| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | PFXi-195/880/995 |
| Measurement Method | 9 or 16 Interference Filters |
| Spectral Response | 420–710 nm |
| Bandwidth | 20 nm |
| Color Reproducibility | ±0.0004 / ±0.0002 |
| Transmittance Repeatability | ±0.5% / ±0.25% |
| Saybolt Color Accuracy | ±1 unit |
| Observer Angle | 2° and 10° CIE Standard |
| Measurement Time | ≤25 s |
| Path Length Range | 0.1–153 mm |
| Light Source | Halogen Tungsten Lamp |
| Heating Module (optional) | Up to 95 °C |
| Data Storage Capacity | 32 measurements |
| Dimensions | 17 × 52 × 20 cm |
| Weight | 7–8 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP/582 |
| Pricing | Upon Request |
| Standards Compliance | ASTM D130, ASTM D4048, GB/T 5096, GB/T 7326, SH/T 0232, SH/T 0023, ISO 6251 |
| Temperature Control | PID-regulated metal bath |
| Test Duration | Programmable with audible alarm |
| System Diagnostics | Integrated self-diagnostic firmware |
| Sample Types | Aviation gasoline, jet fuel, automotive gasoline, natural gasoline, solvent naphthas, diesel fuels, distillate fuels, lubricating oils, greases, and other petroleum products with Reid vapor pressure ≤ 124 kPa (930 mmHg) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Equipment Co., Ltd. |
| Model | TP632 |
| Compliance | GB/T 18609, GB/T 7304 |
| Electrode System | Triple-electrode, high-impedance input (Ri ≥ 1 × 10¹² Ω) |
| Measuring Range | 0–260 mg KOH/g |
| Resolution | 0.001 mg KOH/g |
| Accuracy | ≤5% |
| Precision | Conforms to GB/T 18609 |
| Burette Volume | 10 mL |
| Burette Accuracy | ±0.1% F.S. |
| Dispensing Time | (60 ± 10) s F.S. |
| Potential Measurement Range | 0 to ±1999.5 mV |
| Electronic Unit Error | ±0.5 mV or ±0.1% of full scale |
| Operating Environment | 5–35 °C, RH ≤85% |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions (W × D × H) | 350 × 280 × 178 mm |
| Net Weight (main unit) | 8 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP691 |
| Pricing | Upon Request |
| Measurement Principle | Microscopic Filtration Method (Incident-Light Optical Microscopy) |
| Particle Detection Threshold | ≥5 µm (maximum length dimension) |
| Standard Compliance | DL/T 432, GB/T 20082, ISO 4406, NAS 1638, GB/T 18854, ISO 11171, GJB 420B, GJB 380.4A |
| Magnification | 100× with Integrated Illumination |
| Sample Volume | Standardized for Quantitative Membrane Filtration |
| Contamination Grade Range | NAS Class 4 to 12 |
| Dimensions | 410 mm × 310 mm × 230 mm |
| Weight | 6.4 kg |
| Vacuum Filtration | Manual and Optional Automatic Pump Support |
| Filter Membrane | Standard Microporous Membrane (Pore Size: 0.45 µm or 0.8 µm per application) |
| Counting Method | Manual Particle Enumeration under Microscope |
| Brand | TimePower |
|---|---|
| Model | TP692 |
| Origin | Beijing, China |
| Manufacturer | Beijing TimePower Measurement & Control Equipment Co., Ltd. |
| Standard Compliance | ASTM D1500, SH/T 0168, GB/T 6540 |
| Color Scale Range | 0.5–8.0 (ASTM), 1–25 (TimePower Standard Scale) |
| Sample Tube Dimensions | Ø32 mm × 120–130 mm |
| Light Source | Frosted Incandescent Lamp with Precision Color Filters |
| Viewing System | Adjustable Focus and Brightness Optical Eyepiece |
| Standard Color Disc | 26-position wheel (25 calibrated color glass filters + 1 blank reference) |
| Operating Environment | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10%, <500 W |
| Dimensions (W×D×H) | 400 × 320 × 295 mm |
| Weight | 21 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TP791 |
| Pricing | Available upon request |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.2 °C (20–50 °C), ±0.5 °C (50–100 °C) |
| Oscillation Frequency | 275 ± 3 cycles/min |
| Oscillation Amplitude | 35 mm |
| Programmable Modes | Standard (20 min oscillation + 10 min rest @ 50 °C), Fast (5 min oscillation @ 75 °C), Custom (0–99 min oscillation/rest, 0–99 °C setpoint) |
| Sample Capacity | Eight 100 mL syringes or six 250 mL Erlenmeyer flasks |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 5%, 800 VA |
| Dimensions (W×D×H) | 500 × 350 × 385 mm |
