| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | TSF-50A-5 |
| Heating Source | Halogen Lamp |
| Display | 4.3-inch Capacitive Touchscreen LCD |
| Readability | 0.01% / 1 mg |
| Compliance | GB/T 29249–2012 (Electronic Moisture Analyzer Based on Drying Method) |
| Interface | RS232 for Printer & PC Connectivity |
| Data Output | Real-time Drying Curve, Auto-finalization, Lock-on-Completion |
| Brand | York |
|---|---|
| Model | DPT-70 |
| Type | Portable Dew Point Meter |
| Principle | Capacitive Polymer Sensor |
| Measurement Range | -70 to +30 °C (Dew Point) |
| Resolution | 0.01 °C (DP) |
| Accuracy | ±2.0 °C (DP) |
| Response Time (T90) | <120 s |
| Operating Temperature | -10 to +60 °C |
| Sample Pressure Range | 0–20 bar (absolute) |
| Power Supply | Rechargeable Li-ion Battery (220 VAC charger included) |
| Weight | 0.7 kg |
| Dimensions (Handheld Unit) | 250 × 70 × 25 mm |
| Display | Backlit LCD with Multi-parameter Readout |
| Data Logging | Internal storage with USB export to Excel-compatible CSV format |
| Brand | York Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DPSS-6100 |
| Product Type | Online Dew Point Analyzer Sampling System |
| Measurement Principle | Capacitive Polymer Sensor-Based Dew Point Detection |
| Pressure Rating | Up to 20 MPa (for integrated pressure regulator) |
| Filtration Precision | 2 µm (stainless steel sintered filter element) |
| Flow Control Range | 0–2 L/min (adjustable via precision needle valve) |
| Compliance Standards | GB 50029-2014 (Compressed Air Station Design Code), GB 50093-2013 (Code for Construction and Quality Acceptance of Automation Instrumentation Engineering), GB 50030-2013 (Oxygen Station Design Code) |
| Brand | York Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YKDC220 |
| Application | Laboratory-grade dew point calibration system |
| Measurement Principle | Chilled-mirror hygrometry |
| Operating Temperature | 20–25 °C |
| Accuracy | ±0.1 °C (dew point) |
| Repeatability | ±0.1 °C (dew point) |
| Dry Gas Generator | GS-1000 with PSA drying |
| Minimum Achievable Dew Point | ≤ −80 °C |
| Input Pressure | ≥ 0.8 MPa |
| Output Pressure Range | 0–0.3 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (W×D×H) | 485 × 500 × 260 mm |
| Weight | 20 kg |
| Interface | RS485 |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DM9200 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled Mirror Condensation |
| Operating Temperature Range | −30 to +90 °C |
| Accuracy | ±0.15 °C |
| Repeatability | ±0.05 °C |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Condensation |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±0.1 °C (dew point) |
| Repeatability | ±0.05 °C (dew point) |
| Display | High-Resolution Capacitive Touch LCD |
| User Interface | Graphical, Multilingual (English/Chinese), Step-by-Step Guidance |
| Mirror Control | Digital Fuzzy Logic with Auto-Balance Algorithm |
| Mirror Maintenance | Integrated Mirror Inspection and Automated Cleaning Sequence |
| Diagnostics | Real-Time Self-Diagnostic Engine with Fault Classification |
| Communication Interfaces | RS-485, USB 2.0 |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | -70 °C to +20 °C |
| Resolution | 0.01 °C |
| Response Time | ≤60 s (for 10 °C step change) |
| Mirror Material | Chromium-Plated Copper |
| Flow Rate Range | 0–2 L/min (accuracy ±5%) |
| Pressure Sensor Range | 0–200 kPa (abs), accuracy ±0.25% FS |
| Remote Temperature Sensor | 4-wire PT100, accuracy ±0.1 °C, cable length <2 m |
| Power Supply | 80–264 VAC, 47–63 Hz, 400 W |
| Analog Outputs | 4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V (3-channel, user-configurable) |
