Other Common Laboratory Equipment
Filter
Showing 421–450 of 1883 results
| Brand | Edmund Bühler |
|---|---|
| Origin | Germany |
| Model | VIM-Cu Crucible Induction Melting Furnace |
| Maximum Sample Mass | 20 g |
| Maximum Melting Temperature | 1800 °C |
| Ultimate Vacuum | 10⁻³ mbar |
| Pumping Speed (at atmospheric pressure) | 2.5 m³/h |
| Time to Reach 10⁻³ mbar | ~8 min |
| Generator Power | 12 kW |
| Operating Frequency Range | 50–200 kHz |
| Input Voltage | 230 V / 50–60 Hz (1-phase) or 400 V / 50–60 Hz (3-phase) |
| Standard Copper Mold Dimensions (L × W × D) | 50 × 12 × 4.5 mm |
| Sample Cavity Dimensions (L × W × D) | 16 × 12 × 4.5 mm |
| Overall Footprint (W × D × H) | 880 × 900 × 1300 mm |
| Brand | Edmund Optics |
|---|---|
| Origin | USA |
| Model | 226 |
| Diffuser Surface | Frosted White Coating |
| Coating Thickness | 0.45 mm (±0.35 mm, –0.2 mm) |
| Shape Options | Circular or Square |
| Compliance | ISO 10110-7 (Surface Quality), MIL-PRF-13830B (Scratch-Dig) |
| Brand | Edmund Optics |
|---|---|
| Origin | USA |
| Model | 225 |
| Filter Type | Longpass |
| Substrate Material | Optical Glass (UV-Longpass), Optical Polymer (NIR-Longpass) |
| Transmission Range | UV-Blocking / Visible-Transmitting (UV-LP) or Visible-Blocking / NIR-Transmitting (NIR-LP) |
| Available Diameters | Multiple Standard Sizes (e.g., 12.5 mm, 25 mm, 50 mm) |
| Optical Density (OD) @ Blocking Region | ≥4.0 (typical) |
| Surface Quality | 60–40 scratch-dig |
| Clear Aperture | ≥90% of diameter |
| Operating Temperature | –20 °C to +70 °C (glass) |
| Compliance | RoHS 2015/863/EU, REACH SVHC-free |
| Brand | Edmund Optics |
|---|---|
| Model | NT72-375 |
| Dimensions | 12 in × 12 in × 0.007 in |
| Operating Temperature Range | 20–25 °C (68–77 °F) |
| Material | Cholesteric Liquid Crystal Polymer Film |
| Substrate | Polyester (PET) |
| Response Time | < 1 s |
| Reusability | Fully reversible, >10⁴ thermal cycles |
| Storage Stability | 2 years at 25 °C / 50% RH |
| Compliance | RoHS 2 compliant, REACH SVHC-free |
| Brand | CME (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | Electrochemical Cell |
| Pricing | Upon Request |
| Brand | CME (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Classification | Domestic (China) |
| Model | Electrode Holder Stand |
| Pricing | Available Upon Request |
| Construction | Full PTFE + Stainless Steel |
| PTFE Base Plate Dimensions | 150 mm × 120 mm |
| Stainless Steel Support Rod | Ø8 mm × 160 mm |
| Compatible Vessel Capacities | 15 mL, 30 mL, 50 mL, 100 mL, 150 mL, 200 mL, 250 mL, 300 mL |
| Brand | Electrothermal |
|---|---|
| Origin | United Kingdom |
| Model | RS1000 |
| Temperature Range | +5°C to 150°C |
| Stirring Speed | 400–2000 rpm |
| Sample Capacity | 10 positions, 10–30 mL per vial |
| Tube Diameter Compatibility | 24/25 mm (with optional adapters for 11 mm, 16 mm, or 1 mL tubes) |
| Temperature Stability | ±1.0°C |
| Heating Time to Max Temp | ≤15 min |
| Dimensions (D×W×H) | 80 × 150 × 305 mm |
| Weight | 4 kg |
| Power Supply | 230 V / 115 V, 50–60 Hz, 300 W |
| Control Interface | Manual knobs + RS232/RS485 digital port |
| Optional High-Temp Variant | RS1000H (up to 300°C) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PMS |
| Pricing | Upon Request |
| Measurement Principle | Spectroscopic and Mueller Matrix Ellipsometry |
