| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AH-22-T |
| Pricing | Upon Request |
| Sample Chamber Volume | 0.1 mL |
| Throughput | 3 samples per run |
| Focusing Method | Auto-focus / Manual focus |
| Identifiable Taxa | ≥80 common algal genera and species |
| Imaging Sensor | 5 MP CMOS camera |
| Species Recognition Accuracy | ≥90% |
| Pixel Resolution | < 0.3 µm/pixel |
| Full-field Scan Mosaic Imaging | Supported |
| Compliance | HJ 1295–2023, HJ 1296–2023, HJ 1216–2021, HJ 1215–2021, SL 733–2016, and related freshwater periphyton & phytoplankton monitoring technical specifications |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Auto-Identification System for Giardia Cysts and Cryptosporidium Oocysts |
| Pricing | Available Upon Request |
| Stage Travel | 100 × 50 mm |
| XY Positioning Resolution | 0.1 µm |
| XY Repeatability | < ±5 µm |
| Max XY Speed | 20 mm/s |
| Z-Axis Travel | 20 mm |
| Z Resolution | 0.1 µm |
| Z Repeatability | < ±1 µm |
| Camera Interface | USB 3.0 |
| Imaging Sensor | High-Sensitivity Monochrome CMOS |
| Recognition Accuracy | >90% (per ASTM D6534-22 validation protocol) |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Category | Domestic (China-Made) |
| Model | CDR-01 Enzyme-Substrate Reagent |
| Pricing | Available Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-ESAC100 |
| Pricing | Upon Request |
| Illumination Source | Shadow-Free White LED Light Source |
| Detection Method | High-Resolution Digital Camera + AI-Powered Image Recognition Algorithm |
| Interface | USB-A |
| Special Function | Auto-Dilution Mode Support |
| Identification Speed | <10 seconds per quantitative tray |
| Operating Ambient Temperature | 0–45 °C |
| Dimensions (W×D×H) | 380 × 243 × 364 mm |
| Weight | 12 kg |
| Power Supply | AC 220 V ±10% |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HTY-GCC-F100 |
| Power Supply | AC 220 V / 50 Hz |
| Maximum Sample Volume | 0–9999 L |
| Filtration Material | 316L Stainless Steel + Titanium Alloy Filter Discs |
| Touchscreen Interface | 7-inch Foldable Color LCD |
| Concentration Flow Rate | 0–2.2 L/min (adjustable) |
| Filter Cartridge Actuation | One-Touch Electric Control |
| Rated Power | ≤200 W |
| Net Weight | 15 kg |
| Pressure Sensor Range | 0–2.0 MPa |
| Sterilization Methods | Chemical Disinfectant Rinse / Moist Heat Sterilization |
| Membrane Replacement Alert | Automatic Notification |
| Channel Scalability | Up to 8 Units in Parallel Configuration |
| Average Recovery Efficiency | >35% (Cryptosporidium oocysts & Giardia cysts, per EPA Method 1623.1/ISO 15553) |
| Workflow Customization | User-Defined SOP Sequencing, Adjustable Sample Volume Input, Real-Time Status Alerts & Emergency Stop Functionality |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-GCC-S100 |
| Price | Upon Request |
| Water Processing Capacity | 10 L per cycle |
| Pretreatment Time | ≤15 min |
| Touchscreen Interface | 7-inch foldable color LCD |
| Sample Loading | Motorized or manual |
| Power Consumption | ≤300 W |
| Unit Weight | 18 kg |
| Settling Timer Range | 0–99 h |
| Turbidity Sensor Range | 0–200 NTU |
| Pressure Sensor Range | 0–2.0 MPa |
| Stirring Speed Range | 0–1500 rpm |
| Disinfection Method | Integrated UV-C lamp (254 nm) |
| pH Sensor Range | 0–14 |
| Parallel Operation | Up to 8 units via master-slave configuration |
| Average Protozoan Recovery Efficiency | >35% (per ASTM D5421 / ISO 15553 validated methodology) |
| Workflow Customization | User-defined SOPs with real-time status alerts and auto-halt on anomaly detection |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTY-UVB01 |
| UV Wavelengths | 254 nm (short-wave) & 366 nm (long-wave) |
