| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | CTR 100 |
| Measurement Principle | Ceramic Diaphragm Capacitance |
| Range | 1000 to 0.1 Torr |
| Vacuum Port | KF 16 |
| Output | 0–10 V analog + RS232 digital interface |
| Accuracy | ±0.12% of full scale |
| Sensor Material | Al₂O₃ ceramic diaphragm with 316 stainless steel flange |
| Temperature Compensation | Integrated |
| Overpressure Tolerance | ≥2× full scale |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | DISPLAY |
| Channel Options | 1-Channel or 3-Channel |
| Pressure Range | 10⁻⁹ mbar to 2000 mbar |
| Compatible Sensor Families | THERMOVAC TTR, DU, PENNINGVAC PTR |
| Compliance | CE, RoHS, EN 61000-6-2/-6-4 |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | GRAPHIX |
| Channel Options | 1-channel, 2-channel, 3-channel |
| Pressure Range | 1×10⁻¹⁰ mbar to 2000 mbar |
| Sensor Compatibility | THERMOVAC TTR, CERAVAC CTR, DU, PENNINGVAC PTR, IONIVAC ITR series active sensors |
| Operating Principle | Digital signal processing of analog or digital outputs from active vacuum sensors |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | IE 514 |
| Measurement Principle | Cold Cathode Ionization |
| Pressure Range | 1 × 10⁻¹² to 1 × 10⁻⁴ mbar |
| Vacuum Flange | CF 40 |
| Compliance | ISO 3567, DIN 28403-1, EN 61000-6-3 |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PTR 90 |
| Measurement Principle | Pirani + Cold Cathode (Penning) |
| Range | 1×10³ to 1×10⁻⁸ mbar |
| Vacuum Port | KF 25, CF 40 |
| Output Interface | RS232 / RS485 (digital), optional analog 0–10 V or 4–20 mA |
| Accuracy | ±30% (1×10⁻⁸–1×10⁻² mbar), ±15% (1×10⁻²–10 mbar) |
| LED Indication | Adaptive pulse-mode pressure display |
| Housing | Compact stainless steel, IP65-rated |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TM 201 |
| Measurement Principle | Piezoresistive + Pirani |
| Range | 1200 to 5.0 × 10⁻⁵ mbar |
| Pressure Interface | KF 16 |
| Relative Pressure Capability | –1060 to +1200 mbar |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing environment |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TTR 101 |
| Measurement Principle | Combined Pirani + Capacitive Diaphragm |
| Range | 5×10⁻⁵ – 1500 mbar |
| Vacuum Port | KF 16 |
| Compliance | CE, RoHS, ISO 9001-manufactured design |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TTR 91 RN |
| Measurement Principle | Pirani (thermocouple-based thermal conductivity) |
| Range | 1 × 10³ to 5 × 10⁻⁴ mbar |
| Vacuum Port | KF 16 (DN 16) |
| Accuracy | ±50% (100–10 mbar), ±15% (10–1×10⁻³ mbar), ±50% (1×10⁻³–5×10⁻⁴ mbar) |
| Repeatability | ±2% (100–1×10⁻³ mbar) |
| Power Supply | 15–48 V DC |
| Analog Output | 0–10 V |
| Digital Interface | RS232 or RS485 |
| Electrical Connector | RJ45 or 9-pin D-sub |
| Integrated Particle Filter | Yes |
| Filament Options | Tungsten (standard), Platinum (harsh environments) |
| Operating Temperature | 5–60 °C |
| Max Bakeout Temp (electronics removed) | 150 °C |
| IP Rating | IP40 |
| Certifications | CE, UKCA |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-550 |
| Dimensions | 9.1 cm × 9.1 cm × 5.2 cm |
| Measurement Path Length | 35 mm |
| Weight | ≤50 g |
| Power Supply | 5–32 VDC @ 320 mW |
| Output Interfaces | RS-232 (LI-550), RS-232/RS-422/UART-3V (LI-550P) |
| Sampling Frequencies | 1, 2, 5, 10, 20, 40 Hz |
| Ultrasonic Frequency | 60 kHz |
| Wind Speed Range | 0–50 m/s |
| Wind Speed Resolution | 0.01 m/s |
