Shaker
Filter
Showing 511–540 of 1023 results
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200A |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Control Method | PID Microprocessor |
| Shelving | Dual-tier platform (2 shelves) |
| Shelf Dimensions | 439 × 528 mm each |
| Capacity per Shelf | 100 mL × 25 / 250 mL × 20 / 500 mL × 12 / 1000 mL × 6 / 2000 mL × 4 |
| Standard Fixture Configuration | Lower shelf with fixed 500 mL clamps (×12), upper shelf with universal spring clamps |
| Power Consumption | 1.3 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 740 × 780 × 1260 mm |
| Net Weight | 170 kg |
| Display | 7-inch 16-bit true-color touchscreen interface |
| Data Logging | Internal storage (1-year history), USB export (CSV/PDF), optional thermal printer output |
| Safety Features | Door-activated motor stop, overtemperature audiovisual alarm + auto cut-off, self-diagnostic system, keypad lock, power-fail memory |
| Optional Upgrades | Remote monitoring via mobile app (iOS/Android), external environmental temperature probe, UV sterilization module, interior LED illumination |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200G |
| Shaker Type | Full-Temperature Orbital Incubator with Integrated Illumination |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Oscillation Amplitude | Ø26 mm |
| Temperature Range | 4–65°C (dark) / 10–65°C (with illumination) |
| Number of Shaking Platforms | 2 |
| 光照 Intensity | 0–16,000 lx (standard), up to 30,000 lx (optional) |
| Temperature Resolution | ±0.1°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Platform Dimensions | 439 × 528 mm per shelf |
| Power Consumption | 1.3 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 740 × 780 × 1235 mm |
| Net Weight | 170 kg |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200R |
| Temperature Range | 4–65 °C (CO₂ mode: 4–60 °C) |
| CO₂ Range | 0–20% |
| CO₂ Uniformity | ±0.1% |
| CO₂ Control Accuracy | ±0.1% |
| Oscillation Frequency | 30–300 rpm (±1 rpm) |
| Amplitude | 26 mm (Ø) |
| Timer Range | 0–999 h 59 min |
| Shelf Quantity | 2 |
| Shelf Dimensions | 439 × 528 mm |
| Temp. Uniformity | ±0.5 °C at 37 °C |
| Temp. Resolution | 0.1 °C |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 1.3 kW |
| Net Weight | 170 kg |
| External Dimensions (W×D×H) | 740 × 780 × 1260 mm |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-500 |
| Instrument Type | Full-Temperature Orbital Shaker / Incubator Shaker |
| Timer Range | 0–9999 min (up to 166.6 h) |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm / 50 mm |
| Temperature Range | 4–65 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Fluctuation | ±0.3 °C (at 37 °C) |
| Temperature Resolution | 0.1 °C |
| Control Method | PID Microprocessor-Based Control |
| Shelf Quantity | 2 adjustable platforms |
| Platform Dimensions | 830 × 508 mm per shelf |
| Power Consumption | 2.1 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1080 × 850 × 1440 mm |
| Net Weight | 300 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-500A |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Oscillation Amplitude | Ø26 mm (standard), 50 mm (optional) |
| Temperature Range | 4–65 °C |
| Number of Shaking Platforms | 2 |
| Platform Dimensions | 830 × 500 mm each |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Resolution | ±0.1 °C |
| Frequency Accuracy | ±1 rpm |
| Power Consumption | 2.1 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1080 × 850 × 1440 mm |
| Net Weight | 300 kg |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-70 |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–9999 min (configurable in minutes or hours) |
| Oscillation Speed | 10–400 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–65°C |
| Temperature Resolution | 0.1°C |
| Temp. Uniformity | ±0.5°C (at 37°C) |
| Temp. Stability | ±0.3°C (at 37°C) |
| Shelf Dimensions | 520 × 430 mm |
| Standard Capacity | 100 mL × 25 |
| Standard Fixture | Universal Spring Clamps |
| Power Consumption | 0.7 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 860 × 680 × 570 mm |
| Display | LCD with PID Microprocessor Control |
| Motor Type | Brushless DC Motor |
| Drive Mechanism | Multi-axis Integrated Eccentric Cam Drive |
| Safety Features | Door-Interlock Stop, Over-Temp Audio-Visual Alarm + Auto Cut-off, Self-Diagnostic System, Power-Fail Data Retention |
| Operating Ambient | 5–25°C |
| Cooling System | Imported CFC-Free Compressor with Optimized Heat Dissipation Architecture |
| Air Circulation | Forced Convection via Centrifugal Air Duct |
| Illumination | Built-in White LED Light |
| UV Sterilization Lamp | Integrated (254 nm) |
