Other Common Laboratory Equipment
Filter
Showing 1771–1800 of 1883 results
| Brand | Wiseman |
|---|---|
| Output Voltage | -10 kV to -70 kV (selectable) |
| Output Power | 10 W to 100 W (6 standard ratings) |
| Filament Supply | Floating, 0.3–5 A, adjustable with preheat |
| Input | DC 24 V ±10%, 5 A |
| Stability | ≤0.05% over 8 h (after 30-min warm-up) |
| Ripple | ≤0.1% p-p of rated output voltage |
| Temperature Coefficient | ≤25 ppm/°C |
| Control Interfaces | Analog 0–10 V, USB 2.0, RS-232, RS-485, Ethernet (optional) |
| Compliance | Designed for OEM integration in analytical and industrial X-ray systems |
| Dimensions (10–50 kV) | 205 × 75 × 185 mm |
| (60–70 kV) | 228.5 × 75 × 185 mm |
| Weight | 4.7–5.15 kg |
| Safety Protections | Overvoltage, overcurrent, arc detection, interlock-enabled shutdown |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | XN |
| Output Voltage | 50 kV (selectable from 6–50 kV in 10 kV increments) |
| Output Power | 50 W |
| Ripple | ≤0.1% p-p |
| Stability | ≤0.05%/8 h |
| Temperature Coefficient | ≤25 ppm/°C |
| Filament Supply | 0–3.5 A, 0–5.5 V DC |
| Input | 24 V ±10% DC, 5.0 A |
| Dimensions | 75.0 × 75.0 × 205.0 mm |
| Weight | 1.5 kg |
| Compliance | CE-marked for industrial EMC and safety (IEC 61000-6-3, IEC 61000-6-4, IEC 61010-1) |
| Communication Interfaces | Optional USB 2.0, RS-232, RS-422, or Ethernet (IEEE 802.3) |
| Brand | Wiseman |
|---|---|
| Output Voltage | 30 kV |
| Output Power | 100 W |
| Filament Supply | 0–5.5 V / 0–3.5 A DC |
| Ripple | 0.001% p-p (LR10 option) |
| Stability | ≤10 ppm/hour |
| Temperature Coefficient | ≤10 ppm/°C (LR10) |
| Input | 24 V ±10% DC, 3.0 A |
| Dimensions | 65 × 115 × 150 mm |
| Weight | 1.55 kg |
| Interface Options | USB 2.0, RS-232, RS-422 |
| Protection | Overvoltage, Short-Circuit, Interlock |
| Compliance | Designed for integration into ISO/IEC 17025-compliant analytical instrumentation and FDA 21 CFR Part 11-ready systems |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | XRB140kV/300W |
| Output Voltage | ±70 kV (140 kV bipolar) |
| Output Power | 300 W |
| Stability | < 0.02% over 8 hours after 30-min warm-up |
| Ripple | ≤ 0.1% pk-pk of rated output voltage |
| Temperature Coefficient | 25 ppm/°C |
| Input | Universal AC/DC, 3.25 A max |
| Filament Supply | 0–5.5 V / 0–5 A adjustable |
| Remote Control | 0–10 V analog for voltage & current |
| Interface Options | USB 2.0, RS-232, RS-485 |
| Operating Temp. | 0–50 °C |
| Dimensions (140 kV) | 335 × 210 × 160 mm |
| Weight (140 kV) | 14.2 kg |
| Compliance | Designed for OEM integration in analytical and industrial X-ray systems per IEC 61010-1 safety requirements |
| Brand | Wiseman |
|---|---|
| Output Voltage Range | 10–70 kV (selectable) |
| Output Power | 120 W |
| Input Voltage | 85–265 VAC, 47–63 Hz |
| Voltage Stability | ≤25 ppm/hr (after 2-hr warm-up) |
| Ripple | ≤1% RMS (>20 kHz), 0.1% RMS (≤20 kHz) |
| Temperature Coefficient | ≤25 ppm/°C |
| Filament Output | 0–5 A, 0–10 V (closed-loop controlled) |
| Control Interface | Analog 0–10 V + RS-232 |
| Protection | Overvoltage, Arc Detection, Short-Circuit, Interlock |
| Dimensions (10–50 kV) | 92 × 127 × 230 mm, 3.5 kg |
| Dimensions (60–70 kV) | 92 × 127 × 180 mm, 4.5 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Humidity | 20–85% RH (non-condensing) |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | XRH |
