| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-1-FP |
| Pricing | Available Upon Request |
| Detection Principle | Photometric (Colorimetric) Analysis Based on Lambert-Beer Law & Potentiometric Titration |
| Detection Items | Metal Ion Concentration (e.g., Cu²⁺, Ni²⁺, Fe³⁺, Zn²⁺) |
| Analysis Modes | Colorimetric and Potentiometric |
| Analysis Frequency | Once per 20 Minutes |
| RSD | ≤1% (Potentiometric), ≤2% (Colorimetric) |
| Detection Range | 0.01–10 mol/L (as metal ion) |
| Titration Precision | 1 µL (using 20 mL burette) |
| Alarm Indicators | Dual-Color Status Display (Liquid Level, Out-of-Spec Data, Reagent/Consumable Expiry, System Fault) |
| Output Signals | Modbus TCP, RS-232/RS-485, CAN Bus, 4–20 mA Analog Output |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing at ≥10 °C) |
| Wetted Materials | PTFE/FEP |
| Enclosure Rating | IP55 / IP65 (achieved when door is closed and locked) |
| Dimensions (W×D×H) | 500 × 400 × 1600 mm |
| Power Supply | 100–220 V AC, 50–60 Hz, 200 W |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ALT-1-ION |
| Pricing | Available upon Request |
| Detection Principle | Automatic Potentiometric or Colorimetric Complexometric/Precipitation Titration |
| Analysis Frequency | Every 20 Minutes |
| RSD | ≤1% (Potentiometric), ≤2% (Colorimetric) |
| Detection Range | 0.01–10 mol/L (as metal ion concentration) |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Alarm Indicators | Dual-color LED for liquid level, out-of-spec results, reagent expiration, and system fault |
| Output Interfaces | Modbus TCP, RS-232/485, CAN, 4–20 mA analog |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing at ≥10 °C) |
| Wetted Materials | PTFE/FEP |
| Enclosure Rating | IP55/IP65 (when door is closed and locked) |
| Dimensions (W×D×H) | 500 × 400 × 1600 mm |
| Power Supply | 100–220 VAC, 50–60 Hz, 200 W |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ALT-1-TP |
| Quotation | Upon Request |
| Principle | Potentiometric and Colorimetric Titration |
| Measurement Parameters | Zirconium Point (Zr⁴⁺ concentration) and pH |
| Sample Handling | Automated circulation, buffering, dosing, heating, titration, electrode/cup cleaning, reagent replenishment |
| Analysis Frequency | Every 30 minutes |
| RSD (Colorimetric Mode) | ≤2% |
| Detection Range | 0.01–10 mol/L (as metal ion concentration) |
| Titration Precision | ±1 µL (using 20 mL burette) |
| pH Measurement | Electrode-based, real-time in buffer cup |
| Alarm System | Dual-color status indicators for liquid level, parameter out-of-spec, consumables expiry, and fault conditions |
| Output Interfaces | Modbus TCP, RS-232/485, CAN, 4–20 mA analog output |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing at ≥10 °C) |
| Wetted Materials | PTFE/FEP |
| Enclosure Rating | IP55 / IP65 (when door is closed and locked) |
| Dimensions (W×D×H) | 500 × 400 × 1600 mm |
| Power Supply | 100–220 V AC, 50–60 Hz, 200 W |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 3000 W |
| Heating Rate to Max Temp | ≤30 min |
| Heating Element Material | 0Cr27Al7Mo2 Alloy Wire (Kanthal® Super) |
| Internal Chamber Dimensions | 300 × 200 × 120 mm (L×W×H) |
| Insulation Material | Sintered Al₂O₃ Polycrystalline Fiber |
| Thermocouple Type | N-Type (OMEGA®) |
| Control System | AI-PID with Self-Tuning & 30-Stage Programmable Ramp/Soak |
| Interface | VMCI Protocol-Compatible Data Port |
| Safety Features | Over-Temperature Cut-off, Thermocouple Break Detection, Earth Leakage Protection |
| Cooling Rate (from 700 °C) | ≤10 °C/min |
| External Surface Temperature | <50 °C during operation |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | 11521.1310.100 |
