Physical Property Testing Instruments
Filter
Showing 6511–6540 of 12515 results
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LS |
| Pricing | Available Upon Request |
| Overall Dimensions | 230 mm × 200 mm × 1500 mm (L × W × H) |
| Sand Delivery Tube Length | 914 mm (36 in) |
| Tube Internal Diameter | 19 mm (0.75 in) |
| Net Weight | 25 kg |
| Brand | OEM / Third-party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Chamber Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Operating Temperature Range | +5 to +36 °C |
| Max Relative Humidity | ≤85 %RH |
| Nozzle Quantity | 25 |
| Nozzle Diameter | 0.4 mm |
| Nozzle Spacing | 50 mm |
| Spray Arm Radius | 375 mm |
| Spray Arm Inner Diameter | 16 mm |
| Oscillation Angle | Adjustable from ±45° to ±90° (180° total sweep) |
| Oscillation Speed | 60°/s (variable via frequency inverter) |
| Construction | Cold-rolled steel exterior with powder coating |
| Sealing | Dual-layer silicone rubber gasket with rotary waterproof joint |
| Viewing Window | Reinforced organic glass with integrated wiper and LED lighting |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LT-16 |
| Pricing | Upon Request |
| Rebound Accuracy (Relative) | <1.5% |
| Drop Height | 460 mm ±0.5% |
| Guide Tube ID | 40 mm ±4 mm |
| Steel Ball Diameter | Φ16 mm −0.15 mm |
| Steel Ball Mass | 16.7 g ±0.5 g |
| Rebound Range | 10–100% |
| Display | Digital LED |
| Specimen Dimensions | 100 mm × 100 mm × 50 mm |
| Includes | Main Unit, Control System, Two Calibration Steel Balls, Ball Retaining Ring, Four Leveling Feet, Integrated Thermal Microprinter |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LT-sSNOM |
| Price | Upon Request |
| Wavelength Range | 532 nm – 20 µm (with metallic reflective optics) |
| AFM Scanner | Fiber-interferometer-equipped piezoelectric stage, scan range 30 × 30 × 15 µm (@ 4 K) |
| XYZ Sample Nanopositioner | 6 × 6 × 12 mm travel |
| Off-Axis Parabolic Mirror Nanopositioner | 4 × 4 × 6 mm travel |
| Position Sensor Resolution | 200 nm (resistive) |
| Outer Diameter | 49 mm |
| Temperature Range | 10 mK – 300 K |
| Maximum Magnetic Field | 31 T |
| Electrical Contacts | 8-point feedthrough on sample stage |
| Supported AFM Modes | Contact, Dynamic, Non-Contact (ncAFM), Magnetic Force Microscopy (MFM), Conductive AFM (cAFM), Kelvin Probe Force Microscopy (KPFM), Photoinduced Force Microscopy (PRFM), Electrostatic Force Microscopy (EFM) |
| Brand | IMCE |
|---|---|
| Origin | Belgium |
| Model | LT80 |
| Operating Temperature Range | 77 K to 473 K (Liquid Nitrogen–Free) |
| Cooling Method | Closed-Cycle Mechanical Cryocooler |
| Price | €100,000 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LSM Series |
| Price | Upon Request |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LF-TD 180 |
| Instrument Type | Thermo-Hygrometer |
| Humidity Range | 0–100 % RH |
| Temperature Range | –20 °C to +180 °C |
| Humidity Accuracy | ±2.0 % RH (10–90 % RH) |
| Temperature Accuracy | ±0.3 °C (+10 to +60 °C) |
| Output Signals | Dual 4–20 mA (RH and Temp, separately scaled) |
| Power Supply | 12–29 VDC (nominal 24 VDC) |
| Sensor Head Material | Stainless steel |
| Electronics Housing Material | Anodized aluminum |
| IP Rating | IP65 |
| Probe Dimensions | Ø12 mm × 100 mm |
| Electronics Dimensions | 70 mm (W) × 32 mm (H) × 120 mm (D) |
| Cable Length | 1 m (5-pin sensor connector) |
| Brand | LUM GmbH |
|---|---|
| Origin | Germany |
| Model | LUMiSizer 65X |
| Measurement Principle | STEP-Technology (Spatial and Temporal Extinction Profiles) |
| Sample Throughput | 12 positions simultaneously |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (ISO 13318-2) | 20 nm – 100 µm |
| Stability & Sedimentation Velocity Range | 10 nm – 1000 µm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Acceleration Force | 6 × g to 2300 × g |
| Optical Wavelength Options | 470 nm (blue) and 865 nm (NIR) |
| Sample Volume | 0.05 – 2.0 mL |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (via SEPView software audit trail), GLP/GMP-ready |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFrac |
| Quotation | Upon Request |
