PCR/Sequencing/Nucleic Acid Analysis
Filter
Showing 241–270 of 399 results
| Brand | Inheco |
|---|---|
| Origin | Germany |
| Model | CPAC Ultraflat, CPAC Microplate |
| Temperature Range (1-TEC) | 4 °C to 70 °C |
| Temperature Range (2-TEC) | 4 °C to 110 °C |
| Plate Compatibility | 96-well, 384-well microplates |
| Mounting Options | Surface-mounted (Ultraflat), Embedded (Microplate) |
| Height (Ultraflat) | 80 mm |
| Height (Microplate active surface) | ~14 mm above deck |
| System Integration | Compatible with Agilent Bravo/BioCel, Beckman Biomek FX/NX/i-Series, Hamilton STAR/Nimbus/Vantage, PerkinElmer Sciclone/Zephyr/JANUS/Multiprobe II, Protodyne BioCube, Tecan Freedom EVO/Genesis/TEMO/Fluent |
| Control Interface | STC (Single TEC Control), MTC or MTC Compact (Multi-Module Control, up to 6 units) |
| Power Supply | 24 V DC |
| Weight | 10 kg |
| Dimensions (W×D×H) | 300 mm × 600 mm × 900 mm |
| Application | Integrated thermal control for NGS library preparation — amplicon-based workflows, enzymatic reactions, adapter ligation, cleanup incubations, and QC-compatible temperature staging |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | InsituPro Vsi |
| Instrument Type | In Situ Hybridization System |
| Temperature Range | 6–75 °C (Basket Mode), 10–70 °C (Slide Mode) |
| Buffer Volumes | 2×1000 mL, 3×50 mL, 6×125 mL, 7×50 mL |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Qubit Flex |
| Detection Time | ≤3 s |
| Wavelength Accuracy | ≤±1 nm |
| BSA Detection Range | 12.5 µg/mL – 5 mg/mL |
| DNA Detection Limit | 0.01 ng/µL |
| Sample Types | dsDNA, ssDNA, RNA, microRNA, Protein |
| Sample Volume Requirement | 1–20 µL |
| Brand | Thermo Fisher Scientific (Life Technologies) |
|---|---|
| Origin | USA |
| Model | Ion Proton™ |
| Instrument Type | Semiconductor-Based Next-Generation Sequencer |
| Form Factor | Benchtop |
| Primary Application | Whole Human Genome Sequencing, Exome Sequencing, Targeted Panels, RNA-Seq, Epigenetics (e.g., ChIP-seq, methylation analysis) |
| Regulatory Status | For Research Use Only (RUO) |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Jialemei |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | BXD-Pro |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | 2001-B-III |
| Instrument Category | Magnetic Bead-Based Nucleic Acid Purification |
| Automation Level | Dedicated Fully Automatic |
| Batch Sample Capacity | 100 samples |
| Sample Volume Range | 12 mL per tube |
| Fraction Collection Time Range | 1 s – 199 h 59 min 59 s |
| Wavelength Options | 214 nm, 254 nm, 280 nm |
| Flow Rate Range | 1–14,500 mL/h |
| Flow Accuracy | ±1% |
| Pump Speed Resolution | 0.1–150 rpm (bidirectional) |
| OD Detection | Triple-channel real-time A-value output (214/254/280 nm) |
| Fraction Collection Modes | Time-based, Drop-counting, Peak-threshold (0–100 mV) |
| Collection Vial Capacity | 100 × 12 mL tubes with numeric indexing |
| Column Compatibility | Direct interface with GE Healthcare AKTA-scale prepacked columns (1.0×50 cm, 1.0×70 cm, 2.6×50 cm included) |
| System Control | Embedded microprocessor with blue-membrane LCD display |
| Software | PC-based chromatogram acquisition, peak integration, relative quantitation, and report generation (AUC-based normalization) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | Nano-600 |
| Sample Volume | 0.5–2.0 µL |
| Analytes | dsDNA, RNA, BSA |
| DNA Detection Range | 2–17,500 ng/µL (dsDNA) |
| Protein Detection Range | 0–440 mg/mL (BSA) |
| Wavelength Accuracy | ±1 nm |
| Measurement Time | ≤5 s |
| Wavelength Range | 185–910 nm |
| Absorbance Range (10-mm equivalent) | 0.02–300 A |