| Viewing Window | Tempered Double-Layer Hollow Glass Door with Ø30 mm Access Port |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-90 |
| Temperature Range | 4–65 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Resolution | 0.1 °C |
| Oscillation Frequency | 10–400 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Timer Range | 0–9999 min |
| Platform Dimensions | 520 × 430 mm |
| Standard Capacity | 100 mL × 25 |
| Power Consumption | 0.7 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 900 × 730 × 640 mm |
| Control System | 16-bit true-color touchscreen with PID algorithm |
| Data Storage | 1-year local history |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-90G |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Oscillation Frequency | 10–400 rpm |
| Oscillation Amplitude | Ø26 mm |
| Temperature Range (Dark) | 4–65°C |
| Temperature Range (Illuminated) | 10–65°C |
| Number of Shelving Plates | 1 |
| Illuminance Range (Standard) | 0–16,000 lx (multi-step adjustable) |
| Illuminance Range (Optional) | 0–30,000 lx |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Control System | 16-bit true-color touchscreen HMI |
| Timer Range | 0–999 h 59 min |
| Power Consumption | 0.7 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 900 × 736 × 640 mm |
| Tray Dimensions | 520 × 430 mm |
| Standard Capacity Configurations | 100 mL × 25 |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-115 |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 1–9999 min (or hr) |
| Oscillation Frequency | 10–350 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Stability | ±0.3 °C (at 37 °C) |
| Shelf Quantity | 3 |
| Shelf Dimensions (W×D) | 580 × 460 mm |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 0.7 kW |
| External Dimensions (W×D×H) per Layer | 950 × 800 × 600 mm |
| Shelf Loading Capacity (per layer) | 100 mL × 53 / 250 mL × 30 / 500 mL × 20 / 1000 mL × 12 / 2000 mL × 8 / 3000 mL × 5 |
| Standard Control | LCD Display (optional: full-color touchscreen controller) |
| UV Sterilization | integrated |
| Door Safety Interlock | yes |
| Motor Type | brushless servo motor |
| Drive Mechanism | three-axis eccentric cam drive |
| Air Circulation | centrifugal forced-air system |
| Chamber Material | seamless mirror-finish stainless steel (304) |
| Viewing Window | tempered double-glazed glass with Ø30 mm access port |
| Lighting | internal LED illumination |
| Refrigeration | fluorine-free compressor with dust-filtered cooling circuit |
| Programmable Functions | bidirectional rotation (forward/reverse/stop), multi-segment timing, power-loss memory, self-diagnostic alerts, over-temperature audiovisual alarm & auto-shutdown |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-115S |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–9999 min (up to 166.6 h) |
| Oscillation Speed | 10–1200 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 3 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Stability | ±0.3 °C at 37 °C |
| Tray Dimensions | 580 × 460 mm |
| Capacity per Tray | 16 microplate clamps |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 1 kW |
| External Dimensions (per unit) | 950 × 800 × 600 mm (W × D × H) |
| Tray Quantity | 1 per layer |
| Stackable Configurations | 1–3 layers |
| Refrigerant | Eco-friendly non-CFC compressor-based cooling system |
| Safety Features | Over-temperature alarm, auto power cutoff on fault, auto-restart after power recovery, door-open pause, UV sterilization module |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228A |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm / 50 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Control Method | PID Microprocessor |
| Shelf Dimensions | 850 × 530 mm |
| Single-Shelf Capacity | 100 mL × 95, 250 mL × 56, 500 mL × 38, 1000 mL × 22, or 2000 mL × 12 |
| Standard Shelf Load | 100 mL × 45, 250 mL × 28, 500 mL × 28, 1000 mL × 14, or 2000 mL × 9 |
| Power per Shelf | 1.5 kW |
| Voltage | AC 220 V ±10%, 50–60 Hz |
| Single-Shelf External Dimensions | 1368 × 900 × 600 mm |
| Net Weight per Shelf | 220 kg |
| Environmental Operating Range | 5–25 °C |
| Display | 7-inch 16-bit true-color touchscreen |
| Data Storage | 1-year history retention |
| Connectivity | USB data export, optional remote monitoring via mobile app |
| Safety Features | Door-safety interlock, over-temperature alarm & cutoff, self-diagnostic system, encrypted operation lock, condensate drainage port, IPX4-rated motor, double-layer waterproof baffle, UV sterilization lamp, integrated LED illumination |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228A |
