Radiation Measurement Instruments
Filter
Showing 211–240 of 325 results
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9180 |
| Frequency Range | 6–18 GHz |
| Resolution | 100 Hz |
| Reference Frequency Accuracy | < 2 ppm |
| RF Input | 50 Ω, N-type female (SMA compatible) |
| VSWR (10 dB attenuation) | < 2 |
| VSWR (0 dB attenuation) | < 3 |
| Attenuator Range | 0–45 dB (5 dB steps) |
| Preamp Gain | 20 dB |
| Max Input (Sinusoidal AC) | 137 dBμV (1 W, non-damaging) |
| Preselector Bands | 6–9 GHz, 9–12 GHz, 12–15 GHz, 15–18 GHz |
| IF Bandwidths | 3/10/30/100/300 kHz (–6 dB) |
| Displayed Average Noise Level (DANL), RBW = 1 MHz, preselector ON, preamp ON | PK < 8 dBμV (typ. 6 dBμV) |
| DANL, RBW = 1 MHz, preselector ON, preamp OFF | PK < 28 dBμV (typ. 26 dBμV) |
| DANL, RBW = 10 kHz, preselector ON, preamp ON | PK < –12 dBμV (typ. –14 dBμV) |
| Spurious Response | < 20 dBμV |
| Measurement Accuracy (S/N > 20 dB) | ±2.0 dB (6–18 GHz) |
| Interface | High-speed optical fiber |
| Operating Temperature | –5 °C to +45 °C |
| Power Supply | 10–15 VDC, 2.5 A |
| Rechargeable Li-ion Battery | 4 h continuous operation |
| Dimensions | 235 × 105 × 105 mm (L × W × H) |
| Weight | 2.2 kg |
| Brand | PMM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | C4 |
| Price | Upon Request |
| Frequency Range | 1 Hz to 40 GHz |
| Measurement Resolution | 0.01 V/m |
| Electric Field Measurement Range | Determined by Connected E-Field Probe Specifications |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EHP-50B & EHP-50C |
| Frequency Range | 5 Hz – 100 kHz |
| Axes | X/Y/Z triaxial measurement |
| Calibration Data Storage | Built-in EEPROM |
| Interface | Fiber-optic (compatible with PMM 8053A analyzer) |
| Power Supply | Rechargeable battery (up to 7 days in autonomous monitoring mode) |
| Sensor Architecture | Orthogonal magnetic coils + orthogonal parallel-plate capacitors |
| DSP Engine | Integrated digital signal processor with 7 selectable resolution bandwidths (RBW) |
| Spectral Analysis | Real-time FFT-based spectrum display on host unit |
| Compliance | Designed for IEC 61786-1, ICNIRP 2010/2020, IEEE C95.1, and EU Directive 2013/35/EU |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP-408 |
| Frequency Range | 1 MHz to 40 GHz |
| Electric Field Measurement Range | 0.8 V/m to 800 V/m |
| Measurement Resolution | 0.01 V/m |
| Isotropy (typ.) | ±1 dB @ 200 MHz |
| H-Field Rejection | >20 dB |
| Dynamic Range | >60 dB |
| Overload Protection | >1000 V/m |
| Calibration Memory | Built-in EEPROM |
| Dimensions | 317 mm × Ø52 mm |
| Weight | 90 g |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP 601 |
| Frequency Range | 10 kHz – 9.25 GHz |
| Electric Field Measurement Range | 0.5 – 500 V/m |
| Resolution | 0.01 V/m |
| Overload Protection | > 1000 V/m |
| Dynamic Range | > 60 dB |
| Isotropy | ±0.5 dB |
| Amplitude Flatness | ±0.4 dB |
| Sensor Type | Six Monopole Antennas (Triaxial X/Y/Z) |
| Weight | 23 g |
| Dimensions | 21 mm (sphere diameter) × 16 mm (sensor length) × 53 mm (total length) |
| Operating Temperature | –10 °C to +50 °C |
| Power Supply | Rechargeable Li-ion Battery or External DC Input |
| Temperature Compensation | 0.1 °C per °C |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP-602 |
| Frequency Range | 5 kHz to 9.25 GHz |
| Electric Field Measurement Range | 1.5 V/m to 1500 V/m |
| Measurement Resolution | 0.01 V/m |
| Isotropy (Typical) | ±0.2 dB |
| Frequency Response Flatness (with correction enabled) | ±0.4 dB (50 MHz – 7.5 GHz) |
| Dynamic Range | >60 dB |
| Weight | 22 g |
| Operating Time | Up to 100 h (rechargeable Li-Mn battery) |
| Communication | Duplex optical fiber (up to 60 m) |
| Sensor Type | Spherical symmetric monopole array (6-axis isotropic sensing) |
| Overload Protection | >3000 V/m |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | L3-32 |
| Max. Current Rating | 500 A |
| Compliance | CISPR 16-1-2, IEC/EN 55016-1-2, MIL-STD-461G (CS114), ANSI C63.4 |
| Configuration | 3-phase, 4-wire (L1/L2/L3/N/PE) |
| Frequency Range | 9 kHz – 30 MHz |
| Insertion Loss | >60 dB (typical, 150 kHz–30 MHz) |
| Impedance | 50 Ω |
| Brand | Polimaster |
|---|---|
| Origin | USA |
| Model | PM1208M |
| Instrument Type | Portable |
| Measurement Type | Ambient Dose Equivalent Rate (H*(10)) and Cumulative Ambient Dose Equivalent (H*(10)) |
| Dose Rate Range | 0.01–9999.99 µSv/h |
| Dose Range | 0.001–9999.99 mSv |
| Energy Response | 0.06–1.5 MeV |
| Waterproof Rating | IP68 (100 m submersion) |
| Display | Dual-mode LCD with electroluminescent backlight |
| Data Storage | Non-volatile memory |
| Communication | Infrared (IR) interface compliant with ISO/IEC 14443 |
| Alarm | Audible and visual threshold alerts for dose rate and cumulative dose |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Quotation | Upon Request |
| Instrument Type | Dosimeter / Dose Rate Meter |
| Measurement Range | 0–100 μGy·h⁻¹ |
| Angular Response (¹³⁷Cs) | 0°–120° (±25%), 90°–180° (±35%) |
| Energy Response | 50 keV–3 MeV (±20%) |
| Cosmic Ray Response (vs. RSS-111 reference ionization chamber) | ±15% |
| Dose Rate Accuracy vs. Theoretical Calculation | ±10% |
| Drift After 8-h Continuous Operation at Room Temperature | ≤±7% |
| Total Error (−10°C to +40°C) | ≤±30% |
| Operating Temperature | −10°C to +40°C |
| Relative Humidity | ≤90% at +30°C ±2°C |
| Power Supply | Six No. 1 dry cells |
| Console Dimensions | 180 mm × 113 mm × 155 mm |
| Probe Dimensions | 210 mm × 120 mm × 45 mm |
| Console Weight | ~2 kg |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Power Plant Seawater Radiation Environmental Monitoring System |
| Pricing | Upon Request |
| Instrument Class | Dose Rate Meter / Activity Monitor |
| Instrument Type | Online Continuous Monitoring System |
| Measured Medium | Liquid (Seawater) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RADALERT100 |
| Instrument Type | Dose Rate / Exposure Rate Meter |
| Detection Capabilities | Alpha, Beta, Gamma, and X-ray Radiation |
| Calibration Source | Cs-137 (Gamma) |
| Dose Rate Range | 0.001–110.0 mR/hr or 0.01–1100 µSv/hr |
| Display | 4-digit LCD with mode indicators |
| Counting Range | CPM: 0–350,000 |
| CPS | 0–3,500 |
| Total Count | 1–9,999.00 |
| Sensitivity | 1,000 CPM per mR/hr (Cs-137) |
| Accuracy | ±10% typical, ±15% maximum |
| Audible/Visual Alarm | User-adjustable threshold up to 50 mR/hr and 160,000 CPM |
| Output Interface | Dual-purpose 3.5 mm mini-jack (CMOS-compatible TTL pulse output) |
| Power Supply | 9 V alkaline battery (2160 h typical at background |
| Dimensions & Weight | 150 × 80 × 30 mm, 225 g (including battery) |
| Compliance | CE-marked per EU Directive 2014/30/EU (EMC) and 2014/53/EU (Radio Equipment), compliant with IEC 60846-1:2014 for portable radiation protection instrumentation |
| Brand | Radcal (USA) |
|---|---|
| Origin | USA |
| Model | Rapid-Gold+ Touch Pro |
| Dimensions | 114 × 92 × 158 mm |
| Weight | 700 g |
| Display | 5″ capacitive TFT LCD (800×480) |
| Battery | 5.5 Ah Li-polymer, >8 h operation |
| Connectivity | USB 2.0 (Micro-B), Wi-Fi 802.11b/g/n (2.4 GHz, WPA2) |
| Storage | 16 GB internal flash (>100,000 exposures) |
| Compliance | IEC 61674, EN 61326-1:2013 (Group 1, Class B), EN 61000-4-x series |
| Operating Temp | 15–35 °C |
| Humidity | ≤80% RH or ≤20 g/m³ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation and Contraband Detection System |
| Model | RadEye CD |
| Detector Type | RadEye SX with NaI(Tl) Scintillation Detector |
| Measurement Capability | Simultaneous detection of concealed contraband (e.g., tobacco, explosives, alcohol) and radioactive materials |
