Radiation Measurement Instruments
Filter
Showing 121–150 of 319 results
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HT-WY |
| Pricing | Upon Request |
| Detection Limit | ≤0.01 ng/mL (3σ definition) |
| Uranium Measurement Range | 0–20 ng/mL (extendable to 100 ng/mL via dilution) |
| Linearity Coefficient | ≥0.9995 |
| Precision (RSD) | ≤5% |
| Stability (8-h RSD at 2 ng/mL) | ≤7% after 1-h warm-up |
| Data Storage Capacity | 4,000 data points |
| Interface | USB 2.0, 100Base-T4 Ethernet |
| Printer | Integrated thermal printer (57 mm × 40 mm paper) |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 15 kg |
| Brand | Kipp & Zonen |
|---|---|
| Model | Brewer MkIII |
| Optical Design | Dual Monochromator |
| Wavelength Range | 286–363 nm (Ozone & SO₂ measurement bands) |
| Stray Light Rejection | <1×10⁻⁷ (typical) |
| Tracking System | Dual-axis solar tracker with azimuth/elevation control |
| Data Acquisition | PC-controlled via RS-232/USB, 24/7 unattended operation capable |
| Compliance | Meets WMO/GAW requirements for total ozone and UV spectral irradiance monitoring |
| Software | GW-Basic v3.75f (Kipp & Zonen validated, firmware-integrated) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CA2 |
| Spectral Range | 0.3–3 µm (with quartz window) / 0.2–50 µm (bare detector) |
| Sensitivity | 7–20 µV/W/m² |
| Impedance | 20–200 Ω |
| Output Range | 0–30 mV |
| Maximum Irradiance | 2000 W/m² |
| Response Time (63%) | < 6 s |
| Response Time (95%) | < 18 s |
| Operating Temperature | −40 °C to +80 °C |
| Relative Humidity | 0–100 % non-condensing |
| Power Supply | 12 VDC |
| Mounting Rod | 170 mm × 10 mm diameter |
| Field of View (90% energy acceptance) | 20° |
| Housing Material | Brass with conical reflector and removable quartz window |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CGR4 / SGR4 |
| Spectral Range (CGR4) | 4500–42000 nm |
| Spectral Range (SGR4) | 4400–50000 nm |
| Sensitivity | 5–15 µV/W/m² |
| Response Time | 18 s |
| Window Heating Offset (CGR4) | < 4 W/m² |
| Zero Offset B | < 2 W/m² |
| Temperature Dependence of Sensitivity (−20 to +50 °C) | < 1 % |
| Operating Temperature Range | −40 to +80 °C |
| Net Irradiance Range | −250 to +250 W/m² |
| Field of View | 180° |
| Non-linearity Error | < 1 % |
| Analog Output (SGR4) | 4–20 mA / 0–1 V (mV/W·m²) |
| Digital Output (SGR4) | 2-wire RS-485 Modbus® |
| Power Supply (SGR4) | 5–30 VDC |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CGR4 |
| Pricing | Upon Request |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CHP1 / SHP1 |
| Spectral Range | 200–4000 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time (63%) | < 5 s (CHP1), < 0.7 s (SHP1) |
| Response Time (95%) | < 2 s (SHP1) |
| Zero Offset (5 K/h temp. change) | < 1 W/m² |
| Temperature Dependence of Sensitivity | < 0.5 % (-20 to +50 °C for CHP1 |
| Field of View | 5 ± 0.2° |
| Operating Temperature | -40 to +80 °C |
| Non-linearity Error | < 0.2 % |
| Maximum Irradiance | 4000 W/m² |
| ISO 9060 | 2018 Classification: Secondary Standard, Spectral Responsivity Class B |
| Output Options | CHP1 — 10 kΩ thermistor + Pt-100 |
| Power Supply | 5–30 VDC (SHP1), polarity-reversal protected |
| Internal Heating | Low-power, non-interfering with detector thermal stability |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CHP1 |
| Price | Upon Request |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CM4 |
| Spectral Range | 300–2800 nm |
| Sensitivity | 4–10 µV/W/m² |
| Response Time | < 8 s |
| Zero-Offset A | < 4 W/m² |
| Zero-Offset B | < 15 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 20 W/m² |
| Temperature Dependence of Sensitivity (-20 °C to +150 °C, over any 50 °C interval) | < 3 % |
| Operating Temperature Range | -40 °C to +150 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Integrated Pt-100 Temperature Sensor | Yes |
