Empowering Scientific Discovery

Ruyaa Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMonitek Turbidimeter
ConfigurationOnline Process Turbidimeter
Measurement Range0–8000 mg/L (as SiO₂)
Resolution0.1 mg/L
Operating Ambient Temperature−10 °C to +50 °C
Accuracy±1 % of reading
Optical Principle12° forward scatter detection
Wavelength Range390–900 nm
Repeatability±1 %
Process ConnectionDN25–DN125 (½″–5″)
Max Process PressurePN16 / ANSI Class 150
Max Process Temperature140 °C
Sensor Housing Material316L stainless steel (Ti, Mn-Co alloy optional)
Window MaterialSapphire or metal-backed glass
Gasket OptionsFKM (FFKM, EPDM, silicone available)
Enclosure RatingIP65 / NEMA 4X
CleaningOptional integrated spray nozzle
SterilizationCIP-compatible
Hazardous Area CertificationATEX Zone 1 or Zone 2
Power Supply90–260 VAC, 50–60 Hz (24 VAC/DC optional)
Power Consumption≤50 VA
Analog OutputsUp to 4 × 4–20 mA (isolated)
Digital InterfaceRS-232C / RS-485 Modbus RTU (optional)
Relay Outputs4 programmable relays (48 V / 2 A)
Digital Inputs4 × 5 V (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
TypeIn-line Process Turbidimeter
ModelMoniTurb-F
Measurement Range0–500 NTU
Resolution±2% of full scale
Accuracy±0.5% of full scale
Operating Ambient Temperature−10 °C to +60 °C
Process Temperatureup to 140 °C
Process Pressureup to 220 psi (15 bar) at ambient temperature
Wetted Materials316L stainless steel (1.4404) standard, customizable
Optical Path Lengthpipe-diameter-dependent
Cable Lengthup to 100 m
Enclosure RatingNEMA 4X / IP66
Hazardous Area OptionsClass I, Div. 1
Output InterfaceCompatible with Monitek® Messenger transmitter
Detection Principle12° forward scatter photometry
Optional ConfigurationsMoniTurb-S (90° side scatter), MoniTurb-FS (dual-angle scatter)
Calibration Interval12 months
Color CompensationYes
Optional Air/Water Jet Cleaning SystemAvailable
Process ConnectionsDIN, ANSI, SMS, NPT, APV, TH, Tri-Clamp
Units SupportedNTU, JTU, AU, EBC, ppm, g/L, % concentration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGALVANIC
OriginUSA
ModelMonitek-MoniTurb
TypeOnline Turbidimeter
Measurement Range0–500 NTU
Resolution0.1 NTU
Operating Temperature−10°C to 50°C
Accuracy±1%
Protection RatingIP65 / NEMA 4X
Hazardous Area CertificationATEX Ex d IIC/T6
Light SourceGas-filled lamp (380–1100 nm), ~2-year lifetime
Flow Cell MaterialStainless steel (optional Ti, PTFE)
Viewing WindowSapphire (optional borosilicate, acrylic)
SealsFKM (optional FFKM, EPDM, silicone)
Process ConnectionsDIN, ANSI, NPT
Scattering Angles12° forward scatter and 90° side scatter
Data Logging Capacity8,000 entries
CommunicationRS-232C / RS-485 (Modbus RTU)
Programmable UnitsNTU, JTU, AU, EBC, ppm, g/L, %TS, Hazen, ASTM, Saybolt
CleaningCIP-compatible, optional spray nozzle
Calibration/Maintenance IntervalUp to 24 months (application-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginImported
Manufacturer TypeAuthorized Distributor
Form FactorBenchtop/Laboratory
Measurement Ranges0–250 EBC (90° side scatter), 0–80 EBC (12° forward scatter)
Resolution0.01 EBC (sensitivity), 0.05 NTU (display resolution)
Operating Temperature0–30 °C
Accuracy<2% of reading
Repeatability<1% (with standardized cuvettes)
Power Supply230 V AC (115 V AC optional)
Power Consumption60 VA
Dimensions450 × 300 × 300 mm
Weight9 kg
Measurement Time~17 s
InterfaceRS-232
Cuvette RotationMotorized, 360° continuous
Automatic Surface Defect CompensationYes
Color Compensation AlgorithmEmbedded
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelAS3
PriceUpon Request
Operating PressureUp to 20 bar
Sensor Max Temp90°C (110°C with air cooling)
Hazardous Area OptionsATEX Zone 1 & Zone 2 / UL Class I Div 1
Sensor Length~300 mm (custom lengths available)
Measurement Range0–5 NTU to 0–5,000 NTU
Accuracy±1% of reading
Transducer Frequencies5 MHz and 15 MHz
Enclosure RatingNEMA 4X / IP65
Process IntegrationBall-valve-mounted insertion probe
CompatibilityAT3 interface
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0