| Output Voltage | Up to 180 kV (DC, negative polarity) |
| Output Power Options | 80 W / 320 W / 640 W |
| Output Current | Up to 4 mA @ 160 kV |
| Filament Supply | 0–7 V / 5 A DC, adjustable |
| Grid Bias Supply | 0–−1200 V / 100 mA DC, adjustable |
| Stability | ≤0.1% of set value after 30-min warm-up |
| Ripple | ≤0.1% p-p (≤320 W), ≤0.7% p-p (640 W) |
| Temperature Drift | 25 ppm/°C |
| Input | AC 220 V ±10%, 50 Hz |
| Cooling | Forced air (front-side intake, rear exhaust) |
| Dimensions | 176 mm H × 483 mm W × 558.8 mm D (4U rack-mount) |
| Weight | 30 kg |
| Compliance | Designed for integration into ISO/IEC 17025-compliant X-ray imaging systems |
| Brand | Wiseman |
|---|---|
| Output Voltage | Up to 130 kV (configurable from 20–130 kV) |
| Output Power | Up to 200 W |
| Polarity | Positive or Negative HV Output |
| Filament Supply | 0–10 V / 0–5 A, adjustable with preheat function |
| Stability | <100 ppm/h (after 30-min warm-up) |
| Ripple | ≤0.1% p-p of rated output voltage |
| Temperature Coefficient | ≤25 ppm/°C |
| Input | AC/DC selectable, max 4 A |
| Control Interfaces | Local potentiometer, 0–10 V analog remote, RS-232/RS-422/RS-485/USB digital control |
| Protection | Overvoltage, overcurrent, arc detection, interlock safety circuit |
| Cooling | Convection |
| Dimensions | 260 × 100 × 170 mm |
| Operating Temp. | 0–50 °C |
| Storage Temp. | −40–85 °C |
| Humidity | 20–85% RH (non-condensing) |
| Compliance | Designed for integration into IEC 61010-1 compliant analytical and industrial X-ray systems |
| Brand | Wiseman |
|---|---|
| Output Voltage Range | 6–70 kV (9 selectable max voltages) |
| Output Power Options | 10–100 W (6 options) |
| Input | 24 VDC ±10%, ≤3.0 A |
| Filament Supply | 0–3.5 A / 0–5.5 V adjustable |
| Voltage Regulation | ≤0.001% (load & line) |
| Current Regulation | ≤0.001% (load & line) |
| Ripple | ≤0.01% p-p of rated output |
| Stability | ≤0.01%/hr (after 30 min warm-up), ≤0.02%/8 hr |
| Temp. Coefficient | ≤25 ppm/°C (V/I) |
| Operating Temp. | 0–50 °C |
| Dimensions | 65 × 115 × 150 mm (H×W×D) |
| Compliance | ISO 9001:2008 certified |
| Interface Options | Analog 0–10 V remote control (voltage & beam current), RS232 (selected models) |
| Mounting | Compact chassis-mount design |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | ZA |
| Output Voltage Range | ±50 V to ±2 kV |
| Output Power | 2 W |
| Ripple | 5 mV (typ.) |
| Stability | 0.001 %/hr |
| Temperature Coefficient | <10 ppm/°C |
| Voltage Regulation | 0.001 % (line), 0.001 % (load) |
| Rise/Fall Time | <10 µs (typ.) |
| Protection | Short-Circuit & Arc-Discharge |
| Input | 24 VDC ±1 V, 450 mA (typ.) |
| Dimensions | 70 mm × 57 mm × 22 mm |
| Operating Temp. | 0–45 °C |
| Storage Temp. | −40–+85 °C |
| Humidity | 20–95 % RH (non-condensing) |
| Weight | 120 g (typ.) |
| Compliance | CE-marked for industrial lab use |
| Application | Dedicated power supply for mass spectrometer ion optics (lenses, dynodes, ionization sources), electrophoresis, electrostatic focusing/deflection, and bipolar HV amplification |
| Brand | Wisman |
|---|---|
| Model | AME |
| Output Voltage Range | ±4 kV DC or AC peak |
| Output Power | 80 W |
| Output Current Range | ±20 mA DC or AC peak |
| Gain | 1000 V/V (DC) |
