| Brand | OHAUS |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CLR-LBLFTS008 |
| Pricing | Upon Request |
| Brand | OMNI International |
|---|---|
| Origin | USA |
| Model | Prep 96 |
| Sample Capacity | 96 samples per run |
| Volume Range | 250 µL – 40 mL (in 5–50 mL tubes) |
| Speed Range | 500–28,000 rpm |
| Motor Configuration | Four 100 W brushless DC motors |
| Tip Compatibility | 7 mm & 12 mm OMNI Tips™ plastic homogenizer probes |
| Motion Profile | Dual-axis oscillatory motion (vertical + horizontal) |
| Noise Level | ≤75 dB(A) |
| Dimensions (W×D×H) | 95.2 cm × 64.8 cm × 72.9 cm (96.5 cm with lid open) |
| Weight | 57 kg |
| Certifications | TÜV, NRTL, CE, UKCA, RCM, KCC, FCC Part 15 |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | OTA4-T20 |
| Price Range | USD 1,400 – 2,800 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optima T100-R |
| Pricing | Available Upon Request |
| Temperature Range | –47 °C to 100 °C (model-dependent) |
| Temperature Stability | ±0.1 °C |
| Dual Heating Power | 2 kW |
| Pump Max Flow Rate | 21 L/min (adjustable) |
| Pump Max Pressure | 460 mbar |
| External Pt1000 Probe Input | Yes |
| Display | Dual—high-brightness LED for setpoint + 2×16-character LCD for menu navigation |
| Preset Temperatures | 3 user-definable |
| Calibration | User-accessible offset adjustment |
| Alarm System | Visual & audible high/low temperature alerts |
| Interface Languages | 5 selectable (English, German, French, Spanish, Italian) |
| Optional Bath Volumes | 5 L, 12 L, or 20 L |
| Drain Port | Included on GP200-R2 through GP200-R5 models |
| Refrigeration Capacity @ 20 °C | 250–1100 W (model-dependent) |
| Refrigeration Capacity @ –10 °C | 140–1050 W (model-dependent) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PlasmaPro 100 Cobra |
| Wafer Capacity | Single-wafer and batch processing up to 200 mm |
| Temperature Range | −150 °C to +400 °C |
| Electrode Cooling/Heating | Liquid nitrogen, recirculating chiller, or resistive heating |
| RF Power Delivery | Top-mounted electrode with dual-frequency (LF/RF) capability |
| ICP Source Options | 65 mm, 180 mm, 300 mm |
| Process Pressure Range | Wide operational window enabled by high-pumping-speed vacuum system |
| Substrate Thickness Compatibility | Up to 10 mm |
| Backside He–cooling | Integrated electrostatic chuck with helium backside cooling |
| Endpoint Detection | Real-time optical emission spectroscopy (OES) monitoring |
| Chamber Architecture | Symmetric, low-inductance plasma chamber with uniform gas distribution and high-conductance pumping path |
| Brand | Paratronix |
|---|---|
| Origin | USA |
| Model | V494 (Vertical) / H1092 (Horizontal) |
| Voltage Options | Internal Transformer Supported |
| Cooling | Integrated Mechanical Chiller (LN₂-Free) |
| Control System | PLC with Touchscreen HMI (Rotating & Tilting Pod), USB & Ethernet Connectivity |
| Operation Modes | Manual, Semi-Automatic Batch, Recipe-Driven Deposition |
| Safety Features | Over-Temperature Cut-off, Vacuum-Level Interlock, Alarm History Logging |
| Compliance | UL 508A (US/CAN), CE Marked |
| Warranty | 1 Year |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurin i4 |
| Isolation Start Frequency | 0.6 Hz |
| Peak Isolation Performance | −40 dB at 10 Hz (99% vibration attenuation) |
| Settling Time | 0.3 s |
| Degrees of Freedom | 6-DOF active compensation |
| Power Supply | Standard AC outlet (no compressed air required) |
| Load Auto-Adaptation | Yes |
| Transport Lock | Integrated and automatic |
| Structural Stiffness | High intrinsic rigidity for positional stability |
