Process Mass Spectrometry Online Mass Spectrometry
Filter
Showing 31–60 of 76 results
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | QGA 2.0 |
| Detection Range | 100 ppb to 100% |
| Scan Speed | Up to 1000 spectra per second |
| Form Factor | Benchtop, Compact Design |
| Compliance | CE-marked, RoHS-compliant construction |
| Software | QGA 2.0 Quantitative Analysis Suite (Windows-based, FDA 21 CFR Part 11 ready) |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | QGA |
| Mass Range | 1–200 amu (standard) |
| Response Time | ≤300 ms |
| Sample Pressure Range | 100 mbar – 2 bar (standard) |
| Detection Range | 1 ppm – 100% |
| Software | QGA Professional Quantitative Analysis Suite |
| Multi-Channel Capability | Up to 80 gas streams (with optional multi-port sampling valve) |
| External Signal Triggering | Yes |
| Data Integration | Supports external sensor inputs (e.g., temperature, pressure, CO analyzers) |
| Spectral Processing | Automated library matching, overlap subtraction, dynamic spectral simulation |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HAPR0128 |
| Operating Pressure Range | Near-ambient (0.1–2 mbar typical for direct inlet |
| Detection Limit | Sub-ppm for most permanent gases and volatiles |
| Mass Range | 1–100 amu (standard), upgradable to 300 amu |
| Scan Speed | Up to 100 mass units per second |
| Data Output Formats | Raw ion current, % composition, ppm/v, nmol/s |
| Multi-stream Capability | Up to 80 gas streams via optional Hiden Multiplexing Valve System (HIDEN MVS-80) |
| Software | QGA Professional Edition with real-time quantification, spectral deconvolution, and external sensor integration |
| Compliance | Designed for GLP/GMP environments |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QIC 20 |
| Pricing | Upon Request |
| Direct Inlet Response Time | <300 ms |
| Continuous Flow Range | 1–20 sccm/min |
| Sample Pressure Range | 100 mbar – 2 bar (standard) |
| Sensitivity | 0.1 ppm (standard), down to 5 ppb (optional) |
| Mass Range | 1–200 amu (standard) |
| optional configurations | 50, 100, 300, or 510 amu |
| Capillary Temperature | Up to 200 °C |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Ion Source Pressure Control | Automatic flow regulation |
| Interface Options | RS232, RS485, Ethernet |
| Software | MASsoft Professional Suite for real-time control, calibration, and quantitative analysis |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | qRGA |
| Mass Range | 1–200 amu |
| Ionization Mode | Threshold Ionization Mass Spectrometry (TIMS) |
| Electron Energy Resolution | 0.1 eV |
| Soft Ionization Range | 0–150 eV |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Detection Limit | ppm-level quantification |
| Shielding | Integrated radiation and magnetic shielding |
| Operational Mode | Dual-mode (conventional scanning + TIMS) |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | Spaci-MS |
| Inlet Channels | 16 |
| Axial Travel Range | 0–300 mm |
| Spatial Resolution | 0.1 mm |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | SpaciMS |
| Inlet Channels | 16 |
| Axial Travel Range | 0–300 mm |
| Spatial Resolution | 0.1 mm |
| Application Domain | Catalytic Reactor Process Monitoring, Transient Gas Analysis, 3D Gas Composition Mapping |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | TGA-MS |
