- All
- Favorite
- Popular
- Most rated
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W40S |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–300°C |
| Temperature Control Accuracy | ±0.1°C |
| Maximum Sample Volume Capacity | 40 L |
| Microwave Power | 0–800 W at 2450 MHz |
| Electric Heating Power | 1600 W |
| Cavity Volume | 40 L |
| Construction | Stainless Steel Monolithic Welded Body with PTFE Anti-Corrosion Coating |
| Evaporation Vessels | One 2000 mL Ceramic Tray (microwave mode) or Two 2000 mL Standard Glass Beakers (electric heating mode) |
| Acid Removal & Ashing Capacity | Three 100 mL Ceramic Crucibles |
| Temperature Monitoring | Dual-mode — Non-contact Infrared + Thermocouple |
| Exhaust System | Corrosion-Resistant Centrifugal Fan (≤60 dB) |
| Control System | PLC-based Intelligent Touchscreen Interface with LED Internal Illumination and Transparent Observation Window |
| Dimensions (W×D×H) | 760 × 550 × 610 mm |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W50 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Cycle | 5 L |
| Total Throughput Capacity | 50–100 L (automated sequential concentration) |
| Microwave Output Power | 3200 W |
| Temperature Sensor | Thermocouple (±1 °C accuracy) |
| Evaporation Vessel | 5 L microwave-compatible ceramic-coated stainless steel dish |
| Cavity Material | Stainless steel with multi-layer PTFE coating |
| Exhaust System | Corrosion-resistant variable-frequency centrifugal blower (2.5 m³/min airflow) |
| Control System | PID controller or optional PLC-based touchscreen interface |
| Safety Interlock | Door-activated power cutoff with multi-layer RF leakage suppression |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W20 Series |
| Instrument Type | Automated Quantitative Microwave Evaporator |
| Temperature Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume Capacity | 24,000 mL |
| Microwave Power | 0–800 W (HXN-W20/W20D) / 0–4000 W (HXN-W20P) |
| Frequency | 2450 MHz |
| Cavity Volume | 24 L (W20/W20D) / 91 L (W20P) |
| Evaporating Dish Standard | 2.9 L (customizable up to 10 L) |
| Surface Area | 0.1 m² (standard) / 0.25 m² (W20P) |
| Microwave Leakage | <5 mW/cm² (per GB 4706.21 & IEC 60335-2-90) |
| Control System | PLC-based with programmable multi-step protocols |
| Display | Color touchscreen (W20D/W20P) or keypad + rotary interface (W20) |
| Noise Level | ≤60 dB(A) |
| Dimensions (W×D×H) | 760×550×610 mm (W20), 760×550×710 mm (W20D), 850×880×650 mm (W20P) |
| Construction | Fully welded stainless steel cavity with PTFE-coated interior |
| Safety | Interlocked door, explosion-resistant design, integrated LED illumination, transparent observation window |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W20 Series (Dual-Channel HXN-W20Y-20 / Quad-Channel HXN-W20W-40) |
| Instrument Type | Automated Quantitative Microwave Concentrator |
| Temperature Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Total Sample Capacity | 4 × 24 L (Quad-Channel Configuration) |
| Microwave Power/Frequency | 1600 W / 2450 MHz (Dual) or 3200 W / 2450 MHz (Quad) |
| Cavity Material | Stainless Steel with PTFE Coating (Evaporation Mode) or Quartz Lining (Ashing Mode) |
| Evaporating Dish Standard | 4 × 2.9 L (Customizable up to 10 L) |
| Cooling/Exhaust | Low-Noise (<60 dB) Corrosion-Resistant Centrifugal Fan |
| Safety Compliance | GB 4706.21–2008, GB 5959.6–2008, Microwave Leakage <5 mW/cm² |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W20 Series (L-11 / T-21 / S-41) |
| Instrument Type | Automated Quantitative Concentration & Ashing System |
| Temperature Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Evaporation Capacity | 4 × 24,000 mL (total, configurable per channel) |
| Microwave Frequency | 2450 MHz |
| Evaporation Power | 800–3200 W (model-dependent) |
| Ashing Power | 800 W |
| Evaporation Cavity Volume | 24 L per channel |
| Ashing Cavity Volume | 1.8 L |
| Microwave Leakage | <5 mW/cm² (per GB 4706.21 & GB 5959.6) |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HXN-W50L |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Volume Capacity | 20 L |
| Microwave Power Output | 3200 W at 2450 MHz |
| Cavity Volume | ~60 L |
| Microwave Leakage | <5 mW/cm² |
| Power Supply | 220/380 V AC, 50 Hz |
| Total Power Consumption | ≤5000 W |
| Dimensions (W×H×D) | 950×800×600 mm (excl. handles) |
| Weight Monitoring | Integrated dynamic liquid-level sensing with auto-refill logic |
| Control Interface | PLC-based system with 10-inch industrial touchscreen |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-G1C1C |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–300 °C (operational up to 500 °C for thermal decomposition) |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 20,000 mL (total volume handling capability) |
| Microwave Output | 800 W continuous, non-pulsed, 2450 MHz |
| Cavity Material | 304 stainless steel with multi-layer PTFE coating |
| Cavity Volume | 10–20 L (configurable per thermal protocol) |
| Heating Method | Non-contact microwave irradiation with IR temperature feedback |
| Vacuum-Assisted Off-Gas Extraction | Supported |
| Rotation Uniformity Control | Motor-driven sample rotation |
| Control System | PLC-based with 7-inch HMI touchscreen, real-time curve logging (time/temperature/power), program storage & recall |