| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLD3500 |
| Instrument Class | Radiation Dose Meter |
| Instrument Form Factor | Portable |
| Detectable Radiation Types | Photons (E > 5 keV), Neutrons (thermal–100 MeV), Beta particles (E > 70 keV) |
| Measurement Quantities | Photon dose, neutron fluence, beta dose |
| Dose Range | 10 μGy – 1 Gy (linear response) |
| Sensitivity Threshold | < 1 kGy |
| Temperature Range | 15 °C – 600 °C |
| Heating Rate | 1–50 °C/s |
| Temperature Stability | ±1 °C |
| System Stability | ±0.005% |
| Operating Ambient | 15–40 °C |
| Output Units | nC, gU, mrad, mrem, mGy, Gy, µSv, mSv, Sv |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | TPJ-24-G |
| Pricing | Available Upon Request |
| Measurement Range | 0–2000 W/m² |
| Spectral Response | 300–3000 nm (0.3–3 µm) |
| Sensitivity | 7–14 µV/(W·m⁻²) |
| Internal Memory | 30,000 records (Flash) + optional 4 GB microSD card |
| Data Transmission | GPRS wireless upload with configurable interval or on-demand push |
| Power Supply | 7.4 V / 2.8 Ah Li-ion battery (with low-voltage warning & charging protection) |
| external DC input | 8.4 V ≥1000 mA |
| GPS | Integrated module for automatic geotagging of each measurement |
| Sensor Expansion | Up to 32 analog/digital sensors via IP67-rated hub |
| Operating Temperature | -20°C to +60°C |
| Display | Dot-matrix LCD with full Chinese menu interface |
| Software | Cloud-based C/S architecture platform supporting web and mobile (iOS/Android) access, data visualization (trend curves & tabular reports), export (CSV, PDF), audit-ready storage, and remote firmware updates |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TRAC |
| Pricing | Upon Request |
| Brand | TRAD (Tests & Radiations) |
|---|---|
| Origin | France |
| Model | RayXpert 2.0 |
| Core Engine | Geant4 v11.2-based Monte Carlo simulation platform |
| Particle Support | γ, β⁻/β⁺, e⁻/e⁺, n, p, d, t, α, ³He, heavy ions |
| Source Types | Point, surface, volume, spectrum (user-defined or library-based), complex energy spectra |
| Geometry | Native 3D CAD modeling + STEP import (ISO 10303-21) |
| Material Definition | Custom elemental composition, density, mixture, isotopic enrichment |
| Output Metrics | Dose rate (Gy/h), absorbed dose (Gy), equivalent dose (Sv), fluence, particle tracks, path-integrated dose |
| Analysis Tools | Isodose contours, cross-sectional dose profiles, detector response simulation, multi-source/spectrum superposition, variance-reduced convergence monitoring (FOM) |
| Compliance Framework | Supports GLP-aligned audit trails, input/output logging, parameter versioning |
| Automation | Python API, CLI mode, JSON export for materials/sources, scriptable input generation |
| Licensing | Modular (SILVER/GOLD/PLATINUM), floating network license available |
| OS | Windows 10/11 (64-bit) |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Model | Tri-Carb 4810 |
| Detection Principle | Coincidence Counting + Time-Resolved Liquid Scintillation Counting (TR-LSC) |
| Background Reduction | Optimized via Pulse-Shape Discrimination and Dual-Photomultiplier Coincidence Logic |
| Quench Correction Method | tSIE (transformed Spectral Index of the External standard) |
| Multichannel Analyzer (MCA) Resolution | 4096 channels |
| Detection Efficiency | ≥63% for ³H, ≥95% for ¹⁴C |
| Sample Volumes Supported | 4 mL, 7 mL, 20 mL |
| Sample Capacity | 408 × 20 mL vials or 720 × 4/7 mL vials |
| Compliance | Meets ASTM D7282, ISO 9001–certified manufacturing environment, fully compatible with GLP/GMP data integrity requirements including 21 CFR Part 11–compliant audit trail and electronic signature support |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TF2 |
