| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 361 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa (calibrated for air or N₂) |
| Vacuum Port Options | KF 25, CF 40, KF 40 |
| Repeatability | ±1% of reading (1×10⁻⁸ to 100 hPa) |
| Bakeout Temperature | ≤150 °C |
| Anode Material | Molybdenum |
| Flange Material | 1.4435 stainless steel |
| Compliance | CE, RoHS, EN 61326-1 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR251 |
| Measurement Principle | Integrated Pirani and Cold Cathode Gauge |
| Range | 5×10⁻⁹ to 1000 hPa (air/N₂) |
| Vacuum Port | DN25 ISO-KF, DN40 ISO-KF, DN40 CF-F |
| Max. Absolute Pressure | 10,000 hPa (inert gases, <55 °C) |
| Accuracy | ±30% (1×10⁻⁸–100 hPa) |
| Repeatability | ±5% (1×10⁻⁸–100 hPa) |
| Output Signal | 0–10.5 V analog |
| Supply Voltage | 15.0–30.0 V DC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPG 201 |
| Measurement Principle | Pirani (thermal conductivity) |
| Pressure Range | 1000 to 5 × 10⁻⁴ hPa |
| Vacuum Interface | KF 16 |
| Operating Temperature | 5 to 40 °C |
| Accuracy | ±30 % at 10–100 hPa |
| Display | Integrated LCD |
| Power Supply | Rechargeable battery or external stabilized DC supply |
| Weight | 0.195 kg |
| Housing Material | Corrosion-resistant stainless steel |
| Heating Option | Available for low-outgassing and UHV-compatible operation |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 |
| Measurement Principle | Pirani |
| Range | 5 × 10⁻⁴ to 1000 hPa |
| Vacuum Interface | KF 16 (DN 16 ISO-KF) |
| Output Signal | 2.2–8.5 V DC |
| Supply Voltage | 14–30 V DC |
| Filament Material | Tungsten |
| Housing Material | Stainless Steel |
| Electrical Feedthrough | Glass |
| Operating Temperature | 5–60 °C |
| Bakeout Temperature | 80 °C (250 °C optional) |
| Accuracy | ±15% of reading (10⁻³–100 hPa) |
| Repeatability | ±2% of reading (10⁻³–100 hPa) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 / TPR 281 |
| Measurement Range | 1.0 × 10³ hPa to 5.0 × 10⁻⁴ hPa |
| Operating Temperature | 80 °C (standard) / 250 °C (high-temp version) |
| Accuracy | ±15 % of reading |
| Burst Pressure | 1000 kPa |
| Weight | 80 g (TPR 280, standard) / 130 g (TPR 280, high-temp) / 80 g (TPR 281, corrosion-resistant) |
| Flange Options | DN 16 ISO-KF, DN 16 CF, 1/8" NPT, 8 VCR |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR280 |
| Measurement Principle | Pirani thermal conductivity gauge |
| Range | 5 × 10⁻⁴ – 1000 hPa |
| Vacuum Port Options | DN16 ISO-KF, DN16 CF-R, 1/8" NPT, 8 VCR |
| Operating Temperature | 80 °C or 250 °C (depending on version) |
| Accuracy | ±15 % of reading |
| Maximum Pressure Resistance | 1000 kPa |
| Output Signal | 0–10 V analog |
| Weight | 80 g (80 °C version, DN16 ISO-KF) / 130 g (250 °C version, DN16 ISO-KF) |
| Brand | PH-Instruments |
|---|---|
| Origin | Germany |
| Model | DosiTorr SRG |
| Measurement Principle | Gas molecule adsorption/desorption-induced rotor deceleration, quantified via rotational decay rate |
| Pressure Range | 10 mbar to 5×10⁻⁷ mbar |
| Vacuum Interface | Designed for direct replacement of ionization gauges with plug-and-play electrical compatibility |
| Brand | ph-instruments |
|---|---|
| Origin | Germany |
| Model | ION Check |
| Measurement Principle | Spinning Rotor Gauge (SRG) |
