| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HXO-T60 Series |
| Application Field | Radioisotope Sample Preparation & Environmental Radiometric Analysis |
| Measurement Target | Organic ³H and ¹⁴C in biological, environmental, and combustible matrices (e.g., plant/animal tissues, soils, polymers, fuels) |
| Operating Temperature | Up to 1200 °C (standard operation at 1000 °C) |
| Thermal Zones | Three independently controlled zones (combustion, buffer, reduction) |
| Gas Control | Dual O₂/N₂ supply with mass flow regulation |
| Water Collection | Dual-stage chilled condensation (recirculating chiller + secondary cold trap) |
| CO₂ Capture | Tandem absorption bottles with high-efficiency bubbling design |
| Reactor Tube | Custom quartz tubing (replaceable, low-memory, low-background) |
| Sample Vessels | Boat-type ceramic crucibles with optimized gas-path geometry for complete secondary combustion |
| Control System | PLC-based automation with HMI touchscreen interface (real-time temperature profiling, data logging, alarm history) |
| Safety | Independent over-temperature protection per zone |
| Chamber Access | Top-hinged dual-door configuration for maintenance and visual inspection |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MKC-R1B |
| Price Range | USD 14,000–28,000 (FOB) |
| Temperature Range | 0–800 °C (up to 900 °C for short-term operation) |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (continuously adjustable, non-pulsed) |
| Balance Capacity | 50 g |
| Internal Cavity Volume | ~500 mL |
| Microwave Leakage | <5 mW/cm² |
| Compliance | ISO 9001 certified |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-R1A |
| Price Range | USD 14,000–28,000 |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dedicated Microwave TGA |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Balance Capacity | 50 g |
| Balance Resolution | 0.001 g |
| Chamber Volume | ~8 L |
| Microwave Leakage | <5 mW/cm² (Compliant with GB 10436 & IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-G1A |
| Price Range | USD 14,000–28,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated Microwave TGA System |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Uniformity | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Maximum Sample Mass | 500 g |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Cavity Volume | ~20 L |
| Balance Resolution | 0.01 g |
| Exhaust Mode | Negative-Pressure Ventilation |
| Safety Leakage | <5 mW/cm² (per GB 10436 & IEC 62233) |