| Gain Accuracy | Better than 0.1% of full scale |
| Slew Rate | >35 V/μs (10%–90%) |
| Small-Signal Bandwidth | DC to 35 kHz (−3 dB) |
| Large-Signal Bandwidth | DC to 600 Hz (1% THD), DC to 13 kHz (−3 dB) |
| Output Noise | <50 mV RMS (voltage), <2 mV RMS (voltage monitor), <10 mV RMS (current monitor) |
| Stability | <50 ppm/h (non-cumulative) |
| Temperature Coefficient | <25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH, non-condensing |
| Altitude Limit | ≤2000 m |
| Dimensions | 88 mm H × 432 mm W × 439 mm D |
| Weight | 7 kg |
| Input | 220 VAC ±10%, 1 A |
| Input Impedance (non-inverting) | 25 kΩ |
| Output Impedance | 47 Ω |
| Voltage Monitor Scale | 1000:1, accuracy >0.1% FS, offset <±2 mV |
| Current Monitor Scale | 1 V / 0.8 mA, accuracy >0.5% FS, offset <±5 mV |
| Quadrant Operation | Four-quadrant active output (source/sink) |
| Load Compatibility | Resistive, capacitive, and reactive loads |
| Protection | Short-circuit protected, over-temperature shutdown, current limiting |
| Brand | Wisman |
|---|---|
| Model | AMH |
| Output Voltage | ±60 kV (DC or AC peak) |
| Output Current | ±10 mA (DC or AC peak) |
| Power Rating | 600 W |
| Input Signal Range | ±10 V DC or AC peak |
| Input Impedance | 25 kΩ |
| DC Voltage Gain | 6000 V/V |
| Gain Accuracy | < 0.1% of full scale |
| Output Noise | < 10 V RMS |
| Slew Rate | > 350 V/µs (10%–90%) |
| Large-Signal Bandwidth | DC to > 1.4 kHz |
| Small-Signal Bandwidth (−3 dB, 1% THD) | DC to > 20 Hz |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤75% RH (non-condensing) |
| Altitude | ≤2000 m |
| Dimensions | 1473.5 × 628.7 × 948.4 mm |
| Weight | 125–136 kg |
| Display Resolution | Voltage — 6000:1 (accuracy < 0.1% FS |
| Output Impedance | 47 Ω |
| Brand | Wisman |
|---|---|
| Origin | Shaanxi, China |
| Model | AMK |
| Output Voltage | ±5 kV (DC or AC peak) |
| Output Power | 400 W |
| Output Current | ±80 mA (DC or AC peak) |
| Gain | 500 V/V (DC) |
| Gain Accuracy | < 0.1% of full scale |
| Slew Rate | > 1000 V/µs (10–90%) |
| Small-Signal Bandwidth | DC to > 75 kHz (−3 dB) |
| Large-Signal Bandwidth | DC to > 50 kHz (1% THD) |
| Output Noise | < 0.5 V RMS (voltage), < 10 mV RMS (voltage monitor), < 30 mV RMS (current monitor) |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Input Impedance | 25 kΩ |
| Display Scale | 500:1 (voltage), 1 V/8 mA (current) |
| Dimensions | 264 mm H × 483 mm W × 635 mm D |
| Weight | 25 kg |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Max Altitude | 2000 m |
| Compliance | Designed for integration into ISO/IEC 17025-compliant laboratories and GLP/GMP-adjacent instrumentation environments |
| Application Focus | Mass spectrometry biasing, electro-optic modulation, ferroelectric poling, dielectric barrier discharge, ion beam steering |
| Brand | Wisman |
|---|---|
| Origin | Shaanxi, China |
| Model | AML |
| Output Voltage | ±7.5 kV DC or AC peak |
| Output Power | 400 W |
| Output Current | ±50 mA DC or AC peak |
| Gain | 750 V/V (DC) |
| Gain Accuracy | < 0.1% of full scale |
| Slew Rate | >1000 V/µs (10%–90%) |
| Small-Signal Bandwidth | DC to >75 kHz (−3 dB) |
| Large-Signal Bandwidth | DC to >15 kHz (1% THD) |
| Output Noise | <0.5 V RMS (voltage), <10 mV RMS (voltage monitor), <30 mV RMS (current monitor) |
| Stability | <50 ppm/hr (non-cumulative) |
