| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Model | Legend Micro 17 / Legend Micro 17R / Legend Micro 21 / Legend Micro 21R |
| Max RCF | 17,000 × g / 21,000 × g |
| Max Speed | 13,300 rpm / 14,800 rpm |
| Capacity | 24 × 1.5 mL / 2.0 mL tubes |
| Drive System | Brushless frequency-sensing direct-drive motor |
| Temperature Range (Refrigerated models) | –9 °C to 40 °C |
| Noise Level | ≤56 dB(A) |
| Acceleration/Deceleration Time | 11–13 s |
| Safety Features | Automatic rotor recognition, lid interlock, imbalance detection, self-diagnostic system, electronic circuit protection |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), FDA 21 CFR Part 11-ready software architecture |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model Numbers | 50135643, 50135648 |
| Instrument Type | Floor-Model Ultracentrifuge |
| Speed Range | Up to 150,000 rpm (Model-Dependent) |
| Maximum RCF | 1,048,000 × g |
| K-Factor Range | As low as 14–35 (Rotor-Dependent) |
| Noise Level | <45 dBA |
| Footprint | 0.53 m² (5.7 ft²) |
| Rotor Compatibility | Fixed-angle, swinging-bucket, vertical rotors |
| Tube Capacity | 0.2–30 mL |
| Sample Types | Viruses (HIV, SRSV, rotavirus), organelles (ribosomes, mitochondria, microsomes), lipoproteins, nanoparticles, nucleic acids |
| Drive System | Brushless DC motor with imbalance detection and auto-shutdown |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Sovall X4R Pro-MD |
| Configuration | Floor-standing or benchtop, refrigerated |
| Maximum RCF (fixed-angle) | >25,000 × g |
| Maximum RCF (swing-bucket) | >7,000 × g |
| Capacity | 1.6 L (4 × 400 mL) or 4 L (4 × 1000 mL) |
| Brand | UXS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | 166Q |
| Automation Level | Fully Automatic |
| Channel Configuration | Multi-Channel |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control Range | 0.001–80 mL/min |
| Eluent Solvent Options | Single Solvent System |
| Sample Throughput | 6 Samples Simultaneously, Up to 72 Sequential Samples |
| Sample Loading Volume | Unlimited |
| Wetted Materials | Stainless Steel (316), Polytetrafluoroethylene (PTFE), Borosilicate Glass |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AE-03 |
| Extraction Efficiency | 95% |
| Extraction Cycle Time | 2–4 min per sample (adjustable range: 1–30 min) |
| Agitation Method | Pneumatic Oscillation |
| Simultaneous Extraction Capacity | 3 samples |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AE600 |
| Extraction Efficiency | ≥95% |
| Extraction Time | 2–4 min per sample (adjustable) |
| Agitation Method | Recirculating Pneumatic Agitation |
| Simultaneous Extraction Capacity | 6 samples |
| Brand | Spectra Invent |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AT10 / AT14 |
| Pricing | Available Upon Request |
| Brand | Spectra Invent / Chinainvent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX100 |
| Quotation | Upon Request |
| Extraction Efficiency | ≥95% |
| Extraction Cycle Time | 3 min per sample (adjustable from 1–1000 s) |
| Agitation Method | Pneumatic Oscillation |
| Simultaneous Extraction Positions | 3 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SPG |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SPG |
| Pricing | Available Upon Request |
| Brand | STKJ |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HPR |
| Maximum Temperature | 350 °C |
| Pressure Range | Up to 40 MPa (5800 psi) — configurable up to 68.9 MPa (10,000 psi) per ASME-certified vessel variants |
| Vessel Volume | 50 mL to 8 L |
| Number of Reaction Channels | 1–4 |
| Maximum CO₂ or Solvent Flow Rate | 660 mL/min |
| Sample Compatibility | Plant matrices, pharmaceutical actives, natural products, polymers, catalysts |
| Safety Features | ASME-compliant pressure vessels, rupture disc protection, magnetic drive dual-impeller agitation, integrated thermal and overpressure interlocks |
| Control Interface | Color TFT touchscreen with PID temperature control, programmable ramp/soak profiles, real-time pressure monitoring, stirrer speed regulation |