| Temperature Range | 4–65°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Temperature Resolution | 0.1°C |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm / 50 mm |
| Timer Range | 0–999 h 59 min |
| Shelf Capacity (per layer) | 100 mL × 60, 250 mL × 28, 500 mL × 28, 1000 mL × 14, 2000 mL × 9, or 3000 mL × 8 |
| Shelf Dimensions | 930 × 530 mm |
| Power Consumption (per layer) | 1.5 kW |
| Display | 7-inch 16-bit true-color touchscreen |
| Control Modes | Constant-value & programmable operation |
| Data Storage | 1-year history with USB export & real-time curve printing |
| Safety Features | Door-interlocked stop, over-temperature alarm & auto-shutdown, waterproof motor, triple liquid containment system, environmental temperature monitoring, PID control, UV sterilization & internal lighting |
| Optional Upgrades | CO₂ integration, remote mobile APP monitoring, external thermal printer |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228G |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm |
| Temperature Range (Dark) | 4–65 °C |
| Temperature Range (Illuminated) | 10–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Control Method | PID Microcomputer |
| Illuminance | 0–16,000 lx (standard), optional 0–30,000 lx |
| Shelf Dimensions | 850 × 530 mm |
| Single-Shelf Capacity | 100 mL × 95, 250 mL × 56, 500 mL × 38, 1000 mL × 22, or 2000 mL × 12 |
| Standard Configured Capacity per Shelf | 100 mL × 45, 250 mL × 28, 500 mL × 28, 1000 mL × 14, or 2000 mL × 9 |
| Power Consumption (per Shelf) | 1.5 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (per Shelf) | 1368 × 900 × 600 mm |
| Net Weight (per Shelf) | 220 kg |
| Display | 7-inch 16-bit true-color touchscreen |
| Data Storage | 1-year history retention |
| USB Export | Supported for data backup and printing |
| Environmental Monitoring | External ambient temperature probe included |
| Safety Features | Door-activated motor stop, over-temperature audiovisual alarm with auto-shutdown, self-diagnostic fault detection, waterproof motor, triple liquid containment system, UV sterilization lamp, LED full-spectrum illumination with multi-level intensity control |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228R |
| Shaker Type | Refrigerated/Heated Orbital Incubator Shaker |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm (±1 rpm) |
| Orbit Diameter | Ø26 mm / 50 mm |
| Temperature Range | 4–65 °C (CO₂ mode: 4–60 °C) |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Stability | ±0.3 °C at 37 °C |
| Temperature Resolution | 0.1 °C |
| CO₂ Control Range | 0–20% |
| CO₂ Sensor | Imported NDIR (Non-Dispersive Infrared) |
| CO₂ Accuracy | ±0.1% |
| CO₂ Distribution Uniformity | ±0.1% |
| Shelf Dimensions | 930 × 530 mm |
| Single-Shelf Capacity | 100 mL × 60 / 250 mL × 45 / 500 mL × 28 / 1000 mL × 14 / 2000 mL × 15 / 3000 mL × 8 |
| Power Consumption (per shelf) | 1.5 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1450 × 920 × 600 mm |
| Display | 16-bit true-color touchscreen controller with real-time curve plotting, data logging (1-year retention), USB export, password lock, and audit-ready event logging |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Model | CSTHZ-82 |
| Timer Range | 1–120 min |
| Oscillation Frequency | 30–300 rpm (orbital) |
| Oscillation Amplitude | 26 mm |
| Temperature Control Range | RT to 90 °C |
| Temperature Accuracy | ±0.5 °C |
| Ultrasonic Frequency | 40–80 kHz (dual-frequency, adjustable) |
| Ultrasonic Power | 800 W |
| Ultrasonic Timer | up to 9999 min or continuous mode |
| Bath Volume | 52 L (560 × 495 × 190 mm) |
| Tray Dimensions | 420 × 350 mm |
| Cooling Function | Yes |
| Heating Power | 1.8 kW |
| Input Voltage | AC 220 V, 50 Hz |
| Number of Platforms | 1 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water Bath Constant-Temperature Shaker |
| Model | DKZ-3 |
| Timing Range | 1–999 min |
| Oscillation Frequency | 40–150 rpm |
| Amplitude | 30 mm (orbital) |
| Temperature Range | RT + 5 °C to 100 °C |
| Temperature Uniformity | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Chamber Material | Stainless Steel (304) |
| Chamber Dimensions (W×D×H) | 618 × 310 × 250 mm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1650 W |
| Number of Platforms | 1 |
| Display | Digital LED for temperature and speed |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FZ-12 |
| Instrument Type | Tumbling Shaker |
| Timer Range | 0–59 h 59 min |
| Rotational Speed Range | 0–60 rpm (no-load) |
| Temperature Range | Ambient to 60 °C |
| Platform Quantity | 1 |
| Sample Capacity | Compatible with 2 L containers (glass, PE, PTFE, and other chemically resistant vessels) |
| Construction | