| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UV-1601 / UV-1600 |
| Spectral Bandwidth Options | 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm |
| Detector | Imported Silicon Photodiode |
| Light Sources | Socket-type Imported Deuterium Lamp & Tungsten Halogen Lamp |
| Wavelength Range | 190–1100 nm (typical for class) |
| Power Supply | AC 220 V / 50 Hz or 110 V / 60 Hz |
| Power Consumption | 180 W |
| Dimensions (W×D×H) | 630 × 470 × 210 mm |
| Net Weight | 26 kg |
| Warranty | 6 months limited warranty |
| Condition | Refurbished — 90% operational life remaining, fully functional, factory-tested |
| Compliance | Designed to meet general requirements of ISO/IEC 17025 supporting laboratories |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WFX-120B |
| Price | USD 4,200 (FOB Beijing) |
| Product Category | Optical Spectroscopy |
| Operational Age | 6–8 years |
| Warranty | 6 months limited parts & labor |
| Instrument Type | Flame AAS |
| Flame Temperature Range | 2300–2950 °C (adjustable) |
| Wavelength Range | 190–900 nm |
| Grating Density | 1800 lines/mm |
| Focal Length | 277 mm |
| Blazed Wavelength | 250 nm |
| Spectral Bandwidth | Multi-step automatic switching |
| Atomizer | 10 cm single-slit titanium burner |
| Nebulizer | Metal-sheathed high-efficiency glass nebulizer |
| Sample Uptake Rate | 6–7 mL/min |
| Background Correction | D₂-lamp (≥30× at 1 Abs) and Self-Reversal (≥30× at 1.8 Abs) |
| Detector | Wide-spectral-range photomultiplier tube (PMT) |
| Lamp System | 6-position auto-switching turret (2 positions compatible with high-performance hollow cathode lamps) |
| Lamp Current Drive | 400 Hz square-wave pulse |
| Software Platform | Windows 98/Me/XP native BRAIC application suite |
| Data Output | RS-232 interface |
| Dimensions (W×D×H) | 1020 × 490 × 540 mm |
| Weight | 80 kg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-130B |
| Wavelength Range | 190–900 nm |
| Light Source | 4-lamp turret auto-switching (2 positions compatible with high-performance hollow cathode lamps) |
| Lamp Current Control | Wide-pulse 0–25 mA / Narrow-pulse 0–10 mA |
| Monochromator | Czerny-Turner type, 1800 lines/mm grating, 277 mm focal length, 250 nm blaze wavelength |
| Spectral Bandwidth | Multi-step automatic switching |
| Atomizer | 10 cm single-slit titanium burner, corrosion-resistant all-plastic nebulizer chamber, metal-sheathed high-efficiency glass nebulizer (6–7 mL/min uptake) |
| Background Correction | Deuterium lamp (≥30× correction at 1 Abs) and self-reversal (≥30× at 1.8 Abs) |
| Detector | High-sensitivity, broad-spectrum photomultiplier tube |
| Data System | Windows 98/Me/XP-compatible BRAIC software with automated calibration (standard addition, curve fitting), multi-element sequential analysis, statistical reporting (mean, SD, RSD), RS-232 interface |
| Dimensions & Weight | 1020 × 490 × 540 mm, 80 kg |
| Flame Temperature Range | 2300–2950 °C (oxygen-enriched air-acetylene system) |
| Operational Age | ≥7 years |
| Warranty | 6 months |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 450 GC |
| Product Category | Chromatography |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | 450-GC |
| Instrument Type | Gas Chromatograph |
| Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Includes GC mainframe, optional autosampler, chromatography workstation, and essential tubing/cabling |
| Compliance | Fully tested and validated per ISO/IEC 17025-aligned internal protocols |
| Software | STAR Chromatography Data System (CDS), GLP-compliant audit trail enabled |
| Temperature Range | Oven programmable from ambient +4 °C to 450 °C (7 ramps, 8 plateaus) |
| Detector Compatibility | FID, TCD, ECD, TSD (NPD), PFPD, ion trap MS, quadrupole MS, and MS/MS |