| Absorbance Precision | ±0.002 A |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Optical Path Lengths | 0.05 mm, 0.2 mm, 1.0 mm (auto-switching) |
| Light Source | Xenon flash lamp (rated lifetime ≥10 years) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm FWHM (at Hg 546 nm) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 270 × 210 × 196 mm |
| Weight | 3.5 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | Nano-900 |
| Detection Time | ≤5 s |
| Wavelength Accuracy | ±1 nm (7.332 Abs at 260 nm) |
| BSA Detection Range | 0.06–1100 mg/mL |
| dsDNA Detection Range | 0–38880 ng/µL |
| Sample Volume Requirement | 0.5–2 µL |
| Wavelength Range | 185–910 nm |
| Absorbance Range (10-mm equivalent) | 0–780 A |
| OD600 Mode | 600 ± 8 nm, 0–4 A |
| Light Source | Xenon flash lamp (≥10-year lifetime) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm (FWHM at Hg 546 nm) |
| Absorbance Precision | ±0.002 Abs |
| Absorbance Accuracy | ±1% (at 7.332 Abs, 260 nm) |
| Optical Path Lengths | Auto-switching 1.0 / 0.5 / 0.1 / 0.05 / 0.02 mm |
| Fluorescence Option | Excitation 460 nm, Emission 525 nm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions | 270 × 210 × 190 mm |
| Weight | 4.6 kg |
| Data Export | USB port, SD-RAM card |
| Brand | Keebio |
|---|---|
| Model | CX2000 |
| UV Wavelength | 254 nm (standard), optional 312 nm & 365 nm lamps |
| UV Lamp Configuration | 5 × 10 W low-pressure mercury lamps |
| Max. UV Irradiance | 5 mW/cm² |
| Exposure Time Range | 0–999.9 min |
| Energy Dose Range | 0–99.99 J |
| Chamber Dimensions (L×W×H) | 340 mm × 260 mm × 150 mm |
| External Dimensions | 360 mm × 340 mm × 310 mm |
| Net Weight | 15 kg |
| Power Input | AC 100–230 V, 50/60 Hz, 60 W |
| Memory Storage | 9 programmable energy/time presets |
| Control Interface | Microprocessor-based with LED display |
| Safety Features | Interlocked UV viewing window and door safety switch |
| Chamber Illumination Area | 920 cm² |
| Compliance | Designed for laboratory use under standard biosafety and electrical safety guidelines (IEC 61010-1) |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-96G |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL format, compatible with full-skirted, half-skirted, non-skirted plates |
| Temperature Range | 4–99.9 °C |
| Max Heating/Cooling Rate | 5.0 °C/s |
| Block Temperature Uniformity | ±0.3 °C at 55 °C |
| Gradient Range | Up to 36 °C, accuracy ±0.5 °C |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Temperature Control Modes | BLOCK mode (block surface temperature), TUBE mode (algorithm-based estimation of actual sample temperature) |
| Ramp Rate Adjustment | 0.1–4.5 °C/s |
| Programmable Cycles | Up to 99 |
| Time Increment/Decrement | 0.1–9 min 59 sec |
| Temp Increment/Decrement | 0.1–9.9 °C |
| Hold Temperature | 4 °C long-term hold |
| Heat Lid Temperature Range | Room temp +5 to 110 °C |
| Heat Lid Accuracy | ±5 °C |
| Heat Lid Display Resolution | 0.1 °C |
| Power Input | 100–240 VAC, 50/60 Hz |
| Max Power Consumption | 600 W |
| Dimensions (D×W×H) | 280 × 187 × 190 mm |
| Net Weight | 7 kg |
| Display | 7-inch color capacitive touchscreen |
| Data Interface | USB port |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Keebio-96P |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well format |
| Max Heating Rate | 6°C/s |
| Temperature Accuracy | ≤ ±0.1°C at 55°C |
| Block Uniformity | ≤ ±0.2°C at 55°C |
| Programmable Ramp Rate | 0.1–5°C/s |
| Gradient Range | Horizontal 1–24°C / Vertical 1–30°C |
| Gradient Temp Range | 30–105°C |
| Block Temp Range | 0–105°C |
| Heat Lid Temp Range | 30–115°C |