| Price Range | USD 695–1,390 |
| Frequency Range | 40 Hz to 100 kHz (AC Magnetic & Electric Fields), 20 MHz to 6 GHz (RF/Microwave) |
| Measurement Accuracy | ±4% (AC Magnetic Field, 50/60 Hz), ±5% (AC Electric Field, 50/60 Hz), ±20% (RF at 1 GHz) |
| AC Electric Field Range | 1–1000 V/m |
| AC Magnetic Field Range | 0.1–100.0 mG |
| RF Power Density Range | 0.1–1000.0 mW/m² |
| Display Resolution | 0.1 mG / 1 V/m / 0.1 mW/m² |
| Power Supply | 9V Alkaline Battery (IEC 6LR61) |
| Battery Life | ~20 h (backlight off), ~12 h (backlight on) |
| Dimensions | 136 × 75 × 38 mm |
| Weight | 230 g (including battery) |
| Brand | Tydex |
|---|---|
| Origin | Russia |
| Model | GC-1P / GC-1T / GC-1D |
| Detector Type | Pneumatic Thermal Terahertz Detector |
| Wavelength Range | 0.3–8000 µm |
| NEP @ 15 Hz | 0.8–1.4 × 10⁻¹⁰ W/Hz¹ᐟ² |
| Responsivity @ 15 Hz | 1.0–1.5 × 10⁵ V/W |
| Aperture Diameter | 6.0 mm |
| Input Cone Diameter | 11.0 mm |
| Max Incident Power | <10 µW |
| Optimal Modulation Frequency | 15 ± 5 Hz |
| Window Material (GC-1P) | HDPE |
| Window Material (GC-1T) | TPX (Polymethylpentene) |
| Window Material (GC-1D) | Diamond |
| Dimensions (L×W×H) | 126 × 45 × 87 mm |
| Weight | 0.8 kg |
| Compliance | CE-marked, ISO/IEC 17025 traceable calibration available upon request |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | Radiation |
| Detection Principle | Geiger-Müller Tube with Mica End-Window |
| Measuring Ranges | 0.5–5.0–50 mR/h (three auto-ranging scales) |
| Alpha Energy Range | up to 2.5 MeV (≥80% detection efficiency at 3.5 MeV) |
| Beta Energy Threshold | ≥150 keV (75% efficiency) |
| Gamma/X-ray Sensitivity | ≥10 keV through mica window |
| Power Supply | 9 V alkaline battery (typical 2000 h operation) |
| Display | Analog needle meter with LED visual alarm and audible buzzer |
| Weight | 0.25 kg |
| Compliance | CE-marked, compliant with IEC 60846-1:2014 for portable radiation survey meters |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WBGT-2006 |
| Pricing | Upon Request |
| Dry-Bulb Range | 10–60 °C (±0.5 °C) |
| Natural Wet-Bulb Range | 5–40 °C (±0.5 °C) |
| Black Globe Range | 20–120 °C (±0.5 °C @ 20–50 °C |
| Globe Diameter | 150 mm |
| Globe Emissivity | ≥0.95 (matte black surface) |
| Wet-Bulb Sensor | Cylindrical, Ø6 ±1 mm × L30 ±5 mm |
| Data Logging Duration | Up to 100 hours |
| Interface | USB 2.0 |
| Display | Full Chinese GUI |
| Compliance | GB/T 4200–1997, ISO 7243:1989 |
| Brand | Xianxian Da |
|---|---|
| Model | CIT-3000DPP |
| Detector Type | Scintillation-based Gamma Spectrometer |
| Crystal | NaI(Tl), Φ50 mm × 50 mm (optional Φ75 mm × 75 mm) |
| Energy Resolution | ≤6.5% FWHM at 662 keV (¹³⁷Cs) |
| ADC Sampling Rate | 20–80 MS/s |
| Pulse Shaping Time | 1–5 µs |
| MCA Channels | 256–4096 |
| Differential Nonlinearity | <0.1% |
| Integral Nonlinearity | <0.01% |
| Programmable Gain | 1–4095 steps |
| Digital Pulse Processing (DPP) | Threshold-free acquisition architecture |
| Communication Interfaces | CAN, RS-232, USB 2.0, TCP/IP |
| Power Consumption | <1 W |
| Operating Temperature Range | –10 °C to +50 °C |
| Compliance | Meets IEC 61000-4 EMC standards |
| Brand | Xianxinda |
|---|---|
| Model | CIT-3000F |
| Detector Type | Gamma Spectrometer |
| Scintillator | NaI(Tl), Ø75 mm × 75 mm |
| Shielding | Lead chamber, 100 mm wall thickness, 200 mm internal diameter |
| MCA Channels | 1024 / 2048 |
| Energy Resolution | <7% at 661 keV (¹³⁷Cs) |
| Differential Nonlinearity | 0.2% |
| Integral Nonlinearity | 0.01% |
| Pulse Shaping Time | 2.0 µs |
| Background Count Rate | ≤6 cps (50–3000 keV) |
