| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Metorex C100 |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Portability | Fixed-Installation |
| Analyte | Total Sulfur |
| Measurement Range | 0.5 ppm to 10 wt% |
| Analysis Mode | Real-Time Continuous Monitoring |
| Detection Limit | 0.5 ppm (S, in liquid hydrocarbons) |
| Accuracy | Compliant with ASTM D4294 and ASTM D7212 |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Hydrochloric Acid Concentration Analyzer |
| Price | Upon Request |
| Brand | Rubolab |
|---|---|
| Model | Smart Filtration Kit |
| Origin | Spain |
| Instrument Type | Online Monitoring System |
| Measured Parameters | Foam Characteristics, Particle Count (ISO/NAS Code), Demulsibility Indicator (via OilWear Sensor Platform), Optional Water Content (ppm) |
| Flow Control | Integrated Flow Meter & Regulator |
| Compliance | ISO 4406, ISO 11171, ASTM D892, ASTM D2711, ISO 6247 |
| Software | Rubolab OilWear™ Cloud Platform with Audit Trail & Exportable CSV/Excel Reports |
| Certifications | CE, RoHS, Designed for GLP/GMP Environments |
| Brand | Galvanic |
|---|---|
| Origin | Germany |
| Model | MONITEK TA6-FS |
| Instrument Type | Beer-Specific Turbidimeter |
| Application | Laboratory |
| Measurement Principle | Dual-Angle Light Scattering (12° Forward Scatter & 90° Side Scatter) |
| Measurement Range | 0–100 EBC (90°), 0–80 EBC (12°) |
| Sensitivity | 0.01 EBC |
| Repeatability | <1% (optical cell) |
| Measurement Time | ~17 s |
| Temperature Control | Up to 60 °C |
| Power Supply | 230 V AC (115 V AC optional) |
| Power Consumption | 60 VA |
| Interface | RS-232 |
| Dimensions (L×W×H) | 450 × 300 × 300 mm |
| Weight | 9 kg |
| Compliance | Designed for ISO 7027-compliant turbidity measurement in beverage matrices |
| Sample Vessel | Standard beer/beverage bottles (automatically rotated) |
| Automatic Compensation | Bottle surface irregularities, scratches, color, and background chromaticity |
| Brand | hte |
|---|---|
| Origin | Germany |
| Product Type | Lab-scale High-Throughput Sintering Reactor |
| Configuration | 4×36 or 2×25 Independent Sample Channels |
| Crucible Capacity | Customizable (e.g., 36 × 10 g) |
| Max Operating Temperature | 1050 °C |
| Atmosphere Control | Oxidizing (O₂), Reducing (e.g., Syngas), Inert (N₂/Ar) |
| Temperature Gradient Resolution | ±0.5 °C per Zone |
| Heating/Cooling Rate Control | Programmable (0.1–20 °C/min) |
| Gas Flow Precision | ±1% FS Mass Flow Control |
| Data Acquisition | Real-time T, P, gas composition, dwell time, ramp profiles |
| Compliance | GLP-ready architecture, FDA 21 CFR Part 11–compatible audit trail (via hteControl v5.2) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OH⁻ in NaOCl Solution |
| Price | Upon Request |
| Brand | HTE |
|---|---|
| Origin | Germany |
| Type | High-Throughput Co-Precipitation Reactor System for Battery Cathode Precursor Synthesis |
| Reactor Volume | 2 L or 10 L (customizable) |
| Operation Modes | Continuous, Batch with Concentrator, Heavy-Duty Batch with Concentrator |
| Max Operating Temperature | 70 °C at Ambient Pressure |
| Feed Types | Aqueous Metal Salt Solutions, Precipitants, Dopants, Dry Powders |
| Integrated Sensors | Real-time pH Monitoring, In-line Particle Size Measurement (e.g., laser diffraction), Automated Liquid Sampling |
| Software Suite | hteControl (experiment automation & data acquisition), Custom GUI, GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned R&D environments |
| Safety | Lab-in-Lab containment architecture with redundant safety sensors, 24/7 unattended operation certified |
| Material Output per Run | 1–5 kg of precursor (e.g., NMC, LFP, Prussian Blue analogues) |
| Scalability | Process parameters validated from lab-scale to pilot-scale with <±5% deviation in PSD and stoichiometry |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXC100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral & synthetic oils, coolants, cleaning fluids, cutting fluids |
| Data Interface | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 commercial lubricant models and ironographic particle morphology database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilCMS |
| Product Type | Portable Instrument |
| Detection Parameters | Tribological Wear Analysis |
| Oil Compatibility | Synthetic, Mineral, Organic Oils & Diesel (up to 3000 cSt) |