| Temperature Coefficient | <25 ppm/°C |
| Input Impedance | 25 kΩ |
| Display Resolution | 1000:1 (voltage), 1 V/12 mA (current) |
| Dimensions | 264 mm H × 483 mm W × 635 mm D |
| Weight | 25 kg |
| Operating Temp | 0–40 °C |
| Humidity | ≤85% RH, non-condensing |
| Altitude | ≤2000 m |
| Compliance | Designed for integration into ISO/IEC 17025-compliant labs and GLP/GMP-adjacent instrumentation environments |
| Primary Application | Mass Spectrometry Biasing, Electrostatic Actuation, Dielectric Barrier Discharge Systems |
| Brand | Wisman |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AMN |
| Price Range | USD $13,500 – $40,800 (FOB) |
| Compatible Instruments | Mass Spectrometers, Piezoelectric Actuators, Electro-Optic Modulators, Ion Beam Systems |
| Output Voltage | ±2 kV DC or AC peak |
| Output Power | 400 W |
| Output Current | ±200 mA DC / ±400 mA AC peak (50% duty cycle, 2 ms pulse width) |
| Slew Rate | >750 V/µs (10%–90%) |
| Small-Signal Bandwidth | DC to >100 kHz (−3 dB) |
| Large-Signal Bandwidth | DC to >60 kHz (3% THD) |
| Voltage Gain | 200 V/V (DC), Accuracy: ±0.1% of full scale |
| Input Impedance | 25 kΩ |
| Output Noise | <0.5 V RMS (voltage), <10 mV RMS (monitor), <30 mV RMS (current monitor) |
| Stability | <50 ppm/hr (non-cumulative) |
| Tempco | <25 ppm/°C |
| Operating Temp | 0–40 °C |
| Humidity | ≤85% RH, non-condensing |
| Altitude | ≤2000 m |
| Dimensions | 264 × 483 × 635 mm (H×W×D) |
| Weight | 25 kg |
| Display Resolution | Voltage monitor ratio 200:1, current monitor 0.025 V/mA |
| Protection | Four-quadrant active output, short-circuit protection, thermal shutdown |
| Brand | Wisman |
|---|---|
| Model | AMR |
| Output Voltage Range | ±20 kV (DC or AC peak) |
| Output Power | 20 W |
| Output Current Range | ±2 mA (DC or AC peak) |
| Input Voltage | 220 VAC ±10% |
| Input Current | 1 A |
| DC Voltage Gain | 1000 V/V |
| Gain Accuracy | < 0.1% of full scale |
| Output Noise | < 2 mV RMS (voltage), < 10 mV RMS (current) |
| Slew Rate | > 35 V/µs (10%–90%) |
| Small-Signal Bandwidth | DC to 10 kHz (−3 dB) |
| Large-Signal Bandwidth | DC to 1.2 kHz (1% THD) |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Altitude Rating | ≤2000 m |
| Dimensions | 88 mm H × 432 mm W × 439 mm D |
| Weight | 7 kg |
| Input Impedance | 25 kΩ (non-inverting input) |
| Output Impedance | 47 Ω |
| Voltage Display Scale | 1000:1 (accuracy < 0.1% FS) |
| Current Display Scale | 1 V / 0.8 mA (accuracy < 0.5% FS) |
| Short-Circuit Protection | Active, programmable |
| Quadrants | Four-quadrant active output (sourcing & sinking) |
| Load Compatibility | Resistive, capacitive, and reactive loads |
| Compliance | CE-marked |
| Brand | Wisman |
|---|---|
| Model | AMS |
| Output Voltage Range | ±5 kV (DC or AC peak) |
| Output Power | 40 W |
| Output Current Range | ±8 mA (DC or AC peak) |
| Slew Rate | >35 V/μs (10%–90%) |
| Small-Signal Bandwidth | DC to 35 kHz (−3 dB) |
| Large-Signal Bandwidth | DC to 6 kHz (1% THD) |
| Voltage Gain | 500 V/V (±0.1% of FS accuracy) |
| Output Noise | <2 mV RMS (voltage), <10 mV RMS (current) |
| Input Impedance | 25 kΩ (non-inverting) |
| Stability | <50 ppm/h (non-cumulative) |
| Tempco | <25 ppm/°C |
| Operating Temp | 0–40 °C |
| Humidity | ≤85% RH (non-condensing) |
| Altitude | ≤2000 m |
| Dimensions | 88 × 432 × 439 mm |