| Wind Speed Accuracy | ±0.2 m/s (0–10 m/s), ±2% (11–30 m/s), ±4% (31–50 m/s) |
| Wind Direction (u/v) | 0–359°, Resolution: 1°, Accuracy: ±1° |
| Vertical Wind Component (w) Range | ±15° |
| Temperature Range | −20 to +72 °C, Resolution: 0.01 °C, Accuracy: ±2.0 °C |
| Relative Humidity Range | 0–100 %RH, Resolution: 0.1 %RH, Accuracy: ±3 %RH |
| Barometric Pressure Range | 50–115 kPa, Resolution: 0.1 kPa, Accuracy: ±1.0 kPa |
| 3D Accelerometer Range | ±2 g (u/v/w), Tilt (Pitch/Roll): ±90° |
| Magnetometer Range | ±50 Gauss (u/v/w), Heading Accuracy: ±5° |
| Dew Point & Air Density | Computed from measured T, RH, and P |
| Brand | TechnoTeam |
|---|---|
| Origin | Germany |
| Model | LMK Cono |
| Measurement Principle | Conoscopic Imaging Photometry |
| Compliance | TCO 03, ISO 13406-2, IEC 61747-6, VESA DisplayHDR™ (metadata-aware evaluation) |
| Output Format | Radiance (cd/m²), Luminance Ratio, Contrast Ratio (CR), CIE 1931 xy & u'v' Chromaticity vs. Polar Angle (θ) and Azimuthal Angle (φ) |
| Spatial Resolution | Full hemispherical field-of-view (0°–90° θ, 0°–360° φ) captured in single exposure |
| Detector | Scientific-grade monochrome CMOS sensor with linear response and calibrated photopic weighting |
| Lens Type | Conoscopic objective with birefringent crystal stack and polarization-preserving optical path |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HDR-AC3 |
| Price | USD 1,400 (FOB Qingdao) |
| Resolution | 3840 × 2160 (4K UHD) |
| Sensor | Sony 13 MP High-Sensitivity CMOS |
| Zoom | 30× Intelligent Digital Zoom |
| IR Illumination | Built-in IR LEDs with Auto/Manual Night Mode Switching |
| Display | 3.1″ IPS Touchscreen (180° Rotatable) |
| Battery | 1700 mAh Rechargeable Li-ion (Typical Runtime: 2.5–3.5 h Continuous Recording) |
| Wireless Connectivity | IEEE 802.11 b/g/n Wi-Fi (2.4 GHz), Compatible with iOS/Android Remote Control & Live Streaming |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | LT-880 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLAS-2D |
| Price | USD 48,500 (FOB) |
| Brand | m&h |
|---|---|
| Origin | Imported (Non-Chinese) |
| Model | HDR40.00-RX/TX |
| Bidirectional Repeatability (2σ) | 1 µm |
| Recommended Trigger Speed | 254–2000 mm/min |
| Trigger Direction | ±X, ±Y, −Z |
| Maximum Overtravel | XY ±12.5°, Z −6 mm |
| Trigger Force (with 50 mm stylus) | XY = 0.4–1.8 N (adjustable), Z = 4–12 N (adjustable) |
| Power Supply | One 9 V battery or PX28 (6 V) / five LR44 (1.5 V each) |
| IP Rating | IP68 per EN 60529 |
| Weight (excl. toolholder) | 1350 g |
| Operating Temperature Range | 10–50 °C |
| Housing Material | Stainless steel |
| Signal Transmission Rate | 9600 pulses/sec |
| Angular Coverage | 130° (radial), 360° (axial) |
| Transmission Range | 4–10 m (adjustable) |
| Probe Diameter | Φ25–63 mm |
| Probe Length | 110–410 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | TransiTempII, TransiTempII-RH, Cryo-Temp |
| Price | USD 1,450 (FOB) |
| Temperature Range (TransiTempII) | –40 °C to +80 °C |
| Temp. Accuracy | ±0.5 °C |
| Humidity Range (TransiTempII-RH) | 0–95 %RH |
| RH Accuracy | ±5 %RH |
| Temperature Range (Cryo-Temp) | –86 °C to +35 °C |
| Temp. Accuracy (Cryo-Temp) | ±1.0 °C |
| Memory Capacity | 32,767 readings (TransiTempII & Cryo-Temp), 16,383 readings (TransiTempII-RH) |
| Battery Life | Up to 1 year (typical continuous logging at 1-min interval) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TransiTempII |
| Price | USD 1,420 (converted from ¥1000 at ~7.05 CNY/USD) |