| Compliance | Designed for ISO 14644-1 Class 5–8 cleanroom environments and compatible with GLP/GMP-aligned lab infrastructure |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurion Nano Series |
| Type | Active 6-DOF Vibration Isolation System |
| Operating Frequency Range | Active isolation from 0.7 Hz, passive isolation up to 200 Hz |
| Setup Time | < 0.3 s |
| Power Supply | Standard AC mains (no compressed air required) |
| Controller | External low-heat, EMI-isolated electronics unit |
| Structural Frame | Optional welded steel support table with high horizontal & vertical stiffness |
| Compliance | Designed for ISO 14644-1 Class 5 cleanroom-compatible environments and GLP/GMP-aligned lab infrastructure |
| Sample Load Capacity | Optimized for light-weight, high-sensitivity instruments (e.g., AFM, optical interferometers, nanoindenter stages) |
| Brand | Park SYSTEMS |
|---|---|
| Origin | Germany |
| Model | i4 |
| Dimensions | 400 × 500 × 90 mm |
| Payload Capacity | 0–120 kg |
| Active Isolation Bandwidth | 0.6/1 Hz to 200 Hz |
| Degrees of Freedom | 6-DOF |
| Settling Time | ≤ 0.3 s |
| Power Supply | Standard AC Mains (No Compressed Air Required) |
| Stiffness at 1 Hz | 20–30× Higher Than Passive Air Tables |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 4871 High-Pressure, Precision-Temperature-Controlled Corrosion Research System |
| Pricing | Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Instrument Type | Imported Laboratory System |
| Model | 2901 Ignition Propellant Combustion & Ultra-Fast Pressure Release Curve Analyzer |
| Pricing | Available Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | VLE-2000 Vapor-Liquid Equilibrium (VLE) Vapor Pressure Measurement System |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB200 |
| Pricing | Upon Request |
| Volume | 12 L |
| Inner Diameter | 200 mm |
| Height | 520 mm |
| Controller Dimensions | 220 mm × 80 mm × 70 mm |
| Input Voltage/Power | 85–250 VAC / 5 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB-200 |
| Pricing | Available Upon Request |
| Cultivation Volume | 12 L |
| Internal Diameter | 200 mm |
| Height | 520 mm |
| Controller Dimensions | 220 × 80 × 70 mm |
| Controller Input Voltage | 85–250 VAC |
| Controller Power Consumption | 5 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB200 |
| Pricing | Available Upon Request |
| Volume | 12 L |
| Internal Diameter | 200 mm |
| Height | 520 mm |
| Controller Dimensions | 220 × 80 × 70 mm |
| Input Voltage/Power | 85–250 VAC / 5 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB_200 |
| Pricing | Upon Request |
| Volume | 12 L |
| Inner Diameter | 200 mm |
| Height | 520 mm |
| Controller Dimensions | 220 mm × 80 mm × 70 mm |
| Input Voltage/Power | 85–250 VAC / 5 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB_250 |
| Pricing | Available Upon Request |
| Volume | 12 L |
| Internal Diameter | 200 mm |
| Height | 520 mm |
| Controller Dimensions | 220 mm × 80 mm × 70 mm |
| Input Voltage/Power | 85–250 VAC / 5 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB-250 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB-250 |
| Price | Upon Request |
| Cultivation Volume | 12 L |
| Inner Diameter | 200 mm |
| Height | 520 mm |
| Controller Dimensions | 220 × 80 × 70 mm |
| Input Voltage | 85–250 VAC |
| Controller Power Consumption | 5 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB250 |
| Pricing | Upon Request |
| Volume | 12 L |
| Internal Diameter | 200 mm |
| Height | 520 mm |
| Controller Dimensions | 220 × 80 × 70 mm |
| Input Voltage | 85–250 VAC |
| Controller Power Consumption | 5 W |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PE Drum |