| Weight | 7 kg |
| Compliance | Designed for integration with mass spectrometers and high-precision electrostatic instrumentation |
| Input | 220 VAC ±10%, 1 A |
| Brand | Wisman |
|---|---|
| Model | AMU |
| Output Voltage Range | ±10 kV DC or AC peak |
| Output Power | 400 W |
| Output Current Range | ±40 mA DC or AC peak |
| Slew Rate | >900 V/µs |
| Small-Signal Bandwidth | DC to >25 kHz (−3 dB) |
| Large-Signal Bandwidth | DC to >9 kHz (1% THD) |
| Voltage Gain | 1000 V/V (±0.1% FS accuracy) |
| Output Noise | <0.5 V RMS (voltage), <10 mV RMS (monitored), <30 mV RMS (current monitor) |
| Stability | <50 ppm/hr (non-cumulative) |
| Temperature Coefficient | <25 ppm/°C |
| Input Impedance | 25 kΩ |
| Display Resolution | 1000:1 (voltage), 1 V/12 mA (current) |
| Dimensions | 264 mm H × 483 mm W × 635 mm D |
| Weight | 25 kg |
| Compliance | Designed for laboratory-grade instrumentation in regulated R&D environments |
| Brand | Wisman |
|---|---|
| Model | AMV |
| Output Voltage | ±20 kV DC or AC peak |
| Output Power | 400 W |
| Output Current | ±20 mA DC or AC peak |
| Input Voltage Range | 0 to ±10 V DC or AC peak |
| Gain | 2000 V/V (DC) |
| Gain Accuracy | Better than 0.1% of full scale |
| Output Noise | <1.5 V RMS |
| Slew Rate | >800 V/µs (10%–90%) |
| Large-Signal Bandwidth | DC to >5.2 kHz (1% THD) |
| Small-Signal Bandwidth | DC to >20 kHz (−3 dB) |
| Stability | <50 ppm/hr (non-cumulative) |
| Temperature Coefficient | <25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Humidity | ≤85% RH, non-condensing |
| Altitude | Up to 2000 m |
| Dimensions | 264 × 483 × 635 mm (H×W×D) |
| Weight | 25 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Voltage Display Ratio | 2000:1 |
| Voltage Display Accuracy | Better than 0.1% FS |
| Voltage Offset | <±2 mV |
| Current Display Ratio | 1 V / 6 mA |
| Current Display Accuracy | >0.5% FS |
| Current Offset | <±10 mV |
| Current Noise | <30 mV RMS |
| Brand | Wisman |
|---|---|
| Origin | Shaanxi, China |
| Model | DA60P2 |
| Output | 0.5–100 kV DC, 2 kW |
| Ripple | 0.1% P-P + 1 Vrms |
| Stability | <100 ppm/h after 30-min warm-up |
| Temp. Coefficient | 100 ppm/°C |
| Control Interface | RS-232 (standard), RS-422 (optional) |
| Input | AC 220 V ±10%, 15 A |
| Dimensions (2 kW, ≤70 kV) | 132 mm H × 483 mm W × 483 mm D (3U 19″ rack) |
| (80–100 kV) | 132 mm H × 483 mm W × 610 mm D |
| Safety | Overvoltage, overcurrent, short-circuit, arc detection, overtemperature, interlock |
| Compliance | CE certified |
| Key | Brand: Wisman |
|---|---|
| Origin | Shaanxi, China |
| Model | DC150 |
| Output Voltage | 0–130 kV (adjustable) |
| Output Power | 2 kW |
| Ripple | 0.02% p-p (customizable to 0.01% p-p) |
| Stability | <100 ppm/h (after 30-min warm-up), <500 ppm/8 h |
| Temperature Coefficient | ≤25 ppm/°C |
| Input | AC 220 V ±10% (AC 110 V optional), PF = 0.995, Efficiency = 85% |
| Protection | Overvoltage, Overcurrent, Short-Circuit, Arc Detection, Overtemperature, Interlock |
| Interfaces | RS-232, Ethernet (standard), RS-485 (optional) |
| Compliance | CE certified |
| Dimensions | 483 mm W × 610 mm D × 44 mm H (1U, for 80–130 kV models) |
| Application | Ion implantation, particle accelerators, X-ray tubes, electrostatic processes, scientific research |
| Brand | Wisman |
|---|---|
| Origin | Shaanxi, China |
