Empowering Scientific Discovery

Ruyaa Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelAET Extension Tube
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelAPS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelASP Gas Measurement Probe
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
ModelAccuseries-LPA Online Analyzer
TypeOnline Analyzer
Measurement PrinciplePyrazolone-based Colorimetric Method
Detection Range0–1 ppm CN⁻
Communication Interfaces4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs
Sample HandlingUp to 6 Independent Flow Paths
Enclosure RatingCorrosion-Resistant Design (H₂S/Cl₂ Resistant, Humidity-Protected)
ComplianceDesigned for Continuous Emission Monitoring Systems (CEMS) and Industrial Wastewater Compliance Applications
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Fluoride Ion Online Monitor
Instrument TypeFluoride Ion Analyzer
Measurement PrinciplePotentiometric Ion-Selective Electrode (ISE)
Range0–20 ppm
Accuracy±5% of reading or full scale
Resolution0.001 ppm
Repeatability±5% of reading or full scale
Cycle Time2 minutes
Sample Flow Rate50–900 mL/min
Sample Interface1/4" compression fitting
Sample Temperature5–70 °C
Max. Suspended Solids2% w/w, max. particle size 1.27 mm
Sample Pressure0–50 psig
Waste Outlet3/4" NPT male, open drain
Alarm OutputsUser-programmable digital outputs
Analog Output4–20 mA, fully configurable
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
Dimensions (W×H×D)610 × 640 × 330 mm
Weight~36 kg (fully assembled)
MountingWall-mounted with included hardware
CertificationsCE-compliant, designed to meet general requirements for industrial environmental monitoring installations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
ModelAccuseries LPA Online Analyzer
Instrument TypeOnline Chloride Analyzer
Measurement Range0–50 ppm
Detection Limit0.1 ppm
Response Time8 min
Accuracy±1% of reading
Operating Temperature Range−20 °C to +60 °C
Communication Interfaces4–20 mA, Modbus TCP/IP, RS232, RS458, USB, GUI PC Direct Connection, Relay Outputs
Sample StreamsUp to 6 independent flow paths
Analytical MethodPotentiometric Titration
Enclosure RatingIP65 (corrosion-resistant, H₂S/Cl₂ tolerant, moisture-proof)
Service LifeDesigned for continuous 24/7 operation with automated reagent management
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Chromium Ion Online Monitor
PriceUpon Request
Instrument TypeMulti-Ion Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Chromium Ion Online Monitor
PriceUpon Request
Instrument TypeMulti-Ion Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentine Phosphate Online Monitor
Instrument TypePhosphate (Orthophosphate) Analyzer
Accuracy±2% of reading or full scale
Resolution0.001 mg/L
Repeatability±2% of reading or full scale
Measurement Cycle5 minutes
Sample Flow Rate50–900 mL/min
Sample Interface1/4" compression fitting
Sample Temperature Range5–70 °C
Max. Suspended Solids2% w/w, max. particle size 1.27 mm
Sample Pressure Range0–345 kPa (0–50 psig)
Drain Outlet3/4" NPT male, atmospheric discharge
Alarm OutputsUser-programmable digital outputs
Analog Output4–20 mA, fully configurable
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
MountingWall-mounted with included hardware
Dimensions (W×H×D)387 × 406 × 210 mm
Weight~36 kg (fully configured)
CertificationsCE compliant
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Zinc Ion Online Monitor
PricingUpon Request
Instrument TypeMulti-Ion Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelACC Amide Compressor Cooler
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
ModelAccuseies Series
Measurement PrincipleColorimetric Titration with Dual-Wavelength Photometric Endpoint Detection (650 nm / 810 nm)
Range Options0–20 mg/L or 0–500 mg/L H₂SO₄
Accuracy±1% of full scale
Linearity±1% FS
Repeatability±1% RSD
Analysis Cycle Time15 min per sample
Sample Flow Rate200 mL/min
Max Sample Pressure<5 psi
Suspended Solids Limit<1,000 µm
Operating Temperature−20 °C to +60 °C
Dimensions1016 mm (H) × 406 mm (W) × 241 mm (D)
Weight45.3 kg
Power Supply24 VDC or 90–240 VAC
Enclosure RatingNEMA 4X (IP65)
Communication4–20 mA, Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, Ethernet
Digital I/O8 programmable dry/wet contacts (24 VDC)
Analog OutputsUp to 8 isolated 4–20 mA loops (self-powered)
Sample Interface1/4″ compression fitting
Environmental ResistanceH₂S- and Cl₂-resistant materials
System ArchitecturePhysically isolated electronic control unit and wet chemistry module
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Nitrate Online Monitor
Instrument TypeNitrate Ion (NO₃⁻) Analyzer
Measurement PrincipleIon-Selective Electrode (ISE)
Range Options0–10 ppm, 0–50 ppm, 0–100 ppm
Accuracy±5% of reading or full scale
Resolution0.001 ppm
Repeatability±5% of reading or full scale
Cycle Time2 minutes
Sample Flow Rate50–900 mL/min
Sample Inlet1/4″ compression fitting
Sample Temperature5–70 °C
