Other Common Laboratory Equipment
Filter
Showing 1711–1740 of 1883 results
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | VF205B |
| Vacuum Level | ≥150 mbar |
| Air Flow Rate | ≤34 L/min |
| Motor Speed | 1450 rpm |
| Interface Diameter | 9 mm |
| Weight | 7.5 kg |
| Noise Level | 50 dB(A) |
| Power Supply | 220–240 V / 50 Hz |
| Rated Power | 80 W |
| Includes | VF2 Glass Filtration Bottle Set |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | VF214 |
| Vacuum Level | ≥13 mbar |
| Air Displacement Rate | ≤25 L/min |
| Motor Speed | 1450 rpm |
| Port Diameter | 9 mm |
| Weight | 8.3 kg |
| Noise Level | 50 dB(A) |
| Power Supply | 220–240 V / 50 Hz |
| Rated Power | 95 W |
| Includes | VF3 borosilicate glass filtration assembly, Dragon100 Bunsen burner, silicone tubing, 0.2 µm PTFE hydrophobic vent filter, and 1 µm glass fiber filter paper |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WFM |
| Dimensions | 63.5 mm (H) × 95.0 mm (W) × 138.0 mm (D) |
| Input Voltage | 230 V AC |
| Max Load Capacity | 2300 W |
| Flow Sensor Options | WFM-01 (0.1–2.5 L/min), WFM-02 (1–10 L/min), WFM-03 (2–30 L/min) |
| Shut-off Valve | 250MV Solenoid Valve |
| Audible Alarm | WFM-AA, 70 dB |
| Digital Alarm Output | WFM-OC, 170 mA current signal |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | AMW |
| Output Voltage | ±20 kV DC or AC peak |
| Output Power | 400 W |
| Output Current | ±20 mA DC or AC peak |
| Input Range | ±10 V DC or AC peak |
| Gain | 2000 V/V (DC) |
| Gain Accuracy | < ±0.1% of full scale |
| Output Noise | < 1.5 Vrms |
| Slew Rate | > 450 V/µs (10–90%) |
| Large-Signal Bandwidth | DC to > 7.5 kHz (–3 dB), DC to > 3.75 kHz (1% THD) |
| Small-Signal Bandwidth | DC to > 20 kHz (–3 dB) |
| Stability | < 50 ppm/hr (non-cumulative) |
| Tempco | < 25 ppm/°C |
| Operating Temp | 0–40 °C |
| Humidity | ≤85% RH, non-condensing |
| Altitude | ≤2000 m |
| Dimensions | 264 × 483 × 635 mm (H×W×D) |
| Weight | 25 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Display Resolution | Voltage: 2000:1 (0.1% FS accuracy) |
| Current | 1 V / 6 mA (0.5% FS accuracy) |
| Brand | Wiseman |
|---|---|
| Model | AMX |
| Output Voltage | ±30 kV DC or AC peak |
| Output Current | ±20 mA DC or AC peak |
| Power Rating | 600 W |
| Input Voltage | 220 V AC ±10% |
| Input Current | 10 A |
| Gain | 3000 V/V (DC) |
| Gain Accuracy | < 0.1% of full scale |
| Output Noise | < 1.5 V RMS |
| Slew Rate | > 550 V/µs (10%–90%) |
| Large-Signal Bandwidth | DC to > 2.5 kHz |
| Small-Signal Bandwidth (−3 dB, 1% THD) | DC to > 30 Hz |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Altitude | ≤2000 m |
| Dimensions | 1040 mm H × 430 mm W × 870 mm D |
| Weight | 70 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Voltage Display Scale | 3000:1 |
| Current Display Scale | 1 V / 6 mA |
| Voltage Display Accuracy | < 0.1% FS |
| Voltage Display Offset | < ±5 mV |
| Voltage Display Noise | < 20 mV RMS |
| Current Display Accuracy | < 0.5% FS |
| Current Display Offset | < ±10 mV |
| Current Display Noise | < 30 mV RMS |
| Quadrant Operation | Four-quadrant active output (source/sink) |
| Load Compatibility | Resistive, capacitive, and reactive loads |
| Isolation | Fully solid-state high-voltage insulation |
| Application Focus | Mass spectrometry biasing, electro-optic modulation, ferroelectric polarization, plasma actuation, ion beam steering |
| Brand | Wiseman |
|---|---|
| Model | AMY |
| Output Voltage | ±40 kV (DC or AC peak) |
| Output Current | ±15 mA (DC or AC peak) |
| Power Rating | 600 W |
| Input Voltage Range | ±10 V DC or AC peak |
| Voltage Gain | 4000 V/V (DC) |
| Gain Accuracy | < 0.1% of full scale |
| Output Noise | < 5 V RMS |