| Environmental Compatibility | Ambient Air, N₂ Atmosphere, Vacuum |
| Sample Environment Interface | Integrated vacuum flange or atmospheric port |
| Optical Range | 193–2500 nm (standard configuration: 380–1000 nm, extendable) |
| Measurement Modes | Variable-angle, Fixed-angle, Normal-incidence (vertical-angle) ellipsometry |
| Mapping Capability | Fully programmable X-Y stage with customizable travel range |
| Sample Size Support | Custom-engineered for large-format substrates (e.g., Gen 2–Gen 8.5 glass panels) |
| Single-Point Acquisition Time | 0.5–5 s (spectroscopic), <1 s (broadband fixed-angle) |
| Output Data | Thickness distribution maps, refractive index (n) & extinction coefficient (k) spatial profiles, layer stack modeling (Cauchy, Tauc-Lorentz, B-spline), real-time delta psi/delta delta contours |
| Software Compliance | Audit-trail enabled, user-level access control, data export in ASTM E2657-compliant CSV/HDF5 formats |
| Regulatory Alignment | Designed to support GLP/GMP-aligned process validation |
| Brand | Ying'an Meicheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Y-I |
| Instrument Type | Plasma-Based Purification System |
| Flow Rate | 1–4 m³/h |
| Purity | 99.9999% (N₂ ≤ 0.2 ppm) |
| Dimensions (W×D×H) | 500 × 500 × 900 mm |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TDK Series |
| Price Range | USD 280 – 14,000 |
| Temperature Range (Refrigerated Models) | 15–70 °C |
| Refrigeration Capability | Down to 20 °C (±0.3 °C stability) |
| Temperature Resolution | 0.1 °C |
| Heating Power | 1000 W (TDK-24R) |
| Tank Capacity | 24 L |
| Internal Dimensions (TDK-24R) | 400 × 200 × 300 mm (L×W×H) |
| External Dimensions (TDK-24R) | 470 × 230 × 810 mm |
| Timer Range | 1–9999 min |
| Power Supply | AC 220 V, 50 Hz |
| Insulation | ≥5 mm mineral wool |
| Construction | 304 stainless steel inner chamber & lid, electrostatically sprayed steel outer casing |
| Optional Accessories | Dry-run protection, auto-refill (external water source required), 30-segment programmable temperature controller, RS485 interface with PC communication software |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC8S-1 |
| Price | Upon Request |
| Microwave Power | 0–1000 W (continuous, linearly adjustable) |
| Microwave Frequency | 2450 MHz ±50 MHz |
| Ultrasonic Power | 50 W |
| Ultrasonic Frequency | 40 kHz |
| Temperature Range | 0–300 °C (contact sensor, ±1 °C accuracy) |
| Reaction Volume | 10–500 mL |
| Cavity Material | Stainless Steel |
| Safety Compliance | Meets GB 10436-2008 (Chinese national standard for microwave leakage) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-10 |
| Oscillation Radius | 1.0 m / 0.6 m |
| Turntable Diameter | 800 mm |
| Nozzle Diameter | Φ0.4 mm |
| Nozzle Spacing | 50 mm |
| Oscillation Angle | ±180°, 120°, quasi-360° |
| Pipe Inner Diameter | Φ15 mm |
| Water Pressure Range | 80–150 kPa (adjustable) |
| Turntable Speed | 1–17 rpm |
| Oscillation & Turntable Drive | Frequency-controlled (inverter-driven, stepless) |
| Construction Material | SUS304 stainless steel (housing and all water-contact components) |
| Power Supply | AC 380 V, 50 Hz |
| Compliance Standard | GB 4208–1993 (IPX1–IPX6 equivalent) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ME-L |
| Pricing | Upon Request |
| Light Source | Deuterium + Halogen Composite Lamp |
