polarization |
| Cell Type | Membrane-separated or membrane-free electrolytic cell |
| Resolution | 0.1 µg H₂O |
| Max. Electrolysis Rate | 2.6 mg H₂O/min |
| Display | 8.4″ color LCD (800 × 600), multilingual UI (English, Japanese, Chinese, Korean, Russian, Spanish, German, French) |
| Data Storage | 500 sample results (MKC-710M), GLP-compliant audit trail, operator/group management, reagent lifetime tracking, scheduled performance verification |
| Interface | RS-232C × 4, USB × 1, SS-BUS, APBLAN |
| Environmental Operating Range | 5–35 °C, ≤85% RH |
| Power | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~30 W (main unit), ~7 W (printer) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKC-710B |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (equivalent to 100 ppb – 100% w/w) |
| Accuracy | ≤ 0.3% RSD (n = 10, per ASTM E1064 & GB/T 26793-2011) |
| Minimum Dosing Resolution | 0.1 µg |
| Titration Control Precision | ±0.3% of set current pulse duration |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKC-710D |
| Titration Mode | Fully Automated Coulometric Titration |
| Method Type | Coulometric Karl Fischer Titration |
| Measurement Resolution | 0.1 µg H₂O |
| Moisture Content Range | 1 ppm – 100% w/w |
| Accuracy | ≤0.3% RSD (n=10) |
| Minimum Electrolytic Water Generation Rate | 2.6 mg H₂O/min |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Coulometric + Volumetric) |
| Measurement Resolution | 0.1 µg |
| Moisture Range | 1 ppm to 100% H₂O |
| Accuracy | < 0.3% RSD (n = 10) |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.1 µg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage | Internal memory (500 samples for MKC-710M |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKC-710M |
| Titration Mode | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (up to 1000 mg with optional configuration) |
| Accuracy | ≤0.3% RSD (n=10, certified reference materials) |
| Minimum Dosing Resolution | 0.1 µg |
| Repeatability | <0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| GLP Compliance | Operator logging, reagent tracking, performance verification, time-stamped audit trail |
| Communication Interfaces | RS-232C, USB (host/device), LAN |
| Expandability | Up to 4 titration units |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (extendable to 1000 mg) |
| Accuracy | ≤0.3% RSD (n=10) |
| Minimum Electrolytic Generation Rate | 2.6 mg H₂O/min |
| Repeatability | <0.3% RSD |
| Cell Configuration | Membrane-type or Membrane-free Coulometric Titration Cell |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Compliance | GLP-ready with operator/group logging, reagent tracking, performance verification, and time-stamped audit trail |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKH-710M |
| Titration Mode | Fully Automated |
| Instrument Type | Dual-Mode Karl Fischer Moisture Analyzer (Volumetric & Coulometric) |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 500 mg H₂O |
| Accuracy | ±0.3% RSD (n=10) |
| Minimum Dispensing Increment | 0.1 µg |
| Repeatability | ±0.3% RSD |
| Burette Control Accuracy | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 measurement records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | MKV-710 |
| Pricing | Available Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Model | MKV-710B |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Titration Accuracy (10 mL burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710D |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Resolution | 0.005 mL |
| Moisture Range | 1 ppm – 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | ±0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710M |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1/20,000 |
| Moisture Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Repeatability | ±0.005 mL |
| Burette Capacity | 10 mL |
| Titration Control Precision | 0.005 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Repeatability | ±0.005 mL |
| Burette Unit | EBU-710-KF |
| Titration Control Precision | 0.015 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 Sample Records |
| GLP Compliance | Operator Logging, Reagent Tracking, Performance Verification, Time-Stamped Audit Trail |
| Connectivity | RS-232C, USB (Host & Device), SS-BUS (APB) |
| Optional Accessories | ADP-611 Coulometric/KF Oven, Solvent Exchange Unit, Dual Burette Module |
| Brand | KETT |
|---|---|
| Origin | Japan |
| Model | PB-1D3 |
| Measurement Principle | Electrical Resistance |
| Sample Types | Paddy Rice, Brown Rice, Milled Rice, Barley, Wheat, Rye |
| Moisture Range | Paddy Rice: 11–35% |
| Brown/Milled Rice | 11–20% |