| Interface Type | Capillary Direct-Coupling Interface |
| Dead Volume | Minimized (< 10 µL) |
| Capillary Temperature Control | Up to 300 °C |
| Material of Construction | Inert (High-Purity Stainless Steel, SilcoNert®-treated Surfaces) |
| Gas Handling | Dual-Channel Mass Flow Controlled (H₂, He, N₂, Ar Compatible) |
| Flow Rate Range | 0.1–50 mL/min (Adjustable to Match TGA Effluent Profile) |
| Compliance | ASTM E2550, ISO 11358, USP <1210> |
| Brand | In-situ High-tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CIS-DEMS-DM |
| Quotation | Upon Request |
| Mass Range | 1–100 / 200 / 300 amu |
| Inlet Pressure Range | 1×10⁻⁷ mbar to 10 bar (customizable) |
| Inlet Reduction Stages | 1/2/3-stage selectable |
| Inlet Flow Rate | 0.1–100 sccm |
| Max Inlet Pressure | ≤1.5 bar |
| Inlet Tubing Material | Stainless steel / Quartz / PEEK |
| Heated Inlet Temperature | 120 / 200 / 300 °C |
| Quadrupole Rods | Stainless steel, Ø6 mm × 125 mm |
| Detector | C-SEM / Faraday cup |
| LOD (C-SEM) | <100 ppb |
| Peak Width | 0.5–2.5 amu |
| Ion Source Bake-out Temp | Up to 150 °C |
| Scan Speed | 1 ms–16 s per amu (programmable, min. 1 ms/amu) |
| Vacuum System | Pfeiffer HiPace 80 molecular pump (90,000 rpm) + ACP 20 dry scroll pump |
| I/O Interface | Digital & analog outputs |
| Compliance | Fully compatible with ASTM E1947, ISO/IEC 17025 workflows, and supports GLP/GMP audit trails via optional software modules |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Beishide Instrument Co., Ltd. |
| Model | BSD-MASS |
| Mass Range | 1–100 amu (standard), optional up to 200 or 300 amu |
| Filament | Dual iridium-coated filaments (hot-swap via software) |
| Resolution | <0.5 ppm at 40 amu |
| Scan Speed | 1.8 ms/amu, step size 0.1 amu |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹⁵ Torr (4 s dwell time) |
| Sample Flow Rate | 0.2–2 SCCM (micro-flow optimized) |
| Response Time | <1 s at ≤2 SCCM |
| Splitting System | High-precision electronic flow splitter |
| Ionization | Electron energy software-adjustable (soft ionization mode supported) |
| Turbomolecular Pump | Edwards nTX85, 85 L/s, 100,000 RPM, base pressure 1 × 10⁻¹² mbar |
| Dry Scroll Pump | 20 L/s, base pressure 1 × 10⁻¹ mbar |
| Chamber | Monolithic heated vacuum chamber (no welds), bake-out temperature 150 °C |
| Inlet | 1.2 m passivated stainless-steel capillary, condensation- and clog-resistant design |
| Software | INFICON Vacuum & Process Suite (English), TCP/IP communication |
| Dimensions | 510 mm (H) × 520 mm (L) × 225 mm (W), Weight: 30 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Transpector® RGA Series |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RGA100 / RGA200 |
| Principle | Electron Ionization (EI) Quadrupole Mass Spectrometry |
| Mass Range | 0–200 amu |
| Minimum Sampling Interval | 0.05 amu |
| Mass Resolution (FWHM) | < 0.5 amu |
| Ion Source | EI Source with Yttria-Coated Iridium Filament (Filament Current: 0–4 A) |
| Detector | Electron Multiplier (Gain > 10³) |
| Scan Speed | 5–1000 ms per data point |
| Compliance | Designed for UHV and HV vacuum environments |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HPA 220 |
| Mass Range (Configurable) | 1–100 amu / 1–200 amu / 1–300 amu |
| Operating Pressure Range | 1 × 10⁻⁷ hPa to 50 hPa |