| Price | USD 105 (ex-works) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame–Graphite Furnace Hybrid AAS |
| Monochromator | Fixed-grating with selectable slits |
| Optical System | Double-beam |
| Detector | Solid-state CCD array |
| Background Correction | Simultaneous D₂-lamp and Self-reversal (SR) correction |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Resolution | 0.2 nm |
| Cu Detection Limit (Flame) | ≤0.004 µg/mL |
| Cu Characteristic Concentration (Flame) | ≤0.025 µg/mL per 1% absorption |
| Precision (RSD, Cu, A > 0.8) | ≤0.5% |
| Baseline Drift | ≤0.002 A / 30 min |
| Graphite Furnace Max Ramp Rate | ≥3000 °C/s |
| Graphite Furnace Temp Range | Ambient to 3000 °C |
| Cd Characteristic Mass | ≤1 pg |
| Cu Characteristic Mass | ≤10 pg |
| Graphite Furnace Precision (RSD) | ≤3% (Cd, Cu) |
| Lamp Turret | 6-position automatic |
| Auto-sampler Options | 45- or 85-position |
| Gas Control | Dual-path (in-tube / out-tube) inert gas regulation |
| Safety Systems | Real-time flame status monitoring, gas pressure sensors (air, acetylene, N₂O), auto-shutdown on flame failure/flashback, power-interruption cutoff, overtemperature/coolant-flow interlock |
| Dimensions | 700 × 550 × 440 mm |
| Weight | 80 kg |
| Power Requirement | 220 V AC, 6000 W nominal, transient peak up to 8 kW |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 µL |
| Moisture Content Range | 0.001–100% w/w |
| Accuracy | ≤0.15% RSD |
| Minimum Dispensing Volume | 0.2 µL |
| Titration Control Precision | 1.0 µL |
| Electrode Configuration | Dual Platinum Electrode |
| Endpoint Detection | Bipotentiometric (Double-Pt) |
| Average Analysis Time | <3 min per sample |
| Data Storage Capacity | 10 method/sample records |
| Operating Ambient Humidity | ≤80% RH |
| Power Supply | 110–220 V AC, 50 Hz |
| Dimensions (L×W×H) | 320 × 240 × 410 mm |
| Net Weight | 5.5 kg |
| Auxiliary Functions | Titration Delay, Endpoint Hold Delay |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 1.0 µL |
| Moisture Range | 0.001–100% w/w |
| Accuracy (RSD) | ≤1.0% |
| Minimum Dispensing Volume | 5 µL (20 mL High-Precision Burette) |
| Repeatability | ±3.0% RSD |
| Linearity (r²) | ≥0.99 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Capacity | 20 mL |
| Titration Control Precision | ±5.0 µL |
| Power Supply | 110–240 V AC, 50–63 Hz |
| Data Storage | Internal Memory with Auto-Save Function |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic |
| Measurement Resolution | 1 ppm |
| Moisture Content Range | 0.001–100.000% (w/w) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 1/20,000 of burette volume |
| Titration Control Precision | 1.0 µL |
| Sample Analysis Time | < 2 min (avg.) |
| Method Storage | 5 methods |
| Data Storage | 20 test records |
| Burette Capacity | 20 mL with patented piston-driven syringe |
| Electrode | Dual Platinum Electrode |
| Display | Button-operated LCD (Chinese interface) |
| Environmental Humidity Limit | ≤80% RH |
| Power Supply | 110–220 V AC, 50 Hz |
| Net Weight | 5.5 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AKF-1N (Fully Automatic) |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1 ppm |
| Moisture Content Range | 0.001–100% (w/w) |
| Measurement Accuracy | ±0.001 mg H₂O |
| Minimum Dispensing Volume | 1/2000 of Burette Capacity |
| Titration Control Precision | 1.0 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Sample Throughput | ~2 minutes per analysis (average) |
| Burette Capacity | 20 mL |
| Electrode Type | Dual Platinum Electrode |
| Display | Button-Operated LCD with Real-Time Parameter Monitoring |