| Alarm Outputs | 2 programmable SPDT relays (250 VAC/5 A, 30 VDC/5 A, resistive load) |
| Communication | USB, RS-485, Modbus RTU protocol |
| Data Storage | SD card (FAT32, up to 32 GB) |
| Display | 7" LCD touch screen, 1024×600 RGB WVGA, 16:9 aspect ratio |
| Supported Units | °C, °F, ppmv, ppmw, %RH, g/kg, mg/m³ |
| Sample Gas Temp | -20 °C to +40 °C |
| Sample Gas Pressure | 0–200 kPa (abs) |
| Sample Flow Rate | 0.3–1 L/min |
| Environmental Humidity Limit | <80% RH |
| Storage Temperature | -20 °C to +50 °C (optimal at 20 °C) |
| Dimensions | 190 mm (H) × 483 mm (W) × 498 mm (D) |
| Weight | 15 kg |
| Gas Inlet Fitting | 1/4" stainless steel compression fitting |
| Enclosure Material | Aluminum alloy |
| Gas Path Materials | 316L stainless steel |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | 10–35 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | −90 to +20 °C |
| Resolution | 0.01 °C |
| Response Time | ≤60 s (for ±10 °C step change) |
| Mirror Material | Chromium-Plated Copper |
| Flow Rate Range | 0–2 L/min (±5% FS) |
| Pressure Range | 0–200 kPa (abs), ±0.25% FS |
| Remote Temperature Sensor | 4-wire PT100, ±0.1 °C |
| Display | 9.7" LCD, 1024×768 RGB, 4:3 aspect ratio |
| Analog Outputs | 3-channel configurable (4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V) |
| Digital Interfaces | USB, RS-485 (Modbus RTU) |
| Data Storage | SD Card (FAT32, up to 32 GB) |
| Enclosure | 6U 19″ rack-mountable aluminum chassis (278 × 483 × 578 mm, 40 kg) |
| Gas Inlet/Outlet | 1/4″ VCR (in), 1/4″ stainless steel compression (out) |
| Wetted Materials | 316L stainless steel, chromium-plated copper mirror |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | -10 °C to +35 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | -95 °C to +20 °C (at 20 °C ambient) |
| Display | 9.7" TFT LCD Touchscreen |
| Resolution | 0.01 °C |
| Output Options | 4–20 mA, 0–10 V, RS-485 (Modbus RTU), USB |
| Data Storage | SD Card (FAT32, up to 32 GB) |
| Sample Flow Rate | 0.3–1 L/min |
| Sample Pressure | 0–200 kPa (abs) |
| Sample Temperature | -20 °C to +40 °C |
| Mirror Material | Rhodium-plated Copper |
| Enclosure | Aluminum Alloy |
| Dimensions | 278 mm (H) × 483 mm (W) × 578 mm (D) |
| Weight | 40 kg |
| Power Supply | 198–254 VAC, 47–63 Hz, 1000 W |
| Brand | Yuntang |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-NIR-T |
| Heating Method | Infrared |
| Measurement Range | 0–100% w/w |
| Accuracy | ±0.2% w/w (subject to material composition variation) |
| Light Source | Imported high-efficiency NIR source |
| Filter Cycle | 1–60 s |
| Illumination Diameter | 60–75 mm |
| Working Height | 350 mm + 100 mm tolerance |
| Measurement Channels | 50 |
| Probe Window Material | High-borosilicate quartz glass |
| Operating Environment | −40 °C to +70 °C, 5–95% RH (non-condensing) |
| Power Supply | 220 VAC / 50 Hz |
| Communication Interfaces | RS485, 4–20 mA analog output, RS232, Ethernet (LAN), LoRa wireless |
| Enclosure Rating | IP65 |
| Display | Integrated industrial touchscreen |
| Probe Housing | High-strength aluminum alloy |
| Brand | ZRTB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZB-305A |
| Maximum Capacity | 120 g |
| Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Heating Source | Halogen Lamp (Room Temp–180 °C, 1 °C Increments) |
| Drying Modes | Standard / Rapid / Gentle |
| Termination Modes | Auto-Stop / Timed Stop / Manual Stop |
| Weighing Sensor | HBM (Germany) |
| Processor | ARM (UK) |
| Calibration Weight | 100 g |
| Pan Diameter | φ110 mm |
| Interface | RS232 |
| Dimensions (L×W×H) | 330 × 205 × 165 mm |
| Application | Multi-industry moisture determination in plastics, polymers, pharmaceuticals, food, and chemicals |