| Lamp Voltage | 50 V ± 10 V |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤75% RH |
| Dimensions (L×W×H) | 320 × 240 × 320 mm |
| Weight | 3.8 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Design Features | Integrated UV housing with magnetic sample door, dual-side access ports, UV-shielded operation |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | QYP Series Sterile Sampling Bottles |
| Pricing | Available Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SWS Series Sterile Water Sampling Bags |
| Pricing | Available Upon Request |
| Volume Options | 100 mL, 250 mL, 500 mL |
| Sterilization Method | Gamma Irradiation |
| Packaging | Individual Sterile Peel-Pouch |
| Membrane Structure | Triple-Layer Laminated Film (PET/AL/PE) |
| Closure | Integrated Single-Use Snap Lock Cap |
| Sodium Thiosulfate Option | Available (1.8 mg/bag, pre-loaded for chlorine neutralization) |
| Compliance | Meets ISO 19458:2006 (Water quality — Requirements for sterile sampling containers), USP <61> Microbial Enumeration Tests, and EPA Method 1603 (E. coli in water) |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Enzyme-Substrate-Based Total Colony Count Detection Kit |
| Pricing | Available Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HTY-APM100 |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HTY-ESIC97 |
| Pricing | Upon Request |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (W × D × H) | 1320 × 835 × 1890 mm |
| Weight | ≤ 100 kg |
| Total Power Consumption | 5 kW |
| Operating Noise Level | ≤ 60 dB(A) |
| Target Microorganisms | Total Coliforms, Escherichia coli |
| Incubation Temperatures | 37 °C and 44.5 °C |
| Temperature Control Accuracy | ±0.4 °C |
| Quantification Plate Formats | 97-well and 51-well |
| Maximum Concurrent Plates | 100 |
| Integrated UV Observation Chamber | Yes |
| Data Integrity Features | Audit Trail, Electronic Signature, Role-Based Access Control (3-Tier), Automatic Archiving, LIMS Compatibility, Customizable Report Templates, Cloud/Network Reporting |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HTY-QTS01 |
| Pricing | Upon Request |
| Operating Voltage | 220 V ±10% |
| Preheat Time | <15 min |
| Ambient Operating Temperature | −10 °C to 50 °C |
| External Housing Temperature | <40 °C |
| Dimensions (W×D×H) | 390 × 300 × 270 mm |
| Weight | 19 kg |
| Noise Level | <50 dB(A) |
| Compatible With | 51-well and 97-well Quanti-Tray®-style trays |
| Includes | MPN lookup tables (51- and 97-well), silicone sealing gasket |
| Maintenance | Front-access service door for routine cleaning and component inspection |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HTY-QTS02 |
| Pricing | Upon Request |
| Weight | 15 kg |
| Power Consumption | 1 kW |
| Input Voltage | AC 220 V / 50 Hz |
| Sealing Cycle Time | < 10 s |
| Warm-up Time | < 2 min |
| Heating Temperature Range | 150–200 °C (adjustable) |
| Dimensions (W × D × H) | 380 × 350 × 245 mm |
| Display | 5-inch TFT LCD touchscreen |
| UV Sterilization | Integrated germicidal UV-C lamp (254 nm) |
| Sealing Mechanism | Pneumatically assisted upward-pressing thermal sealing |
| Maintenance Access | Top-hinged service panel |
| Drainage | Spring-loaded pop-up drip tray |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | HTY-QTS02L |
| Pricing | Upon Request |
| Power Supply | AC 220 V / 50 Hz |
| Sealing Speed | ≤9 s per sample |
| Rated Power | 450 W |
| Preheating Time | ≤4 min |
| Weight | 8.5 kg |
| Ambient Temperature Limit | ≤40 °C |
| Operating Temperature Range | 5–45 °C |
| Operating Relative Humidity | ≤75 % RH |
| Brand | Teledyne RDI (distributed by AVVOR) |
