| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC with NPD & FID |
| Detector Types | Nitrogen-Phosphorus Detector (NPD), Flame Ionization Detector (FID) |
| Instrument Category | Gas Chromatograph (GC) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original PerkinElmer factory specifications for GC operation and detector performance |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem TCD |
| Instrument Category | Gas Chromatograph |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Automation | Integrated Autosampler |
| Condition | Refurbished & Fully Tested |
| Operational Age | >7 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D1945, ISO 6974, and USP <621> gas chromatography requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC |
| Detector Configuration | Dual FID |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 15528, and USP <621> for hydrocarbon and volatile organic compound analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Model 40 Headspace |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PID-ELCD |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty Period | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem XL |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Configuration | Refurbished, Fully Tested |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 6416, and USP <621> chromatographic system suitability requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Autosystem XL |
| Instrument Type | Gas Chromatograph |
| Year of Manufacture | ≥7 years old |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 10301, and USP <621> chromatographic system suitability requirements |
| Software Compatibility | Native support for TurboChrome v5.x and optional migration to Chromeleon CDS (via hardware interface adapter) |
| Detector Options Supported | FID, TCD, ECD, NPD, FPD, PID |
| Injector Types Supported | Split/splitless capillary inlet, programmable temperature vaporizing (PTV) inlet, cold-on-column (COC) inlet, packed column inlet |
| Automation | Compatible with PerkinElmer AS-100/AS-200 series autosamplers |
| Operating Environment | 15–35 °C, 20–80% RH non-condensing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 500 |
| Instrument Type | Gas Chromatograph |
| Age | 4 years |
| Warranty | 6 months |
| Detector Options | FID, ECD, TCD, NPD, FPD, PID |
| Injector Types | Capillary Split/Splitless, PTV, Cold On-Column, Packed Column |
| Automation | TurboMatrix Headspace Autosampler, TurboMatrix Thermal Desorber, Standard Liquid Autosampler |
| Software | TotalChrom™ or Chromeleon™ (version-dependent) |
| Operating Environment | Lab-grade controlled temperature and humidity |
| Compliance | Designed to support ASTM D3612, USP <467>, ISO 11843, EPA Methods 502.2, 524.2, 8240, 8260, and GLP/GMP data integrity requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | Clarus 500 |
| Instrument Type | Gas Chromatograph (GC) |
| Detector Configuration | FID & ECD |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 10301, and USP <621> for GC method execution |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 500 GC/MS |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Detection Principle | Electron Ionization (EI) Mass Spectrometry coupled with Capillary Gas Chromatography |
| Software | TurboMass v8.x |
| Compliance | Designed to meet ASTM D3699, EPA Method 8270D, and ISO 17025 laboratory requirements for trace organic analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | Clarus 500 FID |
| Product Category | Gas Chromatograph |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Configuration | Includes FID and autosampler |
| Condition | Refurbished & Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 10301, and USP <621> for hydrocarbon analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 600/600T |
| Mass Range | 1–1200 u |
| Scan Rate | Up to 60 scans/sec |
| Detection Limit | <1 pg octafluoronaphthalene (OFN), S/N ≥ 180:1 RMS |
| Column Oven | Fast heating and cooling capability |
| Warranty | 6 months |
| Operational Age | 4 years |
| Instrument Type | Quadrupole GC/MS |
| Compliance | Designed for ASTM, ISO 17025, USP <621>, and GLP/GMP-aligned workflows |
| Software | TurboMass™ v8.x with 21 CFR Part 11-compliant audit trail and electronic signature support |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 680/600T |
| Mass Range | 1–1200 u |
| Scan Speed | Up to 60 scans/sec |
| Detection Limit | <1 pg octafluoronaphthalene (OFN), S/N ≥ 180:1 RMS |
| Column Oven | Rapid heating and cooling capability |
| Warranty | 6 months |
| Operational Age | 4 years |
| Instrument Type | Quadrupole GC/MS |
| Compliance | Designed for ASTM, ISO 17025, USP <621>, and FDA 21 CFR Part 11–ready software environments |
| Software | TurboMass™ v8.x with GLP/GMP audit trail support |
| Included Components | GC unit (Clarus 680), MS detector (Clarus 600T), autosampler, vacuum pump, dedicated workstation PC, GC/MS interface hardware, and consumables kit |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Elan 5000 |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 7 years |
| Refurbishment Age | 3–4 years |
| Warranty | 6 months |
| Condition | Fully Tested & Certified by SpectraLab Scientific |
| Compliance | Meets original OEM performance specifications for routine trace elemental analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Elan 6100 |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Included Accessories | AS-series autosampler, Gilson Minipuls 3 peristaltic pump, Neslab CFT-75 chiller unit |
| Compliance Status | Fully refurbished and functionally validated per ISO/IEC 17025-aligned protocols |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ELAN DRC II |
| Technique | ICP-MS |
| Resolution | 0.3–3 amu (AutoRes, online adjustable) |
| Linear Dynamic Range | 9 orders of magnitude |
| DRC Reaction Gases | H₂, He, CH₃, NH₃, O₂, N₂O, CO₂ |
| Interference Reduction Capability | >7 orders of magnitude |
| Mass Resolving Power | >150,000 (chemical resolution) |
| Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag) | <0.08% RSD |
| Vacuum System | Dual mechanical pumps + dual turbomolecular pumps (total pumping speed >380 L/min) |
