Moisture Analyzer
Filter
Showing 631–660 of 671 results
| Brand | TOYO Corporation (Japan) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Water Balance Measurement System |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC7100 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror–Calibrated Semiconductor Sensor |
| Operating Temperature Range | –30 °C to +60 °C |
| Accuracy (Dew Point) | ±0.5 °C |
| Repeatability | ±0.5 °C |
| RH Accuracy | ±3 % RH |
| RH Resolution | 0.1 % RH |
| RH Range | 0–100 % RH |
| Air Temperature (Ta) Range | –20 °C to +80 °C |
| Surface Temperature (Ts) Range | –30 °C to +60 °C |
| Ta/Ts Resolution | 0.1 °C / 0.1 °F |
| Data Series Capacity | 8 independent test series |
| Recommended Operating Ambient | 20 °C to 60 °C |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | TRQ-600 |
| Type | Online Dew Point Meter |
| Principle | Ceramic Capacitive Sensor (Not Semiconductor — Corrected per Technical Specification) |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 °C dp (at +20 to -60 °C) |
| Repeatability | 0.5 °C dp |
| Response Time (T95) | 5 min (dry-to-wet) |
| Measurement Range | -100 to +20 °C dew point |
| Moisture Output Range | 0–3000 ppmv |
| Analog Output | 4–20 mA (2-wire, current loop) |
| Supply Voltage | 12–28 V DC |
| Max Load Resistance | 250 Ω @ 12 V |
| Max Current Consumption | 23 mA |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRQ-600 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Ceramic Capacitive Sensor (Hygrometric Impedance) |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±1 °C dew point (+20 °C to −60 °C) / ±2 °C dew point (−60 °C to −100 °C) |
| Repeatability | 0.5 °C dew point |
| Response Time (T95) | 5 min (dry-to-wet transition) |
| Dew Point Range | −100 °C to +20 °C |
| Output Signal | 4–20 mA (2-wire, loop-powered) |
| Supply Voltage | 12–28 V DC |
| Max. Load Resistance | 250 Ω @ 12 V / 500 Ω @ 24 V |
| Current Consumption | ≤23 mA |
| Moisture Output Options | dew point (°C), ppmv H₂O (0–3000 ppmv) |
| Sample Compatibility | Oil-tolerant ceramic sensing element with integrated hydrophobic particulate and molecular sieve filtration |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | KF-4 |
| Titration Method | Fully Automatic Volumetric Titration |
| Principle | Volumetric Karl Fischer Titration |
| Moisture Range | 10 ppm to 100% H₂O |
| Resolution | 0.1 µL (volumetric) |
| Accuracy | ±0.01% (relative) |
| Minimum Dispensing Volume | 0.005 mL |
| Titration Precision | ±0.1% RSD |
| Stirring Control | Multi-stage Adjustable |
| Display | Large LCD with Real-time Process Monitoring |
| Data Storage | Internal Memory + RS-232/USB Output |
| Dimensions (W×D×H) | 260 × 330 × 170 mm |
| Weight | 3.0 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | Designed for GLP-compliant environments |
| Brand | Vympel (Russia) |
|---|---|
| Origin | Russia |
| Model | Hygrovision BL |
| Type | Portable Chilled-Mirror Dew Point Analyzer |
| Principle | Chilled-Mirror Condensation |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±0.5 °C (Class B) |
| Water Dew Point Range | −60 °C to ambient |
| Hydrocarbon Dew Point Range | −30 °C to ambient |
| Sample Flow Rate | 0.5–2 L/min |
| Max Sample Pressure | 160 bar (230 bar optional) |
| Data Storage | Internal memory for ≥5 years of measurements |
| Battery Life | Up to 4 h |
| IP Rating | IP67 |
| ATEX/IECEx Certification | II 2G Ex IIB T5 Gb |
| Dimensions (H×W×D) | 202 × 153 × 257 mm (excl. microscope) |
| Weight | ~7.5 kg |
| Brand | VYMPEL (Russia) |
|---|---|
| Origin | Russia |
| Model | Hygrovision min SL |
| Type | Portable Chilled-Mirror Dew Point Analyzer |
| Measurement Principle | Chilled-mirror (optical condensation detection) |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Range | -50 °C to ambient temperature |
| Sample Flow Rate | 0.2–2 L/min |
| Max Sample Pressure | 230 bar |
| Battery Life | ≥12 h (up to 20 h) |
| IP Rating | IP67 |
| ATEX/IECEx Certification | Ex db ib IIB+H2 T5 |
| Dimensions (W×D×H) | 253 × 120 × 110 mm (excl. microscope) |
| Weight | ~4 kg |
| Standards Compliance | ISO 6327, ISO 11150 (TR), ISO 12148 (TR), ASTM D1142, DIN 51781, GB/T 17283-2014, GB/T 27895-2011 |
| Brand | VYMPEL (Russia) |
|---|---|
| Origin | Russia |
| Model | Hygrovision mini |
| Type | Portable dew point analyzer |
| Principle | Chilled-mirror hygrometry |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1 °C |
| Measurement Range | −50 °C to ambient temperature |
| Resolution | 0.1 °C |
| Sample Flow Rate | 0.2–2 L/min |