| Heat Lid Precision | 0.1°C |
| Max Cycles | 200 |
| Program Storage | 20,000 protocols |
| 4°C Hold Function | Yes |
| Power Input | 100–240 VAC, 50/60 Hz |
| Output Power | 800 W |
| Dimensions (D×W×H) | 380 × 280 × 220 mm |
| Net Weight | 8 kg |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-96S |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL format) |
| Max Heating/Cooling Rate | 5 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C at 55 °C |
| Block Uniformity | ≤ ±0.2 °C at 55 °C |
| Gradient Range | 1–30 °C (±0.3 °C accuracy), 30–105 °C |
| Temperature Control Modes | Block & Tube |
| Programmable Ramp Rate | 0.1–5 °C/s |
| Max Cycles | 100 |
| Time Increment/Decrement | 1–600 s |
| Temp Increment/Decrement | 0.1–10 °C |
| Program Storage | 20,000 protocols |
| 4 °C Hold Function | Yes |
| Power Input | 100–240 VAC, 50/60 Hz |
| Output Power | 700 W |
| Dimensions (D×W×H) | 293 × 190 × 183 mm |
| Net Weight | 5.5 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | KingFisher Duo |
| Magnetic Head Configurations | 1×6 and 1×12 |
| Integrated Thermal Block | Yes |
| Regulatory Status | CE-IVD, FDA 510(k)-cleared for IVD use (when used with approved kits) |
| Compliance | ISO 13485–certified manufacturing |
| Software | Thermo Fisher Connect™ compatible |
| Data Integrity | Audit trail, user access control, electronic signatures per 21 CFR Part 11 requirements |
| Brand | Kurabo |
|---|---|
| Origin | Japan |
| Model | AUTO12S |
| Automation Level | Dedicated Fully Automated |
| Sample Throughput per Run | 1–12 samples |
| Sample Volume Range | 20–200 µL |
| Processing Time per Batch | 20–40 minutes |
| Membrane Thickness | 80 µm |
| Elution Volume | Adjustable (50–200 µL) |
| DNA Fragment Size Range | 175 bp – 97 kb |
| Purity (A260/A280) | >1.7 |
| Integrated UV Decontamination | Yes |
| On-board Thermal Lysis | Yes |
| Footprint | Benchtop, Compact Design |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Model | AUTO24S |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput | 1–24 samples per run |
| Sample Volume Range | 20–200 µL |
| Processing Time (Blood) | ~30 min for 24 samples |
| Processing Time (Tissue) | ~40 min for 24 samples |
| Membrane Thickness | 80 µm |
| DNA Fragment Size Range | 175 bp – 97 kb |
| Purity (A260/A280) | >1.7 |
| Elution Principle | Pressure-driven membrane filtration (no centrifugation, no magnetic beads) |
| Integrated UV Sterilization | Yes |
| On-board Lysis Heating | Yes |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | GF-Q150 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 10-well |
| Heating Rate | 8°C/sec |
| Temperature Accuracy | ±0.5°C |
| Inter-Well Temperature Uniformity | ±0.5°C |
| Reaction Volume | 10 µL |
| Operating Temperature Range (RT-PCR) | 35–65°C |
| PCR Temperature Range | 20–99°C (1.0°C increment) |
| Display | 4-line LCD |
| Built-in Protocols | 12 |
| Power Input | AC 100–230 V, 50/60 Hz (DC 12 V input) |
| Dimensions (W×L×H) | 20 × 20 × 12.5 cm |
| Weight | ≤3.2 kg |
| Data Analysis Modes | Real-time amplification curves, qualitative positive/negative calling, melting curve analysis, ΔCT and ΔΔCT-based gene expression quantification |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | mini480 |
| Price Range | USD 6,800–13,600 (est.) |
| Automation Level | Semi-Automated Assistant |
| Throughput | 1–48 samples per run |
| Sample Volume Range | 20–200 µL |
| Processing Time per Run | 20–40 minutes |
| Membrane Thickness | 80 µm |
| Elution Yield | up to 5 µg DNA from 200 µL whole blood |
| Purity | DNA A260/A280 > 1.7 |