| Standards Compliance | ISO 4406, SAE AS4059, NAS 1638 |
| Software | Rubolab Oil Condition Monitoring Suite |
| Operating Modes | Offline (Bottle Sampling) & Online (High-Pressure Flow Cell) |
| Data Export | CSV, PDF |
| Calibration | Auto-calibration via embedded oil database (500+ lubricants), field-updatable |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S100 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Online Monitoring Sensor |
| Detection Parameter | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance Standards | ISO 4406:2017, NAS 1638 Class Code Calculation, ASTM D7647 (Image-Based Particle Analysis), GLP-Traceable Data Logging |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C100 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants |
| Particle Recognition Capability | ≥4 µm |
| Compliance Support | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral oil, synthetic oil, coolant, cleaning solution, cutting fluid |
| AI Engine | Trained on >500 commercial lubricant models and ferrographic particle morphology database |
| Data Output | Wired (Ethernet gateway) or Wireless (Wi-Fi/LoRaWAN) |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C120 |
| Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Fuel Oil, Mineral & Synthetic Oils, Coolants, Cutting Fluids, Cleaning Solutions |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 Commercial Lubricant Models & Lab-Validated Ferrographic Image Database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EX S100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic Oils, Lubricating Oils, Mineral & Synthetic Oils, Fuels, Coolants, Cutting Fluids, Aqueous Solutions |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Product Type | Online Instrument |
| Detection Parameters | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Mineral Oil, Synthetic Oil, Fuel Oil, Coolants, Cutting Fluids, Cleaning Solutions |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/4G) |
| AI Engine | Trained on >500 Commercial Lubricant Models & Iron Spectroscopy Image Database |
| Software | Cloud-Enabled Diagnostic Platform with Audit Trail & GLP/GMP-Ready Reporting |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXS120 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Particulate Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ATEX/IECEx Zone 1/21 Certified |
| Measurement Principle | AI-Enhanced Digital Image Analysis of In-Stream Oil Flow |
| Data Output | ISO 4406, NAS 1638, Wear Mode Classification (Fatigue, Cutting, Pitting, etc.) |
| Fluid Compatibility | Mineral Oils, Synthetic Lubricants, Hydraulic Fluids, Fuels, Coolants, Cleaning Solutions, and Aqueous Cutting Fluids |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S120 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/4G) |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Fuel Oil, Mineral Oil, Synthetic Oil, Coolants, Cleaning Solutions, Cutting Fluids |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilMoisture |
| Type | Online Instrument |
| Detection Target | Water Contamination in Lubricants |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Compliance Context | Designed for ISO 4406, ASTM D6304, and ISO 11171-compliant condition monitoring systems |
| Brand | Ankersmid |
|---|---|
| Origin | Germany |
| Model | OilHealth Probe |
| Type | Online Instrument |
| Application | Lubricating Oil Condition Monitoring |
| Core Technology | Multi-parameter Spectroscopic Analysis (FTIR + Electrochemical RULER + Viscosity Correlation) |
| Compliance Context | Designed for ISO 4406, ASTM D7883 (RULER), ASTM E2412 (FTIR), and OEM lubricant life extension protocols |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Monispec-AD |
| Price | Upon Request |
| Accuracy | ±0.1% FS |
| Linearity | ±0.1% FS |
| Repeatability | ±0.1% FS |
| Sensitivity | ±0.1% FS |
| Process Temperature Range | 0–140 °C (customizable up to 200 °C) |
| Process Pressure Range | 0–16 bar (customizable up to 30 bar) |
| Response Time | <1 s |
| Power Supply | 220 V AC or 24 V DC |
| Analog Output | 4–20 mA (loop-powered) |
| Measurement Ranges | Redness (0–8 Lov or 8–20 Lov), Yellowness (0–15 Lov or 15–80 Lov), Chlorophyll Concentration (0–1 ppm, typical range 0–200 ppb) |
| Process Connection | 10–100 mm (½″–4″ NPT or flanged) |