| Model | DEA |
| Output Voltage | 10 kV |
| Output Power | 20 W |
| Input Voltage | 220 VAC ±10% |
| Stability | <0.01%/hr (after 30-min warm-up), <0.02%/8 hr |
| Temperature Coefficient | <25 ppm/°C (optional 10 ppm/°C with TC10) |
| Ripple | Ultra-low (see DEA Selection Table) |
| Voltage Programming | Differential analog input (±10 VDC reference) |
| Interface Options | RS-232, RS-485, Ethernet |
| Protection | Overcurrent, arc detection, continuous short-circuit |
| Control Modes | Local front-panel, remote analog/digital, computer-hosted |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −35–85 °C |
| Humidity | 20–85% RH (non-condensing) |
| Compliance | Designed for integration into analytical instrumentation per IEC 61010-1 safety requirements |
| Brand | Wisman |
|---|---|
| Origin | Shaanxi, China |
| Model | DEC |
| Output Voltage Range | 0.5–70 kV (adjustable) |
| Output Current Range | 0–100 mA |
| Maximum Output Power | 200 W |
| Input Voltage | 85–256 VAC, 10 A |
| Ripple | 0.1% p-p + 1 Vrms |
| Stability | <0.01% per hour (after 30 min warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Voltage/Current Control | Local (multi-turn potentiometer), Remote (0–10 V analog), Digital (USB 2.0, RS-232, RS-422) |
| Protection | Overvoltage, Short-Circuit, Arc Detection, Safety Interlock |
| Dimensions | 410 × 170 × 170 mm |
| Weight | 4.5–10 kg |
| Compliance | Designed for laboratory-grade stability and safety in regulated R&D environments |
| Brand | Wisman |
|---|---|
| Model | DEL |
| Output Voltage Range | 0.5–50 kV (adjustable) |
| Output Current Range | 0–50 mA |
| Max Output Power | 100 W |
| Ripple | ≤0.1% pk-pk (at rated voltage) |
| Stability | <0.02% per 8 hours (after 30-min warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Input | 86–256 VAC ±10%, 3 A |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Dimensions | 240 × 130 × 140 mm |
| Weight | 3.0–5.65 kg |
| Remote Control Interface | 0–10 V analog (voltage & current) via DB15 connector |
| Safety Features | Overvoltage protection, short-circuit protection, arc detection, interlock input |
| Brand | Wisman |
|---|---|
| Model | DG |
| Output Voltage | Up to 225 kV DC |
| Output Power | 100 kW |
| Ripple | 0.1% P-P + 1 Vrms |
| Stability | <100 ppm/h (after 30 min warm-up) |
| Temperature Coefficient | 25 ppm/°C |
| Control Interfaces | Standard Ethernet & RS-232, Optional RS-485 |
| Protection | Overvoltage, Overcurrent, Short-Circuit, Arc Detection, Overtemperature, Safety Interlock |
| Compliance | CE Certified |
| Dimensions (225 kV variant) | 356 mm H (8U) × 483 mm W × 1168 mm D |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Display | 4-digit LED panel meter (±1% accuracy at rated output) |
| Remote Control | 0–10 V analog for voltage/current setpoint and monitoring |
| Customization | Available for HV polarity, output regulation mode (e.g., CPC constant power), and mechanical integration |
| Brand | Wisman |
|---|---|
| Model | HEM |
| Output Voltage | −35 kV (Accelerator) |
| Output Current | 450 µA |
| Input | DC 24 V |
| Ripple | 70 mV<sub>P-P</sub> (0.1 Hz–1 MHz) |
| Line Regulation | ±100 mV (±10% input variation) |
| Load Regulation | ±0.01% |
| Stability | 1.5 V/10 h (after 2-h warm-up) |
| Tempco | 25 ppm/°C |
| Filament Supply | 0–5 V / 0–5 A |
