| Brand | Dionex |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UVD-3000 |
| Price Range | USD 1,500–7,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Wavelength Range | 190–740 nm |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | 2100C |
| Cup Capacity | 6 (standard), 7 or 8 optional |
| Vessel Volume Range | 100–4000 mL |
| Temperature Control Accuracy | ±0.2 °C at 37 °C |
| Rotational Speed Range | 25–350 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | ±0.2 rpm |
| Bath Uniformity | <±0.1 °C |
| Drive System | High-torque permanent-magnet motor |
| Control Interface | LED display (14 mm height), RS-232, RS-485, printer port |
| Bath Construction | Monolithic acrylic casting |
| Shaft Tilt | <0.01° |
| Warranty | 6 months |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | 5100 Premiere |
| Usage Duration | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Functionally Verified |
| Compliance | Designed to meet USP <711>, <724>, and <1092> dissolution methodology requirements |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | 4300 |
| Pump Type | Dual High-Precision Positive-Displacement Syringe Pumps |
| Sample Collection Capacity | 0.1–20.0 mL per withdrawal |
| Maximum Vessels Supported | 12 |
| Sampling Interval Range | 5 min to 99 h |
| Number of Stored Protocols | Up to 7 |
| Media Recirculation & Replenishment | Yes |
| Compliance Features | Audit Trail Ready, User Access Control, Electronic Logbook |
| Warranty | 6 months post-installation |
| Operational Age | 4–5 years |
| Configuration | Standalone Dissolution Sampler with Integrated Controller and Dual-Pump Module |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | 6100 |
| Heating Rate | 2°C/min |
| Vessel Capacity | 500–1000 mL (up to 7 positions) |
| Rotational Speed Range | 25–350 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | ±0.2 rpm |
| Temperature Display Resolution | 0.01°C |
| Temperature Accuracy | ±0.25°C |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | USP <711>, <724>, FDA-recognized dry-block dissolution platform |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | GD-2 |
| Usage Duration | 3–4 years |
| Warranty | 6 months |
| Temperature Control Accuracy | ±0.5 °C |
| Basket Rack Configuration | Dual-bath, 12-tube (6 tubes per bath) |
| Drive Mechanism | Electromechanical vertical reciprocation |
| Stroke Length | 55 mm ± 1 mm |
| Reciprocating Frequency | 29–32 cycles/min |
| Water Bath Volume | ~1.5 L per bath |
| Compliance | ASTM D7892–14, USP <701>, Ph. Eur. 2.9.1, JP 17 <2.06> |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | Symphony 7100 |
| Heating Rate | 2°C/min |
| Vessel Capacity | 500–1000 mL |
| Speed Range | 30–300 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | ±0.5 rpm |
| Temperature Range | 20–99°C |
| Temperature Resolution | 0.01°C |
| Temperature Accuracy | ±0.25°C |
| Vessel Positions | Up to 8 |
| Concurrent Methods | Up to 3 (basket, paddle, mini-paddle) |
| Configuration | Dry-block heating, modular vessel units |
| Warranty | 6 months |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CTC HTS PAL |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months limited parts and labor |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 2D |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months Limited Coverage |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Sievers 900 |
| Warranty | 6 months |
| Usage Duration | 3–4 years |
| Calibration Stability | 12 months |
| Oxidation Method | UV/Persulfate |
| Detection Technology | Sievers Membrane Conductivity Detection |
| Measurement Range | 0.03 ppb – 50 ppm |
| Compliance | USP <643>, EP 2.2.44, ChP 0831, JP, IP, ASTM D5907, USEPA Methods 415.3 & 9060A |
| Software Compliance | 21 CFR Part 11-ready audit trail capability |
| Dimensions | 19.2 cm (W) × 50.8 cm (D) × 45.7 cm (H) |
| Interface | Full-color touchscreen GUI |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Gerstel MPS2 |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Automated Sample Introduction System |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | Gerstel MPS2 |
| Service Life | 3 years |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C18 Monomeric 120Å |
| Price Range | USD $150–$7,500 (FOB) |
| Product Category | Chromatography Column |