| Slew Rate | > 350 V/µs (10%–90%) |
| Small-Signal Bandwidth (−3 dB, 1% THD) | DC to > 20 Hz |
| Large-Signal Bandwidth | DC to > 1.4 kHz |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Altitude | ≤2000 m |
| Dimensions (H×W×D) | 1040 × 430 × 870 mm |
| Weight | 90 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Display Resolution | 4000:1 (voltage), 1 V/5 mA (current) |
| Protection | Active short-circuit protection, four-quadrant active output, thermal and overcurrent monitoring |
| Brand | Wiseman |
|---|---|
| Model | AMZ |
| Output Voltage | ±50 kV DC or AC peak |
| Output Power | 600 W |
| Output Current | ±12 mA DC or AC peak |
| Input Signal Range | ±10 V DC or AC peak |
| Voltage Gain | 5000 V/V (DC) |
| Gain Accuracy | < ±0.1% of full scale |
| Output Noise | < 10 V RMS |
| Slew Rate | > 350 V/µs (10–90%) |
| Large-Signal Bandwidth | DC to > 1.4 kHz |
| Small-Signal Bandwidth (−3 dB, 1% THD) | DC to > 20 Hz |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Humidity | ≤75% RH (non-condensing) |
| Altitude | Up to 2000 m |
| Dimensions | 1473.5 × 628.7 × 948.4 mm |
| Weight | 125–136 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Voltage Display Ratio | 5000:1 |
| Current Display Ratio | 0.5 V/mA |
| Short-Circuit Protection | Active, programmable |
| Quadrant Operation | Four-quadrant active output (source/sink) |
| Load Compatibility | Resistive, capacitive, and reactive loads |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | B |
| Output Voltage Range | 0.3–25 kV (selectable in standard steps) |
| Output Power | 6 W |
| Input Voltage | 2–24 VDC |
| Input Current | ≤360 mA |
| Polarity | Reversible Bipolar (±) |
| Isolation Voltage | ±7 kV DC (≤6 kV models) |
| Load Regulation | 12% (for 50% load change) |
| Protection | Arc detection & transient short-circuit protection |
| Operating Temperature | −10 °C to +60 °C |
| Humidity | 30–85% RH (non-condensing) |
| Compliance | Designed for OEM integration in analytical instrumentation requiring IEC 61010-1 safety isolation and EMC robustness |
| Primary Applications | Mass spectrometry ion sources, PMTs, MCPs, electron/ion beam focusing, electrostatic chucks, piezoelectric actuators, avalanche photodiodes |
| Brand | Wiseman |
|---|---|
| Output Voltage Range | 0.1–10 kV (selectable) |
| Output Power | 0.5–1.25 W |
| Input Voltage Options | +5 VDC ±2% (standard), +12/+15/+24 VDC (optional) |
| Input Current | 550 mA |
| Isolation Voltage | ≤ ±500 VDC |
| Voltage Accuracy | ±10% at rated load |
| Operating Temperature | +25 °C to +75 °C |
| Storage Temperature | −55 °C to +105 °C |
| Humidity | ≤80% RH, non-condensing |
| Dimensions | 11 mm × 11 mm × 11 mm (≤2 kV) |
| Weight | 5 g (≤2 kV) |
| Polarity | Bipolar (simultaneous or reversible ± output) |
| Mounting | Floating operation compatible |
| Compliance | Designed for OEM integration in analytical and scientific instrumentation |
| Brand | Wiseman |
|---|---|
| Model | BP |
| Output Voltage | 0.5 kV (100–500 V DC selectable) |
| Output Power | 2.5 W |
| Input Voltage Range | +2 to +24 V DC |
| Isolation Voltage | 500 V DC (input-to-output) |
| Ripple | ≤0.5% p-p |
| Temperature Coefficient | 25 ppm/°C |
| Load Regulation | ≤5% over 20–100% load |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +60 °C |
| Dimensions | 60 mm × 40 mm × 17 mm |
| Weight | 50 g |
| Compliance | Designed for OEM integration in analytical instrumentation requiring stable, isolated HV bias |
| Brand | Wiseman |
|---|---|
| Model | DED |
| Output Voltage Range | 0.5–50 kV (adjustable) |
| Output Current Range | 0–50 mA |
| Maximum Output Power | 100 W |
| Input | AC 86–256 V ±10%, 3 A |
| Ripple | ≤0.1% peak-to-peak of rated output voltage |