| Inlet Options | Up to three simultaneous inlets including 1079 PTV (5 injection modes), 1177 split/splitless, and 1041 packed column |
| Carrier Gas Control | Precision electronic pressure/flow control (EPC) with gas-saving mode |
| Column Oven | Rapid heating/cooling kinetics for cycle time reduction |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | 450-GC+300MS |
| Configuration | GC-MS/MS (Triple Quadrupole) |
| Instrument Condition | Refurbished & Fully Qualified Used System |
| Regulatory Compliance | Designed to meet ASTM D5845, EPA Method 8270/8260, and ISO 17025 laboratory requirements |
| Software Platform | Bruker Compass DataAnalysis 5.4+ with QuantAnalysis and TargetScreener modules |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 456 |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty Period | 6 months |
| Included Automation | CP-8400 Autosampler |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Avance 700 |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Product Category | Spectroscopy |
| Operational Age | 3–4 Years |
| Warranty | 6 Months Limited |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | GC456-SCION TQ |
| Configuration | Used, Refurbished & Fully Qualified Triple Quadrupole GC-MS/MS System |
| Compliance | Meets ASTM D5845, EPA Method 8270/8260, and ISO 17025-aligned operational readiness standards |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | o-Advance |
| Pressure Rating | 10,000 PSI |
| Flow Range | 1 nL/min – 50 µL/min |
| Flow Precision | <0.25% RSD at ≤8 µL/min |
| Detector Interface | USB-controlled modular architecture |
| System Type | Nanoflow/Capillary UHPLC |
| Usage Duration | 3–4 years |
| Warranty | 6 months |
| Compliance | Pre-calibrated for LC-MS coupling |
| Software Compatibility | HyStar & Compass CDS |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | SCION 456-GC |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | GC system with optional autosampler, Compass CDS software, and essential gas lines/tubing |
| Compliance | Fully tested and validated per ISO/IEC 17025-aligned internal protocols |
| Regulatory Readiness | Compatible with FDA 21 CFR Part 11-compliant data integrity workflows when deployed with validated software configuration |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sequenom MassARRAY |
| Product Category | MALDI-TOF Mass Spectrometer |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | Sequenom MassARRAY |
| Configuration | Includes MassARRAY Analyzer 4, SpectroCHIP Reader, Integrated Workstation PC, and Full Software Suite |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | COMBIPAL |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Product Category | Chromatography |
| Service Life | 2–3 Years |
| Warranty | 6 Months |
| Compatibility | GC & GC/MS Platforms |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cohesive/CTC Twin HTS PAL |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography Instrumentation |
| Operational Age | 5–7 years |
| Warranty | 6 months limited parts and labor |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | COMBI-xt PAL |
| Age | 3–4 years |
| Warranty | 6 months |
| Included Modules | Liquid Sampling, Headspace (HS), SPME, ITEX-2, SPDE, Thermal Desorption, FlowCell, Dilutor |
| Compatibility | Universal GC & GC-MS platforms (Agilent, Thermo, Shimadzu, PerkinElmer, etc.) |
| Positioning Accuracy | ±0.1 mm (XYZ linear motion) |
| Structural Design | Overhead gantry architecture |
| Regulatory Readiness | Compliant with GLP/GMP workflows |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTC-PAL |
| Condition | Refurbished (7+ Years Operational History) |
| Warranty | 6 Months |
| Product Category | LC-MS Front-End Automation System |
| Bench Footprint | ≤50 cm |
| Microplate Capacity | Up to 24 Plates |