| Measurement Uncertainty | ≤10% (k=2) |
| Stability | Peak shift ≤1% over 24 h |
| Sample Mass | 500 g |
| Acquisition Time Range | 10–65,500 s |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤95% |
| Power Consumption | <300 mA |
| Host Dimensions | 31 × 32 × 13 cm |
| Host Weight | 3 kg |
| Software | Windows-based spectral analysis suite with Chinese GUI, Excel export, calibration database, and inverse matrix quantification algorithm |
| Compliance | JJG 417–2006, GB 6566–2010, CNAS-accredited calibration certificate issued by China National Institute of Metrology (CNIM) |
| Brand | Xinxianda |
|---|---|
| Model | CIT-2000F |
| Instrument Type | Gamma Spectrometer |
| Detector | 50 mm × 50 mm NaI(Tl) Scintillation Crystal |
| Energy Range | < 4 MeV |
| Energy Resolution | < 8% @ 662 keV (¹³⁷Cs) |
| Dose Rate Range | 0–9999 µSv/h (Environmental Monitoring) / 0–9999 γ (Uranium Exploration) |
| Sensitivity | ≥350 cps per µSv/h |
| Stability | ≤±7% over 8 h operation |
| Accuracy | Absorbed Dose Rate Deviation ≤±10% vs. Theoretical Value |
| Operating Temperature | –10°C to +50°C |
| Relative Humidity | ≤95% RH |
| Dimensions | 360 mm × 90 mm × 220 mm |
| Weight | 2.0 kg |
| Power Consumption | <160 mW |
| ADC | 16-bit, 1 MSPS |
| Data Storage | Up to 2 million spectral records |
| Measurement Modes | Timed & Manual |
| Display Units | µSv/h, γ, µSv, CPS, ppm, % |
| Housing | Anodized Aluminum Alloy |
| Battery | Rechargeable Li-ion with Low-Voltage Warning |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000F |
| Detector | Ø75 mm × 75 mm NaI(Tl) crystal |
| Energy Resolution | ≤8% at 662 keV (¹³⁷Cs) |
| Uranium (eU) Range | 2–1000 ppm |
| Thorium (eTh) Range | 3–1000 ppm |
| Potassium (eK) Range | 0.5–100 wt% |
| U Channel | 1.60–1.90 MeV |
| Th Channel | 2.40–3.00 MeV |
| K Channel | 1.30–1.60 MeV |
| Total Spectrum | 0.5–3.00 MeV |
| Accuracy | eU/eTh ≤ ±7%, eK ≤ ±12% |
| Pulse Shaping Time | 2 µs |
| Data Storage | 2 million spectra |
| Power | Rechargeable 2.4 Ah Li-ion battery, ≤200 mW |
| Operating Temp | 0–50 °C |
| Relative Humidity | ≤90% at 50 °C |
| Weight | Control Unit 0.6 kg, Detector 3.0 kg |
| Interface | RS-232 |
| Brand | Xinxianda |
|---|---|
| Model | KJD-2000R |
| Detection Principle | Electrostatic Collection + Alpha Spectrometry |
| Radionuclides | ²²²Rn and ²²⁰Rn |
| Measurement Range | 3.7–925,000 Bq/m³ (0.1–25,000 pCi/L) |
| Detection Sensitivity | 0.2 CPM/pCi/L |
| Pump Flow Rate | 1 L/min |
| Measurement Duration | 10 min (soil), 60 min (air or water) |
| Uncertainty | ≤10% (k=2) |
| Data Storage | 1,000 alpha spectra |
| Power Supply | 12 V/7 Ah rechargeable battery (≥10 h operation) or AC 220 V |
| Operating Environment | 0–50 °C, ≤95% RH |
| Dimensions | 300 × 200 × 180 mm |
| Weight | 5 kg |
| Detector Type | Passivated implanted planar silicon (PIPS) alpha spectrometer with gold-silicon surface barrier configuration |
| Calibration Sources | Certified radon chamber or liquid ²²⁶Ra standard |
| Brand | Yueweitang |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TBM-3S |
| Instrument Type | Radiation Survey Meter / Dose Rate & Contamination Monitor |
| Detection Capabilities | α, β, γ radiation |
| Detector | 2-inch flat pancake GM tube |
| Measurement Units | cpm (counts per minute) and mR/h (milliroentgen per hour) |
| Range Settings | 0–500 / 0–5,000 / 0–50,000 cpm (corresponding to 0–0.15 / 0–1.5 / 0–15 mR/h) |
| Housing | Ruggedized 2.5-inch form factor |
| Operation | Single-hand ergonomic design |
| Linearity | Full-scale linear response across all ranges |
| Brand | YUFENGRUILIN |
|---|---|
| Model | YFR-105 |
| Measurement Principle | Diffusion-type scintillation cell |