| Internal Class I Temperature Compensation | Yes |
| High-Temperature Signal Cable Length | 10 m |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CMP Series |
| Output Signal | ~10 mV per 1000 W/m² (typical) |
| Calibration | Individually calibrated with traceable certificate |
| Power Requirement | None (passive thermopile sensor) |
| Desiccant Life | ≥10 years (CMP3/CMP10 integrated) |
| Compliance | ISO 9060:2018 Class C (formerly Secondary Standard),符合WMO Guide to Meteorological Instruments and Methods of Observation |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP10 |
| Spectral Range | 285–2800 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time | < 5 s |
| Zero Offset A | < 7 W/m² |
| Zero Offset B | < 2 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | < 1 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Key | Brand: Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP11 |
| Spectral Range | 285–2800 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time (63%) | < 1.66 s |
| Zero Offset A | < 7 W/m² |
| Zero Offset B | < 2 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | < 1 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Output Signal | 0–20 mV (passive, no power required) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP21 |
| Spectral Range | 285–2800 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time | 5 s |
| Zero Offset A | < 7 W/m² |
| Zero Offset B | < 2 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−20 °C to +50 °C) | < 1 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Solar Irradiance | 4000 W/m² |
| Field of View | 180° |
| Output Signal | 0–20 mV (passive, no power required) |
| Key | Brand: Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP22 |
| Spectral Range | 200–3600 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time | 5 s |
| Zero Offset A | < 3 W/m² |
| Zero Offset B | < 1 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 5 W/m² |
| Temperature Dependence of Sensitivity (−20 °C to +50 °C) | < 0.5 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Output Signal | 0–20 mV (passive, no power required) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP3 |
| Spectral Range | 300–2800 nm |
| Output Signal | 0–55 mV (passive, no power required) |
| Sensitivity | 10 µV/W/m² (typical), 5–20 µV/W/m² (range) |
| Response Time (95%) | <18 s |
| Zero Offset A (thermal) | <15 W/m² |
| Zero Offset B (nighttime cooling) | <5 W/m² |
| Directional Error (up to 80° zenith, 1000 W/m² beam) | <20 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | <4 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 2000 W/m² |
| Field of View | 180° (2π steradian, hemispherical) |
| Calibration Compliance | ISO 9060:2018 Secondary Standard |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP6 |
| Spectral Range | 285–2800 nm |
| Sensitivity | 5–20 µV/W/m² |
| Response Time | 18 s |
| Zero Offset A | < 10 W/m² |
| Zero Offset B | < 4 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 20 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | < 2 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 2000 W/m² |
| Field of View | 180° |
| Output Signal | 0–20 mV (passive, no power required) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CUV5 |
| Spectral Range | 280–400 nm |
| Sensitivity | 300–500 µV/(W/m²) |
| Temperature Response | < −0.3 °C |
| Response Time | < 1 s |
| Non-linearity Error | < 1 % |
| Max Solar Irradiance | 400 W/m² |
| Operating Temperature | −40 to +80 °C |
| Directional Error (up to 80°, 1000 W/m² beam) | < 5 W/m² |
| Field of View | 180° |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | DustIQ |
| Power Supply | 12–24 V DC, 300 mA |
| Communication | RS-485 Modbus® RTU |
| IP Rating | IP67 |
| Cable Options | Standard 10 m UV-resistant cable (8-pin connector), optional 25 m or 50 m |