| Principle | Centrifugal Fracture Testing (Dynamic Load Application via Rotating Rotor) |
| Max. Centrifugal Force Range | 0.1 N – 6.5 kN |
| Rotational Speed Range | 100 – 13,000 rpm |
| Tensile Strength Measurement Range | up to 80 MPa |
| Sample Capacity | 8 parallel specimens |
| Sample Dimensions | max. 30 × 30 × >1 mm³ |
| Bonded Area Diameter | 7 mm, 10 mm or custom |
| Bonded Surface Materials | metallic & non-metallic substrates |
| Specimen Mass Range | 4.1 g – 38.7 g (Cu/W-based reference: ~58 g) |
| Temperature Control Range | −11 °C to +40 °C |
| Measurement Duration | 1 min – 99 h |
| Compliance | ISO 4624, DIN EN 15870, DIN EN 14869-2, JIS K 5600-5-7 |
| Data Interface | USB |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Max. Power Consumption | 1050 W |
| Net Weight | 56 kg |
| Dimensions (W×H×D) | 380 × 296 × 640 mm³ |
| Software Platform | SEPView® v6.x with real-time critical force calculation, statistical comparison, GLP-compliant audit trail, and FDA 21 CFR Part 11-ready user access control |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFuge |
| Price | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge® |
| Measurement Principle | Spatially Resolved Extinction Profile Analysis under Controlled Centrifugal Force |
| Sample Throughput | Up to 8 samples per run |
| Rotor Speed Range | 0–4,000 rpm (variable, programmable) |
| Detection Method | Polydisperse near-infrared (NIR) light transmission at 870 nm |
| Spatial Resolution | 10 µm per data point across 5 cm sample path |
| Data Acquisition Frequency | Up to 1 scan/s (adjustable) |
| Temperature Control | 5–40 °C (±0.5 °C) |
| Sample Volume per Cell | 0.1–2.0 mL |
| Compliance | ASTM D7713-19 (Standard Practice for Stability Evaluation of Dispersions by Centrifugation), ISO 13321 (Particle Size Analysis – Photon Correlation Spectroscopy), GLP-ready with audit trail and user access control |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LUMiReader PSA |
| Pricing | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader PSA |
| Measurement Principle | STEP Technology™ (Spatial and Temporal Extinction Profiles) |
| Acceleration Method | Gravimetric Tilt Enhancement (0°–30° tilt, up to 10× g-equivalent separation rate) |
| Detection | Multi-wavelength LED array (470 nm, 525 nm, 625 nm, 850 nm) |
| Optical Sensors | >9,000 high-resolution photodiodes per detector |
| Sample Volume | 0.5–4.0 mL |
| Concentration Range | 0.00015–75 wt% |
| Particle Size Range (PSD) | 500 nm–300 µm (ISO 13317 compliant) |
| Stability Assessment Range | 200 nm–2000 µm |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | up to 22 g/cm³ |
| Temperature Control | Ambient +3°C to 60°C (±1 K) |
| Tilt Angles | 0°, 5°, 10°, 15°, 20°, 25°, 30° |
| Minimum Acquisition Interval | 0.5 s |
| Data Output | Extinction profiles (E(z,t)), velocity distribution Qᵥ(v), intensity-weighted PSD Qᵢₙₜ(x), volume-weighted PSD Q₃(x) |
| Compliance | ISO/TR 13097, ISO 13317, ASTM D7827, FDA 21 CFR Part 11 (audit trail & electronic signature ready), GLP/GMP-ready architecture |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiSizer |
| Price Range | USD 68,000 – 95,000 |
| Sample Capacity | 12 positions |
| Measurement Principle | Spatially Resolved Extinction Profile Analysis (STEP Technology) |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Sample Volume per Cell | 0.05 mL to 2.0 mL |
| Concentration Range | 0.00015 wt% to 90 wt% |
| Viscosity Range | 0.8 mPa·s to 10⁸ mPa·s |
| Particle Size Range (Stability Mode) | 10 nm to 1000 μm |
| Particle Size Range (ISO 13318-2 Compliant Mode) | 20 nm to 100 μm |
| Density Range | up to 22 g/cm³ |
| Acceleration Range | 6×g to 2300×g |
| Optical Wavelengths | Multi-wavelength source (e.g., 870 nm, optionally 470 nm and/or 650 nm) |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiSizer |
| Price Range | USD 92,000 – 131,500 (converted at ~¥7.6/USD) |
| Sample Capacity | 12 positions |
| Temperature Control | 4 °C to 60 °C (±1 K) |
| Acceleration Range | 6×g to 2300×g |
| Particle Size Range (by STEP-Technology) | 20 nm – 100 μm (stability & sedimentation velocity) |