| Warm-up Time | ≤10 min |
| Sample Introduction | GemClean® cross-flow nebulizer + Ryton® Scott-type double-pass spray chamber |
| Cone Design | Largest orifice in industry for high-salt matrix robustness |
| RF Generator | Built-in 40.68 MHz self-tuned solid-state generator |
| Key Technologies | PlasmaLok™ interface, AutoLens™ lens bias optimization, SimulScan™ synchronous scanning, EasyGlide™ torch auto-positioning |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ELAN DRC-e |
| Instrument Type | ICP-MS |
| Year of Manufacture | ~2005–2010 (typical for DRC-e production cycle) |
| Operational Age | ≤3 years (post-refurbishment) |
| Resolution Range | 0.3–3 amu (electronically tunable in real time) |
| Linear Dynamic Range | 9 orders of magnitude |
| Interference Reduction Factor | >10⁷ for polyatomic interferences (e.g., ⁴⁰Ar¹⁶O⁺ on ⁵⁶Fe⁺, ⁴⁰Ar⁴⁰Ca⁺ on ⁸⁰Se⁺) |
| Warranty | 6 months limited hardware warranty |
| Compliance | Designed to meet ASTM D5673, ISO/IEC 17025 method validation requirements, and supports GLP/GMP data integrity practices when paired with compliant software |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Flexar FX-20 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 18,000 psi |
| Detection Speed | 100 pts/sec (UV/Vis), 200 Hz (PDA) |
| Column Oven Temperature Range | 5–90 °C (Peltier), ±0.2 °C stability |
| Autosampler Injection Volume | 1–100 µL |
| Injection Cycle Time | ≤8 s |
| Solvent Channels | 3 or 5 with integrated degasser |
| Software Platform | Chromera CDS or TotalChrom CDS |
| Regulatory Compliance | 21 CFR Part 11 ready (TotalChrom), GLP/GMP-supporting audit trail and user access control |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Flexar HPLC |
| Configuration | Quaternary Pump, Autosampler, Column Oven with Cooling, UV Detector, Solvent Manager, PC with Chromera Software |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned protocols |
| Certifications | Factory-calibrated |
| Software | Chromera CDS v2.5+ (21 CFR Part 11 compliant audit trail enabled) |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flexar |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Detector Type | UV/Vis |
| Pump Configuration | Quaternary Solvent Manager |
| Power Supply | 50/60 Hz |
| Included Modules | Flexar Solvent Manager (5-Channel, N₂ Degasser, P/N N2600580) |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | FLEXAR™ |
| Product Category | Fluorescence Detector (not Mass Spectrometer) |
| Usage Duration | 3–4 years |
| Warranty | 1 year |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GeneAmp PCR System 9700 |
| Age | 4 years |
| Warranty | 6 months |
| Sample Block | Replaceable 96-well 0.2 mL block |
| Display | Blue LCD graphical display with real-time thermal profile visualization |
| Method Storage | Up to 100 user-defined protocols |
| Compliance | Designed to meet ISO/IEC 17025 laboratory requirements for thermal cycling validation |
| Software Interface | Native ABI-style keypad navigation with soft-touch buttons |
| Certification Status | Fully refurbished and functionally verified per ASTM E2873-22 (Standard Guide for Verification of Thermal Cyclers) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 12 |
| Instrument Type | UV-Visible Spectrophotometer |
| Optical Range | 190–1100 nm |
| Typical Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system with standard cuvette holder, quartz cuvettes, and control software |
| Compliance | Designed to meet ASTM E275, ISO 6223, and USP <857> photometric accuracy requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 2 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system, fully tested and calibrated |
| Compliance | Meets original factory specifications for optical performance and photometric accuracy |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 20 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully Tested & Certified Refurbished System |
| Compliance | Meets Original OEM Performance Specifications |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 25 |
| Wavelength Range | 190–1100 nm |
| Slit Width | Fixed 1 nm |
| Detector Type | Solid-State Detector (SCD) |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E275, ISO 6425, USP <857> |
| Software Platform | UV WinLab v6.x |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Lambda 25 UV/Vis |
| Spectral Range | 190–1100 nm |
| Optical Resolution | 1 nm (fixed slit) |
| Photometric Accuracy | ±0.005 A (at 0.5 A, NIST-traceable standards) |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Scan Speed | Up to 2400 nm/min |
| Detector | Silicon photodiode |
| Data Interface | RS-232 or USB (via optional adapter) |
| Software Compatibility | WinUV v4.x (legacy), third-party spectral acquisition via ASCII export |
| Warranty | 6 months limited parts and labor |
| Service History | Refurbished and fully performance-verified per ASTM E275 and ISO 17025-aligned protocols |
| Operational Age | 4–5 years |
| Compliance | Meets requirements for routine QC in pharmaceutical, environmental, and academic laboratories under GLP and ISO/IEC 17025 frameworks |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 2S |
| Product Category | Spectrophotometer |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully Tested & Certified Refurbished System |
| Compliance | Meets ASTM E275, ISO 9001 Calibration Traceability Standards |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 35 |
| Wavelength Range | 190–1100 nm |
| Slit Width Options | 0.5, 1, 2, 4 nm |
| Detector Type | Solid-State Detector (SCD) |
| Typical Service Life | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E275, ISO 6233, USP <857> |
| Application Domain | UV-Vis Spectroscopy, Quantitative & Qualitative Analysis, Method Validation, QC/QA in Pharma, Chemical & Academic Labs |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 40 |
| Instrument Type | UV-Visible Spectrophotometer |
| Optical Range | 190–1100 nm |
| Typical Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system with standard cuvette holder, quartz cuvettes, and control software |
| Compliance | Meets ASTM E275, ISO 6223, and USP <857> for photometric accuracy verification |