| Pricing | Available Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | PQZL-1000 |
| Heating Method | Far-Infrared Ceramic Radiant Heating |
| Cooling System | Integrated Compressor-Based Closed-Loop Chiller |
| Distillation Channels | 6 Independent Units |
| Control Interface | 7-inch HD Touchscreen LCD |
| Temperature Range | Ambient to 300 °C |
| Heating Ramp Time | <8 min |
| Distillation Modes | Gravimetric (1–600 g, ±2 g accuracy) and Timed (1–600 min) |
| Endpoint Detection | Dual-mode (load cell + timer) with anti-suckback valve activation |
| Cleaning | Integrated auto-cleaning pump |
| Preloaded Methods | 7 factory-default protocols + user-customizable method storage |
| Single-Channel Control | Yes |
| Compliance | Designed for GLP-compliant laboratory workflows requiring audit-ready operation logs |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | PQZL-1000W |
| Heating Method | Far-infrared Ceramic Radiant Heating |
| Temperature Range | Ambient to 300°C |
| Heating Channels | 6 Independent |
| Control Interface | 7-inch HD Touchscreen LCD |
| Control Core | Microcontroller-based Embedded System |
| Distillation Modes | Gravimetric (1–600 g, ±2 g accuracy) & Timed (1–600 min) |
| Cooling | External Compressor-based Refrigerated Circulator |
| Auto-endpoint Detection | Dual-mode (mass-based + timer-based) |
| Anti-suckback Protection | Integrated Solenoid Valve & Flow Locking Mechanism |
| Auto-cleaning Function | Built-in Peristaltic Cleaning Pump |
| Preloaded Methods | 7 Standard Protocols + User-Defined Method Storage |
| Single-Channel Independence | Yes |
| Warm-up Time | <8 min |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-800 |
| Sample Capacity | ≤5 g (solid) / ≤15 mL (liquid) |
| Nitrogen Range | 0.08–200 mg N |
| Recovery Rate | >99.5% |
| Precision (RSD) | ≤0.5% |
| Distillation Time | 1–99 min |
| Distillation Rate | 14–28 mL/min (adjustable) |
| Power Adjustment | 750–1500 W |
| Cooling Water Requirement | ≥1.5 L/min at ≤20 °C, min. pressure 0.15 MPa |
| Data Storage | ≥100 distillation programs, ≥1000 sample records |
| Safety Features | Dual-level digestion flask level sensing, real-time cooling water flow/pressure monitoring, reagent level detection (H₂SO₄, NaOH, boric acid, diluent), digestion chamber temperature monitoring, condensate temperature cutoff, interlocked safety door sensor, intermittent alkali addition control |
| Construction | Monolithic ABS engineering plastic chassis |
| Dimensions | 370 × 300 × 680 mm |
| Electrical | 220 V AC, 50 Hz, 3.5–7 A |
| Brand | Ted Pella |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PELCO easiGlow™ 91000 |
| Plasma Current | 0–30 mA |
| Power | 30 W |
| Electrode Polarity | Reversible (Positive/Negative) |
| Sample Stage Diameter | 75 mm |
| Stage Height Adjustment | 1–25 mm |
| Delay Time | 0–14,400 s |
| Treatment Time | 0–900 s |
| Chamber Dimensions | 120 × 100 mm |
| Gas Inlets | Two 6 mm ports |
| Vacuum Control | Electromechanical proportional valve with Pirani gauge |
| Operating Vacuum Range | 1.1–0.20 mbar |
| Ultimate Vacuum (with optional GD4 pump) | 0.03 mbar |
| Pump Speed (GD4) | 2.5 m³/hr |
| Display | 3″ LED-backlit touchscreen with five dedicated function keys |
| Control Modes | Auto-programmable (up to 4 user-defined protocols) + Manual mode |
| Safety | Dual hardware/software vacuum interlock |
| Dimensions (unit) | 305 × 292 × 230 mm (L×W×H) |
| Weight (unit) | 6.26 kg |
| Optional GD4 Pump Dimensions | 337 × 138 × 244 mm |
| GD4 Weight | 11 kg |
| Electrical Requirement | 230 V, 50 Hz, 10 A |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CHF-XM Series |
| Pricing | Available Upon Request |