| Service Life | 4–5 years |
| Warranty | 6 months |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Protein & Peptide C18 |
| Price Range | USD 150–7,500 (FOB) |
| Product Category | Chromatography Column |
| Service Life | 4–5 years |
| Warranty | 6 months |
| Part Number | 218TP54 |
| Brand | Hanson Research |
|---|---|
| Origin | USA |
| Model | 72RL |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Standard USP Apparatus I (basket) and II (paddle) compliant |
| Regulatory Compliance | Designed to meet USP <711>, <724>, and FDA guidance for dissolution testing |
| Software Interface | RS-232/USB-compatible control and data acquisition |
| Vessel Capacity | 1000 mL standard |
| Temperature Control Range | 30–45 °C (±0.2 °C stability) |
| Rotation Speed Range | 25–250 rpm (digital control, ±1 rpm accuracy) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Hanson Research |
|---|---|
| Origin | USA |
| Model | SR8-Plus |
| Operating Age | 4 years |
| Warranty | 6 months |
| Compliance | USP Apparatus 1, 2, 5, 6 |
| System Configuration | 8-vessel |
| Bath Material | PETG acrylic water jacket |
| Control Architecture | Embedded microprocessor with 21 CFR Part 11-compliant firmware |
| Software Interface | Easy-Icon GUI with on-screen method editor, real-time graphing, and method storage (up to 25 protocols) |
| Thermal Design | Soft-Flo low-turbulence water circulation |
| Calibration Support | Built-in verification prompts and auto-alignment cup-shaft system |
| Brand | Hanson Research |
|---|---|
| Origin | USA |
| Model | Vision G2 Classic 6 |
| Temperature Range | 25–55 °C (±0.2 °C) |
| Rotational Speed Range | 25–250 rpm (±1 rpm) |
| Vessel Capacity | 11.4 L |
| Dimensions (D×W×H) | 585×394×673 mm |
| Power Supply | 220 V AC, 50–60 Hz, 65 W |
| Connectivity | RS232, USB, LAN |
| Software-Enabled Method Storage | Up to 100 protocols |
| Warranty | 6 months post-delivery |
| Operational Age | 3–4 years |
| Certification Status | Pre-tested and verified per USP <711> and ASTM D7832-14 compliance benchmarks |
| Brand | Hitachi |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Chromaster |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 Years |
| Warranty | 6 Months Limited |
| Brand | Hitachi |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | L-7000 |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–7 years |
| Warranty | 6 months |
| Instrument Type | HPLC System |
| Configuration | L-7100 Quaternary Pump, L-7250 Autosampler, L-7300 Column Oven, L-7450/L-7455 Diode Array Detector, D-7000 HPLC Management System |
| Brand | Hitachi |
|---|---|
| Origin | USA |
| Model | LaChrom Elite |
| Sample Compatibility | UV-Vis & Fluorescence Detection |
| Detector Types | L-2400 UV/VIS, L-2485 Fluorescence |
| Pump Type | L-2130 Quaternary High-Pressure Gradient Pump |
| Autosampler | L-2200 |
| Column Oven | L-2300 |
| System Organizer | Integrated DC Power Module |
| Software | Dual-language (English/Chinese), 21 CFR Part 11–compliant audit trail option |
| Warranty | 6 months |
| Operational Age | 4–7 years |
| Compliance | ASTM D5503, ISO 17025–compatible operation, GLP-ready configuration |
| Brand | Hitachi |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LaChrom Elite |
| Age | 4–5 Years |
| Warranty | 6 Months |
| Configuration | HPLC System (Pump L-2100, Autosampler L-2200, Column Oven L-2300, Diode Array Detector L-2450, System Organizer) |
| Condition | Refurbished & Fully Tested |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | LaChromUltra |
| Maximum Pressure | 60 MPa |
| Flow Rate Range | 0.001–5.000 mL/min |
| Gradient Capability | Dual-pump binary gradient system |
| Injection Volume | 0.1–20 µL |
| Column Oven Temperature Range | 1–65 °C (1 °C increment) |
| UV Detector Response Time | 0.01 s |
| Detection Wavelength Calibration | D₂ lamp + Hg lamp |
| Software Platform | Empower™ 2 / EZChrom Elite™ |
| Operating System | Windows® XP |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling |
| Brand | Hitachi |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Transgenomic |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty Period | 6 months |
| Included Modules | L-2130 Pump, L-2200U Autosampler, L-2310T Column Oven, L-2400 UV Detector, Chromatography Workstation |
| Condition | Refurbished & Functionally Verified |