| Sample Temperature Control | Yes |
| Compatibility | Universal Interface for Major LC-MS Platforms (Agilent, Thermo Fisher, Waters, Shimadzu) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTC-Pal |
| Price | USD 6,000 |
| Product Category | Other Analytical Automation Equipment |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Instrument Model | HTC-Pal |
| Service Life | 3 Years |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTS-Pal |
| Age | 3–4 Years |
| Warranty | 6 Months |
| Control Mechanism | XYZ Stepper-Motor-Driven Positioning (0.10 mm/step) |
| Compliance | IQ/OQ Documentation Available |
| Configuration | LC & LC-MS Compatible |
| Refurbishment Standard | SpectraLab Scientific Certified |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTS |
| Age | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DX-120 |
| Instrument Age | >10 Years |
| Pump Flow Rate | 0.5–4.0 mL/min |
| Max Pump Pressure | 4000 psi (27.5 MPa) |
| Conductivity Detector Range | 0–1700 µS |
| Temperature Compensation | 1.5–1.9%/°C |
| Detector Cell Volume | 1.25 µL |
| Operating Temperature | 10–40°C |
| Dimensions (H×W×L) | 60 × 30 × 40 cm |
| Weight | ~40 kg |
| Power Input | 100 V/50 Hz, 115 V/60 Hz, or 220–240 V/50 Hz |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1000 |
| Pump Flow Range | 0.00–5.00 mL/min (0.01 mL/min increments) |
| Maximum Pressure | 5000 psi |
| Conductivity Detector Range | 0–15,000 µS |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Included Components | ICS-1000 Console, AS40 Autosampler |
| Compliance | Fully Tested & Certified per SpectraLab Scientific Pre-Delivery Protocol |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1100 |
| Instrument Type | Ion Chromatograph |
| Usage Duration | 4 years |
| Warranty | 6 months |
| Compliance | ASTM D4327, ISO 14911, USP <645>, EPA Methods 300.0/300.1 |
| Software | Chromeleon® 7.2.10 or later |
| Detection Principle | Suppressed Conductivity Detection with Electrolytic Regeneration |
| Pump Material | PEEK (pH 0–14 compatible) |
| Max Pressure | 35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min |
| Conductivity Detector Resolution | 0.00238 µS/cm |
| Data Interface | USB 2.0 |
| Column Oven Temp Range | 30–60 °C ±0.5 °C |
| Suppressor Types Supported | SRS®, AES®, MMS™ |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1500 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Column Heater Temp Range | Ambient +5 °C to 60 °C |
| Control Interface | Front-panel keypad and Chromeleon™ software |
| Compliance | ASTM D4327, ISO 10304-1, USP <645>, EPA Methods 300.0 & 317.1 |
| Software | Chromeleon 7.2.10 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-2000 |
| Pump Type | Dual-piston reciprocating, microprocessor-controlled fixed-stroke, variable-speed |
| Flow Rate Range | 0.05–5.0 mL/min (0.01 mL/min increments) |
| Max Pressure | 35 MPa (5000 psi) |
| Pressure Ripple | <1.0% |
| Flow Accuracy | ±0.1% |
| Flow Precision | <0.1% |
| Column Oven Temp Range | Ambient +5°C to 60°C (±1°C stability, ±2°C accuracy at 40°C) |
| EG Concentration Range | 0.1–100 mM |
| EG Flow Range | 0.1–3.0 mL/min |
| EG Max Pressure | 21 MPa (3000 psi) |
| Conductivity Detector | Digital signal processing, linear range 1% at 1 mS, resolution 0.00238 nS, detection range 0–15000 µS, cell volume <1 µL, temperature control range ambient +7°C to 55°C (stability ≤0.01°C) |
| Suppressor Power Supply | AESR (0–150 mA, 1 mA steps), SRS (0–500 mA, 1 mA steps) |
| Dimensions (H×W×D) | 56.1 × 22.4 × 53.3 cm |
| Weight | 24.5 kg |
| Power | 100–240 V AC, 47–63 Hz |
| Operating Environment | 4–40°C, 5–95% RH (non-condensing) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICS-2000 |
| Price | USD 17,800 (FOB) |
| Product Category | Chromatography |