| Range | 5 × 10⁻⁷ mbar to 1 × 10⁻² mbar (up to 1 mbar max) |
| Vacuum Interface | KF25 (adapters available for other standards) |
| Accuracy | ±1% of reading from 0.1 mbar to 1 × 10⁻⁶ mbar |
| Long-term Stability | <1% per year |
| Calibration Channels | Dual parallel |
| Pumping System | Oil-free turbomolecular pump + diaphragm backing pump |
| Data Interfaces | USB-C, LAN, RS-485, optional Bluetooth |
| Control Interface | 10-inch touchscreen, Windows 10, dedicated ION Check software |
| Power Supply | 230 VAC, 50 Hz, <2 A |
| Operating Temperature | 10–40 °C |
| Dimensions | 610 × 610 × 1200 mm |
| Weight | 90.8 kg |
| Brand | ph-instruments |
|---|---|
| Origin | Germany |
| Model | VIM-2 Portable Spinning Rotor Gauge |
| Measurement Principle | Momentum exchange due to gas molecule adsorption/desorption |
| Range | 10 mbar to 5×10⁻⁷ mbar |
| Vacuum Interface | USB Type-C / Bluetooth / High-density 15-pin D-sub |
| Accuracy | ±10% (10 mbar – 0.1 mbar), ±1% (0.1 mbar – 1×10⁻⁶ mbar) |
| Long-term Drift | <1% per year |
| Sensor Material | Stainless steel 1.4404 / 1.4034 |
| Operating Temperature (Electronics) | 10–40 °C |
| Sensor Max Temp (Metal Seal) | 450 °C |
| Power Supply | 18–28 VDC, Li-ion battery (>2 h operation) |
| Data Storage | 1023 internal records |
| Output | 0–10 VDC (configurable) |
| Weight | Host 1650 g, Measuring Head 750 g, Adapter 510 g |
| [Brand | Phasics |
|---|---|
| Origin | France |
| Technology | 4-Wave Lateral Shearing Interferometry |
| Wavelength Ranges | UV (190–400 nm), VIS-NIR (350–1100 nm), SWIR (0.9–1.7 µm), NIR (1.5–1.6 µm), MWIR/LWIR (3–5 µm & 8–14 µm) |
| Spatial Resolution | up to 250 × 250 points |
| Dynamic Range | >500 µm |
| Accuracy | ≤10 nm RMS (UV/VIS/NIR/SWIR variants) |
| Frame Rate | up to 60 fps |
| Aperture Size | up to 13.44 × 10.08 mm² |
| Compliance | ISO 10110-5, ISO 21246, ASTM E2815, supports GLP/GMP audit trails via software export] |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | photoLab® 7100 VIS |
| Wavelength Range | 320–1100 nm |
| Optical Design | Dual-Beam Reference Channel |
| Light Source | Xenon Pulse Lamp |
| Display | High-Resolution Color TFT Touchscreen |
| Connectivity | USB, Ethernet, PDF Export |
| Software | SpectroLab Data Management Suite (GLP-Compliant) |
| Compliance | ISO/IEC 17025, ASTM E275, USP <857>, FDA 21 CFR Part 11 Ready |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 2D2CPIV |
| Measurement Capability | Planar (2D/3D) Velocity Field |
| Operating Frequency | Low-Frequency (≤15 Hz) |
| Velocity Range | 0–1500 m/s |
| Accuracy | ±3% of reading |
| Measurement Area | ≥400 mm × 400 mm |
| Core Components | PCO edge 5.5M dual-frame camera, dual-cavity double-pulse Nd:YAG laser (532 nm), nanosecond-precision synchronization controller, PIV post-processing software suite |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DGV |
| Price Range | USD 270,000 – 410,000 (based on configuration and integration support) |
| Measurement Mode | Planar (2D/3D capable) |
| Acquisition Frequency | Low-to-Medium Repetition Rate (typically 1–10 Hz for high-energy pulsed operation) |
| Velocity Range | 0–3000 m/s |
| Absolute Velocity Accuracy | ±0.8–1.4 m/s |
| Measurement Field of View | 120 mm × 120 mm |