| Detection Modes | C-SEM (Min. Detectable Partial Pressure: 1 × 10⁻¹⁴ hPa) / Faraday Cup (Min. Detectable Partial Pressure: 5 × 10⁻¹² hPa) |
| Quadrupole Dimensions | 6 mm diameter × 100 mm length |
| Base Pumping System | HiPace 80 turbomolecular pump + TC 110 RS controller + MVP 020-3 rotary vane backing pump |
| Vacuum Measurement | PKR 251 full-range gauge |
| Inlet Interface | DN 40 CF flange |
| Power Supply | 115–230 V AC, 50/60 Hz |
| Weight | 15 kg |
| Software | Quadera platform with HPA Add-In module |
| Optional Accessories | Chamber heating unit, DCU 002 molecular pump controller, custom application software, additional full-range gauges |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniStar GSD320 |
| Detection Range | 1–100 u (optional up to 300 u) |
| Ion Source | Hot Cathode Quadrupole |
| Mass Resolution | Unit Mass Resolution (M/ΔM ≥ 150) |
| Detection Limit | < 1 ppm (typical, N₂ background) |
| Interface Temperature | Up to 200 °C |
| Data Acquisition Rate | Up to 100 spectra/s |
| Vacuum Requirement | ≤ 1 × 10⁻⁵ mbar (at analyzer inlet) |
| Pumping System Compatibility | Hicube 300 turbomolecular pump station (integrated or external) |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PrismaPro |
| Detection Limit (C-SEM) | 3 × 10⁻¹⁵ hPa |
| Mass Range | up to 300 amu |
| Detector Options | Faraday Cup (F) and Combined Secondary Electron Multiplier / Faraday (C-SEM/F) |
| Quadrupole Dimensions | 6 mm Ø × 125 mm |
| Operating Pressure Range (C-SEM) | ≤ 5 × 10⁻⁵ hPa |
| Bakeout Temperature | 300 °C |
| Flange | DN 40 CF-F |
| Weight | 2.5–3.2 kg |
| Operating Temperature (Analyzer) | ≤ 200 °C (≤ 150 °C with SEM active) |
| Dwell Time | 1 ms – 16 s/amu |
| Interference at Adjacent Masses | < 10–50 ppm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Thermostar GSD301 |
| Mass Range | 1–300 u |
| Ion Source | Gas-Tight Dual-Filament |
| Inlet Temperature | Up to 350 °C (Quartz Capillary) |
| Detection Modes | Full Scan (1–100 / 1–200 / 1–300 u), MID (128 ions), MCD (128 gases) |
| Vacuum System | Integrated HiPace 80 Turbo-Molecular Pump |
| Software | QuadStar™ (Qualitative & Quantitative, Real-Time & Post-Processing) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniStar / ThermoStar |
| Principle | Quadrupole Mass Filter |
| Response Time | ≤2 s |
| Mass Range Options | 1–100 amu, 1–200 amu, 1–300 amu |
| Inlet Capillary Temperature | Up to 350 °C |
| Inlet Material | Stainless Steel (OmniStar) or Fused Silica (ThermoStar) |
| Pumping System | MVP dry diaphragm pump + HiPace turbomolecular pump |
| Software | PV MassSpec (qualitative & quantitative analysis) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD 350 |
| Mass Range | 1–100 / 1–200 / 1–300 amu (selectable) |
| Inlet Type | Heated stainless-steel capillary (OmniStar®) or heated quartz capillary with Pt gasket (ThermoStar®) |
| Capillary Heating Temperature | Up to 350 °C |
| Gas Flow Rate | 1–2 sccm |
| Sample Pressure Range | ≤1000 hPa |
| Detection Limit (C-SEM) | <100 ppb |
| Resolution | 0.5–2.5 amu (at 10% peak height, adjustable) |
| Analysis Speed | Down to 1 ms/amu |
| Dimensions (L×W×H) | 615 × 358 × 274 mm |
| Weight | ~23 kg |
| Power Supply | 85–265 VAC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiCube RGA |
| Mass Range | 1–300 u |
| Detection Modes | Faraday (F) and C-SEM/Faraday (M) |
| Minimum Detectable Pressure (M) | 3×10⁻¹⁵ hPa |