| Stability | <25 ppm/h (after 30 min warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Voltage & Current Regulation | Local (multi-turn potentiometer) or Remote (0–10 V analog, USB/RS-232/RS-422 digital) |
| Protection Features | Overvoltage, Short-Circuit, Arc Detection, Interlock Safety |
| Dimensions | 310 × 130 × 185 mm |
| Weight | 2.5–6.2 kg |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Wiseman |
|---|---|
| Model | DEF |
| Output Voltage Range | 1–70 kV DC |
| Maximum Continuous Output Power | 350 W |
| Input Voltage | 86–265 VAC, 47–63 Hz |
| Power Factor | ≥0.99 (with active PFC) |
| Ripple | ≤0.1% RMS (≤20 kHz) |
| Voltage Stability | <25 ppm/8 h (after 2-h warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Output Polarity | Selectable Positive or Negative HV |
| Control Interfaces | Local front-panel potentiometer, Analog 0–10 V remote control, RS-232, RS-485, Ethernet (optional) |
| Protection Features | Overvoltage, Overcurrent, Arc Detection, Short-Circuit, Interlock |
| Dimensions (W×H×D) | 80 × 254 × 280 mm |
| Weight | 5.5 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Compliance | Designed for laboratory and industrial HV applications requiring IEC 61010-1 safety principles and electromagnetic compatibility per EN 61326-1 |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | DF |
| Output Voltage Range | 1–70 kV DC |
| Output Power | 4 kW |
| Ripple | 0.03% p-p |
| Stability | <0.02% per 8 hours (after 1-hr warm-up) |
| Temperature Coefficient | 25 ppm/°C |
| Input | AC 220 V ±10% (3-phase optional) |
| Interfaces | Standard Ethernet & RS-232 |
| Protection | Overvoltage, Overcurrent, Short-Circuit, Arc Detection, Overtemperature, Safety Interlock |
| Compliance | CE certified |
| Remote Control | 0–10 V analog voltage/current setpoint & monitor signals |
| Dimensions (4 kW unit, ≤60 kV) | 132 mm H × 483 mm W × 610 mm D (3U 19″ rack) |
| Application | Mass spectrometry systems, electron/ion beam sources, X-ray generators, high-energy physics instrumentation, semiconductor processing equipment |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | DH |
| Output Voltage | 0–150 kV (200 kV standard option, 300 kV customizable) |
| Output Power | 2 kW |
| Input | AC 220 V ±10%, 15 A |
| Ripple | 0.1% P-P + 1 Vrms |
| Stability | <100 ppm/h after 30-min warm-up |
| Temperature Coefficient | 100 ppm/°C |
| Voltage & Current Control | Local (multi-turn potentiometers) and Remote (0–10 V analog interface) |
| Communication Interfaces | Standard Ethernet + RS-232, optional RS-485 |
| Protection Features | Overvoltage, overcurrent, short-circuit, arc detection, overtemperature, safety interlock |
| Compliance | CE certified |
| Dimensions (150 kV unit) | 4U (176 mm H × 483 mm W × 559 mm D) |
| Display | 4-digit LED panel meter (±1% accuracy at rated output) |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Brand | Wiseman |
|---|---|
| Output Voltage Range | 1–130 kV (selectable) |
| Output Power | Up to 1.2 kW |
| Ripple | 0.1% P-P |
| Voltage Stability | <100 ppm/8 h (after 30-min warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Control Interface | RS-232, Ethernet (standard), RS-485 (optional) |
| Safety Features | Overvoltage, Overcurrent, Arc Detection, Short-Circuit, Overtemperature, Interlock |
| Compliance | CE Certified |
| Input | AC 220 V ±10%, 10 A (AC 110 V optional) |
| Operating Temperature | 0–50 °C |
| Dimensions | 1U or 2U (44 mm or 88 mm H) × 483 mm W × 483 mm / 610 mm D |
| Application-Specific Design | Optimized for electrophoresis systems and high-voltage scientific instrumentation |
| Brand | Wiseman |
|---|---|
| Model | DNA30kV/15W |