| Barley/Wheat | 10–40% |
| Rye | 10–20% |
| Accuracy | ±0.1% (at ≤20%), ±0.5% vs. 105°C Oven-Drying Reference Method |
| Display | 128×64 Dot-Matrix LCD, Resolution: 0.1% |
| Temperature Compensation | Automatic Thermistor-Based Correction |
| Power Supply | AC 100 V (50/60 Hz) or Four 1.5 V AA Batteries |
| Dimensions & Weight | 250 × 240 × 125 mm, 3.5 kg |
| Accessories | Sample Pan, 15% Calibration Standard, Measuring Spoon, Hand Grinder Handle, Cleaning Brush, Power Cord, Instruction Manual |
| Brand | KETT |
|---|---|
| Origin | Japan |
| Model | PM650 |
| Measurement Principle | High-Frequency Capacitance (50 MHz) |
| Sample Type | Cereals & Seeds |
| Moisture Range | 1–40% w/w (varies by grain species) |
| Sample Volume | 240 mL |
| Operating Temperature | 0–40 °C |
| Moisture Accuracy | ±0.5% (vs. ASTM D4940 or ISO 712 dry-weight reference method, for samples ≤20% moisture) |
| Built-in Compensation | Automatic mass correction via integrated precision balance (0.01 g resolution), temperature compensation via thermistor |
| Calibration Offset Range | −9.9 to +9.9 units (user-adjustable) |
| Additional Outputs | Bulk Density (g/L), arithmetic mean of up to 9 readings |
| Display | LCD numeric readout |
| Power | Four 1.5 V AA alkaline batteries |
| Dimensions (W×D×H) | 125 × 205 × 215 mm |
| Weight | 1.3 kg |
| Brand | KETT |
|---|---|
| Origin | Japan |
| Model | PQ520 |
| Measurement Principle | Capacitance (with resistive correction) |
| Sample Types | Polished rice, brown rice, paddy rice, barley, wheat, rye kernels |
| Moisture Range | Polished/brown rice: 11–20% w.b. |
| Paddy rice | 11–35% w.b. |
| Barley/wheat | 10–40% w.b. |
| Rye kernels | 10–35% w.b. |
| Accuracy | ±0.5% (for samples ≤20% moisture, w.b.) |
| Measurement Time | <40 seconds per 100 grains (brown rice, average moisture display) |
| Temperature Compensation | Integrated thermistor-based automatic ambient temperature correction |
| Grain Count Setting | 10–1000 grains (user-selectable) |
| Display | Fluorescent segment display |
| Output Interfaces | RS-232C (printer), USB (PC data export) |
| Operating Environment | 5–40°C, ≤85% RH |
| Power Supply | AC 100 V, 50/60 Hz |
| Dimensions & Weight | 320 × 254 × 382 mm (W×D×H), 9.0 kg |
| Brand | KETT |
|---|---|
| Origin | Japan |
| Model | RN-300 |
| Heating Method | Infrared |
| Sample Type | Brown Rice & Polished Rice (polished rice analysis requires optional accessories) |
| Image Sensor | Color CCD Camera |
| Light Source | White Cold-Cathode Fluorescent Lamp |
| Maximum Sample Capacity | 1,148 grains per measurement |
| Analysis Time | Approx. 24 seconds |
| Display | Grain-by-grain classification, count, percentage composition (by number and mass), length/width/projection area, typicality index, embryo retention rate (0 / ½ / full), crack detection |
| Power Supply | AC 100 V ±10%, 50/60 Hz |
| Dimensions (Transport) | 580 × 230 × 420 mm |
| Dimensions (Operation) | 840 × 580 × 115 mm |
| Weight | ~12 kg |
| Brand | KEWLAB |
|---|---|
| Model | MA113TA |
| Heating Source | Halogen Lamp |
| Capacity | 110 g |
| Readability | 0.001 g / 0.01% |
| Repeatability | ±0.002 g |
| Temperature Range | 40–230 °C |
| Timer Range | 1–99 min |
| Operating Environment | 5–35 °C |
| Interface | RS232, RJ45 Ethernet |
| Display | Large Capacitive Touchscreen |
| Power Supply | 220 V / 50 Hz |
| Dimensions (L×W×H) | 215 × 195 × 415 mm |
| Sample Pan Material | Precision Cast Aluminum |
| Chamber Material | Multi-layer Stainless Steel |
| Cooling | Dual Fan System |
| Connectivity | Wired (TA series) |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | KLY-2 |
| Pricing | Upon Request |
| Product Type | Portable Dew Point Meter |
| Measurement Range | –80 to +20 °C dew point (approx. 0.5–23,632 µL/L H₂O) |
| Accuracy | ≤±0.5 °C (at factory calibration) |
| Response Time | <30 s (63%), <60 s (90%) for rise at DP < –40 °C |
| Output Signal | 4–20 mA analog |
| Operating Media Conditions | Gas temperature < +60 °C, pressure < 2 MPa, flow rate 200 mL/min |
| Dimensions | 260 mm × 170 mm × 300 mm (W×H×D) |
| Brand | Koyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic Electrolytic Titration |
| Sample Form | Liquid |
| Measurement Range | 3 ppm – 99.99% H₂O |
| Detection Sensitivity | 0.01 µg H₂O |
| Resolution | 0.1 ppm (typical for coulometric systems) |
| Endpoint Detection | Potentiometric (dual-current mode) |
| Power Consumption | 50 W |
| Dimensions | 280 × 280 × 160 mm |
| Compliance | GB/T 7600–1987, SH/T 0246–1992, SH/T 0255–1992 |
| Interface | USB 2.0 (PC-controlled) |
| Electrolysis Cell | Custom Fritted-Glass Electrode Assembly (membrane-free design) |