| Measurement Range | 5–10 cps (background), 50–100 cps (contraband presence) |
| Sensitivity | ≥5 cps minimum detectable signal above background |
| Analysis Channels | Dual-channel spectral analysis |
| Typical Background Count Rate | 5 cps |
| Effective Measurement Time | 1 second per acquisition |
| Regulatory Compliance | Designed for customs, border security, and port-of-entry applications in accordance with IAEA TS-G-1.2 and ANSI N42.34 standards |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | RadEye GR |
| Instrument Type | Portable Dose Rate Meter |
| Detector Type | Sodium Iodide (NaI) Scintillator |
| Wireless Range | 100 m |
| Detector Battery Life | 1300 h |
| Display Unit (RadEye R) Battery Life | 600 h |
| Operating Temperature | –25 °C to +50 °C |
| Compliance | Meets ANSI N42.33, IEC 60846-1:2014, and EU Directive 2013/59/Euratom for portable radiation monitoring devices |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRM-100 |
| Instrument Type | Portable Dose Rate Meter |
| Measured Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Detector | Halogen-quenched Geiger-Müller Tube with Mica End-window (1.75″ / 45 mm diameter, density 1.5–2.0 mg/cm²) |
| Wall Material | 0.012″ stainless steel (Grade 446) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Display | 4-digit LCD with mode indicators |
| Audio Feedback | Adjustable click-per-count (muteable) |
| Visual Feedback | LED flash per count |
| Interface | 3.5 mm output jack (CMOS-compatible TTL pulses) |
| Power | One 9 V alkaline battery (typical lifespan: 2160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RadScan 900+ |
| Price | USD 1,280 (FOB Hamburg) |
| Detection Types | α, β, γ, X-rays |
| Dose Rate Range | 0.01–1000 µSv/h |
| Pulse Rate Range | 0–30,000 cpm / 0–5,000 cps |
| Cumulative Dose Range | 0.001 µSv–999,999 Sv |
| Sensitivity | ≥108 pulses per µSv/h (Co-60) |
| Operating Temperature | −40 °C to +75 °C |
| Dimensions | 170 × 74 × 30 mm |
| Weight | 250 g |
| Power | 3 × AAA alkaline batteries (30-day continuous operation) |
| Compliance | CE Directive 2014/30/EU (EMC), 2014/53/EU (RED), FCC Part 15 Subpart B |
| Calibration Interval | 5 years (traceable to PTB standards) |
| Brand | PKSAIR |
|---|---|
| Origin | USA |
| Model | Ranger USB |
| Instrument Type | Portable Dose Rate Meter |
| Detector Type | Halogen-filled Geiger-Müller Tube (1.77" / 45 mm effective diameter |
| mica window density | 1.4–2.0 mg/cm²) |
| Measurement Range | 0.001–100.0 mR/hr |
| Sensitivity | 3340 CPM/mR/hr (referenced to Cs-137) |
| Sample Form | Solid |
| Compliance | CE certified |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | A307 |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Country of Origin | Imported |
| Model | FilterMate |
| Pricing | Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MicroBeta2 |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Type | Imported Instrument |
| Model | Quantulus GCT 6220 |
| Pricing | Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Country of Origin | Imported |
| Model | Tri-Carb Series (4810TR / 4910TR / 5110TR) |
| Pricing | Upon Request |
| Brand | Revvity |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | WIZARD2 |
| Detection Limit | Not Specified |
| Stability | Not Specified |
| Resolution | Not Specified |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RH800 |
| Pricing | Upon Request |
| Detector | GM Tube |
| Energy Response | ±30% (50 keV–1.3 MeV) |
| Dose Equivalent Rate Range | 0.01 µSv/h–1.00 mSv/h |
| Cumulative Dose Equivalent Range | 0.01 µSv–99.99 mSv |
| Measurement Time | 5 s |
| Relative Error | ±20% (¹³⁷Cs) |
| Alarm Threshold | User-Configurable |
| Power Supply | Two AA batteries |