| Compliance | Fully Tested per ASTM E2688-21 (Standard Practice for Verification of HPLC Systems) |
| Brand | Hitachi |
|---|---|
| Origin | USA |
| Model | Z-8200 |
| Instrument Type | Atomic Absorption Spectrophotometer |
| Optical System | Polarized Zeeman Background Correction |
| Detection Principle | Flame and Graphite Furnace AAS |
| Sample Introduction | Compatible with SSC-110 Autosampler |
| Warranty | 6 months |
| Operational Age | 4 years |
| Compliance | ASTM E1907, ISO 11171, USP <731>, GLP-ready configuration |
| Software | Hitachi AA Workstation v3.x (FDA 21 CFR Part 11 compliant audit trail enabled) |
| Included Accessories | SSC-110 autosampler, peristaltic pump, Epson LQ-570 dot-matrix printer, dedicated PC with pre-installed control software |
| Condition | Fully refurbished and performance-verified per Hitachi OEM calibration protocols |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HiSeq 2000 |
| Warranty Period | 6 months |
| Instrument Age | 3–4 years |
| Instrument Brand | Illumina |
| Product Category | NGS Platform |
| Configuration Status | Fully Tested & Refurbished |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HiSeq 2500 |
| Warranty Period | 6 months |
| Instrument Age | 3–4 years |
| Software Compatibility | Illumina BaseSpace, CASAVA v1.8.2+ |
| Run Modes | High-Throughput Mode (6-day run), Rapid Mode (27-hour run) |
| Output Capacity | Up to 1 TB (HT mode) or 120 GB (Rapid mode) per run |
| Read Length | SE >100 bp (HT), SE >150 bp (Rapid), PE >2×100 bp (HT), PE >2×150 bp (Rapid) |
| Input DNA Requirement | ≥0.1 µg |
| Raw Read Accuracy | ≥98.5% |
| Consensus Accuracy (3× coverage) | ≥99.99% |
| Homopolymer Resolution | ≥12 consecutive identical bases with ≥99% accuracy |
| Compliance | CE-IVD, FDA-listed device (for RUO use), GLP/GMP-ready workflow support |
| Brand | INNOTEG |
|---|---|
| Model | GC-5000C |
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Column Oven Temperature Range | Ambient + 5°C to 450°C |
| Max Ramp Rate | 150°C/min |
| Temperature Control Zones | 5 Standard + 4 Optional |
| Display | 9-inch Full-Color Touchscreen |
| Injector Configurations | Up to 3 Inlet Ports (simultaneous dual-injection capable) |
| Carrier Gas Control | Electronic Flow Control (EFC) |
| Compliance | Designed to meet ISO/IEC 17025 laboratory requirements for chromatographic analysis |
| Brand | INNOTEG |
|---|---|
| Model | HP-HG250 |
| Origin | Guangdong, China |
| Output Flow Rate | 250 mL/min |
| Hydrogen Purity | ≥99.9996% |
| Technology | Proton Exchange Membrane (PEM) Electrolysis |
| Water Feed | Deionized Water (Resistivity ≥1 MΩ·cm) |
| Maintenance | Maintenance-Free Drying System |
| Safety Features | Internal/External H₂ Leak Detection, Overpressure Protection, Overtemperature Protection, Real-Time Water Level Monitoring, Conductivity-Based Water Quality Monitoring |
| Compliance Context | Designed for GLP-compliant GC labs |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890 GC + AED-plus |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography & Elemental Detection System |
| Operational Age | 2–3 years |
| Warranty | 6 months |
| Brand | JASCO |
|---|---|
| Origin | Canada |
| Manufacturer | Bunkoukeiki (Japan) |
| Model | PU-980 + UV-1575 + AS-950-10 + CO-965 + DG-1580-53 + HG-1580-32 |
| Configuration | Quaternary gradient HPLC system with autosampler, column oven, vacuum degasser, and dynamic mixer |
| Pump Flow Range | 0.001–10.000 mL/min |
| Detector Wavelength Range | 190–800 nm |
| Autosampler Capacity | 108 × 1.5 mL vials (standard) |
| Column Oven Temperature Range | Ambient +5°C to 85°C |
| Degasser Type | Vacuum membrane degasser (4-channel) |
| Mixer Volume | 250 µL |
| System Age | 5–7 years |
| Refurbishment Standard | Fully tested, calibrated, and validated per ISO/IEC 17025-aligned procedures |
| Warranty | 6 months limited parts and labor |
| Brand | Jasco (Bunkoukeiki) |
|---|---|
| Origin | Japan |
| Model | LC-2000Plus |
| Configuration | PU-2089Plus quaternary low-pressure gradient pump, AS-2059Plus autosampler, CO-2060Plus column oven, FP-2020Plus fluorescence detector, DG-2080-54 4-channel degasser, C-Net II / ADC chromatography data system |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned internal protocol |
| Software | C-Net II v3.x with ADC acquisition module |