| Core Optical Filter | Integrated Iodine Vapor Molecular Filter with Thermal Stabilization |
| Laser Source | Narrow-Linewidth Pulsed or CW Diode-Pumped Solid-State Laser (532 nm typical) |
| Detection Architecture | Dual-Camera Configuration (Signal + Reference) |
| Compliance | Designed to support GLP-compliant experimental workflows |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FRS |
| Price Range | USD 270,000 – 410,000 (based on EUR/USD exchange and landed cost) |
| Measurement Modality | Planar (2D/3D) |
| Repetition Rate | Low-Frequency (Single-Shot to ~10 Hz typical) |
| Velocity Range | 0–300 m/s |
| Velocity Uncertainty | ±0.8–1.4 m/s |
| Measurement Field of View | 120 mm × 120 mm |
| Temperature Range | 100–2000 K |
| Temperature Uncertainty | ±1% |
| Pressure Range | 0.1–20 bar |
| Pressure Uncertainty | ±3% |
| Particle-Free Operation | Yes |
| Upgrade Path | Compatible with Doppler Global Velocimetry (DGV) architecture |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR PIV |
| Price Range | USD 270,000 – 405,000 (based on configuration) |
| Measurement Mode | Planar (2D) and Volumetric (3D) |
| Frame Rate | Up to 10 kHz (full resolution), >100 Hz standard operation |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±3% of measured velocity magnitude |
| Measurement Area | ≥400 mm × 400 mm (2D) |
| Laser Source Options | High-repetition-rate pulsed Nd:YAG or LED-based illumination |
| Camera Resolution | Configurable up to 4 MP at 10 kHz |
| Synchronization Precision | <10 ns jitter |
| Software Platform | PIVtec ILA v5.x with GLP-compliant audit trail and metadata embedding |
| PMM | Brand |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMM 9180 |
| Price | Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | HP-050 |
| Frequency Range | 10 Hz – 5 kHz |
| Magnetic Flux Density Range | 10 nT – 40 µT |
| Dynamic Range | > 72 dB |
| Resolution | 1 nT |
| Sensitivity | 10 nT |
| Absolute Error @ 50 Hz / 200 nT / 25 °C | ±0.4 dB |
| Frequency Response (40 Hz – 1 kHz) | ±1 dB |
| Isotropy @ 50 Hz / 200 nT | ±0.3 dB |
| Electric Field Rejection | > 20 dB |
| Temperature Coefficient | 0.015 dB/°C |
| Calibration | Built-in EEPROM |
| Dimensions | 350 mm (L) × 133 mm (Ø) |
| Weight | 400 g |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | HP-33M |
| Frequency Range | 700 MHz – 3 GHz |
| Electric Field Range | 0.3 – 300 V/m |
| Overload Protection | > 600 V/m |
| Dynamic Range | > 60 dB |
| Resolution | 0.01 V/m |
| Sensitivity | 0.3 V/m |
| Absolute Accuracy @ 930 MHz (20 V/m) | ±1 dB |
| Frequency Response (900 MHz – 3 GHz) | ±1.5 dB |
| Isotropy @ 930 MHz | ±1 dB |
| H-Field Rejection | > 20 dB |
| Temperature Coefficient | 0.05 dB/°C |
| Calibration | Built-in EEPROM |
| Dimensions | 317 mm × Ø58 mm |
| Weight | 100 g |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 |
| Pricing | Available Upon Request |
| Frequency Range | 20 kHz – 10 MHz |
| Equivalent Protection Circuit | Integrated Transient Current Limiter per IEC 62493 |
| Output Impedance | 50 Ω |
| RF Input Interface (Sphere) | BNC Female |
| RF Output Interface | BNC Female |
| Sphere Diameter | 210 mm |
| Neck Simulator Wire Length | 300 mm |
| Tripod Mount Thread | 1/4″–20 UNC |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −20 °C to +70 °C |