| Detection Range | 5–100,000 Bq/m³ |
| Minimum Detectable Concentration | 5 Bq/m³ |
| Uncertainty | ±15% (k=2) |
| Response Time | ≤30 min (typical), down to 10 min under optimized conditions |
| Power Supply | Rechargeable 5000 mAh Li-ion battery (48 h continuous operation) + AC adapter |
| Operating Environment | −10 °C to +40 °C, ≤90% RH |
| Dimensions | 140 × 170 × 60 mm |
| Weight | 0.8 kg |
| Data Storage | 19,999 measurement records |
| Communication Options | Optional RS-485 interface (customizable for continuous online monitoring), optional Bluetooth printer support |
| Brand | YUFENGRUILIN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YFR-800A |
| Instrument Category | Alpha Spectrometry Sample Preparation System |
| Instrument Type | Laboratory Benchtop Unit |
| Sample Form | Aqueous Solutions |
| Input Voltage | 220 V ±10% AC, 50 Hz |
| Power Consumption | 200 W |
| Electrolysis Current Range | 0.1–5.0 A (adjustable in 0.02 A increments) |
| Current Stability | < ±0.2 A under load |
| Current Display Resolution | 0.01 A (LCD) |
| Electrode Rotation Speed | 60–600 rpm (continuously adjustable) |
| Speed Stability | ±5% (torque-dependent) |
| Speed Drift | < 1 rpm |
| Speed Display | Digital rpm readout (LCD) |
| Electrode Material | XM150 Platinum Disk Electrode with Protective Cap |
| Anode/Cathode Configuration | Rotating Pt anode + Fixed stainless steel cathode disk |
| Ventilation Rate | 200 L/min |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −25–60 °C |
| Dimensions (W×H×D) | 325 × 650 × 325 mm |
| Weight | 7 kg |
| Construction Materials | Polyethylene terephthalate (PET), polyoxymethylene (POM), nylon, PVC, stainless steel, copper, nickel-plated brass |
| Front Panel | AG4 anodized aluminum |
| Safety | Zero-current shutdown on main power disconnection |
| Included Accessories | 2 × Pt wire electrodes, 50 electroplating disks, adjustable electrode holder, sample bottle fixtures (20 mL & 50 mL options), passive timer (1 min–9 h 59 min with audible alert), high-flow ventilation option available |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-WLY |
| Pricing | Available Upon Request |
| Detection Limit | ≤0.01 ng/mL (3σ definition) |
| Uranium Measurement Range | 0–20 ng/mL (extendable to 100 ng/mL via dilution) |
| Linearity | R² ≥ 0.999 |
| Precision | RSD ≤ 5% |
| Stability | ≤7% RSD over 8 h at 2 ng/mL post 1-h warm-up |
| Data Storage | 4,000 measurement records |
| Interface | USB 2.0, 100Base-T4 Ethernet |
| Display | 7-inch color TFT touchscreen |
| Printer | Integrated thermal printer (57 mm × 40 mm paper) |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 450 × 350 × 185 mm |
| Net Weight | 10 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RP6000 |
| Price Range | USD 700–1,400 |
| Instrument Class | Dose Rate / Integrated Dose Meter |
| Form Factor | Portable |
| Measured Medium | Ambient Air (Gas Phase) |
| Detector Type | NaI(Tl) Scintillation Crystal (φ30 × 25 mm) |
| Radiation Types | X-ray and Gamma-ray |
| Dose Rate Range | 0.01–200.00 µSv/h |
| Cumulative Dose Range | 0.00 µSv–9.99 Sv |
| Sensitivity | ≥350 CPS per µSv/h |
| Energy Response Range | 48 keV–3 MeV |
| Relative Accuracy | ≤±8% at 200.00 µSv/h |
| Measurement Duration | Adjustable from 5 to 120 seconds |
| Alarm Thresholds | User-Configurable for both dose rate and cumulative dose |
| Display Units | µSv/h (ambient dose equivalent rate), µGy/h (air kerma rate), µSv (cumulative dose), CPS (count rate) |
| Power Supply | Two D-size alkaline batteries |
| Power Consumption | ≤200 mW (excluding backlight) |
| Weight | 1.30 kg (including batteries) |
| Dimensions | 420 × 180 × 88 mm |