| Operating Range | –40 °C to +80 °C |
| Accuracy | ±0.5 °C |
| Memory Capacity | 32,767 readings |
| Battery Life | Up to 1 year (typical use at 25 °C, 1-min logging interval) |
| Dimensions | 63.5 × 31.8 × 25.4 mm |
| Weight | 34 g |
| Enclosure | IP67-rated polycarbonate housing |
| Logging Interval | Configurable from 1 second to 18 hours |
| Start Mode | Immediate, Delayed, or Triggered (via external contact closure or temperature threshold) |
| Data Retrieval | USB-A direct connection (no driver required on Windows/macOS/Linux) |
| Compliance | RoHS, CE, FCC Part 15 Class B |
| Brand | MagQu |
|---|---|
| Origin | Taiwan |
| Model | XacQuan |
| Frequency Range | 10 Hz – 25 kHz |
| Output | Real (χ′) and Imaginary (χ″) Components of AC Susceptibility |
| Sample Volume | ≥ 0.1 mL |
| Measurement Time | < 60 s per sample |
| Compliance | CE-marked, RoHS-compliant |
| Software Interface | Windows-based GUI with real-time plotting and data export (CSV, TXT) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME-288B |
| Pricing | Upon Request |
| Brand | MEAS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | D-Series |
| Pricing | Upon Request |
| IP Rating | IP67 |
| Output Options | Analog (0–5 V / 4–20 mA), Digital (RS232/RS485), Switch Output |
| Measurement Ranges | ±5°, ±15°, ±30° |
| Resolution | 0.001° |
| Accuracy (Digital/Analog, typical at 25°C) | ±0.04° |
| Accuracy (Digital/Analog, full temp range −40°C to +85°C) | ±0.15° (±0.3° for ±15° range, ±0.8° for ±30° range) |
| Temperature Drift | 0.06% FS/°C |
| Bandwidth | 23 Hz |
| Noise Density | 0.001° RMS |
| Supply Voltage | 10–30 VDC |
| Supply Current | 30–40 mA |
| Operating Temperature | −40°C to +85°C |
| Storage Temperature | −40°C to +85°C |
| Dimensions (W × D × H) | 84 × 70 × 46 mm |
| Weight | 290 g |
| EMC Compliance | EN 61000-6-2 / EN 61000-6-4 |
| Shock & Vibration | MIL-STD-810G compliant |
| Certifications | CE, RoHS |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ATMOS 14 |
| Measurement Parameters | Water Vapor Pressure, Air Temperature, Relative Humidity, Atmospheric Pressure |
| Communication Protocols | SDI-12, DDI Serial Interface |
| Operating Temperature Range | -40 °C to +80 °C |
| RH Range | 0–100 % RH (Resolution: 0.1 % RH |
| Accuracy | ±0.8 % RH typical hysteresis |
| Long-term drift | ±0.25 % RH/year) |
| Temperature Accuracy | ±0.2 °C |
| Drift | <0.03 °C/year |
| Vapor Pressure Range | 0–47 kPa (Resolution: 0.01 kPa) |
| Barometric Pressure Range | 1–120 kPa (Accuracy: ±0.05 kPa @ 25 °C |
| Drift | <0.1 kPa/year) |
| Response Time (τ₆₃) | <25 s (RH), <165 s (T), <10 ms (P) |
| Physical Dimensions | Ø20 mm × 54 mm |
| Cable | Standard 5 m (up to 75 m customizable) |
| Power Supply | 4.0–15.0 VDC |
| Current Draw | 3.5 mA typical during measurement, 0.03 mA in standby |
| Compliance | ISO 9001:2015, EN 61326-1:2013, EN 50581:2012, 2004/108/EC, 2011/65/EU |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ECRN-50 / ECRN-100 |
| Sensor Type | Tipping Bucket (Single for ECRN-50 |
| Resolution | 1.0 mm per tip (ECRN-50) / 0.2 mm per tip (ECRN-100) |
| Output | Pulse (Open Collector) |
| Housing Material | UV-stabilized, waterproof, frost-resistant ABS plastic |
| Operating Temperature | 0–60 °C |
| Cable Length | 5 m |
| Connector Type | 3.5 mm mono audio jack |
| Compatible Data Loggers | METER ZL6, EM50/EM60 series, ProCheck |