|---|---|
| Origin | USA |
| Model | ChanneIMaster H-ADCP |
| Frequency Options | 300 kHz |
| Velocity Accuracy | ±0.5% of measured value or ±0.2 cm/s (whichever is greater) |
| Velocity Resolution | 1 mm/s |
| Velocity Range | ±5 m/s (default), ±20 m/s (max) |
| Cell Size Range | 0.25–8 m (model-dependent) |
| Maximum Profiling Range | 20–300 m (model-dependent) |
| Beam Configuration | Dual-beam, ±20° tilt, 1.5–2.2° beam divergence |
| Memory | 4 MB internal |
| Integrated Sensors | Ultrasonic water level sensor, pressure transducer, tilt sensor (pitch & roll) |
| Standard Cell Count | 128 user-configurable cells |
| Brand | Teledyne RDI |
|---|---|
| Origin | USA |
| Model | ChannelMaster H-ADCP |
| Frequency Options | 300 kHz, 600 kHz, 1200 kHz |
| Velocity Range | ±10 m/s (configurable) |
| Velocity Resolution | 0.1 mm/s |
| Depth Cell Size | 0.1–2.0 m (user-selectable, up to 128 cells) |
| Water Level Sensors | Ultrasonic (0.1–10 m, ±0.25% FS, 0.01 cm res), Pressure (0.1–10 m, ±0.5% FS, 0.1 cm res) |
| Temperature Sensor | −4 °C to +40 °C (±0.2 °C, 0.01 °C res) |
| Tilt Sensor | Dual-axis (±10°, ±0.2° @ 0°, ±0.5° @ 10°, 0.01° res) |
| Memory | 4 MB internal flash |
| Communication | RS-232, RS-422, SDI-12 v1.3 |
| Power | 10–18 VDC (typical consumption: 0.13–0.16 W |
| standby | 0.25 mW) |
| Housing | Polyurethane-cast body, titanium fasteners, stainless steel mounting frame |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR-V1 |
| Pricing | Upon Request |
| Measurement Principle | Infrared Absorption Photometry |
| Measurable Analytes | TMAH, H₂SO₄, HCl, NaOH, H₂O₂ |
| Concentration Ranges | H₂SO₄: 0–500 g/L |
| HCl | 0–200 g/L |
| NaOH | 0–300 g/L |
| TMAH | 0–250 g/L |
| H₂O₂ | 0–350 g/L |
| Sample Temp. Range | 0.0–35.0 °C |
| Calibration | Zero calibration standard |
| Memory Capacity | Up to 19 measurement records |
| Power Supply | 4× LR03 alkaline batteries |
| Auto-Power-Off | After 10 min inactivity |
| Sample Volume | ~1 mL |
| Dimensions (W×H×D) | 88×174×65 mm |
| Weight | ~310 g |
| Standard Accessories | Instrument body, measurement cell, batteries, instruction manual, warranty card |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AutoTration-500 |
| Price | Upon Request |
| Sample Capacity | 48 × 50 mL beakers or 28 × 150 mL beakers |
| Interface | RS232 |
| Operating Voltage | 90–240 V, 50/60 Hz |
| Positioning Accuracy | ±1.0 mm (all axes) |
| X-axis Travel / Accuracy | 510 mm / <0.1 mm |
| Y-axis Travel / Accuracy | 270 mm / <0.1 mm |
| Z-axis Travel / Accuracy / Zero Offset | 160 mm / <0.1 mm / 140 mm |
| Environmental Operating Range | 5–45 °C, 20–80 % RH |
| Certifications | CE |
| Power Consumption | 100 VA |
| Compatible Instruments | Thermo Fisher Orion Star Series Meters |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | 096019 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Models | 8157BNUMD (Refillable), 8107BNUMD (Low-Maintenance) |
| pH Range | 0–14 |
| pH Accuracy | ±0.03 pH (with ATC) |
| pH Precision | ±0.01 pH |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1.0 °C |
| Reference System | ROSS™ Double-Junction |
| Internal Reference | ROSS™ Liquid Junction |
| Isopotential Point | pH 7 |
| Fill Solution (Refillable) | 3 M KCl |
| Body Material | Epoxy Resin |
| Electrode Length | 120 mm |
| Diameter | 12 mm |
| Compatible Meters | Orion Star™, Aplus™, and PerpHecT® Series |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | TpH |
| Measurement Principle | Potentiometric Analysis |
| Measured Parameters | pH (0–14), Temperature (0–65 °C) |
| Accuracy | ±0.01 pH, ±0.1 °C |
| Resolution | ±0.06 pH, ±0.5 °C |
| Intrinsic Error (pH 1/7/13) | ±0.05 / ±0.05 / ±0.35 pH |
