| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QL-BS3B |
| Price | USD 1,380 (FOB Nanjing) |
| Measurement Principle | Photometric Colorimetry with Cold Light Sources |
| Elements Measured | Si, Mn, P, Ni, Cr, Cu, Rare Earths, Mg, Fe, Al, V, W, Ti |
| Typical Range (w/w) | Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99% |
| Detection Method | Dual-beam photometry using imported silicon photodiodes |
| Calibration | Automatic zero & full-scale self-calibration |
| Curve Storage | 15 user-programmable calibration curves |
| Input Interface | Touch-sensitive membrane keypad with audible feedback |
| Sample Preparation | External fusion (crucible-based), valve-free and tubing-free design |
| Optical Source | Interchangeable cold-light sources for spectral adaptability |
| Brand | Qilin (QL) |
|---|---|
| Model | BS1000G |
| Origin | Jiangsu, China |
| Type | Benchtop Photometric Elemental Analyzer |
| Optical System | Adjustable-Wavelength Self-Collimating Diffraction Grating (Right-Exit) |
| Wavelength Accuracy | ±3 nm |
| Measurable Elements (typical) | Mn (0.10–65.00 wt%), Si (0.10–75.00 wt%), P (0.005–1.00 wt%), Cu (0.02–85.00 wt%), Cr (0.01–45.00 wt%), Ni (0.01–50.00 wt%), Mo (0.101–6.00 wt%), Mg (0.010–0.100 wt%), Rare Earths (0.01–0.100 wt%) |
| Analytical Method | Photometric Colorimetry with Computer-Controlled Wavelength Selection |
| Measurement Time per Sample | ≤5 s |
| Weighing Device | 0.0001 g Precision Electronic Balance (1/10,000 g resolution) |
| Compliance | GB/T 223 series (Chinese national standards for metallurgical analysis) |
| Operating Environment | 10–30 °C, RH <75% |
| Data Output | Integrated thermal printer (Chinese-language interface), PC-based data logging |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-BS1000 |
| Origin | Jiangsu, China |
| Wavelength Range | 400–800 nm (continuously adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Wavelength Accuracy | ±3 nm |
| Data Storage | Onboard EEPROM (retains data for ≥10 years without power) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | ≤45 W |
| Net Weight | ≤15 kg |
| Display | 1-inch numeric LED display |
| Calibration | Auto-zero and full-scale calibration using cold light source and imported photodetectors |
| Curve Storage | Up to 9 pre-programmed calibration curves |
| Sample Handling | External dissolution |
| Optical System | Adjustable-wavelength monochromatic light source with microprocessor-controlled spectral selection |