| Data Output | RS-232 serial interface for external logging and GLP-compliant data capture |
| Brand | STKJ |
|---|---|
| Origin | Beijing, China |
| Model | SFT-120XW-D |
| Max Temperature | 250 °C |
| Max Pressure | 48 MPa |
| Extraction Volume Range | 5–1000 mL |
| Flow Control Resolution | 0.01 mL/min |
| Pressure Control Accuracy | ±1–2 psi |
| Pump Speed Range | 0–2500 rpm |
| Cooling Method | Electronic Refrigeration (pump head < −4 °C) |
| Reactor Options | Customizable single- or multi-vessel configurations up to 1000 mL total volume |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Available Upon Request |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 28423-U |
| Automation Level | Semi-Automatic |
| Channel Count | Multi-Channel (6-12 positions, configurable) |
| Extraction Format | Cartridge-Based Column Extraction |
| Compliance | ASTM D6988, EPA Method 1613/1668C, ISO 18073, HJ 77.1–77.4-2008 |
| Solvent Reduction | Up to 60% vs. Manual SPE |
| Processing Time Savings | 24–48 hours per batch |
| Average Recovery Rate | ≥85% for PCDD/Fs and DL-PCBs |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | 57265 |
| Automation Level | Semi-Automatic |
| Channel Count | Single-Channel |
| Extraction Format | Column-Based SPE |
| Flow Rate Control Range | 0.1–30 mL/min |
| Solvent Reservoir Positions | 24 |
| Sample Capacity | 24 Samples |
| Sample Loading Volume | 1–30 mL |
| Wetted Materials | Borosilicate Glass |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Product Type | Imported SPME Fiber Assembly |
| Model Numbers | 57300-U (Manual), 57301 (Automated) |
| Packaging | 3 fibers per vial |
| Coating | Polydimethylsiloxane (PDMS), 100 µm thickness |
| Fiber Substrate | Fused silica |
| Needle Gauge | 24 ga |
| Compatibility | Manual SPME holder (e.g., 57330-U) and automated SPME autosamplers (e.g., CTC Analytics PAL, Gerstel MPS) |
| Target Analytes | Volatile and semi-volatile non-polar compounds (MW 60–275) |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Type | Manual (57310-U) / Automated (57311) |
| Coating | Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), 65 µm thickness |
| Fiber length | 10 mm |
| Needle gauge | 24 ga |
| Pack size | 3 fibers per vial |
| Compatibility | GC, GC-MS, HPLC-MS (with derivatization or specialized interface) |
| Recommended analyte MW range | 50–300 Da |
| Application focus | Volatile and semi-volatile polar/non-polar compounds including amines, nitroaromatics, and low-MW VOCs |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Coating | Carboxen/Polymethylsiloxane (CAR/PDMS) |
| Fiber Diameter | 75 µm |
| Configuration | Manual (57318) or Autosampler-Compatible (57319) |
| Pack Size | 3 fibers per vial |
| Target Analytes | Volatile and semi-volatile organic compounds (MW 30–225) |
| Compliance | Designed for ASTM D6866, EPA Method 8260C/8270E, ISO 17025-accredited laboratories |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Product Type | Imported Laboratory Consumable |
| Kit Contents | 75 µm Carboxen/PDMS, 65 µm PDMS/DVB, 85 µm Polyacrylate Fibers (3 fibers total) |
| Compliance | Designed for ASTM D5845, EPA Method 8260C/624.1/524.2, ISO 17937, USP <467>, and GLP/GMP-aligned workflows |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | 57324-U / 57325-U |
| Packaging | 3 fibers per vial |
| Coating Types | 100 µm PDMS, 65 µm PDMS/DVB, 75 µm CAR/PDMS |
| Reusability | ≥100 extractions (up to 200 under clean-sample conditions) |
| Compliance | Designed for ASTM E2878, ISO 17025-compliant labs, compatible with USP <467> residual solvent and flavor profiling workflows |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Product Type | Imported SPME Fiber for Volatile and Semi-Volatile Compounds (C₃–C₂₀) |
| Model | 57328-U (Manual) / 57329-U (Automated) |
| Coating | Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), 50/30 µm |
| Package | 3 fibers per vial |
| Compatibility | GC, GC-MS, HS-GC, HS-GC-MS |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | 57330-U / 57311 |