| Linearity Error | ±0.1 pH |
| Repeatability (pH 1/7/13) | ±0.1 / ±0.05 / ±0.1 pH |
| Signal Stability (pH 4/7) | ±0.05 / ±0.025 pH |
| Warm-up Time | < 5 min |
| Short-term Drift (24 h) | < 0.03 pH |
| Long-term Drift (1 week) | < 0.05 pH |
| Response Times (T10/T90/T100) | ≤2 s / ≤5 s / ~10 s |
| Temperature Compensation | Pt1000 |
| Output Interface | RS-485, Modbus RTU |
| Supply Voltage | 12–24 VDC (±10 %) |
| Power Consumption | 0.2 W |
| Housing Material | PPS / PET / NBR |
| Dimensions (L × Ø) | 180 × 27 mm |
| Weight | 110 g |
| Cable Options | 2 m, 10 m (standard) |
| IP Rating | IP68 |
| Max. Operating Pressure (free-flow) | 3 bar |
| Max. Flow Rate | 3 m/s |
| Sample Temp. Range | +2 to +40 °C |
| Ambient Temp. Range | −5 to +55 °C |
| Storage Temp. | 0 to +80 °C |
| Maintenance Interval | ≤0.5 h/month |
| Calibration Interval | 4 weeks |
| Flow Cell Compatibility | Yes (1 bar, 2–4 L/min) |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | EGC-enviroFlu-HC |
| Pricing | Upon Request |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | LISA color |
| Optical Path Lengths | 50 mm, 100 mm, 150 mm, 250 mm |
| Measurement Principles | Absorption-based attenuation at dual-wavelength LED pairs (e.g., 436 nm & 740 nm) |
| Compliance Standards | DIN EN ISO 7887:2012-04 (Methods B & C), DIN EN ISO 6271-2:2005-03, GOST 3351-74 |
| Measured Parameters | SAC (436/525/620 nm), True Color (410 nm), Hazen/APHA (390/455 nm), Cr-Co (380/413 nm) |
| Turbidity Compensation | Yes, via 740 nm reference channel |
| Accuracy | ±0.5 % of reading |
| Response Time | 4 s |
| Minimum Measurement Interval | 2 s |
| Housing Materials | Stainless Steel 1.4571 / 1.4404 or Titanium Grade 2 (3.7035) |
| Dimensions (L × Ø) | 340 mm × 48 mm (for 50 mm path) |
| Weight | ~2.4 kg (stainless), ~1.3 kg (titanium) |
| Digital Interfaces | Ethernet (TCP/IP), RS-232/RS-485 (Modbus RTU) |
| Analog Output | 4–20 mA |
| Power Supply | 12–24 VDC (±10 %), ≤1 W |
| Max. Pressure Rating | 30 bar (SubConn), 3 bar (fixed cable), 1 bar (flow cell) |
| IP Rating | IP68 |
| Operating Temperature | +2 °C to +40 °C |
| Storage Temperature | −20 °C to +80 °C |
| Flow Velocity Range | 0.1–10 m/s |
| Data Memory | ~2 MB |
| Calibration Interval | 24 months |
| Optical Window | Nano-coated sapphire |
| Cleaning Option | Optional pneumatic cleaning system |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | LISA SAC 254 |
| Measurement Principle | UV absorbance at 254 nm (SAC₂₅₄) and visible reference at 530 nm |
| Light Source | Dual LED (254 nm UV-C, 530 nm green) |
| Detector | Filtered photodiode |
| Path Length Options | 1, 2, 5, 10, or 50 mm |
| Output Interfaces | Ethernet (TCP/IP), RS-232/RS-485 (Modbus RTU, TriOS protocol), 4–20 mA analog |
| Turbidity Compensation | Internal dual-wavelength correction (530 nm channel) |
| Accuracy | ±0.2% FS |
| Response Time | 4 s |
| Measurement Interval | 2 s |
| Data Logging Capacity | 2 MB (T100 format) |
| Operating Temperature | 2–40 °C (sample & ambient) |
| Storage Temperature | −20–80 °C |
| Flow Velocity Range | 0.1–10 m/s |
| Max. Pressure (SubConn) | 30 bar |
| Max. Pressure (Fixed Cable) | 3 bar |
| Max. Pressure (Flow Cell) | 1 bar (2–4 L/min) |
| Enclosure Material | Stainless Steel 1.4571 / 1.4404 or Titanium Grade 3.7035 |
| IP Rating | IP68 |
| Power Supply | 12–24 VDC (±10%) |
| Power Consumption | ≤1 W |
| Dimensions (10 mm path) | 300 mm × 48 mm |
| Weight (10 mm, stainless steel) | 1.6 kg |
| Compliant With | ISO 7027 (turbidity correlation), ASTM D5540 (SAC-based organic carbon estimation), EN ISO 8466-1 (calibration linearity), FDA 21 CFR Part 11-ready data logging (via TriOS software) |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | microFlu CDOM |