| Output Voltage | 30 kV (adjustable from 600 V to 30 kV) |
| Output Current | 0.5 mA |
| Output Power | 15 W |
| Ripple & Noise | <0.01% p-p |
| Stability | ±0.02% over 8 hours |
| Temperature Coefficient | 25 ppm/°C |
| Input | DC 24 V |
| Communication Interface | Optional RS-232 / RS-485 |
| Polarity | Selectable Positive or Negative |
| Protection | Arc detection, short-circuit protection |
| Dimensions (H×W×D) | 43.0 × 100.0 × 205.0 mm |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–+85 °C |
| Humidity | 20–85% RH (non-condensing) |
| Compliance | Designed for OEM integration in analytical instrumentation requiring IEC 61010-1 safety and EMC robustness |
| Brand | Wiseman |
|---|---|
| Model | DR |
| Output Polarity | Reversible |
| Max Output Voltage | 300 kV |
| Max Output Power | 6 kW |
| Ripple | 0.1% P-P + 1 Vrms |
| Stability | <100 ppm/h (after 30 min warm-up) |
| Temperature Coefficient | 25 ppm/°C |
| Control Interfaces | Standard Ethernet & RS-232, Optional RS-485 |
| Protection | Overvoltage, Overcurrent, Short-Circuit, Arc Detection, Overtemperature, Safety Interlock |
| Compliance | CE Certified |
| Dimensions (1–120 kV) | 266 mm H × 483 mm W × 533 mm D (6U 19″ rack) |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Display | 4-digit LED panel meter (±1% accuracy at rated output) |
| Remote Control | 0–10 V analog for voltage/current setpoint and monitoring |
| Optional Feature | Constant Power Control (CPC) |
| Brand | Wiseman |
|---|---|
| Model | EM30kV/9W |
| Output Voltage Range (Accelerator) | –30 kV to +30 V |
| Output Current | 200 µA |
| Load Regulation | < ±100 ppm (0–100% load) |
| Line Regulation | < ±100 ppm (±10% input variation) |
| Ripple | ≤10 ppm |
| Temperature Coefficient | 100 ppm/°C |
| Short-Term Stability | 10 ppm / 3 min (after 1-hr warm-up) |
| BIAS Output | 0 to –2000 V, 0–150 µA |
| FIL+ Output | 0–3 A @ 1 Ω |
| SCI Output | 0–10 kV, 0–250 µA |
| COL Output | 0–400 V, 0–500 µA |
| PMT/MCP Output | 0–1500 V, 0–1000 µA |
| Operating Temperature | 0–40 °C |
| Cooling | Forced-air (front intake / rear exhaust) |
| Weight | 5 kg |
| Brand | Wiseman |
|---|---|
| Output Voltage | 7.5 V |
| Output Power | 37.5 W |
| Input Voltage | 24 V ±10 V |
| Input Current (Full Load) | 3 A |
| Output Voltage Stability | ≤0.1 %/h after warm-up |
| Ripple & Noise | ≤200 mVpp (typ.) |
| Voltage Regulation (Line) | ≤0.01 % (typ.) |
| Load Regulation | ≤0.01 % (typ.) |
| Temperature Coefficient | <0.1 %/°C |
| Isolation Voltage | 5–30 kV (selectable) |
| Control Interface | 0–10 V analog input (5 kΩ input impedance) |
| Rise Time (0–99%) | 100 ms |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −35–+85 °C |
| Humidity | ≤80 % RH (non-condensing) |
| Dimensions | 205 × 100 × 43 mm |
| Weight | 1.5 kg |
| Protection Features | Reverse polarity, overvoltage, short-circuit, arc detection, continuous overload |
| Compliance | Designed for OEM integration in mass spectrometry systems |
| Brand | Wiseman |
|---|---|
| Model | MA |
| Output Voltage | 0–10 kV (customizable) |
| Output Power | Up to 6 W |
| Output Current | 1–20 mA (model-dependent) |
| Input Voltage | DC 24 V ±1 V (optional: ±5 V, ±12 V, ±15 V) |
| Voltage Stability | ±0.001% |
| Ripple | ≤0.001% RMS |
| Temperature Coefficient | ±0.001%/°C |
| Line & Load Regulation | ±0.001% |
| Protection | Short-Circuit & Arc-Discharge |
| Operating Temp. | -10°C to +50°C (S-grade), -25°C to +65°C (G-grade), -40°C to +95°C (T-grade) |
| Dimensions | Ø70 × W57 × H22 mm |
| Certifications | ISO 9001, CE (per applicable directives), RoHS compliant |
| Application | Mass Spectrometry, Electron Microscopy, PMT Biasing, Ion/Electron Beam Acceleration, Electrostatic Applications |
| Brand | Wiseman |