| Resolution | <10–50 ppm adjacent peak interference |
| Quadrupole Dimensions | 6 mm Ø × 125 mm |
| Operating Temperature (Analyzer) | ≤200 °C (≤150 °C with SEM) |
| Bakeout Temperature | 300 °C |
| Inlet Flange | DN 40 CF-F |
| Data Acquisition | Ethernet interface |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Weight | 25.5–26.2 kg |
| Turbo Pump | HiCube™ Eco (N₂ speed: 67 L/s |
| power | 170 W) |
| Forevacuum Pump | 1 m³/h at 50 Hz |
| Vacuum Gauge | PKR 361 (range: 1×10⁻⁹ – 1×10³ hPa) |
| Integrated Valve | EVN 116 (adjustable conductance: 5×10⁻⁶ – 3×10³ hPa·L/s) |
| Inlet Port | DN 16 ISO-KF |
| Dwell Time | 1 ms – 16 s/amu |
| Peak Ratio Reproducibility | ±0.5 % |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiQuad™ |
| Measurement Principle | Quadrupole mass spectrometry with electron ionization (EI), optimized for real-time, high-speed quantitative gas analysis in industrial process environments |
| Mass Range | 1–128 u, 1–300 u, or 1–512 u (configurable per QMA analyzer variant) |
| Minimum Detectable Partial Pressure | 5×10⁻¹⁶ mbar (QMA 410), 2×10⁻¹⁵ mbar (QMA 430), 1×10⁻¹⁵ mbar (Ar, QMA 400) |
| Sensitivity (Faraday, 1 mA emission) | 1×10⁻³ A/mbar (QMA 410), 2×10⁻⁴ A/mbar (QMA 430), 5×10⁻⁴ A/mbar (QMA 400) |
| Max. Operating Pressure (Faraday) | 1×10⁻⁴ mbar |
| Max. Operating Pressure (SEM) | 1×10⁻⁵ mbar |
| Isotopic Ratio Precision (e.g., ⁴⁰Ar/⁴¹Ar) | < 0.3 ppb SEM resolution |
| Analyzer Temperature | 150 °C (operational), 400 °C (bake-out) |
| Scan Speed | up to 125 µs per atomic mass unit |
| Long-Term Stability | < 0.1 % drift over 8 hours |
| Ion Source | Off-axis biased electron impact source with magnetic field enhancement for low background and high signal-to-noise ratio |
| Detector Options | Faraday cup and secondary electron multiplier (SEM) |
| Interface | Integrated OPC UA server and embedded web browser |
| Software | Quadera® platform for real-time data acquisition, matrix-based concentration calculation, and multi-channel calibration |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HPA 220 / SPM 220 |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD350 O1 |
| Mass Range | 1–100 amu |
| Maximum Inlet Pressure | 1200 hPa |
| Detection Limit | < 100 ppb |
| Gas Flow Rate | 1–2 sccm (0 °C) |
| Analog Inputs | 5 × (−10 to +10 V, 14/16 bit) |
| Capillary | Stainless Steel, 1 m |
| Inlet Heating Temperature | Up to 200 °C |
| Filament | Dual Iridium with Y₂O₃ coating |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD350 O3 |
| Mass Range | 1–100 amu |
| Maximum Inlet Pressure | 1200 hPa |
| Detection Limit | < 100 ppb |
| Gas Flow Rate | 1–2 sccm (at 0 °C) |
| Analog Inputs | 5 × (−10 to +10 V), 14/16 bit |
| Capillary Material | Stainless Steel |
| Capillary Length | 1 m |
| Sample Inlet Heating Temperature | Up to 200 °C |
| Filament Type | Iridium, Dual Y₂O₃-coated |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD350 |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | 1–300 u (standard configuration) |
| Detection Limit | < 10⁻¹⁴ mbar (partial pressure, typical) |
| Response Time | < 1 s (for 10–90% step change, with optimized inlet) |
| Operating Pressure Range | 10⁻⁵ – 10⁻³ mbar (ion source) |
| Interface Temperature | Up to 200 °C (heated capillary inlet) |