| Data Storage | 60 test records |
| Method Storage | 5 user-defined methods |
| Environmental Humidity Limit | ≤80% RH |
| Power Supply | 110–220 V AC, 50 Hz |
| Net Weight | 5.5 kg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | AKF-1PLUS |
| Titration Method | Fully Automatic Volumetric Coulometric Hybrid Karl Fischer Titrator |
| Measurement Resolution | 1 ppm |
| Moisture Content Range | 0.001–100% w/w |
| Accuracy | ≤0.3% RSD (2 mL reagent) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Titration Control Precision | 1.0 µL |
| Electrode Type | Dual Platinum Electrode |
| Polarization Voltage Range | 0–2000 mV |
| Polarization Current Range | 0–125 µA |
| Drift Compensation | Auto-tracking & subtraction |
| Display | Monochrome LCD with Chinese interface |
| Dimensions (W×D×H) | 380 × 300 × 330 mm |
| Net Weight | 5.6 kg |
| Power Supply | 95–260 V AC, 50 Hz |
| Ambient Humidity Limit | ≤80% RH |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 3 µg – 30 mg H₂O |
| Measurement Accuracy | ≤ 0.3% (relative) |
| Minimum Dispensing Resolution | 1/2000 of burette volume |
| Electrolysis Current | Auto-controlled, up to 400 mA |
| Detection Sensitivity | 1 µg H₂O |
| Typical Quantitation Range | 10 µg – 10 mg H₂O |
| Maximum Titration Rate | 0.6 mg H₂O/min |
| Endpoint Detection | Visual LED indicator + audible buzzer + automatic stop |
| Display | 5-digit LED |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Moisture Titrator |
| Measurement Resolution | 0.1 µg |
| Moisture Content Range | 0.001–100% (extendable with specialized reagents and accessories) |
| Accuracy | ≤0.15% RSD (at 2 mL titrant consumption) |
| Minimum Dispensing Volume | 0.2 µL |
| Titration Control Precision | 0.2 µL (upgradable via precision burette exchange) |
| Polarization Current Range | ±150 µA |
| Electrode Potential Range | −2000 mV to +2000 mV |
| Valve & Tubing Material | FEP-coated 3-way dual-position solenoid valves with UV resistance and zero-dead-volume design |
| Display | 7-inch capacitive touchscreen (bilingual: English/Chinese) |
| Data Storage | >200 method files, >200 analysis records |
| Interface Options | RS-232C, USB, Ethernet, Web API |
| Environmental Operating Conditions | 5–40 °C, ≤80% RH |
| Dimensions (L×W×H) | 360 × 250 × 320 mm |
| Net Weight | 7.5 kg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-3B |
| Pricing | Upon Request |
| Measurement Principle | Coulometric Titration (Microcoulometry) |
| Sample Form | Liquid |
| Detection Method | Potentiometric Endpoint Detection |
| Display | Color LCD Touchscreen |
| Measurement Range | Bromine Number: 0–300 g Br/100g oil |
| Bromine Index | 1–1000 mg Br/100g oil |
| Resolution | 0.01 mg Br |
| Detection Limit | 0.1 mg Br |
| Accuracy | ±3% (for bromine index ≥1 mg Br/100g oil) |
| Electrolysis Control | Multi-stage adjustable |
| Endpoint Sensor | Dual Platinum Electrodes |
| Cell Volume | 200 mL |
| Stirring Mechanism | Magnetic Stirring |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 320 × 210 × 180 mm |
| Weight | ~3 kg |
| Communication Interface | RS232 |
| Compliance Standards | SH/T 0630–1996, SH/T 1551–2018, SH/T 1767–2008 (2015), GB/T 11136–1989 (2004), GB/T 1815–2019, ASTM D1492 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Analyzer |
| Measurement Principle | Microcoulometric Titration (Electrolytic Bromine Generation) |
| Bromine Number Range | 0–300 g Br/100 g sample |
| Bromine Index Range | 1–1000 mg Br/100 g sample |
| Resolution | 0.01 mg Br |
| Accuracy | ±3% (±0.3 mg Br when bromine index < 1 mg Br/100 g) |
| Repeatability | ±3% |
| Titration Control Precision | ±3% (±0.3 mg Br at low-level detection) |
