Other Measurement Instruments
Filter
Showing 571–600 of 857 results
| Brand | OPHIR |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluxGage |
| Pricing | Upon Request |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Model | L100(500)A-PF-120 |
| Aperture Diameter | 120 mm |
| Spectral Range | 0.19–20 µm |
| Power Range | 20 W–120 kW |
| Position Accuracy | ±0.1 mm |
| Beam Size Accuracy | ±5% |
| Cooling | Active Water Cooling |
| Calibration | Multi-wavelength NIST-traceable |
| Compatible Meters | Vega, Nova II, StarLite, Juno Interface |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Model | PD10/30A-P-RP series |
| Sensor Types | Photodiode & Pyroelectric Energy Sensors, RP (Real-time Pulse) Sensors |
| Wavelength Range | 0.15–20 µm (depending on model) |
| Energy Range | 10 pJ – 40 J |
| Avg. Power Range | 30 mW – 1500 W |
| Max. Repetition Rate | 25 kHz |
| Aperture Sizes | Φ10 mm to Φ96 mm |
| Compliance | ISO 17025 traceable calibration, CE, RoHS |
| Brand | Optomet |
|---|---|
| Origin | Germany |
| Model | Vector-Micro |
| Laser Wavelength | 632 nm |
| Spot Diameter | ~3 µm |
| Frequency Range | 0–25 MHz |
| Integrated Camera | 12 MP (4K resolution) |
| Application Domain | MEMS, microelectronics, precision microstructure vibration analysis |
| Compliance | Designed for ISO 18431-1, ISO 2041, and ASTM E1876-compliant modal testing workflows |
| Software Architecture | Native support for GLP/GMP audit trails, FDA 21 CFR Part 11–compliant data handling |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | OL 345 |
| Pricing | Upon Request |
| Spectral Irradiance @ 650 nm | 0.6 DW/cm²·nm (typical) |
| Spectral Radiance @ 650 nm | 0.45 DW/sr·cm²·nm (typical) |
| Illuminance @ 6.500 A | 24 fc (typical) |
| Luminance @ 6.500 A | 65 fL (typical) |
| Radiometric Accuracy | ±2% @ 650 nm, ±4% @ 250 nm |
| Photometric Accuracy | ±1% |
| Stability | ≤±1% drift over 50 hours |
| Lamp Power | 45 W (6.500 A) |
| Diameter | 5 inches |
| Spectral Range (Irradiance Mode) | 250–2500 nm |
| Spectral Range (Radiance/Luminance Mode) | 350–1100 nm |
| Uniform Area (with opal diffuser) | 15.5 cm² |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | OL 410 |
| Power Ratings | 150 W (OL 410-150), 200 W (OL 410-200), 1000 W (OL 410-1000) |
| Current Accuracy | ±0.02% of reading |
| Current Resolution | 0.001 A |
| Short-Term Stability | ≤10 ppm |
| Temperature Coefficient | ≤25 ppm/°C |
| Ramp Control | Programmable current rise/fall profiles |
| Lamp Memory | 10 independent lamp profiles with calibration metadata and elapsed-time tracking |
| Calibration Mode | Three-point low-current correction |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL 752-10 / OL 752-12 |
| Spectral Range (OL 752-10) | 250–2500 nm |
| Spectral Range (OL 752-12) | UV-dominated, optimized for 200–400 nm |
| Lamp Type | Tungsten-halogen (OL 752-10), Deuterium (OL 752-12) |
| Mounting | Integrated, factory-aligned collimated output with protective shutter cap |
| Compliance | NIST-traceable calibration certificates supplied per unit |
| Brand | OSEN |
|---|---|
| Model | OSEN-ZSW-03 |
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | PRC |
| Unit Price | USD 2,800 (FOB Shenzhen, subject to configuration and volume) |
| Brand | Pall |
|---|---|
| Model | WS19 |
| Type | Portable Capacitive Moisture-in-Oil Sensor |
| Measurement Principle | Dielectric Constant-Based Water Activity (aw) and ppm Detection |