| Workflow Stages | Binding, Washing, Elution (3-pressure-step protocol) |
| Footprint | Benchtop-compatible |
| Optional Modules | 2 mL tube handling (8-channel), high-volume sample processing |
| Brand | Kurabo |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | mini8L |
| Price Range | USD 7,000–14,000 (FOB) |
| Automation Level | Semi-Automatic Assisted |
| Sample Throughput per Run | 1–8 samples |
| Sample Volume Range | 20–200 µL |
| Processing Time per Batch | 10–45 minutes |
| Membrane Thickness | 80 µm |
| Elution Volume | Adjustable (50–200 µL) |
| Typical DNA Yield | Up to 50 µg from 2 mL whole blood |
| Purity (DNA A₂₆₀/A₂₈₀) | >1.7 |
| Extraction Principle | Pressure-Driven Vacuum Filtration via Porous Membrane |
| Compatible Sample Types | Oropharyngeal swabs, whole blood, plasma/serum, cultured cells, fresh/frozen tissue, bacteria, fungi, and microbial lysates |
| Footprint | Benchtop-Optimized (W × D × H: 280 × 320 × 260 mm) |
| Weight | 8.2 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Kurabo QuickGene-610L |
| Price Range | USD 27,000–40,000 (FOB) |
| Automation Level | Dedicated Fully Automatic |
| Throughput per Run | 6 samples |
| Sample Volume Range | 2 mL |
| Processing Time per Batch | 12 minutes |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Model | QuickGene-610L |
| Sample Throughput | 1–6 samples per run |
| Input Volume | Up to 2 mL whole blood |
| DNA Yield | >50 µg from 2 mL whole blood |
| Purity (A260/A280) | DNA >1.7, RNA >1.8 |
| Membrane Thickness | 80 µm |
| Processing Time | ~12 min for 6 whole blood samples |
| Dimensions | 448 W × 332 D × 398 H mm |
| Weight | ~24 kg |
| Operation | Pressure-driven, centrifuge-free, magnetic bead-free |
| Compatible Kit | QuickGene DNA Blood Kit |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickGene-810 |
| Price Range | USD 27,000–40,000 (FOB) |
| Automation Level | Dedicated Fully Automatic |
| Throughput per Run | 8 samples |
| Sample Volume Range | 200 µL |
| Processing Time per Batch | 8 minutes |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickGene-810 |
| Pricing | Upon Request |
| Throughput | 1–8 samples per run, up to 80 samples/hour |
| Sample Volume | 200 µL (e.g., whole blood) or 5 mg (e.g., mouse tail) |
| DNA Yield | >5 µg from 200 µL human whole blood |
| Purity | DNA A₂₆₀/A₂₈₀ > 1.7 |
| Membrane Thickness | 80 µm |
| Processing Time | 6 minutes for 8 whole blood samples |
| Dimensions | 450 × 330 × 400 mm |
| Weight | 21 kg |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-D100 Intelligent |
| Frequency | 23 kHz (adaptive) |
| Display | 7-inch medical-grade capacitive touchscreen |
| Temperature Monitoring | Real-time sample temperature sensing with visual display |
| Cooling Interface | External chiller port for precise thermal control |
| Safety | Auto-fault detection and audible/visual alarm system |
| Power Control | Adjustable ultrasonic power output |
| Timing Control | Programmable sonication time and duty cycle (on/off interval) |
| Brand | Life Technologies |
|---|---|
| Origin | USA |
| Model | SOLiD™ 5500 |
| Configuration | FlowChip-based, addressable channel architecture |
| Sequencing Chemistry | Ligation-based sequencing |
| Accuracy | Up to 99.99% per base (with ECC error correction) |
| Multiplexing Capacity | Up to 96 barcodes per run |
| Software Platform | SOLiD™ System Software Suite v4.x |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11 audit trail requirements (when deployed with validated IT infrastructure) |
| Brand | LIVOBOT |
|---|---|
| Model | EosBot Seq24 |
| Origin | Beijing, China |
| Instrument Type | Integrated Library Prep Platform (Not a DNA Sequencer) |