| Weight | <25 kg |
| Display | Backlit LCD with real-time parameter feedback |
| Compliance | GB/T 17623–1998, DL 429.4–1991 |
| Brand | TTZH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LT3 |
| Test Temperature Range | Down to −73 °C (with external cryogenic cooling system) |
| Axial Load | 50 N (standard, fixed) |
| Torque Measurement Range | 0–2000 N·mm (custom ranges available on request) |
| Drive System | Electronically controlled high-precision direct-drive motor |
| Torque Sensor | High-resolution digital torque transducer |
| Cooling Interface | Closed-loop cryogenic jacket compatible with liquid nitrogen or mechanical chillers |
| Control Unit | Integrated PLC-based controller with industrial touchscreen HMI |
| Data Acquisition | Real-time synchronized sampling of torque, temperature, and time |
| Software | Windows-based application supporting ASTM D1478 / IP 186/93 compliance reporting, GLP audit trails, and CSV/PDF export |
| Brand | TUNE VOLT |
|---|---|
| Model | TW-2058AKL |
| Principle | Light Obscuration (Optical Blockage) |
| Particle Size Range | 0.8 µm to 500 µm |
| Detection Channels | 8 user-configurable channels |
| Resolution | <10% |
| Repeatability | RSD <2% |
| Viscosity Limit | up to 350 mm²/s (cSt) |
| Sample Volume | 0.2–1000 mL |
| Sampling Accuracy | ±1% |
| Flow Rate | 5–80 mL/min |
| Vacuum Pressure | up to 0.08 MPa |
| Positive Pressure | up to 0.8 MPa |
| Coincidence Limit | 10,000 particles/mL |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions | 400 × 340 × 660 mm |
| Weight | 23.5 kg |
| Origin | Netherlands |
|---|---|
| Model | TV2000AKV |
| Temperature Range | Ambient +5 °C to 130 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±0.01 °C |
| Temperature Resolution | ±0.1 °C |
| Timing Accuracy | ±0.01 s |
| Max Timer Duration | 9999.99 s |
| Bath Capacity | 20 L |
| Heating Power | 200 / 1000 / 1500 W (triple-zone) |
| Construction Materials | AISI 304 stainless steel and PTFE |
| Safety Compliance | CE Directive |
| Dimensions (L×W×H) | 285 × 465 × 585 mm |
| Weight | 40 kg |
| Total Power Consumption | 2800 W |
| Optical Detection | Dual infrared sensors |
| Capillary Types Supported | Ubbelohde and Cannon-Fenske |
| Viscosity Range | 0.3 – 10,000 cSt |
| Calibration Storage | Up to 10 capillary constants |
| Optional Chiller Compatibility | TLC2 (enables 10 °C operation) |
| Standards Compliance | ASTM D445, ASTM D446, IP 71 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | TYS-3672A |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | TP625 |
| Pricing | Upon Request |
| Temperature Control Range | 0–100 °C (0 °C to ambient requires optional chiller) |
| Temperature Stability | ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Bath Capacity | 4 capillary positions |
| Display | 5.0-inch resistive touch LCD |
| Control System | Microprocessor-based PID temperature control |
| Sensors | Imported high-accuracy Pt100 RTD sensors |
| Illumination | Integrated LED backlighting for capillary observation |
| Power Supply | AC 220 V ±10%, 50 Hz ±5 Hz |
| Heating Power | 1500 W |
| Dimensions (W×D×H) | 400 mm × 400 mm × 620 mm |
| Weight | 20 kg |
| Compliance | Designed per GB/T 265–1988 (equivalent to ASTM D445 and ISO 3104) |
| Brand | UIC (United Instruments Corporation) |
|---|---|
| Origin | USA |
| Model | 833 |
| Molecular Weight Range | 100–25,000 Da (in toluene), 100–5,000 Da (in water) |
| Minimum Detectable Concentration | 5 × 10⁻⁵ mol/L (toluene), 2.5 × 10⁻⁴ mol/L (water) |
| Temperature Control Range | Ambient to 130 °C (with optional cryo-circulator for sub-ambient operation) |
| Cell Current Settings | 5, 20, 100 µA |
| Equilibration Time | 2–5 min per sample |
| Sample Volume | 0.25 mL |
| Construction | All-metal hermetic cell housing with dual needle-port inlet system |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | USV |
| Shear Rate Range | up to 1×10⁷ s⁻¹ |
| Temperature Range | 40 °C to 150 °C |
| Rotor/Spindle Material | Tungsten Carbide |
| Stator Material | Tungsten Carbide |
| Gap Setting | Fixed 1 mm |