| Suppressor Supply | −10 V to −2 kV / 300 µA |
| Extractor Supply | 0 to −15 kV / 400 µA |
| Interface | RS-232, Ethernet |
| Compliance | Designed for OEM integration in vacuum-based analytical instrumentation |
| Brand | Wisman |
|---|---|
| Model | MRD |
| Output Voltage | 160 kV |
| Output Power | 1200 W |
| Input Voltage Range | 180–264 VAC, 47–63 Hz |
| Ripple | ≤0.1% P-P (≤20 kHz) |
| Stability | ≤0.02% per 8 hours |
| Temperature Coefficient | 25 ppm/°C |
| Control Interfaces | USB 2.0, RS-422, Analog 0–10 V |
| Polarity | Selectable Positive or Negative |
| Protection | Overvoltage, Overcurrent, Arc Detection, Safety Interlock |
| Compliance | Designed for OEM integration in analytical instrumentation environments |
| Application | Mass Spectrometry (MS) Systems |
| Brand | Wisman |
|---|---|
| Output Voltage | 0–100 kV (selectable polarity) |
| Output Power | 200 W |
| Ripple & Noise | ≤0.1% P-P (of rated output voltage) |
| Stability | ≤0.02% per 8 hours |
| Temperature Coefficient | ≤25 ppm/°C |
| Control Interfaces | Analog 0–10 V, USB 2.0, RS-232, RS-422 |
| Protection | Overvoltage, Overcurrent, Arc Detection, Interlock |
| Input | AC/DC selectable, max 8 A |
| Operating Temp. | 0–50 °C |
| Dimensions (100 kV variant) | 405 mm × 190 mm × 155 mm |
| Cooling | Convection |
| Compliance | Designed for OEM integration in analytical and scientific instrumentation |
| Key | Brand: Wisman |
|---|---|
| Origin | Shaanxi, China |
| Form Factor | 19″ Rack-Mount (6U) |
| Channels | 10 Independent |
| Max. Voltage per Channel | 1–70 kV |
| Max. Power per Channel | 100 W |
| Total Rated Power | 1200 W |
| Input | AC 220 V ±10%, 50/60 Hz |
| Output Ripple | 0.1% P-P (customizable lower) |
| Voltage Stability | ≤100 ppm/h, ≤500 ppm/8 h |
| Temp. Coefficient | ≤25 ppm/°C |
| Control Interface | Local (front-panel potentiometers + 4-digit LED displays) & Remote (RS-485) |
| Protections | OVP, OCP, SCP, Arc Detection, Overtemperature, Safety Interlock |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Wisman |
|---|---|
| Origin | Shaanxi, China |
| Model | MSB |
| Output Channels | Up to 512 (configurable 2–512) |
| Output Voltage Range | 1–30 kV DC |
| Output Power per Channel | 2–20 W |
| Ripple Voltage | < 2 ppm (typ. 10 mV) |
| Stability | 10 ppm/hour, 20 ppm/8 hours, 100 ppm/1000 hours |
| Temperature Coefficient | ≤10 ppm/°C |
| Input | AC 220 V ±5% |
| Communication Interface | RS-485 (standard) |
| Protection | Overcurrent, Arc Detection, Short-Circuit |
| Compliance | Designed for GLP/GMP-aligned instrumentation environments |
| Application Domain | Mass Spectrometry, PMT Biasing, Solid-State Detectors, Electrophoresis, ESD Testing, Semiconductor Characterization, and Precision Electrostatic Systems |
| Brand | Wisman |
|---|---|
| Model | PRC |
| Output Voltage Range | ±5 kV to ±30 kV (selectable) |
| Output Power | 5 W – 10 W |
| Polarity Reversal Time | 8 ms to 1 s (configurable) |
| Ripple | ≤0.001% Vp-p |
| Voltage Stability | 0.01%/hr (after 1-hr warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Line & Load Regulation | ±0.01% |
| Input | 24 VDC ±10% |
| Interface Options | RS-232, RS-422, USB 2.0 (optional) |
| Dimensions | 89 × 127 × 254 mm (H × W × D) |
| Weight | 4.45 kg |
| Compliance | Designed for OEM integration in regulated scientific instrumentation environments |