- All
- Favorite
- Popular
- Most rated
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range | 0–10,000 ppb Na⁺ |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI direct PC connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Pathways | Up to six independent flow paths |
| Enclosure Rating | IP65-rated corrosion-resistant cabinet (H₂S/Cl₂ resistant, moisture-proof) |
| System Architecture | Physically segregated electronics and fluidic modules |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | AccuSeries |
| Measurement Principle | Potentiometric Titration (pH electrode endpoint detection) |
| Range Options | 0–1 g/L or 0–0.5 g/L (customizable per application) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Response Time | 8–12 minutes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA isolated channels |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI PC direct connection |
| Relay Outputs | configurable alarm and control relays |
| Sample Streams | up to six independent flow paths (modular architecture) |
| Enclosure Rating | NEMA 4X / IP66 equivalent (corrosion-resistant, H₂S/Cl₂ tolerant, humidity resistant) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | NIRSpec |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeris (Sentinel) |
| Pricing | Upon Request |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek |
| Measurement Principle | 12° Forward Light Scattering |
| Detection Range | 0–0.5 mg/L to 0–8000 mg/L (oil or water phase) |
| Optical Wavelength | 380–1100 nm |
| Repeatability | ±1% |
| Flow Cell Material | 316L Stainless Steel (Ti/PTFE optional) |
| Window Material | Sapphire (Borosilicate/PMMA optional) |
| Seal Material | FKM (FFKM/EPDM/Silicone optional) |
| Process Connection | DIN/ANSI Flange, NPT |
| Max. Process Pressure | PN16 / ANSI Class 150 |
| Max. Process Temperature | 140 °C |
| IP Rating | IP65 / NEMA 4X |
| ATEX Certification | Ex d IIC T6 (Zone 1 & Zone 2) |
| Cleaning | CIP-compatible, optional spray nozzle |
| Calibration Interval | Up to 24 months (application-dependent) |
| Power Supply | 90–260 VAC, 50–60 Hz (24 VAC/DC optional) |
| Analog Outputs | Up to 4 × 4–20 mA (independent) |
| Digital Interface | RS-232C / RS-485 (Modbus RTU) |
| Relay Outputs | 4 programmable (48 V / 2 A) |
| Data Logger | 8,000-point internal memory with backup restore |
| Environmental Operating Range | −10 °C to +50 °C |
| Power Consumption | ≤50 VA |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accuseries Copper Ion Concentration Analyzer |
| Measurement Principle | Bathocuproine (BCO) Colorimetric Method |
| Range | 0–10 ppm Cu²⁺ |
| Optical Technology | Dual-Wavelength Photometry |
| Probe Type | Fiber-Optic Immersion Probe |
| Display | High-Resolution LCD with Dedicated Function Keypad |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Automation | Fully Automated 24/7 Operation — Auto-Calibration, Auto-Cleaning, Reagent Auto-Fill |
| System Architecture | Physically Isolated Electronic Control Unit and Sample Analysis Module |
| Maximum Flow Paths | 6 Independent Channels |
| Corrosion Resistance | IP65-rated Enclosure |
| Diagnostic Capability | Real-Time Remote Self-Diagnosis with Alarms for Sample Absence, Low Reagent Level, Flow Failure, and Optical Path Obstruction |
| Compliance | Designed for Continuous Emission Monitoring (CEM) and Process Analytical Technology (PAT) Environments |
| Software Support | Web-based Configuration Interface with Audit Trail Logging (21 CFR Part 11 Ready) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek Ultrasonic |
| Measurement Principle | Ultrasonic Reflectance |
| Frequency Options | 5 MHz / 15 MHz |
| Enclosure Rating | NEMA 4X / IP65 |
| Max Process Pressure | 20 bar (customizable higher) |
| Max Process Temperature | 90°C (110°C with air cooling) |
| Sensor Material | 316 SS / PEEK |
| Sensor Length | ~300 mm (custom lengths available) |
| Cable Length | 100 m |
| Measurable Range | 0–100 ppm to 0–10,000 ppm (configurable |
| Output Units | ppm, mg/L, %, EBC, etc. |
| Accuracy | ±1% |
| Hazardous Area Certifications | Ex Zone I, Ex Zone II, Class 1 Div. 1 |
| Maintenance | No consumables |
| Installation | Retractable probe via 1" ball valve adapter |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Pricing | Upon Request |
| Display | High-resolution LCD with auxiliary programmable keypad |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC direct connection, relay outputs |
| Architecture | Modular analytical method design with field-configurable protocols |
| Diagnostics | Remote self-diagnosis with real-time alerts for sample absence, reagent level, system fault, and maintenance status |
| Automation | Fully automated 24/7 operation including auto-calibration, auto-zeroing, reagent dispensing, line flushing, and endpoint detection |
| System Isolation | Physically separated electronic control unit and wet chemistry module |
| Corrosion Resistance | IP66-rated enclosure with H₂S- and Cl₂-resistant materials |
| Electronics Design | Partitioned motherboard architecture—failure in flow control module does not interrupt main processor or DCS/PLC communication |
| Programmability | User-defined assay sequences (reagent addition order, pre-/post-measurement rinse cycles, auto-zero timing) |
| Analytical Method | On-line potentiometric titration using 0.01 N HCl standard solution with pH electrode endpoint detection |
| Range Options | 0–1 g/L or 0–0.5 g/L OH⁻ + CO₃²⁻ (chlor-alkali brine application) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Response Time | 3–12 minutes per analysis cycle |
| Operating Ambient Temperature | –20 °C to +60 °C |
| Dimensions (H×W×D) | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Requirement | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight isolated 4–20 mA channels |
| Digital Communication | Modbus RTU (RS232/RS485), Modbus TCP/IP |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Pricing | Upon Request |
| Measurement Principle | Potentiometric Titration with pH Endpoint Detection |
| Range Options | 0–1 g/L or 0–0.5 g/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Consumption | 100 W |
| Supply Voltage | 10–32 VDC or 90–240 VAC |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS-232/RS-485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Streams | Up to six independent flow paths (modular expansion) |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Compliance | Designed for hazardous area compatibility (Class I, Div 2 optional), supports GLP/GMP audit trails via software logging |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | AccuSeries1 |
| Measurement Principle | Potentiometric Acid-Base Titration with pH Endpoint Detection |
| Range Options | 0–20 mg/L or 0–500 mg/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 8–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA isolated channels |
| Communication Protocols | Modbus RTU/ASCII (RS232/RS485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Digital I/O | Relay outputs, status alarms |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Sample Stream Capacity | Up to six independent flow paths |
| System Architecture | Physically segregated electronics and wet chemistry modules |
| Compliance | Designed for continuous operation in hazardous area-adjacent industrial environments |
Show next