| Concentration Range | 0.00015 wt% – 90 wt% |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical System | Multi-wavelength transmission scanning (650 nm, optional 470 nm & 870 nm) |
| Measurement Principle | Spatial and temporal extinction profiling (STEP-Technology) |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (software audit trail enabled), GLP-ready |
| Sample Volume | 0.05 mL – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge |
| Centrifugal Acceleration | up to 1200 × g |
| Sample Capacity | 8 positions |
| Temperature Control Range | 4–60 °C (in three programmable zones) |
| Sample Volume | 0.1–2 mL |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | 1–90 vol% |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | 0.01–10 g/cm³ |
| Separation Velocity Resolution | 0.01–1000 µm/s |
| Compliance | ISO 13318-2 |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiReader X-Ray |
| Pricing | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader® PSA |
| Measurement Principle | Spatially Resolved Transmission Analysis (SRTA) with Multi-Wavelength Optical Detection |
| Compliance | Designed for GLP/GMP environments |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiSizer |
| Measurement Principle | Spatial-Temporal Extinction Profiling (STEP) Technology |
| Sample Capacity | 12 positions |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (Stability & Distribution) | 10 nm – 1000 μm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical Wavelengths | Multi-wavelength LED sources |
| Sample Volume per Cell | 0.05 – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Compliance | ISO 13318-2, ISO/TR 13097, FDA 21 CFR Part 11 (via SEPView software), GLP/GMP-ready audit trail |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LUV-I |
| Quotation | Available Upon Request |
| UV Wavelength | 313 nm |
| Rated Power | 0.2 kW |
| Water Pump Flow Rate | 47 L/min |
| Rotating Rack Speed | ≥3 rpm |
| Sample-to-Axis Vertical Distance | 145 mm |
| Weight | 48.5 kg |
| Dimensions (L×W×H) | 895 × 395 × 550 mm |
| Temperature Range | 40–60 °C |
| Compliance | GB/T 14522–1993, ISO 11507:1997 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LUV-II |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LX-500 |
| Price | USD 10,800 (FOB Jiangsu) |
| Internal Chamber Dimensions | 800 × 800 × 800 mm |
| External Dimensions | 1020 × 1350 × 1550 mm |
| Spray Ring Radius | R375 mm or R500 mm |
| Water Pipe Diameter | 16 mm |
| Nozzle Diameter | 0.4 mm |
| Nozzle Spacing | 50 mm |
| Oscillating Pipe Swing Angle | ±60°, ±90°, ±180° |
| Turntable Rotation Speed | 1 rpm |
| Controller | Digital Programmable Oscillation Controller with Imported Frequency Converter |
| Timer | Microprocessor-Based Programmable Timer |
| Water Pressure Regulation | Calibrated Flow Meter |
| Oscillation Parameters | Adjustable Swing Angle and Angular Velocity |
| Water Supply System | Integrated Reservoir + Booster Pump |
| Safety Protections | Leakage Current Protection, Short-Circuit Protection, Motor Overheat Protection |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LY-150 |
| Quotation | Upon Request |
| Max Load Capacity | 2000 kN |
| Load Measurement Accuracy | ±1% FS |
| Maximum Test Length | 14,000 mm |
| Adjustable Crosshead Travel | 10,000 mm |
| Test Speed Range | 1–100 mm/min |
| Rapid Positioning Speed | 200 mm/min |
| Extensometer Gauge Length Range | 0–15,000 mm |
| Elongation Measurement Accuracy | ±0.2% FS ±1 mm |
| Displacement Measurement Range | 0–15,000 mm |
| Displacement Accuracy | ±0.5% FS ±1 mm |
| Hydraulic Cylinder Stroke | 1200 mm |
| Motor Power | 5.5 kW, 3-phase 380 V AC |
| Overall Dimensions (L×W×H) | 8000 × 8000 × 25,000 mm |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M3350-MFI |
| Temperature Range | 50–350 °C |
| Calibration Accuracy | ±0.1 °C |
| Temperature Stability | ±0.5 °C |
| Standard Load Masses | 1.2, 2.16, 3.8, 5, 10, 21.6 kg |
| Test Modes | MFR (Melt Flow Rate) and MVR (Melt Volume Rate) |
| Heating Zones | Dual-zone PID-controlled |
| Interface | RS-485 / RS-232 |
| Power Supply | 230 V / 50 Hz |
| Pneumatic Actuation | Dry air, 3 bar |
| Dimensions (L×W×H) | 60×30×40 cm |