| Spectral Range (Standard) | 380–1000 nm (Expandable to 210–1650 nm or 193–2500 nm) |
| Measurement Time per Scan | 1–8 s |
| Thickness Repeatability | ±0.005 nm |
| Absolute Accuracy (Air Reference) | ψ = 45° ± 0.05°, Δ = 0° ± 0.1° |
| Mueller Matrix Diagonal Elements | m<sub>ii</sub> = 1 ± 0.005, Off-Diagonal Elements: m<sub>ij</sub> = 0 ± 0.005 |
| Spot Size | Macro-spot 2–3 mm |
| Angle Range | Auto-adjustable 45–90° |
| Optional Modules | Temperature-Controlled Stage (RT to 600 °C), Mapping Stage (up to 100 × 100 mm), Vacuum Pump, Transmission Adsorption Kit |
| Litron Nano L series Nd | YAG Pulsed Nanosecond Laser System |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Nano L series Nd:YAG |
| Pulse Energy (1064 nm) | 320 mJ |
| Pulse Energy (532 nm) | 180 mJ |
| Pulse Energy (355 nm) | 60 mJ |
| Pulse Energy (266 nm) | 40 mJ |
| Pulse Width (1064 nm) | 10–14 ns |
| Beam Diameter | <6 mm |
| Energy Stability (1064 nm) | ±2.5% RMS |
| Jitter | ≤1.0 ns |
| Repetition Rate | 1–20 Hz |
| Temperature Control Accuracy | ±0.05 °C |
| Cooling Power Capacity | Up to 1200 W |
| Dimensions (Laser Head) | 720 × 136 × 156 mm |
| Dimensions (Power & Cooling Unit) | 435 × 485 × 285 mm |
| Input Power | 220 V AC, 50–60 Hz, 1000 W |
| Brand | Zhongjiaojinyuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CO₂ Integrated Utilization Thermal & Photo-Thermal Catalytic Reaction System (Customizable HP/LP Configuration) |
| Pricing | Available Upon Request |
| Frame Dimensions | 1130 mm × 550 mm × 1340 mm |
| Construction Material | ASTM A240 316L Stainless Steel |
| Thermal Reactor Temp. Range | 0–800 °C |
| Photo-Thermal Reactor Temp. Range | 0–800 °C |
| Max. High-Pressure Operation | < 10 MPa |
| Max. Low-Pressure Operation | < 0.6 MPa |
| Vaporization Zone Temp. | 0–300 °C |
| Tubing Trace Heating | 0–200 °C |
| Liquid Flow Rate | 0.1–5 mL/min |
| Catalyst Bed Volume | < 5 mL |
| Gas Flow Control | Mass Flow Controllers with Gas-Specific Calibration Factors |
| Safety | Dual-stage overpressure relief, real-time overtemperature/overpressure interlock, alarm logging |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ST-20 |
| Pricing | Upon Request |
| Standard Throughput | 20 L/h (adjustable 5–40 L/h) |
| Minimum Batch Volume | 3–5 L |
| Max Sterilization Temperature | 150 °C |
| Holding Time Options | 5 s, 15 s, 30 s (at 20 L/h) |
| Fill Temperature Range | 20–90 °C |
| SIP Capability | Yes |
| CIP Flow Rate | 400 L/h |
| Max System Pressure | 10 bar |
| Power Supply | 3-phase, 380 V, 10 kW |
| Dimensions (UHT Unit) | 1600 H × 1200 L × 950 W mm |
| Aseptic Filling Module (CT-20) | HEPA Filtration Efficiency ≥99.999% @ 0.3 µm |
| Cleanroom Class | ISO Class 5 (Fed. Std. 209E Class 100) |
| CT-20 Dimensions | 2100 H × 850 L × 660 W mm |
| CT-20 Power | Single-phase, 220–240 V, 50 Hz, 0.25 kW |
| Brand | Environmental Express |
|---|---|
| Origin | USA |
| Model | ZHE1000 |
| Sample Capacity | 25 g |
| Extraction Volume | 560 mL |
| Filter Material | Borosilicate Glass |
| Filter Pore Size | 0.7 µm |
| Filter Diameter | 90 mm |
| Housing Material | 316 Stainless Steel |
| Compliance | EPA Method 1311 (TCLP) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | #352 |
| Pricing | Upon Request |
| Brand | ERICHSEN (Germany) |
|---|---|
| Origin | Germany |
| Model | #451 |