| Power Supply | 220 V AC / 50 Hz |
| Data Storage Capacity | Internal memory supporting >1000 test records |
| Compliance Standards | SH/T 0630, GB/T 11136, ASTM D1492 |
| Endpoint Detection | Potentiometric (dual-platinum electrode system) |
| Electrolyte Compatibility | Benzene-free electrolyte formulations |
| Display | 7-inch color TFT touchscreen interface |
| Average Analysis Time | ≤60 seconds per sample |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | AKF-3B |
| Power Supply | Not applicable (electrochemical analyzer) |
| Measurement Range | Bromine Number: 0–300 g Br/100 g sample |
| Bromine Index | 1–1000 mg Br/100 g sample |
| Burette Resolution | 0.01 mg Br |
| Detection Limit | 0.1 mg Br |
| Accuracy | ±3% (±0.3 mg Br when bromine index < 1 mg Br/100 g) |
| Endpoint Detection | Potentiometric |
| Compliance Standards | SH/T 0630, GB/T 11136, ASTM D1492 |
| Display | Color LCD touchscreen |
| Electrolyte Compatibility | Benzene-free electrolyte systems |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-3N Coulometric Karl Fischer Moisture Titrator |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Moisture Analyzer |
| Model | AKF-3N |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Range | 1 µg – 200 mg H₂O |
| Sensitivity | ≤ 0.1 µg H₂O |
| Compliance | ASTM D6304, ISO 760, USP <921>, GB/T 4117–2022 |
| Data Interface | USB 2.0 |
| Electrode Configuration | Dual-platinum indicator electrodes + membrane-separated generator electrode |
| Stirring System | Integrated variable-speed magnetic stirrer |
| Cell Design | Hermetically sealed titration cell with desiccant airlock |
| Software Features | GLP-compliant audit trail, user-level access control, automatic calibration logging, CSV export |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-3N |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-3N |
| Titration Mode | Fully Automatic |
| Resolution | 0.01 µg (H₂O mass) |
| Water Content Range | 3 µg – 100 mg |
| Measurement Accuracy | 0.01 µg |
| Minimum Dispensing Volume | 10 µL |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Electrode Type | Electrolytic Electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 µg H₂O |
| Moisture Range | 1 ppm – 100% w/w |
| Accuracy | ≤0.3% RSD |
| Minimum Dosing Increment | 3 µg |
| Repeatability | ≥99.7% |
| Linearity (R²) | ≥0.999 |
| Electrode Configuration | Dual Platinum Electrolysis Electrodes |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AKF-C2 |
| Power Supply | External 12 V DC adapter (compatible with 12 V Li-ion battery or vehicle power) |
| Display | Full-color capacitive touchscreen |
| Input | Digital keypad with one-touch start |
| Titration Principle | Coulometric Karl Fischer method (electrolytic generation of iodine) |
| Speed Control | 6-step adjustable electrolysis current (5 manual + 1 auto mode) |
| Data Handling | Automatic calculation using 5 built-in formulas |
| Advanced Functions | Drift correction, blank subtraction, analysis delay, fixed-duration titration, electrode fault detection, electrolysis efficiency calibration (K-factor adjustment) |
| Compliance | GB/T 6324.8, GB/T 6023, GB/T 7376, GB/T 18619.1, ASTM E1064, ASTM D1492, SJ/T 11723-2018, SJ/T 11568-2016, SH/T 1551 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-C2 |
| Titration Method | Fully Automatic Coulometric Titration |
| Water Content Range | 3 µg – 199 mg (as H₂O mass) |
| Resolution | 0.1 µg |
| Measurement Precision | ±1 mV |
| Repeatability | ≥99% RSD |
| Linearity Correlation Coefficient | ≥0.995 |
| Polarization Voltage Adjustment Range | ±10 mV |