| Throughput | 8–24 samples per run |
| Regulatory Status | Not a medical device |
| Automation Level | Fully automated, walk-away library construction |
| Compliance | Designed for GLP-compliant laboratories |
| Software Communication | TCP/IP Socket protocol |
| Dimensions | 850 × 1200 × 1050 mm |
| Weight | 260 ± 5 kg |
| Power Supply | AC 100–240 V, 180 VA |
| Operating Environment | 20–30 °C, 20–80% RH (non-condensing), 80–106 kPa |
| Liquid Handling | Single-channel and 8-channel fixed-pitch pipettors (2–500 µL) |
| Positioning Accuracy | ±0.05 mm repeatability |
| Thermal Modules | PCR block (4–100 °C, automated heated lid), incubation (RT +5 to 70 °C), refrigeration (4 ±1 °C) |
| Air Quality Control | HEPA filtration + UV sterilization |
| Safety | Meets Class II biological safety cabinet performance criteria |
| Compatible Platforms | Illumina, MGI/BGI, Thermo Fisher Ion Torrent (via adapter-compatible protocols) |
| Compatible Kits | QIAGEN, Vazyme, TIANGEN, Yeasen, Phalanx, Kangweiji, Abbkine, and other major commercial NGS library prep kits |
| Brand | LND Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Medical Radioisotope Source |
| Model | Co-60 |
| Instrument Type | Gamma Ray Source (Not a PCR Instrument) |
| Activity Range | Customizable per Gamma Knife OEM specifications |
| Physical Form | Sealed Cylindrical Cobalt-60 Pellets in Stainless Steel Capsules |
| Compliance | Meets IAEA RS-G-1.9, NRC 10 CFR Part 35, and IEC 61331-1 standards |
| Brand | Longlight |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | BoFU-100 |
| Quotation | Upon Request |
| Nucleic Acid Fragment Size Range | 100–5000 bp |
| Sample Throughput | 1 |
| Cooling Temperature Range | 0–25 °C |
| Power Adjustment Range | 0–100 % |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | AriaDNA-4 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well microchip format |
| Heating Rate | 7 °C/s |
| Cooling Rate | 7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | <0.3 °C |
| Sample Volume per Reaction | 1–2 µL |
| Minimum Detectable Target | 1–5 DNA/RNA copies per microreactor |
| Thermal Range | 0–99 °C |
| Detection Channels | 4 (FAM/SYBR Green, HEX/VIC, ROX, Cy5) |
| Power Consumption | 100 W |
| Dimensions | 185 × 260 × 285 mm |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | AriaDNA® |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well or 32-well microchip format |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ±0.1 °C |
| Cooling Rate | 10 °C/s |
| Minimum Detectable DNA Copies per Microreactor | 1–5 |
| Total Reaction Time for 45 Cycles | ≤20 min |
| Microreactors per Chip | 16–48 |
| Reagent Volume per Reaction | 0.5–1 µL (2× PCR mix) |
| Integrated Dried-Down Reagents | Yes |
| Detection Channels | Channel 1 (FAM, SYBR Green) |
| Control Interface | External PC with Dedicated PCR Analysis Software & Database |
| Power Consumption | 80 W |
| Dimensions (W×D×H) | 250 × 300 × 190 mm |
| Weight | 5 kg |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Heating Rate | 5°C/s |
| Cooling Rate | 4.5°C/s |
| Temperature Accuracy | ±0.2°C |
| Block Uniformity | ±0.25°C |
| Gradient Range | 30–105°C |
| Gradient Span | 0.1–42°C |
| Block Temperature Range | 0–105°C |
| Heat Lid Range | 30–110°C |
| Sample Capacity | 96 × 0.2 mL tubes (semi-skirted/unskirted), 12 × 8-tube strips, 8 × 12-tube strips, or individual tubes (20–23 mm height) |
| Step Time Range | 1 s – 59 min 59 s (0 = infinite) |
| Display | 5-inch high-resolution color touchscreen |
| Operating System | Industrial-grade embedded OS |
| Data Export | USB flash drive interface |