| Sample Pressure | up to 100 bar |
| Battery Life | ≥12 h (up to 20 h) |
| IP Rating | IP67 |
| ATEX/IECEx Certification | Ex db ib IIB+H2 T5 |
| Dimensions (W×D×H) | 253 × 120 × 110 mm (excl. microscope) |
| Weight | ~4 kg |
| Standards Compliance | ISO 6327, ISO 11150, ISO/TR 12148, ASTM D1142, DIN 51781, GB/T 17283–2014, GB/T 27895–2011 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AFT-350 |
| Product Type | In-Line Dew Point Sensor |
| Operating Principle | Chilled-Mirror-Based Electrothermal Dew Point Measurement |
| Operating Temperature Range (Electronics) | −20 °C to +60 °C |
| Accuracy | ±3.5% of reading at 20 vol% H₂O |
| Humidity Range | 20–100 vol% (at process temperatures >100 °C) |
| Response Time (20→100 vol%) | ≤10 s |
| Response Time (100→20 vol%) | ≤60 s |
| Warm-up Time | ~10 min |
| Temperature Range (Probe Tip) | 0–350 °C |
| Temp. Accuracy | ±0.5 °C ± 0.75% of measured value |
| Recommended Gas Velocity | ≤0.5 m/s |
| Output Signals | Dual 4–20 mA (humidity + temperature, load ≤600 Ω each) |
| Power Supply | 12 VDC @ 8.5 A |
| Probe Dimensions | Humidity Sensing Element: 10 mm L × 3 mm Ø |
| Temperature Sensing Element | 50 mm L × 4 mm Ø |
| Housing Material | Engineering Plastic |
| Humidity Sensor Material | Nickel-Plated Copper |
| Temperature Sensor Material | AISI 316 (1.4301 / V4A) |
| IP Rating | IP67 (sensing head), IP65 (housing) |
| Brand | XENTAUR |
|---|---|
| Origin | USA |
| Model | XPDM |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Aluminum Oxide Capacitive Sensor |
| Operating Temperature Range (Electronics) | –10 °C to 50 °C |
| Sensor Operating Temperature Range | –30 °C to 50 °C |
| Dew Point Measurement Range | –100 °C to 20 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.5 °C |
| Resolution | 0.1 °C |
| Response Time (63%) | 90 s |
| Response Time (90%) | 450 s |
| Operating Pressure | 200 kPa (standard), up to 690 kPa (absolute) |
| Display | 3½-digit LCD with backlight |
| Power Supply | 9 V alkaline battery or 15–25 V DC external source |
| Enclosure Material | Anodized aluminum |
| Sampling Flow Rate | 100 mL/min |
| Pressure Correction | Programmable |
| Electrical Isolation | Sensor, housing, and power supply isolated |
| Storage Temperature | –20 °C to 60 °C |
| Sensor Storage Condition | Maintained at ~ –80 °C dew point in dry chamber when idle |
| (在此处输出精准翻译� | �纯英文产品名称。极其重要:仅输出一行名称,严禁输出备选名、严禁换行重复、严禁包含任何中文字符) |
|---|---|
| [Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XPDM |
| Pricing | Available Upon Request] |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ST-1513A |
| Price Range | USD 1,400 – 7,000 |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | ST-1523 |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 1 µg to 200 mg |
| Resolution | 0.1 µg |
| Accuracy | ±3 µg for 5–1000 µg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-100A-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Time Setting | 1–99 min (1 min increments) |
| Temperature Range | 50–160 °C |
| End Point Control | Timer-based or Auto-termination |
| Display | Backlit dot-matrix LCD showing moisture %, solids %, weight, elapsed time |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Analytical Instrument |
| Model | DSH-100A-1 |
| Pricing | Upon Request |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Duration | 1–99 min (adjustable in 1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Display Content | Moisture %, Solid %, Sample Weight (g), Elapsed Time (min:s), Date & Time |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Communication Interface | RS232 |
| Endpoint Detection Modes | Timed Mode, Auto-Termination Mode |
| Heating Profile | Standard Ramp |
| Max Capacity | 100 g |
|---|---|
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Plate Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-10A |
| Heating Method | Halogen Lamp |
| Display | High-Resolution Backlit Dot-Matrix LCD |
| Interface | RS-232C |
| Features | Automatic Tare, Zero Drift Compensation, Real-Time Dryness Monitoring |
| Compliance | Designed for ISO 5725 (accuracy & reproducibility), ASTM E1447 (moisture in solids), and USP <921> (Loss on Drying) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | DSH-10A |
| Maximum Capacity | 10 g |
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Temperature Range | 50–180 °C |
| Heating Time Programmable | 1–99 min (1-min increments) |
| Heating Source | Halogen lamp |
| Pan Diameter | 100 mm |
| Display | Backlit dot-matrix LCD |
| Interface | RS-232C |