| Motor Type | DC Servo Motor |
| Max Speed | 20,000 rpm |
| Acceleration Time (0–full speed) | ≤100 ms |
| Torque Measurement | Integrated via microprocessor-controlled motor and electromagnetic clutch |
| Thermal Management | Optimized gap geometry minimizes shear-induced temperature rise |
| Calibration | No routine gap calibration required due to matched thermal expansion coefficients |
| Brand | UOP |
|---|---|
| Origin | USA |
| Packaging | Amber Glass Bottle |
| Storage Requirement | Ambient, Under Nitrogen Atmosphere |
| Compliance | ASTM D1319-22, GB/T 11132-2022 |
| Application | Fluorescent Indicator Adsorption Chromatography of Liquid Petroleum Hydrocarbons |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Model | VARTECTOR |
| Application | ASTM D7843-compliant film potential analysis of phosphate ester fire-resistant hydraulic fluids (EHC systems) |
| Measurement Principle | Reflectance-based colorimetric quantification of deposited insolubles on membrane filters using CIE L*a*b* color space |
| Compliance | Fully aligned with ASTM D7843–21 “Standard Test Method for Quantifying Potential for Insoluble Formation in Phosphate Ester Fluids” |
| Automation Level | Fully automated load control, optical measurement, system verification, and diagnostic reporting |
| Data Output | ΔE, ΔL*, a*, b* values |
| Brand | VISAYA |
|---|---|
| Origin | USA |
| Model | FOAM DDI |
| Compliance | ASTM D892, ASTM D6082, GB/T 12579, SH/T 0722 |
| Imaging System | High-Resolution CCD with LED Illumination Control |
| Sample Volume | ~200 mL in 1000 mL calibrated cylinder |
| Temperature Control Range | Ambient to 99.9 °C |
| Display | Integrated HD Touchscreen Interface |
| Data Output | Exportable CSV/Excel reports with timestamped video log |
| Software Features | Real-time foam height tracking, algorithmic foam volume quantification, manual result override, full-test video recording |
| Origin | Turkey |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Viscol 10 |
| Price Range | USD 13,500 – 27,000 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VKL70 |
| Pricing | Upon Request |
| Brand | Kittiwake |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WDS Series (Custom Configuration Available) |
| Price | Contact for Quotation |
| Key | Brand: PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Pull-Series A |
| Pricing | Upon Request |
| Brand | Xufeng |
|---|---|
| Model | XF-97A |
| Temperature Range | −20 °C to 50 °C |
| Detection Method | Automatic Air-Pressure Detection |
| Compliance | ASTM D6749, ASTM D97, GB/T 3535 |
| Cooling System | Integrated Semiconductor Cascade Cooler |
| Temperature Resolution | 0.1 °C |
| Sensor Type | PT100 Platinum Resistance Thermometer & High-Sensitivity Optical Fiber Detector |
| Display | 7-inch TFT Touchscreen with Embedded Windows-Based UI |
| Data Output | RS-232C Serial Interface, Built-in Dot-Matrix Printer |
| Power Supply | AC 220 V, 50/60 Hz, 1500 W |
| Dimensions (W×D×H) | 250 × 280 × 290 mm |
| Weight | ~25 kg |
| Brand | XOS |
|---|---|
| Model | Clora Online |
| Measurement Principle | Monochromatic Wavelength-Dispersive X-ray Fluorescence (MWD-XRF) |
| Detection Limit | 0.2 ppm (in hydrocarbon matrix), 0.6 ppm (in aqueous matrix) |
| Measurable Range | 0.2 ppm – 3000 ppm |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Sample Types | Crude oil, naphtha, gasoline, diesel, and other liquid petroleum streams |
| Installation Options | Freestanding or wall-mounted |
| Explosion Protection | Configurable to ATEX Zone 1/21 or NEC Class I Div 1/2, Groups B–D, T4 |
| Optical System | Dual hyperbolic curved crystal monochromator |
| Detector Type | High-resolution silicon drift detector (SDD) |
| Excitation Source | Low-power sealed-tube X-ray source |
| Analysis Spot Size | < 5 mm diameter |
| Calibration Requirement | Single-point calibration sufficient for full-range quantification across crude oil and distillates |
| Brand | XOS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Detection Principle | Wavelength-Dispersive X-ray Fluorescence (WDXRF) |