| Operating Temperature | –40 °C to +70 °C |
| Calibration | Factory-calibrated for glass surface soiling |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | LAS MkII |
| Aperture | 10 cm (100–1,000 m path) / 15 cm (250–4,500 m path) |
| Wavelength | 850 nm |
| Scintillation Bandwidth | 10⁻¹⁷–10⁻¹² m⁻²/³ |
| Power Supply | 12 VDC, 6 W (up to 54 W with heater enabled) |
| Dimensions | 400 × 300 × 240 mm (L×H×D) |
| Weight | 8.5 kg |
| Internal Processing | Cn², sensible heat flux (H), and derived turbulence parameters |
| Data Logging | Onboard non-volatile memory for multi-month storage |
| Interface | RS-232/422 digital, 0–2 V analog output |
| Software | EVATION® (real-time monitoring, post-processing, calibration support) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | METEON 2.0 |
| Storage Capacity | 3500 samples |
| Input Channels | 5 smart + 1 analog radiation sensors + 1 PV panel temperature sensor + 1 S0 kWh pulse input |
| Power Supply | Internal AA batteries (6) |
| Environmental Rating | Weather-resistant for outdoor deployment |
| Communication | USB, Bluetooth (METEON 2.0) |
| Compatibility | Modbus RTU, analog voltage/current (4–20 mA, 0–1 V, 0–5 V, 0–10 V) |
| Mounting Accessories | CVF4 ventilator, CMF1/CMF4 mounts, CMB1 universal mast bracket, CLF4 leveling fixture, AMPBOX signal conditioner, CM121B/C shading ring, anti-glare hood kit |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | NR Lite2 |
| Spectral Range | 200–100,000 nm |
| Sensitivity | 10 µV/W/m² |
| Response Time | < 20 s |
| Operating Temperature Range | -30 °C to +70 °C |
| Compliance | CE |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | RT1 |
| Sensor Type | Dual-channel digital pyranometer + backsheet temperature probe |
| Mounting | Corner-mount compatible with standard PV modules |
| Calibration Stability | ±2% uncertainty maintained for 5 years without recalibration |
| Output | RS-485 (Modbus RTU) or optional analog 4–20 mA |
| IP Rating | IP67 |
| Operating Temperature | −40 °C to +80 °C |
| Dimensions | 120 × 120 × 45 mm (L × W × H) |
| Weight | 320 g |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Model | SGR4 |
| Output Interface | Modbus® RS-485 & Enhanced Analog |
| Power Supply | 5–30 VDC |
| Field of View | 180° (Hemispherical) |
| Dome Material | Hard Carbon-Coated Silicon Dome |
| Thermal Stability | Dome-to-body coupling eliminates need for dome temperature measurement or shading |
| Desiccant Lifetime | ≥10 years |
| Warranty | 5 years |
| Optional Integration | CVF4 Ventilation Unit |
| Compliance | ISO 9060:2018 Class C (for pyrgeometers), WMO Guide to Instruments and Methods of Observation (CIMO) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SMP10 |
| Spectral Range | 285–2800 nm |
| Response Time (63%) | < 0.7 s |
| Response Time (95%) | < 2 s |
| Zero Offset A | < 7 W/m² |
| Zero Offset B | < 2 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−40 °C to +70 °C) | < 0.3 %/°C |
| Analog Output (-V version) | 0–1 V |
| Analog Output (-A version) | 4–20 mA |
| Digital Output | 2-wire RS-485 Modbus® |
| Operating Voltage | 5–30 VDC |
| Integrated Desiccant Cartridge Lifetime | ≥10 years (sealed operation) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SMP12 |
| Spectral Range (50% points) | 285–2750 nm |
| Response Time (63%) | < 0.15 s |
| Response Time (95%) | < 0.5 s |
| Zero-Offset (thermal offset, full range) | < 3 W/m² |
| Directional Response (1000 W/m² beam irradiance, up to 80° zenith angle) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | < 1 % |
| Temperature Dependence of Sensitivity (−40 °C to +70 °C) | < 2 % |
| Output Interface | 2-wire RS-485 Modbus® RTU |
| Supply Voltage | 10–30 VDC |
| Surge Protection | Level 2 on power input, Level 3 on RS-485 lines |
| Internal Desiccant Lifetime | ≥10 years (sealed enclosure) |