| End-point Detection | Timed & Automatic |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Compliance | ISO 5725 (accuracy & precision), ASTM E1447, USP <921>, GLP-ready data logging |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSH-10A |
| Max Capacity | 10 g |
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Display | Backlit Dot-Matrix LCD |
| Interface | RS232 |
| End-Point Modes | Timed & Auto-Termination |
| Data Output | Moisture %, Solid %, Weight (g), Elapsed Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | DSH-10A |
| Pricing | Upon Request |
| Weighing Range | 0–10 g |
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Time Setting | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Display Content | Moisture %, Solid %, Weight (g), Elapsed Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Communication Interface | RS232 |
| Endpoint Detection Modes | Timed Mode, Automatic Mode |
| Heating Profile | Standard Ramp |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 Halogen Moisture Analyzer |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| End Point Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight (g), Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Endpoint Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight, Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Interface | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSH-50A-1 |
| Weighing Range | 0–50 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Time Range | 1–99 min (adjustable in 1-min increments) |
| Temperature Control Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Display | Backlit Dot-Matrix LCD |
| Interface | RS232 |
| Endpoint Modes | Timed & Automatic |
| Displayed Parameters | Moisture %, Solid %, Weight (g), Elapsed Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Max Capacity | 50 g |
|---|---|
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timer-Controlled & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Max Capacity | 50 g |
|---|---|
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Weight (g), Elapsed Time, Date |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-5 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–50 g |
| Readability | 5 mg |
| Temperature Range | 50–160 °C |
| Heating Time | 1–99 min (1-min increments) |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Repeatability (3 g sample) | ±0.3% |
| Display | Backlit dot-matrix LCD |
| Interface | RS232 |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| End-point Modes | Timed & Automatic |
| Heating Profile | Standard |
| Display Outputs | Moisture %, Solid %, Sample Weight, Elapsed Time |
| Max Capacity | 50 g |
|---|---|
| Readability | 5 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yoke Instrument Co., Ltd. |
| Model | TSF-100A-1 |
| Heating Method | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Temperature Range | 50–160 °C (1 °C increments) |
| Drying Time | 1–99 min (1 min increments) |
| Drying Modes | Standard, Rapid |
| Display | 4.3" TFT capacitive touchscreen |
| Interface | USB (printer & PC connectivity) |
| Pan Diameter | 80 mm |
| Dimensions (L×W×H) | 340 × 210 × 180 mm |
| Net Weight | 3.6 kg |
| Operating Environment | 10–30 °C, ≤75% RH |
| Compliance | GB/T 29249–2012 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yoke Instrument Co., Ltd. |
| Model | TSF-10A |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–10 g |
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Temperature Range | 50–160 °C (adjustable in 1 °C increments) |
| Drying Time | 1–99 min (adjustable in 1 min increments) |
| Drying Modes | Standard, Rapid |
| Display | 4.3″ TFT LCD touchscreen |
| Communication | USB interface |
| Pan Diameter | 80 mm |
| Dimensions (L×W×H) | 340 × 210 × 180 mm |
| Net Weight | 3.6 kg |
| Operating Environment | 10–30 °C, ≤75% RH |
| Compliance | GB/T 29249–2012 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yoke Instrument Co., Ltd. |
| Model | TSF-50A-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–50 g |
| Readability | 1 mg |
| Moisture Readability | 0.01% |
| Repeatability (3 g sample) | ±0.2% |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Temperature Range | 50–160 °C (1 °C increments) |
| Drying Time | 1–99 min (1 min increments) |
| Drying Modes | Standard & Rapid |
| Auto-termination | Yes |
| Display | 4.3" TFT LCD touchscreen |
| Interface | USB |
| Pan Diameter | 80 mm |
| Dimensions (L×W×H) | 340 × 210 × 180 mm |
| Net Weight | 3.6 kg |
| Operating Environment | 10–30 °C, ≤75% RH |
| Compliance | GB/T 29249–2012 |