| Dimensions | 62 mm W × 170 mm L × 34 mm D (2.4″ × 6.7″ × 1.3″) |
| Weight | 0.21 kg (0.45 lb) |
| Battery Life | Up to 200 hours |
| Operating Temperature | Probe: −40°C to +120°C (−40°F to +248°F) |
| Controller & Display Unit | 0°C to +50°C (32°F to 122°F) |
| Probe Cable Length | 2 m (6.6 ft) |
| Fluid Compatibility | Mineral oils, synthetic hydrocarbons, polyalphaolefins (PAOs), diesters, and phosphate esters *excluding aerospace-grade phosphate esters* |
| Accuracy | ±2% RH (0–90% RH), ±3% RH (90–100% RH) |
| Traceability | NIST-, PTB-, and BEV-traceable calibration |
| Compliance | IEC 61326-1:2005, IEC 61326-2-1:2005, EN 61326-1:2006 |
| Brand | Peric |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Customized Sub-Metering Electricity Monitoring & Regulatory Platform |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GRS-Fxx |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | FlowMark 1000 |
| Flow Range | 0.1–1000 mL/min |
| Accuracy | ±3% of reading or ±0.05 mL/min (whichever is greater) |
| Operating Temperature | 0–45 °C |
| Calibration Traceability | NIST-traceable |
| Display | Alphanumeric LCD |
| Power Supply | 9 V battery (also compatible with 2 × AA batteries per variant specifications) |
| Compliance | CE, ATEX/IECEx Ex-certified (for hazardous areas), RoHS, WEEE |
| Gas Compatibility | Clean, dry, non-corrosive, non-flammable gases only |
| Data Interface | USB port |
| Auto-power-off | Yes |
| Enclosure | Ergonomic handheld housing with side-grip design |
| Warranty | 1 year |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 270 |
| Measurement Range | 1 × 10⁻⁴ to 1000 hPa |
| Accuracy | ±10 % |
| Operating Temperature | up to 80 °C |
| Maximum Pressure Resistance | 400 kPa |
| Weight | 135 g |
| Flange Options | DN 16 ISO-KF, DN 16 CF-F |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ActiveLine |
| Pressure Range | 10⁻¹¹ to 55,000 mbar |
| Output Signal | 0–10 V analog with integrated error diagnostics |
| Interface | Integrated measurement interface |
| Mounting Options | DN 16, DN 25/40, G 1/4″ |
| Operating Temperature | +5 °C to +60 °C (varies by sensor type) |
| Sensor Types | APR (Pirani), CMR (Capacitance Manometer), TPR (Combined Pirani/Thermocouple), PKR/IKR (Cold Cathode Ionization), PBR/IMR (Hot Cathode Ionization) |
| Pressure Units | Selectable (mbar, Pa, Torr, psi, etc.) |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU |
| Software Integration | Compatible with Pfeiffer Vacuum Control Suite and third-party SCADA/PLC systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Calibration System Pro |
| Calibration Range | 1013 hPa to 10⁻³ hPa |
| Flange Configuration | PS A30 110 (4×DN 16 ISO-KF, 2×DN 25 ISO-KF, 1×DN 40 ISO-KF, 1×DN 40 CF) / PS A30 111 (5×DN 16 ISO-KF, 2×DN 25 ISO-KF, 2×DN 40 ISO-KF) |
| Nitrogen Pumping Speed | 67 L/s |
| Forevacuum Pump Speed (50 Hz) | 2.5 m³/h |
| Ultimate Pressure | < 1 × 10⁻⁷ hPa |
| Gas Flow Control Range | 5 × 10⁻⁶ to 1 × 10³ hPa·L/s |
| Operating Temperature | +5 °C to +40 °C (cooling-dependent) |
| Weight | 66 kg (standard configuration) |
| Dimensions (L×W×H) | 700 × 639 × 593 mm |
| Compliance | ISO 3567, DAkkS-DKD-R 6-2, EN ISO 12100, EN 60204-1, CE (2006/42/EC & 2014/30/EU) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Digiline |
| Sensor Types | CPT200 / PPT200 / RPT200 / HPT200 / MPT200 |
| Measurement Range | 5×10⁻¹⁰ to 2×10³ mbar (model-dependent) |