| Available Sizes | A4, A5, A6, 430×282 mm, 430×280 mm, 335×225 mm, 437×282 mm, 280×50 mm, 185×105 mm, 185×75 mm |
| Format | Pre-printed standardized opacity test sheets |
| Compliance | Designed for ISO 2814, ASTM D2805, DIN 53162, and EN 971-1 compliant coating evaluation |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | Ecosystem |
| Pricing | Available Upon Request |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Halo Sense Laboratory Air Quality Sensor |
| Detection Targets | VOCs, Acids, Formaldehyde |
| Connectivity | Ethernet + USB + Bluetooth (via eGuard app) |
| Alert Mechanism | Dual-mode visual (RGB status ring) + audible alarm |
| Software Platform | eGuard Cloud & Desktop Application |
| Compliance | CE, RoHS, EN 61000-6-3, EN 61000-6-1 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Mounting | Wall-mounted with IP20 enclosure |
| Operating Environment | 5–40 °C, 20–80% RH non-condensing |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Halo Smart |
| Airflow Capacity | Up to 220 m³/h |
| Filtration Technology | Ionized Cascade (Ion-Enhanced Multi-Stage Adsorption) |
| Power Consumption | 50 W |
| Operating Voltage/Frequency | 100–240 V / 50–60 Hz |
| Weight (incl. filters) | 31 kg |
| Installation | Ceiling-suspended via 4 lifting lugs or wall-mounted using 4 brackets |
| Connectivity | 1 × Ethernet port for e-Guard remote monitoring |
| Sensor Suite | Semiconductor sensor (VOCs), electrochemical sensors (acids, formaldehyde) |
| Control Interface | Visual status indicator (LED beam pulsing), mobile app integration via Erlab Smart platform |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Halo Smart Laboratory Air Purifier |
| Airflow Capacity | Up to 220 m³/h |
| Filtration Type | Multi-stage Filter-Based System |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 50 W |
| Weight (incl. filters) | 31 kg |
| Mounting | Ceiling-suspended via four wire ropes or bracket-mounted |
| Compliance | Designed for ISO 14644-1 Class 5–8 laboratory environments |
| Sensor Types | Semiconductor (VOCs), Electrochemical (acids, formaldehyde) |
| Control Interface | Visual status indicators (LED light patterns), e-Guard remote monitoring software via Ethernet port |
| Operating Modes | Continuous 7×24, Day/Night, Pollution-triggered Auto-Start, Adjustable Fan Speed (Min/Max) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | AB2-S |
| Airflow Velocity (Inflow) | 0.53 m/s (105 fpm) |
| Airflow Velocity (Downflow) | 0.33 m/s (65 fpm) |
| Power Supply | 220–240 V AC, 50/60 Hz, 1-phase |
| Internal Dimensions (W×D×H) | up to 1870 × 585 × 670 mm |
| External Dimensions (W×D×H, with stand) | up to 1950 × 811 × 2171 mm |
| Filtration | ULPA (MPPS ≥ 99.999%) |
| Compliance | CFDA YY 0569-2011, Class II Type B2 |
| Control System | Sentinel Gold microprocessor-based digital panel with RS232 interface |
| Surface Coating | Esco ISOCIDE™ antimicrobial coating |
| Fan System | DC ECM motor with constant airflow compensation |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LVG Series |
| Pricing | Available Upon Request |
| Certifications | EN 12469 Compliant |
| Filtration Efficiency | HEPA H14 (≥99.995% @ 0.3 µm) |
| Cleanroom Class | ISO 3 (Class 1) |
| Airflow Velocity | Adjustable 0.3–0.5 m/s (default 0.45 m/s) |
| Noise Level | ≤54.5 dBA |
| Power Supply | 230 V, 50/60 Hz |