| Weight | 15 kg |
| Software Compatibility | Windows 98/ME/2000/XP |
| Compliance | ASTM D1238, ISO 1133, GB/T 3682, USP <661>, DIN 53735 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5300 |
| Pricing | Upon Request |
| Channel Count | 256–100,000 (in multiples of 256) |
| Voltage Range | 0–5.0 V |
| Max Charge Current | 1.5 A or 2.5 A |
| Max Discharge Current | 2.5 A |
| Voltage Accuracy | ±5 mV |
| Current Accuracy | ±2 mA |
| Energy Accuracy | ±0.2 mAh/hour |
| Min Discharge Cutoff Voltage | 2.0 V |
| Max Charge Voltage Limit | 5.0 V |
| Termination Criteria | 16 programmable conditions including time, voltage, current, dV/dt, capacity, coulombic efficiency, and ΔV |
| Data Logging Interval | As low as 1 minute per cell |
| Independent Channel Control | Yes |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8500 Series |
| Quotation | Upon Request |
| Voltage Range | Up to 1000 V |
| Current Range | Up to 1000 A |
| Minimum Step Time & Data Acquisition Interval | 50 ms (standard), optional sub-50 ms capability |
| Operating Modes | Galvanostatic (CC), Potentiostatic (CV), Power Control (CP), Resistance Control (CR), and hybrid step sequencing |
| Regenerative Energy Recovery | Grid-to-Battery (G2B) and Battery-to-Grid (B2G) bidirectional architecture |
| Software Platform | MACCOR Test Executive v7.x or later |
| Brand | MagArrow |
|---|---|
| Model | MagArrow |
| Type | Airborne Cesium Vapor Scalar Magnetometer |
| Operating Principle | Laser-Pumped Cesium Vapor (Non-Radioactive ¹³³Cs) |
| Measurement Range | 20,000–100,000 nT |
| Gradient Tolerance | 10,000 nT/m |
| Sampling Rate | 1000 Hz (GPS-synchronized 1 PPS) |
| Heading Error | ±5 nT @ 360° |
| Integrated Sensors | High-Accuracy MFAM Magnetometer, Dual-Frequency GNSS Receiver, Tactical-Grade IMU, Radar Altimeter |
| Data Logging | Onboard SD card with WiFi download capability |
| UAV Compatibility | Compatible with drones ≥3 kg payload capacity |
| Maximum Survey Speed | 10 m/s |
| Spatial Sampling Resolution | 1 cm at nominal speed |
| Power Supply | Integrated rechargeable Li-ion battery system |
| Environmental Rating | IP67-rated enclosure |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Array Eddy Current Testing Instrument |
| Inspection Method | Automated Scanning |
| Eddy Current Signal Type | Multi-Frequency Eddy Current |
| Design Form Factor | Portable |
| Number of Channels | Customizable |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MAIERIC |
| Measurement Principle | Combined DC-biased hysteresis loop tracing + high-frequency Barkhausen noise detection |
| Signal Acquisition | Dual-channel synchronized B–H and MBN waveform capture |
| Excitation Frequency Range | 0.1–100 Hz (programmable) |
| MBN Bandwidth | 20 kHz–1 MHz (programmable bandpass filter) |
| Data Output Format | .db (binary database with timestamped MBN, B, H waveforms) |
| Interface | Wi-Fi-enabled real-time PC control |
| Compliance | Designed for ASTM E1444/E2884-compliant magnetic testing workflows |
| Software Features | Real-time x–y scalable plotting of B(H), H(t), and MBN(t) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | BH Hysteresis Loop & Barkhausen Noise Analyzer |
| Measurement Principle | Dual-mode electromagnetic induction + Hall-effect field sensing + high-frequency MBN detection |
| Excitation Frequency Range | 1 Hz – 1 kHz (programmable) |
| Signal Acquisition | Simultaneous B (flux density), H (magnetic field strength), and MBN (Barkhausen noise) waveforms |
| Data Output Format | .db (binary database with timestamped raw channels) |
| Real-time Display | Adjustable XY scaling for B–H loop, H(t), MBN envelope, and time-domain MBN burst trains |
| Connectivity | Wi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 backup |
| Filtering | Programmable bandpass filter (10 kHz – 1 MHz, 3rd-order IIR) for MBN |
| Amplification | Programmable preamplifier gain (20 dB – 60 dB, 10 dB steps) |
| Compliance | Designed per IEC 60404-4 (magnetic materials — methods of measurement of DC magnetic properties) and ASTM A341/A341M (standard test method for direct-current magnetic properties of materials) |