Empowering Scientific Discovery

HOGON AKF-3N Coulometric Karl Fischer Moisture Titrator for NMP Solvent in PCB & Lithium Battery Cleaning Applications

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HOGON
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic (China-Made)
Model AKF-3N
Pricing Upon Request

Overview

The HOGON AKF-3N is a dedicated coulometric Karl Fischer moisture titrator engineered for trace-level water quantification in hygroscopic, high-purity solvents—particularly N-Methyl-2-pyrrolidone (NMP)—used extensively in printed circuit board (PCB) cleaning and lithium-ion battery electrode manufacturing. It operates on the internationally standardized coulometric Karl Fischer principle (ISO 8533, ASTM E203, USP ), wherein electrogenerated iodine reacts stoichiometrically with water in an anhydrous methanol-based electrolyte system. The instrument measures the total charge (coulombs) consumed during iodine generation at the anode, directly correlating to water mass via Faraday’s law (1 mole H₂O ≡ 2 × 96,485 C). This method delivers sub-ppm detection capability (typical resolution: 0.1 µg H₂O), exceptional linearity across 1–1000 µg H₂O range, and minimal reagent consumption—critical for routine QC of NMP batches where specification limits commonly fall between 10–100 ppm.

Key Features

  • Coulometric detection architecture with dual-platinum indicator electrodes for precise endpoint discrimination and fast response (<5 s typical drift stabilization)
  • Hermetically sealed, double-compartment titration cell with integrated membrane-separated electrolysis unit to prevent I₂/SO₂ cross-contamination and extend reagent lifetime
  • Automated solvent handling and blank subtraction algorithms compliant with GLP data integrity requirements
  • Pre-programmed liquid-sample method templates—including optimized parameters for NMP, DMF, DMAc, and other aprotic polar solvents per GB/T 6283–2008 and ISO 760
  • Real-time current/voltage monitoring with dynamic endpoint recognition based on dual-threshold polarization detection
  • Integrated balance interface supporting ASTM E899-compliant gravimetric sample introduction (0.0001 g resolution required)

Sample Compatibility & Compliance

The AKF-3N is validated for direct analysis of undiluted NMP (≥99.9% purity), as well as other low-water-content industrial solvents including dimethylformamide (DMF), dimethylacetamide (DMAc), γ-butyrolactone (GBL), and ethylene carbonate (EC). It meets the metrological requirements of ISO/IEC 17025 for calibration traceability and supports full audit trails under FDA 21 CFR Part 11 when paired with HOGON’s optional LIMS-integrated software package. All test reports include mandatory metadata: operator ID, instrument serial number, reagent lot, ambient temperature/humidity (via optional sensor input), sample weight, titration curve, and calculated uncertainty (k=2). Method validation documentation aligns with ICH Q2(R2) guidelines for specificity, accuracy (recovery 98.5–101.2%), precision (RSD ≤ 2.1% at 50 ppm level), and robustness against matrix interference.

Software & Data Management

The embedded firmware supports multi-language UI (English default) and stores ≥10,000 test records with timestamped raw current-time curves. Export formats include CSV (for Excel/SPC analysis), PDF (signed QC reports), and XML (for enterprise LIMS ingestion). Electronic signatures, role-based access control (admin/operator/auditor profiles), and automatic backup to external USB drives ensure compliance with GMP Annex 11 and EU GMP Part IV. Audit trail logs capture all parameter modifications, result deletions, and user logins—retained for ≥36 months per ALCOA+ principles.

Applications

  • Release testing of NMP solvent prior to use in cathode slurry dispersion and PCB flux residue removal
  • In-process monitoring of solvent recovery systems in battery gigafactories
  • Stability-indicating assays for moisture-induced degradation of LiNiCoMnO₂ (NCM) precursors
  • Verification of glovebox atmosphere integrity during electrode drying
  • Supplier qualification audits requiring certified moisture data per JIS K 0070 or IPC-J-STD-033

FAQ

What is the minimum detectable water mass using the AKF-3N?

The theoretical lower limit is 0.1 µg H₂O (equivalent to ~1 ppm in 0.1 g NMP), though practical quantitation limit (LOQ) is defined at 1.0 µg H₂O per injection (per ISO 11843-1).
Does the instrument require daily recalibration with standard water?

No—coulometric systems are inherently absolute methods; verification with certified 1.00 mg/g water standard (e.g., Merck Hydranal®) is recommended before each analytical batch.
Can the AKF-3N analyze solid samples like dried cathode powder?

Not directly; it is optimized for liquids. Solid samples require Karl Fischer oven coupling (e.g., HOGON KF-2100) or azeotropic distillation pre-treatment.
How often must the electrolyte be replaced?

Typical service life is 2–3 weeks under continuous operation (50 tests/day), depending on ambient humidity exposure and NMP batch water content.
Is method transfer possible from volumetric to coulometric KF on this platform?

Yes—the firmware supports both coulometric and volumetric (burette-based) modes via hardware module swap, enabling seamless cross-method validation per USP .