| Light Source | High-efficiency blue LEDs (370 nm) with internal reference photodiode |
| Detector | Photodiode (460 nm, 20 nm FWHM) |
| Measurement Range | 0–20 μg/L and 0–200 μg/L (dual-range auto-adaptive) |
| Detection Limit | 0.02 μg/L |
| Resolution | 0.02 μg/L |
| Accuracy | ±3% of reading |
| Housing | Marine-grade stainless steel (corrosion-resistant to seawater) |
| Dimensions | Ø48 × 200 mm |
| Weight | 0.5 kg |
| Pressure Rating | 500 m water depth |
| Electrical Interface | RS-232 and 0–5 V analog output |
| Connector | SUB-CONN Micro 5-pin male |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | microFlu-HC |
| Measurement Principle | UV-induced fluorescence (255 nm excitation, 360 nm emission) |
| Target Analytes | Polycyclic Aromatic Hydrocarbons (PAHs) and total petroleum hydrocarbons (TPH) in water |
| Range | PAHs 0–5000 ppb, TPH 0–150 ppm |
| LOD | PAHs 5 ppb, TPH 0.15 ppm |
| Accuracy | ±10 % FS |
| Response Time (T90) | 6 s |
| Min. Measurement Interval | 3 s |
| Digital Interface | RS-485 / Modbus RTU |
| Analog Outputs | 4–20 mA (default), 0–5 V, 0–10 V |
| Power Supply | 12–24 VDC (±10 %) |
| Housing Material | Stainless Steel 1.4571/1.4404 or Titanium Grade 3.7035 |
| Dimensions | 162 mm × 48 mm |
| Weight | ~650 g (SS), ~510 g (Ti) |
| Max. Pressure Rating | 30 bar (SubConn), 3 bar (fixed cable), 1 bar (flow cell) |
| IP Rating | IP68 |
| Operating Temp. | +2 to +40 °C (sample & ambient) |
| Storage Temp. | −20 to +80 °C |
| Flow Rate Compatibility | 0.1–10 m/s |
| Optical Window | Nano-coated quartz |
| Turbidity Compensation | None |
| Data Logging | Internal storage not supported |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | OPUS UV |
| Light Source | Xenon lamp |
| Detector | 256-channel miniature spectrometer (200–360 nm, 0.8 nm/pixel) |
| Measurement Principle | Absorption spectroscopy (attenuation-based) |
| Optical Path Lengths | 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 50 mm |
| Turbidity Compensation | Yes |
| Data Memory | 2 GB internal |
| Measurement Interval | ≥1 minute |
| Output Interfaces | RS232 or RS485 |
| Power Consumption | ≤8 W |
| Housing Material | Stainless steel or titanium alloy (seawater-resistant) |
| Dimensions | Ø48 × 470 mm |
| Weight | 3 kg (stainless steel, 10 mm path) |
| Pressure Rating | 30 bar (with SubConn connector), 3 bar (fixed cable), 1 bar (flow cell, 2–4 L/min) |
| Ingress Protection | IP68 |
| Sample Temperature Range | 2–40 °C |
| Ambient Temperature Range | 2–40 °C |
| Storage Temperature Range | −20–80 °C |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tcon |
| Price | Upon Request |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | TpH-D |
| Measurement Principle | Potentiometric Analysis |
| pH Range | 0–14 pH |
| Temperature Range | 0–65 °C |
| Resolution | 0.01 pH / 0.1 °C |
| Accuracy | ±0.06 pH / ±0.5 °C |
| Repeatability | ±0.05 pH (pH 7), ±0.1 pH (pH 1 & 13) |
| Drift (24 h) | <0.03 pH |
| Response Time T90 | ≤5 s |
| Temperature Compensation | Pt1000 |
| Output Interface | RS-485, Modbus RTU |
| Power Supply | 12–24 VDC (±10%) |
| Power Consumption | 0.2 W |
| Housing Material | PPS / PET / NBR |
| Dimensions (L×D) | 225 × 32 mm |
| Weight | 180 g |
| IP Rating | IP68 |
| Max Operating Pressure | 3 bar (typical), 1 bar (in flow cell) |
| Flow Rate Compatibility | 0–3 m/s |
| Cable Options | 0.5 m, 2 m, 10 m fixed |
| Maintenance Interval | ≤0.5 h/month |
| Calibration Interval | Every 4 weeks |
| Sample Temp. | +2–+40 °C |
| Ambient Temp. | −5–+55 °C |
| Storage Temp. | +5–+15 °C |