| Weight (Excl. Tripod) | 1.7 kg |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 Test Head |
| Quotation | Upon Request |
| Frequency Range | 20 kHz – 10 MHz |
| Equivalent Protection Circuit | Integrated Transient Current Protection |
| Compliance | Fully IEC 62493 Conformant |
| Output Impedance | 50 Ω |
| RF Input Interface (Sphere) | BNC Female |
| RF Output Interface | BNC Female |
| Sphere Diameter | 210 mm |
| Neck Simulator Length | 300 mm |
| Tripod Mount | 1/4″–20 UNC Thread |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −20 °C to +70 °C |
| Weight (excl. tripod) | 1.7 kg |
| Brand | Polytec |
|---|---|
| Origin | Germany |
| Model | MSA-100-3D |
| Measurement Principle | Heterodyne Laser Doppler Interferometry |
| Max. Bandwidth | 25 MHz |
| Out-of-plane & In-plane Resolution | Sub-picometer (≤ 0.5 pm/√Hz) |
| Laser Spot Size | < 4 µm (at focal plane) |
| Working Distance | Up to 38 mm |
| Scan Area | Programmable XY stage with software-controlled positioning |
| Compliance | ISO 18436-2, ASTM E1876 (for material dynamic characterization), GLP-ready data traceability |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 899 |
| Price | Upon Request |
| Velocity Range | 0.078–200 mm/s (or 0.003–7.87 in/s) |
| Acceleration Range | 0.1–200 m/s² (or 0.33–656 ft/s²) |
| Displacement Range | 0.001–1.999 mm (or 0.00004–0.078 in) |
| Frequency Range | 10 Hz – 1 kHz |
| Basic Accuracy | ±5% of reading + 2 digits |
| Sensor Cable Length | 1 m (39 in) |
| Data Storage Capacity | Up to 500 readings (auto/manual) |
| Measurement Modes | True RMS or Peak |
| Functions | Max/Min Hold, Auto Power-Off, Data Hold |
| Included Accessories | Magnetic Mount, Carrying Case, Base Stand, Protective Housing, 9V Battery |
| Warranty | 3 Years |
| Calibration | NIST-Traceable Certificate Available (Optional) |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR 0084 |
| Field of View | ±2° |
| Calibration | PTB-traceable |
| Flicker Measurement | Compliant with VESA standards |
| Interfaces | USB 2.0, RS232, RS232-TTL |
| Power Supply | 4.7–5.25 V DC via interface |
| Factory Presets | 8 |
| User-defined Presets | 30 |
| Max. Measurement Rate | 10 Hz (low sensitivity), 4 Hz (high sensitivity) |
| Temperature Compensation Range | 20–40 °C |
| Dimensions (L×W×H) | 61 × 26 × 17 mm (excl. mounting interface) |
| Weight | ~80 g |
| Luminance Range | 0.05–2500 cd/m² |
| Chromaticity Accuracy (relative to Illuminant D65) | ±0.002 |
| CCT Accuracy (4000–15000 K) | ±250 K |
| Chromaticity Accuracy (other spectra) | ±0.0065 |
| Luminance Accuracy | ±2% + 1 digit (1–500 cd/m²) |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR126-C |
| Light Source | White LED (5600 K) |
| Spectral Range | 400–700 nm |
| Output Interface | Serial and Parallel (simultaneous) |
| Power Supply | 24 V DC |
| Housing | Anodized Aluminum |
| Color Space | CIELAB (L*, a*, b*) |
| Chromatic Resolution | < 0.1 ΔE |
| Repeatability | < 0.5 ΔE |
| Inter-instrument Agreement | < 1% ΔE |
| Operating Temperature Range | 18–55 °C |
| Temperature Compensation | Automatic |
| Measurement Frequency | 500 Hz |
| Gain Calibration | Auto and User-Adjustable |