| Compliance | Designed for long-term field deployment in accordance with ASTM D3478 and ISO 9060:2018 Class B recommendations for precipitation measurement |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. (formerly Decagon Devices) |
| Model | ECRN-100 |
| Resolution | 0.2 mm |
| Sensor Type | Dual tipping bucket |
| Housing Material | UV-stabilized, waterproof, frost-resistant ABS plastic |
| Operating Temperature | 0–60 °C |
| Cable Length | 5 m |
| Interface | 3.5 mm stereo audio jack (pulse output) |
| Dimensions | 17 cm × 14.2 cm |
| Data Logger Compatibility | METER ZL6, EM50/EM60, ProCheck (sold separately) |
| Certification Compliance | Designed for long-term field deployment in accordance with WMO Guide to Instruments and Methods of Observation (CIMO Guide), ISO 9060:2018 Class B recommendations for precipitation measurement |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECRN-50 |
| Pricing | Available Upon Request |
| Sensor Type | Single-Tip Tipping Bucket |
| Resolution | 1 mm |
| Output Units | gal/h or L/h (configurable) |
| Housing Material | UV-Stabilized, Waterproof, Frost-Resistant ABS Plastic |
| Operating Temperature | 0–60 °C |
| Cable Length | 5 m |
| Interface | 3.5 mm Stereo Jack (TTL Pulse Output) |
| Dimensions | 5 cm × 10 cm (Diameter × Height) |
| Data Logger Compatibility | METER ZL6, EM50/EM60 Series, ProCheck (sold separately) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Pressure-Based Water Level Sensor |
| Model | HYDROS 21 |
| Measurement Principle | Absolute pressure transduction with barometric compensation |
| Depth Range | 0–1000 cm H₂O |
| EC Range | 0–120 dS/m |
| Temperature Range | −40 to +60 °C |
| Resolution | 1 mm (depth), 0.001 dS/m (EC), 0.1 °C (temp) |
| Accuracy | ±0.25% FS @20 °C (depth), ±0.01 dS/m or ±10% (EC), ±1 °C (temp) |
| Output Interface | DDI serial or SDI-12 |
| Power Supply | 4.0–15.0 VDC |
| Operating Temperature | 0–60 °C |
| Dimensions | Ø3.4 cm × 9 cm |
| Cable | Standard 10.0 m (optional 20.0/40.0 m), Ø6.00 ± 0.25 mm with 0.80 mm jacket |
| Connector | 3.5 mm stereo jack or tinned 3-wire lead |
| Current Draw | 2.5–8.0 mA (active), ~0.35 mA (standby) |
| Startup Time | 52–100 ms (DDI), ≤750 ms (SDI-12), ≤200 ms (SDI-12 w/ DDI disabled) |
| Measurement Duration | ≤600 ms |
| Compliance | ISO 9001:2015 certified manufacturing |
| CE marked per EM ISO/IEC 17050 | 2010 |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | SO-431 |
| Measurement Principle | Galvanic (Electrochemical) |
| Output Signal | Analog mV (O₂ concentration proportional) |
| Range | 0–30% O₂ |
| Repeatability | < 0.1% (at 20.95% O₂) |
| Nonlinearity | < 1% |
| Long-term Drift | 5% per year (0.6 mV/year) |
| O₂ Consumption | 0.1 μmol/day (at 20.95% O₂, 23°C) |
| Response Time (t₉₀) | 15 s |
| Operating Temperature | –20 to +60 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Pressure Range | 60–114 kPa |
| Excitation Voltage (Thermistor) | 2.5 V DC |
| Heater Supply | 12 V DC |
| Heater Power | 74 mW |
| Thermistor Current | ≤0.1 mA @ 70 °C |
| Quiescent Current | 0.6 mA |
| Active Measurement Current | 1.3 mA |
| Sensitivity | 10–15 mV at 20.95% O₂ (sea level, 101.3 kPa) |
| Zero Output | < 0.5 mV |
| Housing Material | Polypropylene |
| Diffusion Cavity | Integrated micro-chamber for gas equilibration |
| Cable Length | 5 m (extendable) |
| Dimensions | Ø32 mm × 68 mm |
| Weight | 175 g (incl. cable) |
| Compatible Data Loggers | METER EM60 Series, ZL6 Series, ZSC |
| Software Integration | ZENTRA Cloud platform with auto-recognition and remote data access |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T5 |