| Portability | Fixed Installation |
| Analyte | Total Sulfur |
| Measurement Range | 0–3000 ppm (extendable to 10 wt% with optional configuration) |
| Analysis Time | 300 s per measurement |
| Limit of Detection (LOD) | 0.5 ppm |
| Accuracy | ≤ ±10% of reading |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with XLS-26 Liquid Autosampler |
| Detection Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Portability | Benchtop (Non-portable) |
| Analyte Types | Total Sulfur and Total Nitrogen |
| Measurement Range | 20 ppb – 10,000 ppm |
| Analysis Time | 2–6 minutes per sample |
| LOD | 10 ppb (S and N) |
| Accuracy | ±2% of reading |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | AP-L1 |
| Temperature Range | Ambient to 170 °C |
| Repeatability | ±0.2 °C (light-colored petroleum), ±0.4 °C (dark-colored petroleum, ASTM Color > 8.0) |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Heating Power | 30 W |
| Stirring Motor Power | 6 W |
| Display | Large Touchscreen LCD |
| Data Storage | 99 test records |
| Interface | RS-232C |
| Dimensions (Controller) | 230 × 430 × 110 mm (W×D×H) |
| Dimensions (Testing Unit) | 230 × 340 × 540 mm (W×D×H) |
| Weight | 20 kg |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | AP-L2 |
| Temperature Range | 0 °C to 170 °C |
| Aniline Point Repeatability | ±0.2 °C (light-colored oils), ±0.4 °C (dark-colored oils |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Heating Power | 30 W |
| Stirring Motor Power | 6 W |
| Display | Large Touchscreen LCD |
| Data Storage Capacity | 99 test records |
| Interface | RS-232C serial port |
| Dimensions (Controller) | 230 W × 430 D × 110 H mm |
| Dimensions (Testing Unit) | 230 W × 340 D × 540 H mm |
| Weight | 20 kg |
| Compliance | GB/T 262, ASTM D611, ISO 2977 |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | CR-M12 GBT41733 |
| Standards Compliance | GB/T 41733-2022, GB/T 17144-2008, ASTM D4530, ISO 10370, ASTM D189, GB/T 268 |
| Measuring Range | 0.10–30.0 wt% carbon residue |
| Temperature Control | Ambient to 500 °C, ±2.0 °C at 500 °C (15 min hold) |
| Gas Flow Control | 100–1000 mL/min, auto-switching between 150 mL/min and 600 mL/min |
| Pressure Regulation | 0–392 kPa (0–4 kg/cm²) |
| Sample Tube Options | Φ20×72 mm (GB/T 41733), Φ12×72 mm & Φ12×35 mm (GB/T 17144) |
| Combustion Chamber Dimensions | Φ85×105 mm |
| Heating Power | 1000 W |
| Waste Bottle Capacity | 200 mL threaded glass bottle |
| Exhaust Port Diameter | Φ12 mm |
| Instrument Weight | 15 kg |
| Dimensions (W×D×H) | 410×250×700 mm |
| N₂ Consumption | ~100 tests per standard 14.7 MPa (150 kg/cm²) cylinder |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | CR-M12 |
| Standards Compliance | GB/T 17144-2008, ASTM D4530, ISO 10370, GB/T 268, GB/T 18610.2-2016 |
| Carbon Residue Range | 0.10–30.0 % (m/m) |
| Combustion Chamber Temp | Ambient to 500 °C |
| Temp Stability | ±2.0 °C at 500 °C (15 min hold) |
| Gas Flow Control | 100–1000 mL/min, auto-switching between 150 and 600 mL/min |
| Pressure Regulation | 0–392 kPa (0–4 kg/cm²) |
| Sample Tube Dimensions | Φ12×35 mm (small), Φ12×72 mm (large) |
| Waste Bottle Capacity | 200 mL, threaded glass |
| Exhaust Tubing Diameter | Φ12 mm |
| Heater Power | 1000 W |
| Instrument Weight | 15 kg |
| Dimensions (Analyzer Unit) | 230×320×425 mm (W×D×H) |
| (Controller Unit) | 230×400×110 mm (W×D×H) |
| Nitrogen Consumption | ~100 tests per standard 14.7 MPa (150 kg/cm²) cylinder |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | DM-L6 |
| Standard Compliance | GB/T 7305, GB/T 7605-2008, ASTM D1401, ISO 6614:1983 |
| Temperature Range | Ambient to 95 °C |
| Test Capacity | 6 samples simultaneously |
| Stirring Speed | 1500 rpm (automatically regulated and monitored) |
| Bath Dimensions | Φ360 × 590 mm |
| Control Panel | 6-channel independent timer with audible/visual alert at 60 min |
| Power Supply | AC 220 V, 50 Hz, 7.5 A |
| Heating Power | 1.5 kW |
| Bath Stirrer Motor | AC 220 V, 25 W |
| Sample Stirrer Motor | DC 24 V, 80 W |
| Cylinder Specifications | Φ32 × 225 mm |