Physical Property Testing Instruments
Filter
Showing 6541–6570 of 12515 results
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | BH-MBN-1000 |
| Measurement Principle | Dual-mode electromagnetic induction + Hall-effect field sensing + high-sensitivity MBN coil detection |
| Excitation Frequency Range | 1 Hz – 10 kHz (programmable) |
| MBN Bandpass Filter | 20 kHz – 2 MHz (adjustable center frequency & bandwidth) |
| Signal Acquisition | Simultaneous real-time sampling of B (flux density), H (magnetic field strength), and MBN voltage waveform |
| Data Output Format | SQLite (.db) with timestamped raw channels, calculated coercivity (Hc), remanence (Br), and MBN RMS/peak amplitude |
| Interface | Wi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 fallback |
| Software Platform | Windows 10/11 native application with GLP-compliant audit trail logging (user action timestamps, parameter change history, export metadata) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | CFT-1 |
| Coercivity Range | 1–50 A/cm |
| Measurement Depth | Up to 30 mm |
| Surface Clearance | Up to 6 mm |
| Measurement Speed | ~3.5 s per reading |
| Excitation Levels | 3 adjustable intensity settings |
| Data Storage | 32 GB internal (DB & CSV export) |
| Display | 2K full-touchscreen interface |
| Compliance | Designed for field-deployable non-destructive evaluation (NDE) of ferromagnetic components |
| Interface | USB, HDMI, sensor port |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CFT-Series |
| Pricing | Upon Request |
| Excitation Levels | 3 Adjustable Steps |
| Lift-off Tolerance | Up to 6 mm |
| Measurement Speed | 3.5 s per reading |
| Penetration Depth | 30 mm |
| Coercivity Range | 1–50 A/cm |
| Display | 2K Full-Touch LCD |
| Storage Capacity | 32 GB (DB + CSV export) |
| Measurement Modes | Manual Keypad / Continuous Auto-Scan |
| Calibration | Intelligent Auto-Calibration Routine |
| Imaging | Built-in 1D/2D Mapping Visualization |
| Data Export | Standard DB & CSV formats |
| Compliance | Designed for ASTM E1444/E709-compliant magnetic particle inspection workflows and ISO 10893-1 non-destructive testing requirements |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MBN-2000 |
| Measurement Principle | Electromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling |
| Signal Bandwidth | 10 kHz – 2 MHz (programmable bandpass) |
| MBN Preamp Gain | 20–80 dB (software-adjustable) |
| Excitation Frequency Range | 1 Hz – 1 kHz |
| Excitation Voltage Amplitude | 0–20 Vpp (programmable) |
| Data Storage Format | SQLite (.db) with timestamped raw MBN, B, and H waveforms |
| Real-time Display | Dual-axis XY plot (H vs. B, MBN envelope vs. H) with scalable axes |
| Connectivity | IEEE 802.11n Wi-Fi (2.4 GHz), USB 2.0 fallback |
| Compliance | Designed per IEC 60404-6 (magnetic measurement methods), compatible with ASTM A932/A932M (standard test method for Barkhausen noise evaluation of ferromagnetic materials) |
| Brand | MAIERIC |
|---|---|
| Model | MBN-BH Grinding Burn Detector |
| Measurement Principle | Magnetostrictive Barkhausen Noise (MBN) + Quasi-Static B-H Hysteresis Loop Analysis |
| Core Components | U-Core Excitation/Detection Probe with Integrated Hall Sensor & Miniature MBN Pickup Coil |
| Signal Acquisition | Simultaneous Real-Time MBN, B(t), and H(t) Waveforms |
| Data Output | .db Binary Format with Timestamped Raw Signals |
| Connectivity | Wi-Fi Enabled PC-Based Control Interface |
| Software Features | Programmable Excitation Frequency/Amplitude, Adjustable MBN Bandpass Filter, Configurable Pre-Amplifier Gain, Dual-Axis Scalable XY Plotting (B vs. H, MBN vs. Time, H vs. Time) |
| Compliance Context | Designed for GLP-aligned magnetic property evaluation per ASTM A342/A342M (Permeability), ISO 643 (Metallographic Hardness Correlation), and internal QC protocols for aerospace & automotive component manufacturing |