Max Suspended Solids2% w/w, max particle size 1.27 mm (0.05″)
Sample Pressure0–50 psig
Waste Outlet3/4″ NPT male, atmospheric discharge
Alarm OutputsUser-programmable digital outputs
Analog Output4–20 mA, fully configurable
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
Dimensions (W×H×D)610 × 640 × 330 mm
Weight~36 kg (fully assembled)
MountingWall-mounted with included hardware
CertificationsCE compliant
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelAS3
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Total Manganese Online Monitor
Instrument TypeMulti-Ion Analyzer
Measurement PrincipleColorimetric Analysis (Formaldehyde Oxime Complexation)
RangeLow: 0–25 ppb, High: 0–200 ppb
Accuracy±2% of reading or full scale
Resolution0.001 ppb
Repeatability±2% of reading or full scale
Cycle Time10 minutes
Sample Flow Rate50–900 mL/min
Sample Inlet1/4" compression fitting
Sample Temperature5–70 °C
Suspended Solids≤2% w/w, max particle size 1.27 mm
Sample Pressure0–50 psig
Effluent Outlet3/4" NPT male, atmospheric discharge
Alarm OutputsUser-programmable
Analog Output4–20 mA, programmable
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
MountingWall-mounted with included hardware
Dimensions (W×H×D)387 mm × 406 mm × 210 mm
Weight~36 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Cu Ion Online Monitor
Instrument TypeMulti-Ion Analyzer
Measurement PrincipleColorimetric Spectrophotometry (Bathocuproine or Neocuproine Method)
Range0–10 ppm (Low), 0–20 ppm (High)
Accuracy±2% of reading or full scale
Resolution0.001 ppm
Repeatability±2% of reading or full scale
Cycle Time5–15 minutes
Sample Flow Rate50–900 mL/min
Sample Temperature5–70 °C
Max Suspended Solids2% w/w, particle size ≤1.27 mm
Sample Pressure0–50 psig
Sample Interface1/4" compression fitting
Waste Outlet3/4" NPT male, atmospheric discharge
Analog Output4–20 mA, user-configurable
Alarm OutputsProgrammable digital relays
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
MountingWall-mounted with integrated hardware
Dimensions (W×H×D)387 × 406 × 210 mm
Weight~36 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
ModelAccuseries LPA Online Analyzer
Instrument TypeOnline Sodium Ion Analyzer
Measurement Range0–10,000 ppb
Detection Limit0 ppb
Response Time10 min
Accuracy±1% of reading
Operating Temperature−20 to +60 °C
Communication Interfaces4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection
Sample StreamsUp to 6 modular flow paths
ComplianceDesigned for continuous operation in industrial water monitoring per ASTM D4192, ISO 10523, and USP <643> guidance for sodium in purified water systems
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelACP-ASR25
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOnline TOC Analyzer
Price RangeUSD 42,000 – 70,000
Instrument TypeOnline TOC Monitoring System
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodsUV/Persulfate, High-Temperature Combustion (680–900 °C), Ozone-Promoted Oxidation, Ultra-Pure UV Oxidation
Measurement Range0–50,000 ppm C
Accuracy±1% of reading
Resolution0.05 ppm C
Detection Limit0.05 ppm C
Repeatability±1% RSD
Sample ThroughputAs low as 3 minutes per analysis (configuration-dependent)
Dimensions (H×W×D)575 × 556 × 612 mm
Weight60 kg
Power Supply220 VAC, 10 A
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelALA Level Alarm Device
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
ModelAccuseries-LPA
Instrument TypeOnline Analyzer
Measurement PrincipleMolybdenum Blue Colorimetric Method
Range0–5000 ppb SiO₂ (as soluble silica)
Communication Interfaces4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs
Sample Flow PathsUp to 6 modular channels
Environmental RatingCorrosion-resistant housing
ComplianceDesigned for continuous operation in industrial water monitoring per ASTM D859, ISO 10530, and EPA Method 365.3 contexts
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentine Sulfide Ion Online Monitor
Instrument TypeMulti-Ion Analyzer
Measurement PrincipleColorimetric (with DMPD Oxalate Reagent)
Range0–5 ppm (customizable for higher ranges)
Accuracy±2% of reading or full scale
Resolution0.001 ppm
Repeatability±2% of reading or full scale
Measurement Wavelength650 nm
Reference Wavelength810 nm
Cycle Time15 minutes
Sample Flow Rate50–900 mL/min
Sample Volume per Analysis30 mL
Sample Temperature Range5–70 °C
Max. Suspended Solids2% w/v, max. particle size 1.27 mm
Sample Pressure0–50 psig
Sample Interface1/4" compression fitting
Effluent Port3/4" NPT male, atmospheric vent
Alarm OutputsUser-programmable digital outputs
Analog Output4–20 mA, fully configurable
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
MountingWall-mounted (hardware included)
Dimensions (W×H×D)387 × 406 × 210 mm
Weight~36 kg (fully configured)
CertificationsCE compliant
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAS3
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelAUF Universal Gas Filter
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0