| Operating Temperature | +5 °C to +50 °C |
| Enclosure Rating | IP54 |
| Electrical Interface | DIN M12 connector, RS-485 serial communication (Pfeiffer protocol), no RS-232 |
| Display | Backlit graphical LCD |
| Output Options | Analog (0–10 V or 4–20 mA), dual relay switch points |
| Compliance | Designed for integration into industrial vacuum systems per DIN/ISO standards |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 251 |
| Vacuum Interface | DN 25 ISO-KF, DN 40 ISO-KF, DN 40 CF-F |
| Measurement Range | 2 × 10⁻⁹ to 0.01 hPa |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | 150 °C |
| Accuracy | ±30 % |
| Ultimate Pressure | 10,000 hPa (atmospheric withstand) |
| Weight | 700 g |
| Output Signal | 0–10 V analog |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 251 |
| Measurement Principle | Cold Cathode Ionization |
| Range | 2×10⁻⁹ – 10⁻² hPa |
| Vacuum Interface | DN 25 ISO-KF / DN 40 ISO-KF / DN 40 CF-F |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | 150 °C |
| Accuracy | ±30 % |
| Output Signal | 0–10 V analog |
| Weight | 700 g |
| Sealing | FPM (Viton®) elastomer |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 361 / IKR 362 |
| Measurement Principle | Inverted Magnetron |
| Pressure Range | 1 × 10⁻⁹ hPa |
| Vacuum Flanges | DN 25 ISO-KF, DN 40 ISO-KF, DN 40 CF-F |
| Construction | Metal Seals (No Elastomer), Dual-Chamber Design |
| Optional Variants | Corrosion-Resistant Version, Low-Field / High-Current Configurations |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ModuLine Gauge |
| Interface Options | PROFIBUS |
| Sensor Types | Capacitance Manometer (TPR series), Cold Cathode Ionization Gauge (IKR series) |
| Operating Temperature Range | –40 °C to +80 °C |
| Weight | 0.14–0.65 kg |
| Vacuum Range | 10⁻¹¹ mbar to 10³ mbar (depending on sensor module) |
| Sealing | Metal-sealed variants available |
| Radiation & EMI Resistance | Yes |
| Application Domain | Particle accelerator beamlines, UHV/XHV research systems, industrial vacuum process monitoring |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniControl |
| Measurement Principle | Vacuum Pressure Monitoring and Pump Control via RS-485 and Analog Interfaces |
| Enclosure Rating | IP20 |
| Operating Temperature | 0°C to +50°C |
| Power Supply Options | 100–240 V AC ±10%, 47–63 Hz |
| Power Consumption | 300 W (OmniControl 200) / 411 W (OmniControl 300) / 522 W (OmniControl 400) |
| Output Voltages | 24 V DC (200/300) or 48 V DC (400) |
| Max Output Current | 11.4 A (200) / 15 A (300) / 8.33 A (400) |
| Display | 3.5-inch capacitive touchscreen |
| Mounting Options | Rack-mountable, desktop, or portable configurations |
| Compliance | Designed for integration with Pfeiffer Vacuum RS-485–enabled pumps (HiPace, HiScroll, HiLobe, MVP) and digital vacuum gauges |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PCR 280 |
| Measurement Principle | Capacitance manometry with integrated Pirani sensor |
| Range | 5 × 10⁻⁵ to 1500 hPa |
| Vacuum Port Options | DN 16 ISO-KF, DN 16 CF-F, or custom flange |
| Operating Voltage | 15–30 V DC |
| Output Signal | 1.2–8.68 V analog |
| Bakeout Temperature | 80 °C |
| Accuracy | ±50% (5 × 10⁻⁴–1 × 10⁻³ hPa), ±15% (1 × 10⁻³–100 hPa), ±5% (100–950 hPa), ±2.5% (950–1100 hPa) |
| Ultimate Pressure | 5000 hPa (overpressure limit) |
| Weight | 120 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 251 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa |
| Vacuum Interfaces | KF 25, CF 40, KF 40 |
| Accuracy | ±30% (1×10⁻⁸ to 100 hPa) |
| Repeatability | ±5% |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | up to 150 °C |
| Power Supply | 15.0–30.0 V DC |
| Max. Power Consumption | ~2 W |
| Output Signal | 0–10.5 V analog voltage |
| Weight | ~700 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 361 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa (calibrated for air or N₂) |
| Vacuum Port Options | KF 25, CF 40, KF 40 |
| Repeatability | ±1% of reading (1×10⁻⁸ to 100 hPa) |
| Bakeout Temperature | ≤150 °C |
| Anode Material | Molybdenum |
| Flange Material | 1.4435 stainless steel |
| Compliance | CE, RoHS, EN 61326-1 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR251 |
| Measurement Principle | Integrated Pirani and Cold Cathode Gauge |
| Range | 5×10⁻⁹ to 1000 hPa (air/N₂) |
| Vacuum Port | DN25 ISO-KF, DN40 ISO-KF, DN40 CF-F |
| Max. Absolute Pressure | 10,000 hPa (inert gases, <55 °C) |
| Accuracy | ±30% (1×10⁻⁸–100 hPa) |
| Repeatability | ±5% (1×10⁻⁸–100 hPa) |
| Output Signal | 0–10.5 V analog |
| Supply Voltage | 15.0–30.0 V DC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPG 201 |
| Measurement Principle | Pirani (thermal conductivity) |
| Pressure Range | 1000 to 5 × 10⁻⁴ hPa |
| Vacuum Interface | KF 16 |
| Operating Temperature | 5 to 40 °C |
| Accuracy | ±30 % at 10–100 hPa |
| Display | Integrated LCD |
| Power Supply | Rechargeable battery or external stabilized DC supply |
| Weight | 0.195 kg |
| Housing Material | Corrosion-resistant stainless steel |
| Heating Option | Available for low-outgassing and UHV-compatible operation |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 |
| Measurement Principle | Pirani |
| Range | 5 × 10⁻⁴ to 1000 hPa |
| Vacuum Interface | KF 16 (DN 16 ISO-KF) |
| Output Signal | 2.2–8.5 V DC |
| Supply Voltage | 14–30 V DC |
| Filament Material | Tungsten |
| Housing Material | Stainless Steel |
| Electrical Feedthrough | Glass |
| Operating Temperature | 5–60 °C |
| Bakeout Temperature | 80 °C (250 °C optional) |
| Accuracy | ±15% of reading (10⁻³–100 hPa) |
| Repeatability | ±2% of reading (10⁻³–100 hPa) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 / TPR 281 |
| Measurement Range | 1.0 × 10³ hPa to 5.0 × 10⁻⁴ hPa |
| Operating Temperature | 80 °C (standard) / 250 °C (high-temp version) |
| Accuracy | ±15 % of reading |
| Burst Pressure | 1000 kPa |
| Weight | 80 g (TPR 280, standard) / 130 g (TPR 280, high-temp) / 80 g (TPR 281, corrosion-resistant) |
| Flange Options | DN 16 ISO-KF, DN 16 CF, 1/8" NPT, 8 VCR |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR280 |
| Measurement Principle | Pirani thermal conductivity gauge |
| Range | 5 × 10⁻⁴ – 1000 hPa |
| Vacuum Port Options | DN16 ISO-KF, DN16 CF-R, 1/8" NPT, 8 VCR |
| Operating Temperature | 80 °C or 250 °C (depending on version) |
| Accuracy | ±15 % of reading |
| Maximum Pressure Resistance | 1000 kPa |
| Output Signal | 0–10 V analog |
| Weight | 80 g (80 °C version, DN16 ISO-KF) / 130 g (250 °C version, DN16 ISO-KF) |
| Brand | PH-Instruments |
|---|---|
| Origin | Germany |
| Model | DosiTorr SRG |
| Measurement Principle | Gas molecule adsorption/desorption-induced rotor deceleration, quantified via rotational decay rate |
| Pressure Range | 10 mbar to 5×10⁻⁷ mbar |
| Vacuum Interface | Designed for direct replacement of ionization gauges with plug-and-play electrical compatibility |