| Motor Type | Brushless DC ECM Fan |
| Energy Savings | Up to 70% vs. AC equivalents |
| Surface Treatment | ISO-SCIDE™ Silver-Ion Antimicrobial Coating |
| Control System | Sentinel Gold Microcontroller |
| Compliance | Tested per EN 12469 for product protection and cross-contamination control |
| Materials | All interior components certified for ISO Class 3 cleanroom use |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCR-3A1, PCR-4A1 |
| Price | Upon Request |
| External Dimensions (L×W×H) | PCR-3A1: 1035 × 617 × 950 mm |
| PCR-4A1 | 1340 × 617 × 950 mm |
| Internal Dimensions (L×W×H) | PCR-3A1: 935 × 538 × 550 mm |
| PCR-4A1 | 1240 × 538 × 550 mm |
| Airflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 230 VAC, 50 Hz |
| Pre-filter & HEPA Filter Efficiency | >99.99% at 0.3 µm |
| HEPA Service Life | ≥3 years (under typical lab conditions) |
| Control System | Esco Sentinel Microprocessor Controller |
| UV Timer & Alarm Functions | Yes |
| UV Lamp & Pre-filter Replacement Alerts | Yes |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | AC2-D |
| Certification | EN 12469 |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 220 V, 50 Hz |
| ULPA Filter Efficiency | ≥99.999% @ 0.3 µm, ≥99.995% @ 0.1 µm |
| Work Surface | Seamless Stainless Steel |
| ISOCIDE™ Antimicrobial Coating | Yes |
| Control System | EscoSentinel Gold Microprocessor-Based Display |
| Connectivity | RS-232 Interface for BMS Integration |
| Available Widths | 1200 mm (4') and 1800 mm (6') |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | AC2-E |
| Certification | EN 12469 compliant |
| Airflow (Inflow) | 0.45 m/s (90 fpm) |
| Airflow (Downflow) | 0.30 m/s (60 fpm) |
| Power Supply | 230 V, 50/60 Hz |
| Filtration | ULPA filter with ≥99.995% efficiency at 0.1 µm |
| Surface Coating | Esco ISOCIDE® antimicrobial coating |
| Construction | Seamless stainless steel work chamber |
| Ergonomic Design | Integrated handrests, sloped front grille, spill-containment work surface |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Certification | EN 12469, IEST-RP-CC001, ISO 5 (Class 100) |
| Filter Efficiency | ULPA ≥99.995% @ 0.1 µm, ≥99% @ 0.3 µm |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 220 V, 50 Hz |
| Construction | Stainless Steel Work Surface, ISOCIDE® Antimicrobial Coating |
| Control System | Sentinel Gold™ Microprocessor-Based Display |
| Connectivity | RS-232 Interface for BMS Integration |
| Noise Level | ≤65 dB(A) |
| Compliance | Meets NSF/ANSI 49, EN 12469, and EU Directive 2014/34/EU (ATEX) for optional UV configurations |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LA2-A |
| Pricing | Available Upon Request |
| External Dimensions (L×W×H) | Varies by variant (LA2-3A to LA2-8A) |
| Internal Work Area Dimensions | 970–2440 mm (L) × 623 mm (W) × 670 mm (H) |
| Inflow Velocity | 0.53 m/s (105 fpm) |
| Downflow Velocity | 0.35–0.33 m/s (70–65 fpm) |
| Power Supply | 220 VAC, 50 Hz |
| Filtration | Dual Minipleat ULPA filters (≥99.999% @ 0.1–0.3 µm) |
| Compliance | NSF/ANSI 49, EN 12469, YY 0569, JIS K 3800 |
| Control System | Sentinel Gold microprocessor-based digital display with RS232 interface |
| Ergonomics | 10° forward tilt, ADA-compliant angled control panel and handrest, seamless stainless steel work surface, ISOCIDE antimicrobial coating |