| Brand | MAIERIC |
|---|---|
| Model | MTIA-A |
| Measurement Frequency Range | 0.05 Hz – 10 MHz |
| Basic Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | Up to 10,000 samples/sec |
| Resolution | 0.05 Hz (frequency), 0.01 V (voltage) |
| Excitation Voltage Range | 0.02 V – 2 V |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel (up to 128 channels, 16 active simultaneously) |
| Impedance Parameters | Z, R, X, L, C, D, Q, θ |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Analysis Features | Equivalent Circuit Modeling, Time-Domain Sequence Plotting, Multi-Channel Compensation, Sweep & Multi-Channel Mapping |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | PECT-1 PULSED EDDY CURRENT |
| Design | Portable |
| Inspection Method | Pulsed Eddy Current (PEC) |
| Signal Type | Transient Electromagnetic Response |
| Measurement Integration | Encoder-based Position Tracking |
| Lift-off Tolerance | Up to 160 mm |
| Wall Thickness Range | 1–30 mm |
| Non-ferromagnetic Cladding Penetration | Up to 2 mm |
| Cladding Thickness Variation Compensation | ±50% with ≤±2% measurement deviation |
| Imaging Mode | User-configurable 2D grid mapping with real-time coordinate registration |
| Compliance | Designed for ASTM E2884-23 (Standard Guide for Pulsed Eddy Current Examination), ISO 12718:2019 (Non-destructive testing — Vocabulary — Eddy current testing), and GLP-aligned data integrity workflows |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | TEST |
| Measurement Principle | Electromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling |
| Core Functions | Simultaneous MBN Signal Acquisition, Quasi-Static BH Loop Tracing, Coercivity & Remanence Calculation |
| Connectivity | Wi-Fi (IEEE 802.11 b/g/n), USB 2.0 |
| Signal Bandwidth | MBN Channel: 50 kHz – 1.2 MHz (programmable bandpass filter), B/H Channels: DC – 10 kHz |
| Data Output Format | SQLite .db (timestamped raw MBN, B, H waveforms + calculated hysteresis parameters) |
| Software Interface | Windows-based GUI with real-time XY scaling, parameter sweep capability, and export to CSV/MAT |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HXO-T60 Series |
| Application Field | Radioisotope Sample Preparation & Environmental Radiometric Analysis |
| Measurement Target | Organic ³H and ¹⁴C in biological, environmental, and combustible matrices (e.g., plant/animal tissues, soils, polymers, fuels) |
| Operating Temperature | Up to 1200 °C (standard operation at 1000 °C) |
| Thermal Zones | Three independently controlled zones (combustion, buffer, reduction) |
| Gas Control | Dual O₂/N₂ supply with mass flow regulation |
| Water Collection | Dual-stage chilled condensation (recirculating chiller + secondary cold trap) |
| CO₂ Capture | Tandem absorption bottles with high-efficiency bubbling design |
| Reactor Tube | Custom quartz tubing (replaceable, low-memory, low-background) |
| Sample Vessels | Boat-type ceramic crucibles with optimized gas-path geometry for complete secondary combustion |
| Control System | PLC-based automation with HMI touchscreen interface (real-time temperature profiling, data logging, alarm history) |
| Safety | Independent over-temperature protection per zone |
| Chamber Access | Top-hinged dual-door configuration for maintenance and visual inspection |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-G1A |
| Price Range | USD 14,000–28,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated Microwave TGA System |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Uniformity | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Maximum Sample Mass | 500 g |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Cavity Volume | ~20 L |
| Balance Resolution | 0.01 g |
| Exhaust Mode | Negative-Pressure Ventilation |