|---|---|
| Model | MB |
| Output Voltage | ±0–3 kV (configurable dual-polarity) |
| Output Power | 2 W (total) |
| Ripple & Noise | <0.08% p-p |
| Stability | 0.001% per hour |
| Temp. Coefficient | 25 ppm/°C |
| Input Voltage | 12 V ±0.5 V (optional: 5 V, 15 V, 24 V) |
| Dimensions | 45.5 × 25 × 12 mm |
| Weight | 25 g |
| Shielding | Full 6-side electromagnetic shielding |
| Protection | Reverse polarity, overcurrent, short-circuit, arc suppression |
| Operating Temp. | –10°C to +50°C (commercial grade) |
| Compliance | Designed for OEM integration in analytical instrumentation requiring low-noise, high-stability bias supplies |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | MC |
| Output Voltage | 0–2 kV (adjustable, positive or negative polarity) |
| Output Power | 2 W |
| Output Ripple & Noise | ≤5 mVₚₚ (typical, at full load) |
| Stability | ±0.001% per hour |
| Temperature Coefficient | 10 ppm/°C |
| Input Voltage | 12 V ±0.5 V DC (optional: 5 V, 15 V, or 24 V ±1 V) |
| Control Interface | 0–5 V analog voltage or 20 kΩ potentiometer |
| Dimensions | 46 × 24 × 12 mm |
| Weight | 25 g |
| Protection Features | Reverse polarity, overcurrent, short-circuit, arc suppression, overvoltage control fault protection |
| Operating Temperature | 0–50 °C |
| Humidity | ≤80% RH (non-condensing) |
| Compliance | Designed for OEM integration in analytical and scientific instrumentation requiring IEC 61010-1 compliant HV subsystems |
| Primary Applications | PMT biasing, mass spectrometer ion optics, electron/ion beam focusing, radiation detectors (GM, proportional, ionization chambers), electrophoresis, electrostatic printing, and precision HV biasing in R&D labs |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | MCA |
| Output Voltage | 0.05–2 kV (adjustable) |
| Output Power | 3–5 W |
| Output Polarity | Positive or Negative |
| Input Voltage | 24 V DC |
| Ripple & Noise | ≤0.001% p-p |
| Stability | ±0.001% per hour |
| Temperature Coefficient | ±10 ppm/°C |
| Protection | Arc Detection, Short-Circuit, Overcurrent |
| Mounting | PCB-mount |
| Dimensions | 45 × 23 × 17 mm |
| Shielding | Full 6-Side EMI/RFI Shielding |
| Operating Temp. | –10°C to +50°C (Commercial S-grade), –25°C to +65°C (Industrial G-grade), –40°C to +95°C (Extended T-grade) |
| Compliance | Designed for OEM integration in analytical instrumentation requiring IEC 61000-4 EMC immunity and safety-aligned layout practices |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | MCC |
| Output Voltage | 0–3000 V (or 0 to –3000 V) |
| Output Power | 2 W |
| Ripple & Noise | < 0.001% P-P (at full load) |
| Stability | ±0.001% per hour |
| Temperature Coefficient | 10 ppm/°C |
| Input Voltage | 12 V ±0.5 V (optional: ±5 V, ±15 V, ±24 V) |
| Control Interface | 0–2.5 V analog or 20 kΩ potentiometer |
| Dimensions | 46 × 24 × 12 mm |
| Weight | 25 g |
| Protection | Reverse polarity, overcurrent, short-circuit, arc suppression |
| Operating Temperature | –10°C to +50°C (Commercial Grade S) |
| Compliance | Designed for OEM integration in analytical and scientific instrumentation |
| Brand | Wiseman |
|---|---|
| Model | MCE |
| Output Voltage | ±2 kV (adjustable 0–2000 V) |
| Output Power | 2 W |
| Output Ripple & Noise | ≤5 mV<sub>pp</sub> |
| Stability | 0.001% per hour |
| Temperature Coefficient | 10 ppm/°C |
| Input Voltage | 12 V ±0.5 V (optional: 5 V, 15 V, or 24 V ±1 V) |
| Control Interface | 0–2.5 V analog voltage or 20 kΩ potentiometer |
| Dimensions | 40 × 25 × 12 mm |
| Weight | 25 g |
| Operating Temperature | -10°C to +50°C (commercial grade S), -25°C to +65°C (industrial grade G), -40°C to +95°C (extended grade T) |