| Data Acquisition Rate | Up to 100 spectra/s (full scan) |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OmniStar® GSD 350 / ThermoStar® GSD 350 |
| Mass Range | 1–100 amu / 1–200 amu / 1–300 amu |
| Inlet Capillary | Stainless Steel (OmniStar®) or Quartz (ThermoStar®) |
| Max Capillary Temp | 350 °C |
| Sample Pressure | up to 1000 hPa (mbar) |
| Gas Flow Rate | 1–2 sccm |
| Detection Limit (C-SEM) | < 100 ppb |
| Resolution (10% valley) | Adjustable 0.5–2.5 amu |
| Dwell Time | 1 ms–16 s/amu |
| Mass Peak Separation (e.g., m/z 40/41) | < 10 ppm / < 20 ppm / < 50 ppm |
| Detector | C-SEM and Faraday |
| Analyzer | PrismaPro® Quadrupole Mass Filter |
| Dimensions (L×W×H) | 615 × 358 × 274 mm |
| Weight | 23 kg |
| Software | PV MassSpec |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OMNISTAR™ / THERMOSTAR™ |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ThermoStar GSD301 |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | 1–300 u (standard), upgradable to 500 u |
| Detection Limit | <10⁻¹⁴ mbar (partial pressure, typical) |
| Ion Source | Gas-tight dual-filament design |
| Inlet System | Integrated Pt-capillary inlet, max. temp. 350 °C, vacuum-rated to 5×10⁻³ mbar |
| Pumping System | Dual-stage turbomolecular pumping (HiPace 80 + backing pump) |
| Software | QuadStar™ v4.x (supports ASTM E2554, ISO 11348, GLP-compliant audit trail, 21 CFR Part 11 optional modules) |
| Interface Compatibility | Fully compatible with TA Instruments, Mettler Toledo, NETZSCH, SETARAM, PerkinElmer, LINSEIS, Seiko, Micromeritics, Quantachrome TGA/DTA/DSC/adsorption systems |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | PRO-MS 3600 |
| Detection Range | ppb to 100% (v/v) |
| Detection Principle | Quadrupole Mass Spectrometry |
| Response Time | < 1.5 s (typical for single-point analysis) |
| Ion Source | High-efficiency inertized electron ionization source |
| Quadrupole Material | Passivated stainless steel |
| Inlet System | Multi-stage differential pumping with low-dead-volume valving |
| Software | Real-time spectral acquisition and quantitative analysis suite compliant with GLP data integrity requirements |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | ProMass |
| Form Factor | Semi-portable (carrying case or 6U 19″ rack-mount) |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | Adjustable (typical range 1–100 u or 1–300 u, configurable per application) |
| Detection Limit | Sub-ppb to low-ppb level (dependent on gas species and integration time) |
| Response Time | < 100 ms for single-ion monitoring |
| Ion Source | Electron Impact (EI), 70 eV standard |
| Detector | Dual-mode — Faraday Cup + Secondary Electron Multiplier (SEM) |
| Vacuum System | Integrated turbomolecular pump with backing pump |
| Compliance | CE-marked, RoHS-compliant, designed for industrial environments per IEC 61000-6-2/6-4 |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | PTR-TOF 4000C |
| Principle | Proton Transfer Reaction coupled with Time-of-Flight Mass Spectrometry |
| Detection Limit | Sub-pptv (parts-per-trillion by volume) for selected VOCs/SVOCs |
| Response Time | <100 ms (typical duty-cycle acquisition) |
| Software Compliance | Supports audit trail, user access control, and data integrity per FDA 21 CFR Part 11 requirements |
| Regulatory Alignment | Designed to support ISO 16000-6, EPA TO-15/TO-17, and EU Directive 2008/50/EC monitoring protocols |