| Current Consumption | <2 mA |
| Operating Temperature | −10 °C to +40 °C |
| Temperature Drift | ±10% |
| Humidity Drift | ±15% at 95% RH (+40 °C) |
| Dimensions | 118 × 65 × 25 mm |
| Weight | <100 g |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RJ-3 |
| Price | USD 700 (approx.) |
| Instrument Type | Field Strength Meter / Dosimetry Rate Meter |
| Frequency Range | 20–200 MHz |
| Measurement Range | 0–450 V/m (3-range switchable: 0–30 V/m, 30–150 V/m, 50–450 V/m) |
| Overall Measurement Uncertainty | ≤ ±30% |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤ 80% RH |
| Power Supply | Two 6 V F22 alkaline stacked batteries |
| Form Factor | Portable |
| Instrument Dimensions | 170 mm × 100 mm × 45 mm |
| Packaging Dimensions | 450 mm × 370 mm × 150 mm |
| Weight | ~3 kg |
| Frequency Range | 30 Hz–2000 Hz |
|---|---|
| Electric Field Range | 0–20,000 V/m |
| Measurement Accuracy | ≤ ±1.5 dB |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤ 80 % RH |
| Power Supply | Rechargeable 8.4 V battery or 9 V alkaline (6F22) |
| Form Factor | Portable |
| Weight | 550 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SabreASC |
| Pricing | Upon Request |
| Brand | Sanpu |
|---|---|
| Model | FD216 |
| Origin | Beijing, China |
| Manufacturer | Sanpu Instrument Co., Ltd. |
| Detection Principle | ZnS(Ag) Scintillation + Photomultiplier Tube (PMT) |
| Measurement Modes | Active Pump-Driven Air/Solid/Water Sampling |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Background Count Rate | ≤0.3 cpm |
| Radon-in-Air Range | 3–100,000 Bq/m³ |
| Soil Radon Range | 300–300,000 Bq/m³ |
| Radon Exhalation Rate Range | 0.001–10.000 Bq/(m²·s) |
| Water Radon Range | 0.003–100 Bq/L |
| Repeatability Error | ≤5% (at 2000 Bq/m³, 65% RH, 25°C) |
| 8-h Drift | ≤10% |
| Power Supply | Rechargeable Li-ion battery (30 h continuous operation) or AC adapter |
| Operating Temp | −10°C to +40°C |
| Max. Relative Humidity | ≤90% at +40°C |
| Data Storage | 2000 records |
| Display | LCD |
| Interface | USB + Bluetooth printing |
| Dimensions | 330 × 210 × 170 mm |
| Weight | 5 kg (main unit) |
| Calibration & Traceability | Certified by National Institute of Metrology (NIM), China |
| Brand | SARAD |
|---|---|
| Origin | Germany |
| Model | RTM 1688-2 |
| Sampling Method | Active sampling |
| Measurement Range | 0–10 MBq/m³ |
| Detection Limit | Not specified (contextually implied as sub-10 Bq/m³ in slow mode) |
| Response Time | 95% in 12 min (fast mode) |
| Flow Rate | 0.30 L/min |
| Detector Type | Integrated semiconductor alpha spectrometer with electrostatic collection chamber |
| Sensitivity | 3 cpm/(Bq/m³) (fast mode) / 7 cpm/(Bq/m³) (slow mode) |
| Chamber Volume | ~250 mL |
| Humidity Independence | Yes, no desiccant required |
| Data Storage | 2047 measurement records |
| Compliance | Designed for ISO 11665 series, ICRP recommendations, and EPA/WHO radon assessment protocols |
| Brand | SARAD |
|---|---|
| Origin | Germany |
| Model | RTM2200 |
| Sampling Method | Active |
| Measurement Range | 0–10,000,000 Bq/m³ |
| Minimum Detectable Concentration | 1 Bq/m³ |
| Response Time | 12 min (Po-214 excluded) / 120 min (Po-214 included) |
| Detector Type | Silicon semiconductor alpha spectrometer with deep ion implantation |
| Sensitivity | 3.2 cpm/(kBq/m³) (Po-214 excluded) / 7 cpm/(kBq/m³) (Po-214 included) |
| Chamber Volume | ~135 mL |
| Built-in Pump Flow Rate | 300–800 mL/min |
| Operating Interface | 240 × 128 pixel graphical touchscreen |
| Data Storage | SD card with GPS tagging (optional) |
| Communication Interfaces | USB, RS232 (supports GSM modem, ZigBee, or Wi-Fi adapter upgrade) |
| Dimensions | 235 × 140 × 255 mm |
| Environmental Sensors (standard) | Air temperature, relative humidity, flow rate, barometric pressure, battery status |