| Protection | Reverse polarity, overcurrent, short-circuit, arc detection, continuous overload |
| Shielding | Six-sided EMI shielding |
| Mounting | PCB-mount |
| Compliance | Designed for OEM integration in analytical instrumentation requiring stable, low-noise bias supply |
| Brand | Wiseman |
|---|---|
| Model | MCP2kV/2W |
| Output Voltage | ±0–2 kV (adjustable) |
| Output Power | 2 W |
| Output Ripple & Noise | <5 mV<sub>PP</sub> (<0.001% of full scale) |
| Stability | ±0.001% per hour |
| Temperature Coefficient | 15 ppm/°C |
| Input Voltage | +12 V ±0.5 V (optional: ±5 V, ±15 V, ±24 V) |
| Control Interface | 0–5 V analog or 20 kΩ potentiometer |
| Dimensions | 45.5 × 25 × 12 mm |
| Weight | 25 g |
| Shielding | Full 6-face mu-metal + conductive coating |
| Protection | Reverse polarity, overcurrent, short-circuit, arc suppression, overvoltage control |
| Compliance | Designed for GLP/GMP-aligned instrumentation environments |
| Brand | Wiseman |
|---|---|
| Output Voltage | 3 kV (adjustable up to 3 kV DC) |
| Output Power | 5 W |
| Input Voltage | 15 VDC ±1 V (optional 12 V / 24 V) |
| Ripple & Noise | <0.001% p-p |
| Stability | ±0.001% per hour |
| Temperature Coefficient | ±10 ppm/°C (equivalent to 0.001%/°C) |
| Voltage Regulation | ±0.01% (line), ±0.01% (load) |
| Protection | Short-circuit, arc discharge, over-current |
| Shielding | Full 6-side electromagnetic shielding |
| Operating Temperature | -10°C to +50°C (commercial grade S), -25°C to +65°C (industrial grade G), -40°C to +95°C (extended grade T) |
| Dimensions | 60 mm × 40 mm × 17 mm |
| Weight | 65 g |
| Compliance | Designed for integration into ISO/IEC 17025-compliant analytical instrument platforms |
| Brand | Wiseman |
|---|---|
| Model | MDC3kV/5W |
| Output Voltage | 3 kV DC |
| Output Power | 5 W |
| Ripple & Noise | <0.001% P-P |
| Stability | ±0.001% per hour |
| Temp. Coefficient | ±0.001% / °C |
| Input | 15 VDC ±1 V, 450 mA typ. |
| Dimensions | 60 mm × 40 mm × 17 mm |
| Weight | 65 g |
| Operating Temp. (S-grade) | −10 °C to +50 °C (case) |
| Protection | Arc detection, short-circuit protection |
| Mounting | PCB-mountable, six-sided EMI shielding |
| Polarity | Selectable positive/negative output |
| Compliance | Designed for OEM integration in regulated instrumentation environments |
| Brand | Wiseman |
|---|---|
| Output Voltage | 30 kV |
| Output Power | 100 W |
| Output Polarity | Selectable Positive/Negative |
| Ripple & Noise | <0.1% p-p |
| Stability | ±0.01% over 8 hours |
| Temperature Coefficient | 25 ppm/°C |
| Input | DC 24 V |
| Communication Interface | RS-232 or RS-485 (addressable multi-unit networking) |
| Protection | Arc detection, short-circuit protection, overvoltage/overcurrent limiting |
| Efficiency | Up to 90% |
| Certifications | CE compliant |
| Operating Temperature | 0–40 °C |
| Dimensions (30 kV model) | 43.0 × 100.0 × 205.0 mm (H×W×D) |
| Application | Mass spectrometry, photomultiplier tubes, particle detectors, electrostatic systems, scientific instrumentation |
| Brand | Wiseman |
|---|---|
| Model | MEA |
| Output Voltage | Up to 30 kV (selectable polarity) |
| Output Power | 15 W |
| Input Voltage | 105–125 VAC or 210–250 VAC, 48–63 Hz (400 Hz optional) |
| Ripple | ≤0.05% P-P of rated output |
| Stability | ≤0.01% per hour (after 30-min warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Protection | Overvoltage, Overcurrent, Arc Detection, Safety Interlock |
| Control Interface | Internal multi-turn potentiometer + 0–10 V analog remote setpoint (voltage & current) |
| Cooling | Convection |
| Compliance | Designed for OEM integration in analytical instrumentation requiring IEC 61010-1, EN 61326-1, and FDA 21 CFR Part 11–ready control architecture |