| Integrated Tilt Sensor & Humidity Monitor | Yes |
| Calibration Coefficient Stored in Memory | Yes |
| Digital Irradiance Output | Direct in W/m² |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SMP12 Pyranometer with Albedo Measurement Kit |
| Classification | ISO 9060:2018 Class A (Secondary Standard) |
| Spectral Range | 285–3000 nm |
| Response Time (95%) | < 1.5 s |
| Zero Offset (Thermal, 5 K/h) | ±1 W/m² |
| Non-linearity | < ±0.2 % (0–2000 W/m²) |
| Tilt Error | < ±1 % (0–90°, 1000 W/m²) |
| Operating Temperature | −40 °C to +80 °C |
| Output Signal | Analog (mV) and Digital (RS-485 / Modbus RTU) |
| Heating | Integrated dome heater (12–30 VDC, max 2.5 W) |
| Compliance | ISO 9060:2018 Class A, IEC 61724-1:2021, WMO Guide to Instruments (2022) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SMP22 |
| Spectral Range | 210–3600 nm |
| Response Time (63%) | < 0.5 s |
| Response Time (95%) | < 0.2 s |
| Zero Offset A | < 3 W/m² |
| Zero Offset B | < 1 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 5 W/m² |
| Temperature Dependence of Sensitivity (−20 °C to +50 °C) | < 0.3 % |
| Analog Output (-V) | 0–1 V |
| Analog Output (-A) | 4–20 mA |
| Digital Output | 2-wire RS-485 |
| Supply Voltage | 5–30 VDC |
| Integrated Desiccant Lifetime | ≥10 years |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SMP3 |
| Spectral Range | 300–2800 nm |
| Response Time (63%) | < 1.5 s |
| Response Time (95%) | < 12 s |
| Zero Offset A | < 15 W/m² |
| Zero Offset B | < 5 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | 20 W/m² |
| Temperature Dependence of Sensitivity (-20 °C to +50 °C) | < 2 % |
| Analog Output (-V version) | 0–1 V |
| Analog Output (-A version) | 4–20 mA |
| Digital Output | 2-wire RS-485 Modbus® RTU |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SMP6 |
| Spectral Range | 300–2800 nm |
| Response Time (63%) | < 1.5 s |
| Response Time (95%) | < 12 s |
| Zero Offset A | < 10 W/m² |
| Zero Offset B | < 4 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | ±15 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | < 2 % |
| Analog Output (-V version) | 0–1 V |
| Analog Output (-A version) | 4–20 mA |
| Digital Output | 2-wire RS-485 Modbus® RTU |
| Operating Voltage | 5–30 VDC |
| Integrated Desiccant Lifetime | ≥10 years |
| Compliance | ISO 9060:2018 Secondary Standard (Class A) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SOLYS2 |
| Tracking Accuracy | < 0.1° (passive) / < 0.02° (active with optional sun sensor) |
| Payload Capacity | 20 kg |
| Power Supply | 18–30 VDC or 90–264 VAC (50/60 Hz) |
| Operating Temperature | −20 to +50 °C (DC) / −40 to +50 °C (AC) |
| Enclosure Material | Cast aluminum with textured finish |
| Mounting | Integrated tripod base with leveling feet, azimuth adjustment, and bubble level |
| Communication Interface | Ethernet/Web interface |
| Drive Mechanism | Inverted-tooth belt drive |
| Power Consumption | 21 W (normal), 13 W (night), 100 W (with heater enabled, AC only) |
| Dimensions (tracker) | 50 × 34 × 38 cm |
| Weight (tracker) | 23 kg |
| Weight (tripod) | 5 kg |
| GPS Integration | Yes, auto-configures latitude, longitude, and UTC time |
| Software | Open-source firmware |
| Compliance | BSRN-compliant, designed for ISO 9072-1, ASTM G167, and IEC 61724-1 solar monitoring applications |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SP Lite2 |
| Measurement Principle | Silicon Photodiode-based Solar Irradiance Detection |
| Spectral Range | 400–1100 nm |
| Sensitivity | Approx. 10 µV per W/m² |
| Output Signal | Analog Voltage (0–10 mV or 0–5 V optional) |
| Operating Temperature | −40 °C to +80 °C |
| Response Time | < 1 s (95 %) |
| Zero Offset (Thermal) | < ±5 W/m² |
| Non-linearity | < ±1 % (0–1000 W/m²) |
| Tilt Error | < ±1 % (0–90° tilt, 1000 W/m²) |
| IP Rating | IP67 |
| Cable Length | 5 m standard (custom lengths available) |