| Onboard Storage | Up to 7 product definitions (PR126-C7) or 4 (PR126-C4) with background operation |
| Software | Multilingual configuration and ΔE calculation suite |
| Compliance | Designed for industrial QA/QC in regulated environments (supports GLP/GMP-aligned documentation workflows) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | METLOG S |
| Pricing | Upon Request |
| CPU | 32-bit, 300 MHz |
| Analog Inputs | 1 differential channel with digital isolation |
| ADC Resolution | 12-bit (software-expandable to 24-bit) |
| Accuracy | ±(0.2% of reading + offset) at 0–40°C |
| Pulse Inputs | 2 channels (1 high-speed @ 250 kHz, 1 low-speed), both digitally isolated |
| Digital I/O | 8 configurable digital inputs/outputs supporting status detection, PWM, external interrupt, edge timing, contact closure counting, and high-frequency pulse counting |
| Communication Protocols | SDI-12, Modbus RTU/ASCII/TCP, TCP/IP, UDP, HTTP, I²C, SPI, PPP |
| Interfaces | Ethernet (RJ45), Micro-USB, CS I/O, RS-232, RS-485, UART |
| Onboard Wireless | Integrated 4G/5G LTE module (backward-compatible) |
| Memory | 64 MB SRAM + microSD slot supporting up to 32 GB removable flash storage |
| Real-Time Clock | ±3 min/year (optional GPS synchronization to ±10 µs) |
| Power Supply | 10–15 VDC input (±5 V max input limit) |
| Typical Idle Current | <1 mA @ 12 VDC |
| Active Current | 105 mA @ 12 VDC |
| Operating Temperature | –40°C to +70°C (standard), –55°C to +85°C (extended, non-condensing) |
| Dimensions | 20.5 × 11.2 × 3.5 cm |
| Weight | 0.6 kg |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PS LDV FP50 Shift |
| Pricing | Available Upon Request |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DO |
| Pricing | Upon Request |
| Lenslet Pitch | 150 µm |
| Lenslet Focal Length | 5.2 mm (customizable) |
| Dynamic Range | ≥30 µm |
| Sensitivity | λ/100 @ 633 nm |
| Measurement Accuracy | <10 nm RMS |
| Repeatability | λ/200 @ 633 nm |
| Sensor Active Area | 11.3 mm × 7.12 mm |
| Pixel Resolution | 1920 × 1200 |
| Spectral Response | 400–1000 nm |
| Frame Rate | up to 700 fps |
| Physical Dimensions | 42.6 mm × 29 mm × 29 mm |
| Supported Camera Interfaces | 20+ industrial camera types |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EUV/UV |
| Pricing | Upon Request |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NIR/EUV |
| Pricing | Upon Request |
| Spectral Range | 1100 nm – 1 nm |
| Dynamic Range | up to 100λ |
| Sensitivity | <100 pm |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Camera Compatibility | >20 industrial and scientific camera models supported |
| Micro-lens Array Options | Multiple pitch/focal-length configurations available |
| Software | ISO-compliant beam analysis suite with Zernike decomposition, M² real-time calculation, and Fresnel–Kirchhoff propagation engine |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Model | UV |
| Spectral Range | ~1–1100 nm (EUV, UV, VIS, NIR) |
| Sensor Types | >20 interchangeable CCD/CMOS cameras (small/large area, high resolution, high dynamic range) |
| Interface | USB 3.0 or GigE |
| Bit Depth | 12-bit / 14-bit |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Software | Full remote control & automation support (adaptive optics, motorized attenuators, shutters, power meters) |