| Light Output Modes | Point Source, Collimated Beam, Fiber-Coupled Output |
| Point Source Diameter | 4–6 mm |
| Collimated Beam Diameter | 50 mm |
| Beam Divergence | ≤0.85° (at working distance < 250 mm) |
| Spectral Range | 300–1100 nm |
| Irradiance Uniformity (Φ60 mm) | ≤ ±11% |
| Local Uniformity (2 cm × 2 cm area) | ≤ ±5% |
| Focusing Capability | Adjustable between point source and Φ60 mm collimated output |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Labsolar-IIIAG |
| Pricing | Available Upon Request |
| Vacuum Level | ≤0.1 MPa (absolute) |
| Operating Pressure Range | 0 kPa to ambient pressure |
| Gas Tightness | ≤1 kPa pressure change over 24 h |
| Tubing Material | High-borosilicate glass |
| Minimum Tubing ID | 3 mm |
| Total System Volume | 150 mL |
| Sampling Loop Volume | 1.5 mL |
| Gas Storage Vessel | 250 mL |
| Condenser Type | Spherical condenser |
| Cold Trap | Integrated for low-boiling component separation |
| Vacuum Pump | Single-stage rotary vane pump, pumping speed ≥6 L/s |
| Magnetic Circulator Speed | ≥4000 rpm |
| H₂ Calibration Linearity | R² > 0.999 in range 100 μL–10 mL |
| Repeatability (RSD) | <3% for quadruplicate injections |
| Valve Count | 13 |
| Valve Material | High-borosilicate glass with precision lapped plug-and-body |
| Vacuum Grease | Dow Corning high-performance vacuum grease (–40°C to 200°C, low vapor pressure, chemical resistant) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR PTCS-31 |
| Power Supply | AC 220 V, 50/60 Hz |
| Total Power | 1500 W (LED source: 900 W |
| Water cooling | 600 W) |
| Maximum Achievable Temperature | ≥500 °C (center zone, ±5 cm) |
| Reaction Tube Dimensions | Φ10 × Φ7 × 400 mm (quartz glass standard |
| Collector Tube Dimensions | Φ58 × Φ43 × 330 mm |
| Collector Tube Material | High-borosilicate glass with selective solar-absorbing coating |
| Long-term Operating Temperature Range (collector) | 5–300 °C |
| Short-term Exposure Limit | up to 500 °C (coating degradation risk above 300 °C) |
| Illumination Uniformity | >90% across irradiated surface |
| Peak Irradiance | ≥300 mW/cm² (at 1-sun equivalent, initial condition) |
| Spectral Control | Three-zone independently adjustable LED array (UV–vis–NIR) |
| Temperature Monitoring | Multi-point thermocouple interfaces along U-shaped reaction tube |
| Cooling | Integrated closed-loop water circulation system |
| Ambient Operating Conditions | 0–45 °C, non-condensing |
| Storage Conditions | −10–60 °C, 30–85% RH (drain coolant before storage below 0 °C) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLR-GSPR |
| Pricing | Upon Request |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-MPPT-X |
| Gas Flow Control | 3-channel MFC (2–100% F.S., ±1% F.S. accuracy) |
| Liquid Delivery | 1-channel bubbling system (0–120 °C, ±1 °C control) |
| Light Source Compatibility | Xenon lamp (50 mm diameter irradiation area, 19.625 cm²) |
| Plasma Power Supply | 0–500 W, 0–30 kV output, 5–20 kHz frequency, integrated power measurement circuit |
| Heating Capability | Resistive heating plate (RT–300 °C), optional tubular furnace (RT–800 °C, ±1 °C precision) |
| Reactor Types | Integrated flat-plate multi-field coupling reactor (7.5 mL max. catalyst volume, 3 mm discharge gap) + optional tubular reactor (1.8 mL, 2 mm gap) |
| Temperature Monitoring | Up to 600 °C at reactor outlet, −100 to +100 kPa gauge pressure sensing |
| Data Acquisition | RS485-enabled multi-channel temperature/pressure/flow/power monitoring with real-time logging |
| Software | Local HMI + cloud-enabled IoT control interface (remote parameter setting, alarm management, historical trend analysis) |