| Usage Duration | 4–5 years |
| Warranty | 6 months |
| Instrument Model | ICS-2000 |
| Total Service Life | 6–8 years |
| Pump Type | Dual-piston reciprocating pump |
| Flow Rate Range | 0.05–5.0 mL/min (0.01 mL/min increments) |
| Max Pressure | 35 MPa (5000 psi) |
| Pressure Ripple | <1.0% |
| Conductivity Detector Cell Volume | <1 µL |
| Temperature Control Range (Column Heater) | Ambient +5°C to 60°C |
| Temp Stability | ±1°C |
| Electrolytic Eluent Generator Range | 0.1–100 mM |
| Suppressor Power Supply | AESR: 0–150 mA (1 mA step) |
| SRS | 0–500 mA (1 mA step) |
| Dimensions (H×W×D) | 56.1 × 22.4 × 53.3 cm |
| Weight | 24.5 kg |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-3000 |
| Pump Configuration | Single or Dual Pump (SP/DP) |
| Flow Rate Range | 0.001–10.0 mL/min |
| Max Operating Pressure | 35 MPa (5000 psi) |
| Detector Modules | Conductivity Detector (0–15,000 µS), Electrochemical Detector (Ag, Pt, Au, GC electrodes) |
| Eluent Generator | Single- or Dual-Channel EG with Programmable High-Voltage Power Supply & High-Pressure Degassing |
| Eluent Organizer | Dual EO slots, each supporting up to four 1-L/2-L or two 4-L bottles with simultaneous 4-channel pressurization |
| Auto-sampler | Supports Concentrated, Simultaneous, Sequential, and Sequential-Concentrated Injection Modes |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully tested per SpectraLab Scientific QC protocol |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-5000 |
| Configuration Options | Dual-Pump (DP) or Single-Pump (SP) |
| Detector Modules | Conductivity, Pulsed Amperometric (PAD), Variable Wavelength UV (VWD), CAD, Fluorescence, MS-compatible |
| Autosampler | AS-AP |
| Operating Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully serviceable per Thermo Fisher technical standards |
| Sample Introduction | Capillary, microbore, and standard-bore compatibility |
| Eluent Generation | RFIC™ EGC-KOH/EGC-MSA cartridges with 18-month cartridge life |
| Water Consumption | ≤5.25 L/year in capillary mode |
| Ready-State Functionality | Enabled for rapid system startup |
| Multi-dimensional Capability | IC×IC (2D-IC), IC-MS, IC-MS/MS, IC-ICP-MS support |
| Regulatory Readiness | Audit-ready configuration for GLP/GMP environments with optional 21 CFR Part 11-compliant software modules |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 Nano |
| Configuration | LPG-3400M quaternary low-pressure micro-gradient pump, VWD-3400 variable-wavelength UV detector, FLM-3200 NANO flow manager (2P-10P & 2P-6P), WPS-3000T autosampler, SRD-3600 solvent rack with 6-channel degasser |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocols |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 |
| Configuration | LPG-3400A Quaternary Pump, WPS-3000TSL Analytical Autosampler, TCC-3000SD Column Compartment, VWD-3400RS Multi-Wavelength UV-Vis Detector, SR-3000 Solvent Rack with Integrated Degasser |
| Flow Rate Range | 0.2–10.000 mL/min |
| Pressure Range | 0.1–50 MPa |
| Gradient Delay Volume | 690 µL (360 µL optional) |
| Injection Volume | 1–90 µL (0.1–100 µL programmable) |
| Column Oven Temp. Range | 5–85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Noise | ±0.25 × 10⁻⁵ AU (254 nm) |
| Drift | 1.0 × 10⁻⁴ AU/h |
| Warranty | 6 months |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | U3000 |
| Pump | LPG-3400SD Quaternary Low-Pressure Gradient Pump |
| Autosampler | WPS-3000SL Analytical |
| Detector | VWD-3100 Variable Wavelength UV-Vis Detector |
| Column Oven | TCC-3000RS |
| Software | Chromeleon™ 7.2 or later |
| Max Pressure | 62 MPa (620 bar) |
| Flow Rate Range | 0.001–10 mL/min |
| Injection Volume | 0.01–100 µL |
| Wavelength Range | 190–900 nm |
| Temperature Control Range | 5–110 °C |
| Warranty | 12 months |