Nanjing Qilin Scientific Instrument Group Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin (QL)
OriginJiangsu, China
ModelQL-TS-6
Measurement PrincipleThermal Analysis (Solidification Curve Monitoring via Immersion Thermocouple)
Measurement Time≤90 s per sample
CE Range3.2–4.8 wt%, ±0.08 wt% accuracy
C Range2.8–4.2 wt%, ±0.04 wt% accuracy
Si Range0.9–3.0 wt%, ±0.04 wt% accuracy
Data Storage Capacity3,000 measurements with timestamped sequence
Output InterfaceUSB flash drive export optional
ComplianceDesigned for foundry floor deployment under ISO 9001 and ASTM E1157 (Standard Practice for Sampling and Testing Cast Iron) environments
Operating EnvironmentIndustrial-grade embedded PC with fanless motherboard, 17″ ruggedized LCD display, EMI-hardened signal acquisition architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin / QL
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelQL-TS-6
Price RangeUSD 2,800 – 7,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin (QL)
OriginJiangsu, China
ModelQL-HW2000B
Measurement PrincipleInfrared Absorption Spectroscopy
Heating System2.5 kVA High-Frequency Induction Furnace (18–20 MHz)
Carbon Range0.00001–10.0000 wt% (extendable to 99.999 wt%)
Sulfur Range0.00001–0.5000 wt% (extendable to 99.999 wt%)
Sensitivity0.1 ppm (minimum display resolution)
PrecisionCarbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0%
Analysis Time25–60 s (user-adjustable)
ComplianceGB/T 20123–2006, ISO 15350:2000
Sample Weighing Accuracy0.0001 g
Detector TypeHigh-Stability Pyroelectric Infrared Detector with Narrow-Band Interference Filters
Gas ControlPrecision Mass Flow Controllers + Airtac (Taiwan) Solenoid Valves (rated for ≥100,000 cycles)
Optical DriveAerospace-Grade Synchronous Motor (MTBF > 100,000 h)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin / QL
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQL-BS3B
PriceUSD 1,380 (FOB Nanjing)
Measurement PrinciplePhotometric Colorimetry with Cold Light Sources
Elements MeasuredSi, Mn, P, Ni, Cr, Cu, Rare Earths, Mg, Fe, Al, V, W, Ti
Typical Range (w/w)Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99%
Detection MethodDual-beam photometry using imported silicon photodiodes
CalibrationAutomatic zero & full-scale self-calibration
Curve Storage15 user-programmable calibration curves
Input InterfaceTouch-sensitive membrane keypad with audible feedback
Sample PreparationExternal fusion (crucible-based), valve-free and tubing-free design
Optical SourceInterchangeable cold-light sources for spectral adaptability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQL
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelHW2000B
PriceUSD 13,800 (FOB Nanjing)
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating System2.5 kVA High-Frequency Induction Furnace (18–20 MHz)
Carbon Range0.00001–10.0000 wt% (extendable to 99.999 wt%)
Sulfur Range0.00001–0.5000 wt% (extendable to 99.999 wt%)
Sensitivity0.1 ppm (minimum display resolution)
PrecisionCarbon RSD ≤ 0.5%
Analysis Time25–60 s (user-adjustable)
ComplianceGB/T 20123–2006, ISO 15350:2000
Weighing Accuracy0.0001 g (external analytical balance required)
Optical DetectionHigh-stability pyroelectric IR detectors with narrow-band interference filters
Gas HandlingPrecision mass flow control
Mechanical DriveAerospace-grade synchronous motor in IR absorption cell (MTBF > 100,000 h)
CompensationReal-time temperature, pressure, and flow compensation algorithms
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin (QL)
ModelBS1000G
OriginJiangsu, China
TypeBenchtop Photometric Elemental Analyzer
Optical SystemAdjustable-Wavelength Self-Collimating Diffraction Grating (Right-Exit)
Wavelength Accuracy±3 nm
Measurable Elements (typical)Mn (0.10–65.00 wt%), Si (0.10–75.00 wt%), P (0.005–1.00 wt%), Cu (0.02–85.00 wt%), Cr (0.01–45.00 wt%), Ni (0.01–50.00 wt%), Mo (0.101–6.00 wt%), Mg (0.010–0.100 wt%), Rare Earths (0.01–0.100 wt%)
Analytical MethodPhotometric Colorimetry with Computer-Controlled Wavelength Selection
Measurement Time per Sample≤5 s
Weighing Device0.0001 g Precision Electronic Balance (1/10,000 g resolution)
ComplianceGB/T 223 series (Chinese national standards for metallurgical analysis)
Operating Environment10–30 °C, RH <75%
Data OutputIntegrated thermal printer (Chinese-language interface), PC-based data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin
ModelTS-3
OriginJiangsu, China
Measurement Time240 s
CE Range3.2–4.8 wt% (±0.1%)
C Range2.8–4.2 wt% (±0.05%)
Si Range0.9–3.0 wt% (±0.08%)
Display Height50 mm
Temperature Compensation0–40 °C
Cup TypesS, R, B, K
ComplianceEN 50081-2, EN 50082-2
Temperature UnitSelectable (°C/°F)
Status IndicatorsGreen (Ready), Yellow (Measuring), Red (Complete)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQilin (QL)
ModelQL-BS1000
OriginJiangsu, China
Wavelength Range400–800 nm (continuously adjustable)
Absorbance Range0–1.999 A
Concentration Display Range0.000–99.99% (auto-ranging)
Wavelength Accuracy±3 nm
Data StorageOnboard EEPROM (retains data for ≥10 years without power)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Power Consumption≤45 W
Net Weight≤15 kg
Display1-inch numeric LED display
CalibrationAuto-zero and full-scale calibration using cold light source and imported photodetectors
Curve StorageUp to 9 pre-programmed calibration curves
Sample HandlingExternal dissolution
Optical SystemAdjustable-wavelength monochromatic light source with microprocessor-controlled spectral selection
Show next