| Product Category | Pressure-Based Tensiometer |
| Measurement Principle | Ceramic Cup Equilibrium with Integrated Piezoresistive Pressure Transducer |
| Operating Range | +100 to −85 kPa (≈ pF 2.9) |
| Accuracy | ±0.5 kPa |
| Resolution | 0.1 kPa |
| Typical Drift | <0.5% per annum |
| Temperature Compensation | Yes, 0.5% FS over 25 K |
| Excitation Voltage | 10.6 VDC (5–15 VDC stable) |
| Output Signal | Ratiometric mV/V (−100 ±3 mV at +100 kPa |
| Sensor Body Diameter | 5 mm |
| Sensor Head Diameter | 20 mm |
| Sensing Area | 0.5 cm² |
| Total Length | 4 cm + custom shaft length (standard 70 mm) |
| Cable Length | Standard 5 m (customizable) |
| Power Consumption | ~1.3 mA @ 10.6 VDC |
| Bridge Configuration | Asymmetric Wheatstone Bridge |
| Sensing Element | Silicon Piezoresistive Pressure Sensor |
| Max Overpressure Tolerance | ±300 kPa |
| Material | Acrylic Shaft, Porous Ceramic Cup |
| Compatibility | Campbell Scientific dataloggers, InField 7 systems |
| Brand | METER |
|---|---|
| Origin | USA (Designed & Engineered in Germany) |
| Manufacturer | METER Group GmbH & Co. KG (formerly UMS) |
| Model | TEROS 32 |
| Type | Pressure-Based Tensiometer |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), ISO/IEC 17050:2010 |
| Measurement Range | -85 to +50 kPa (soil water potential), -30 to +60 °C (temperature) |
| Resolution | 0.0012 kPa, ±0.01 °C |
| Accuracy | ±0.15 kPa, ±0.1 °C (-20–40 °C), ±1 °C (outside range) |
| Output Protocols | SDI-12, DDI serial, TensioLINK™, Modbus RTU |
| Power Supply | 4.0–28.0 VDC |
| Enclosure Rating | IP68 |
| Ceramic Cup Material | Al₂O₃ (AI203), Bubble Point: 1500 kPa |
| Rod Material | PMMA |
| Corpus Material | POM-GF (glass-fiber-reinforced polyoxymethylene) |
| Probe Length Options | 40 cm / 80 cm / 120 cm |
| Diameter | 2.5 cm |
| Cable Options | Standard 5 m, up to 75 m custom |
| Connector Types | 3.5 mm stereo jack (4-pin), M12 (4-pin), or tinned bare wire |
| Installation Angle | -80° to -10° (upward), +10° to +80° (downward) |
| Operating Temperature | -30 °C (dry), 0 °C (hydrated), max 50 °C |
| Ceramic Cup Warranty | 10 years |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | ZL6 |
| Pricing | Contact for Quote |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML 2100 VariLux |
| Dimensions (ML2100/ML2150) | ~40×40×60 mm³ |
| Max. Avg. Power | 5 W |
| Available Wavelengths | 157–1064 nm |
| Max. Transmission | >70% (157 nm) to >90% (248–1064 nm) |
| Min. Transmission | <2% (157 nm) to <1% (≥248 nm) |
| Damage Threshold (1 Hz) | 0.2–15.0 J/cm² (wavelength-dependent) |
| Mounting | C-mount |
| Spectral Range (ML2300 PolarLux) | 185–2000 nm |
| Max. Input Power (ML2300) | <1000 W |
| Max. Avg. Power Density (ML2300) | <10,000 W/cm² |
| Max. Pulse Power Density (ML2300) | 2 GW/cm² |
| Beam Deviation | 90° (non-polarizing), 0° (polarizing) |
| Free Aperture (ML2300) | ~15×15 mm² |
| Wedge Material | Fused Silica |
| Neutral Density Filters | OD 0.9–4.0, absorbing & metallic types, 200–700 nm range |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML 6020 |
| Wavelength Range | 400–1800 nm |
| Absolute Accuracy | typ. 5 × 10⁻⁷ |
| Relative Accuracy | 1 × 10⁻⁶ – 1 × 10⁻⁷ |
| Laser Linewidth | < 8 GHz |
| Measurement Rate | 8.3 Hz |
| Minimum Input Power | 100 µW |
| Maximum Input Power | 1.5 mW |
| Integrated He–Ne Reference Wavelength | 632.8 nm |
| Interface | IEC 625 (IEEE-488) GPIB |