| Compatibility | Manual sampling with GC/HPLC inlet systems |
| Sample vial capacity | Compatible with 4 mL and 15 mL vials |
| Reusability | Indefinitely reusable with replaceable SPME fibers |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | 57333-U (for 4 mL vials) / 57357-U (for 15 mL vials) |
| Sample Vial Capacity | 4 mL or 15 mL |
| Number of Samples | 8 positions |
| Compatibility | Manual SPME fiber holder only |
| Base Design | Compatible with standard magnetic stirrer/heater plates |
| Temperature Control | Dependent on external heater/stirrer unit |
| Stirring Speed | Dependent on external magnetic stirrer |
| Regulatory Compliance | Designed for use in GLP/GMP-compliant laboratories per ASTM D7216 and ISO 17025 workflows |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | ENVI-Disk |
| Type | Disk-Based Solid Phase Extraction (SPE) System |
| Disk Options | ENVI-8 (C8-bonded, 24 mm), ENVI-18 (C18-bonded, 24 mm), 47 mm & 90 mm formats available |
| Vacuum Source Compatibility | GAST 74329 (imported) or domestic portable vacuum pump |
| Accessories | PTFE spiral clamp (ID 47 mm), PTFE edge gasket, 1 L conical flask (40/35 joint), 25 × 250 mm collection tubes, TF-lined vacuum buffer bottle |
| Compliance | Designed for EPA Methods 508.1, 525.3, 625.1 |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | KL-SPMETS-JG (GB/T 32470-2016 Compliant) |
| Sample Vial Capacity | 40 mL / 60 mL |
| Throughput | 4 samples per run |
| Extraction Temperature | 100 °C |
| Stirring Speed | 1150 rpm |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | KLGC-SPME |
| Configuration | Manual SPME Holder with Adjustable Depth Sleeve and Replaceable Coated Fibers |
| Compliance | Designed for ASTM D7219, ISO 17935, USP <467>, EPA Method 8260/8270 Compatible |
| Software Integration | Standalone manual operation |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | KLVIPSPE-12 / KLVIPSPE-24 |
| Automation Level | Semi-Automatic |
| Channel Count | 12- or 24-Channel |
| Extraction Mode | Cartridge-Based SPE |
| Flow Rate Control | Adjustable via patented spiral valve |
| Compatible Solvents | All common organic and aqueous solvents |
| Sample Capacity | Up to 12 or 24 samples simultaneously |
| Sample Load Volume | 1 mL to unlimited (gravity/vacuum-assisted) |
| Solvent-Wetted Materials | PTFE, borosilicate glass, polypropylene |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | KLVIPSPE-12 |
| Automation Level | Fully Automated |
| Channel Count | 12-Channel |
| Extraction Type | Cartridge-Based SPE |
| Flow Control | Precision Spiral-Valve Flow Regulation |
| Solvent Compatibility | Broad Spectrum (Including Acetonitrile, Methanol, Ethyl Acetate, Hexane, Dichloromethane, and Aqueous Buffers) |
| Max Simultaneous Samples | 12 |
| Sample Loading Volume Range | 1 mL to Unlimited (with Optional Large-Volume Samplers) |
| Wetted Materials | PTFE Tubing, Borosilicate Glass Chamber, Polypropylene Collection Rack |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | KLVIPSPE-24 |
| Automation Level | Manual |
| Number of Channels | 24 |
| Extraction Type | Column-based SPE |
| Flow Control | Precision spiral-flow valve |
| Solvent Compatibility | Compatible with all common organic and aqueous solvents (e.g., methanol, acetonitrile, ethyl acetate, water, buffer solutions) |
| Maximum Sample Capacity | 24 samples simultaneously |
| Sample Loading Volume | 1 mL to unlimited (with optional large-volume samplers) |
| Wetted Materials | Borosilicate glass chamber and PTFE (polytetrafluoroethylene) tubing/valves |
| Cross-Contamination Mitigation | Disposable PTFE column connection tubes with polypropylene Luer tips |
| Vacuum Interface | 1/4″ barbed vacuum port with integrated solvent-resistant vacuum gauge and sealable valve |
| Collection Vessel Support | Polypropylene rack accommodating 1–10 mL vials, 10/16 mm test tubes, scintillation vials (20 mL), and autosampler vials |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Supelco |
| Pricing | Upon Request |