| Safety Leakage | <5 mW/cm² (per GB 10436 & IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dedicated Microwave TGA |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Balance Capacity | 50 g |
| Balance Resolution | 0.001 g |
| Chamber Volume | ~8 L |
| Microwave Leakage | <5 mW/cm² (Compliant with GB 10436 & IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-R1A |
| Price Range | USD 14,000–28,000 |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MKC-R1B |
| Price Range | USD 14,000–28,000 (FOB) |
| Temperature Range | 0–800 °C (up to 900 °C for short-term operation) |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (continuously adjustable, non-pulsed) |
| Balance Capacity | 50 g |
| Internal Cavity Volume | ~500 mL |
| Microwave Leakage | <5 mW/cm² |
| Compliance | ISO 9001 certified |
| Brand | Makeway |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | lgTIRF |
| Pricing | Upon Request |
| Measurement Principle | Light-guided TIRF (not SQUID) |
| Excitation Delivery | FC-PC fiber-coupled (2 m length) |
| Evanescent Field Depth | ~100 nm |
| Compatible Objectives | Dry, water-immersion, oil-immersion |
| Substrate Compatibility | Glass/silica coverslips, optically clear-bottom dishes |
| Excitation Wavelength Range | 190–1000 nm (UV-capable) |
| Configurable Modes | TIRF, SAFM (shallow-angle fluorescence), MSE (microspot excitation) |
| Calibration | Factory-calibrated, angle-stabilized geometry |
| Switching Speed | Instant mode switching between TIRF/SAFM/MSE/epifluorescence/transmission |
| Brand | Makeway |
|---|---|
| Model | MKW-4900 |
| Origin | Shanghai, China |
| Magnet Type | Electromagnet |
| Temperature Range | 300 °C |
| Measurement Principle | Thermally Stimulated Depolarization Current (TSDC) |
| Voltage Range | ±100 V to ±10 kV |
| Software Platform | aixPlorer / ResoCe Analyzer |
| Interface | GPIB, Ethernet, ODBC |
| Output Format | ASCII |
| Brand | Makeway |
|---|---|
| Model | MKW-4900 |
| Origin | Shanghai, China |
| Magnet Type | Electromagnet |
| Temperature Range | 300 °C (max) |
| Measurement Principle | Thermally Stimulated Depolarization Current (TSDC) |
| Voltage Range | ±100 V to ±10 kV |
| Software Platform | aixPlorer / Resoce Analyzer |
| Interface | GPIB, Ethernet, ODBC |
| Output Format | ASCII |
| Brand | Makeway |
|---|---|
| Model | MKW-KP002 |
| Origin | Shanghai, China |
| Application Environment | Ambient, Controlled Atmosphere, or Humidity-Regulated Conditions |
| Work Function Resolution | 1–3 meV (2 mm tip), 5–10 meV (50 µm tip) |
| Tip-to-Sample Distance Control | Down to ≤400 nm |
| Digital Control Architecture | Full FPGA-based digital signal processing with ON (Off-Null) detection, Height Regulation (HR), Parallel Plate (PP) oscillation mode, Signal Averaging (SA), Work Function Averaging (WA), Quick-Change Tip (QT), Faraday Cage (FC), TTL Output Channel (OC), Data Export to Excel/Origin (DE) |
| Brand | Makeway |
|---|---|
| Origin | Shanghai, China |
| Model | MKW-KP004 |
| Probe Count | 9 integrated Kelvin probes |
| Maximum Substrate Size | 300 mm (12-inch) wafers |
| Energy Resolution | < 1 meV |
| Probe Tip Diameter | 1.4 mm (metal) |
| Angular Position Sensing Resolution | 1° |
| X-Axis Motorized Travel | > 100 mm, Positioning Accuracy: ±50 µm |
| Rotational Axis | Motorized silicon wafer stage with integrated optical encoder |
| Dead-Zone Minimization | Optimized for small wafers and wafer fragments |
| Work Function Calibration Reference | Integrated HOPG or Au reference |
| Environmental Monitoring | Onboard USB-connected temperature & humidity sensor |
| Faraday Cage | Fully integrated gold-plated steel enclosure |
| Software Control | Scriptable measurement engine supporting user-defined protocols |
| Data Output | Full-wafer, half-wafer, quarter-wafer, line-scan, and point-mode surface potential maps |