| Electrode Configuration | Dual-electrode Coulometric Cell (Generator & Indicator) |
| Current Control Accuracy | ±1 mA |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 10 test records |
| External Power Option | 12 V DC input compatible with vehicle power systems and rechargeable Li-ion batteries |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Moisture Range | 0.001–100% w/w |
| Measurement Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispensing Volume | 1/2000 of burette capacity |
| Titration Control Precision | 0.01 µg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Moisture Range | 0.001–100% w/w |
| Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispense Volume | 1/2000 of burette capacity |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Electrode Type | Generator/Electrolysis Electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-C6 |
| Titration Mode | Fully Automatic Coulometric Titration |
| Measurement Resolution | 0.01 µg |
| Water Content Range | 0.001–100% w/w |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Repeatability | ±0.3% RSD (n=6, 1000 µg water) |
| Linearity Correlation Coefficient | ≥0.999 |
| Electrolysis Electrode | Dual-platinum generator electrode with integrated indicator electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Coulometric Moisture Analyzer |
| Detection Limit | 0.01 µg H₂O |
| Water Content Range | 0.001–100% |
| Electrolysis Current Range | 1–400 mA (resolution: 0.1 mA) |
| Compliance | Fully GMP/GLP-Compliant Software Architecture |
| User Access Control | Three-Tier Role-Based Authentication |
| Data Integrity | Full Audit Trail, Electronic Signature Support, 21 CFR Part 11 Ready |
| Sample Forms | Liquids, Solids, Gases, and Insoluble Matrices (with optional accessories) |
| Method Storage | Unlimited Customizable Titration Methods |
| Drift & Blank Management | Adaptive Algorithms for High-Accuracy Background Compensation |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Moisture Range | 1 ppm to 100% (w/w) |
| Resolution | 1 µV (electrochemical detection) |
| Accuracy | >99.7% at 1000 µg water |
| Repeatability | >99.7% at 1000 µg water |
| Linearity (R²) | 0.999 |
| Polarization Voltage Range | ±10 mV |
| Electrode System | Dual Platinum Electrolysis Electrodes |
| Current Control Precision | 0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Compliance | Designed for GMP/GLP environments with audit trail, user-level access control, and 21 CFR Part 11–ready software architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Titrator |
| Model | AKF-CAS6 |
| Titration Method | Fully Automated Coulometric Titration |
| Measurement Resolution | 0.01 µg / 0.1 ppm |
| Water Content Range | 3 µg – 199 mg (1 ppm – 100% w/w) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of Burette Volume |
| Repeatability | ≥99.7% RSD |
| Linearity Correlation Coefficient | ≥0.999 |
| Electrode System | Dual Platinum Electrolysis Electrode |
| Titration Control Precision | 0.01 µg |
| Power Supply | 110–240 V AC, 50–62 Hz |
| Data Storage Capacity | Unlimited (Internal SSD + Optional Network Backup) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 3 µg – 199 mg (H₂O mass) |
| Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg pure water) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Repeatability | ±0.3% (for samples containing >1 mg H₂O) |
| Linearity Correlation Coefficient | 0.999 |
| Electrolysis Electrode | Membrane-separated dual-platinum coulometric electrode |
| Titration Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–62 Hz |
| Data Storage Capacity | Unlimited (internal flash memory with timestamped audit trail) |