BrandQL
OriginJiangsu, China
Instrument TypeBenchtop
Excitation ModeSpark
DetectorHigh-Performance CMOS Array (CCD-compatible architecture)
Focal Length401 mm
Grating Groove Density2400 lines/mm
Wavelength Range140–680 nm
Number of Simultaneous Channels60
Optical SystemPaschen-Runge Mount with Vacuum-Enclosed Roland Circle
Light SourceDigital Plasma Spark Source with High-Energy Pre-Ignition (HEPS)
Discharge Frequency100–1000 Hz
Max Discharge Current500 A
Vacuum SystemMulti-Stage Oil-Backstream Prevention with Differential Pressure Valve & In-Line Oil Trap
Analysis Gap4 mm
Electrode MaterialTungsten Jet Electrode
Argon ConsumptionOptimized via Integrated Pneumatic Module
Data InterfaceGigabit Ethernet (TCP/IP)
Dimensions (W×D×H)780 × 565 × 360 mm
Weight78 kg
Typical Analysis Time~20 s per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin / QL
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQL-5800E
PriceUSD 23,500 (FOB Nanjing)
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeHigh-Performance CCD Array
Focal Length401 mm
Grating Groove Density2400 lines/mm
Wavelength Range140–680 nm
Number of Spectral Channels60
Optical SystemPaschen-Runge Mount with Vacuum-Enclosed Roland Circle
Light SourceDigital Plasma Spark Source with High-Energy Pre-Ignition (HEPS)
Discharge Frequency100–1000 Hz
Power SupplyAC 220 V, 50/60 Hz, 1000 W
Dimensions (W×D×H)780 × 565 × 360 mm
Weight78 kg
Typical Analysis Time~20 s per sample
Electrode MaterialTungsten Jet Electrode
Inter-Electrode Gap4 mm
Vacuum SystemMulti-Stage Oil-Backstream Prevention with Differential Pressure Valve and In-Line Oil Trap
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandQilin / QL
OriginJiangsu, China
Instrument TypeFloor-standing
Excitation MethodSpark
DetectorCCD Array
Focal Length400 mm
Groove Density2400 lines/mm
Wavelength Range130–900 nm
Number of Channels60]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin / QL
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelQL-5800E
Instrument TypeBenchtop
Excitation MethodSpark
Detector TypeCCD Array
Focal Length401 mm
Grating Groove Density2400 lines/mm
Wavelength Range140–680 nm
Number of Detection Channels60
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin / QL
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelQL-5800E
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeHigh-Performance CMOS Array (CCD-compatible architecture)
Focal Length401 mm
Grating Groove Density2400 lines/mm
Wavelength Range140–680 nm
Number of Detection Channels60
Power SupplyAC 220 V, 50/60 Hz, 1000 W
Dimensions (W×D×H)780 × 565 × 360 mm
Weight78 kg
Typical Analysis Time~20 s per sample
Inter-electrode Gap4 mm
Electrode MaterialTungsten
Vacuum SystemIntegrated oil-free vacuum with differential pressure valve and multi-stage oil-trap protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin / QL
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelQL-5800A
Instrument TypeFloor-standing
Excitation MethodSpark Discharge
Detector TypePhotomultiplier Tube (PMT)
Focal Length750 mm
Grating Groove Density2400 lines/mm
Wavelength Range130–600 nm
Number of Analytical Channels32
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin (QL)
ModelQL-5800E
Instrument TypeBenchtop OES
Excitation SourceSpark Discharge
DetectorCCD Array
Focal Length401 mm
Grating Groove Density2400 lines/mm
Wavelength Range140–680 nm
Number of Detection Channels60
Optical SystemPaschen–Runge Mount with Vacuum-Enclosed Roland Circle
Base Materials SupportedFe, Cu, Al, Ni, Co, Mg, Ti, Zn, Pb, Sn, Ag
Analysis Time~20 s per sample
Dimensions780 × 565 × 360 mm
Weight78 kg
Power SupplyAC 220 V, 50/60 Hz, 1000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin
ModelQL-5800A
Instrument TypeFloor-standing
Excitation MethodSpark discharge
Detector TypePhotomultiplier Tube (PMT)
Focal Length750 mm
Grating Groove Density2400 lines/mm
Wavelength Range130–600 nm
Number of Channels32
Operating EnvironmentArgon-purged optical chamber
Optical StabilityThermostatically controlled at 38 °C ±0.2 °C
Dimensions (L×W×H)1120 × 750 × 920 mm
Net Weight266 kg