| Compliance Framework | Designed for GLP-aligned lab environments |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Hydro Insight |
| Instrument Type | Dynamic Imaging System |
| Measurement Range (Standard Magnification) | 1–300 µm |
| Measurement Range (Low Magnification) | 10–800 µm |
| Dispersion Method | Wet Dispersion |
| Camera Resolution | 5 MP (2592 × 1944 pixels, 2.2 µm pixel size) |
| Measured Parameters | Particle Images, Shape Metrics (31 shape descriptors), Width, Elongation, Aspect Ratio, Circularity, Convexity, Solidity, etc. |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mastersizer 2000 |
| Price | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 3 µm |
| Repeatability | <1% RSD |
| Analysis Time | ≤10 minutes |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Mastersizer 3000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Mastersizer 3000+ |
| Dispersion Method | Dry and Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 s |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Model | Mastersizer 3000+ |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 s |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 seconds per analysis |
| Dispersion Method | Dry and Wet Dispersion |
| Data Acquisition Rate | 10 kHz |
| Laser Source | Stabilized He-Ne Laser (632.8 nm) |
| Brand | Malvern PANalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MicroCal PEAQ-DSC Automated |
| Sample Throughput | Up to 50 samples per unattended run |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Sample Format | Standard 96-well microplate compatibility |
| Regulatory Compliance | Designed for 21 CFR Part 11 and EU GMP Annex 11 compliance support |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroCal PEAQ-DSC |
| Sample Throughput | Multiple samples per run (manual loading) |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MicroCal PEAQ-ITC Automated |
| Measurement Mode | Isothermal Titration Calorimetry (ITC) |
| Temperature Range | 2 °C to 80 °C |
| Sample Volume Requirement | As low as 10 μg protein per experiment |
| Throughput | Fully automated operation supporting up to four 96-well plates per unattended run |
| Detection Sensitivity | Sub-micromolar to picomolar dissociation constants (KD = 10⁻² – 10⁻¹² M) |
| Cell Material | Chemically resistant nickel-based alloy |
| Cell Geometry | Optimized coin-shaped reaction cell for efficient mixing and minimal sample dispersion |
| Brand | Malvern PANalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroCal PEAQ-ITC |
| Measurement Mode | Isothermal Titration Calorimetry (ITC) |
| Temperature Range | 2 °C to 80 °C |
| Sample Consumption | As low as 10 µg protein per experiment |
| Affinity Range | 10² M⁻¹ to 10¹² M⁻¹ (K<sub>D</sub> = 10⁻² to 10⁻¹² M) |
| Compatibility | Aqueous and non-aqueous solvents |
| Cell Material | Chemically resistant nickel-based alloy |
| Upgrade Path | Compatible with MicroCal PEAQ-ITC Automated platform |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Morphologi 4 |
| Instrument Type | Static Image-Based Particle Analyzer |
| Lens Count | 5 |
| Measurement Range | 0.5 µm – 1300 µm |
| Sample Dispersion Methods | Dry Powder Dispersion and Wet Dispersion |
| Image Resolution | 18 MP |
| Measured Morphological Parameters | Aspect Ratio, Circularity, Convexity, Extent, Hardness |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Morphologi 4-ID |
| Application Sector | Pharmaceutical |
| Instrument Type | Static Imaging Analyzer |
| Number of Objective Lenses | 5 |
| Measurement Range | 0.5 µm – 1300 µm |
| Dispersion Methods | Dry Powder Dispersion and Wet Dispersion |
| Image Resolution | 18 Megapixels |
| Measured Morphological Parameters | Aspect Ratio, Circularity, Convexity, Elongation, Hardness |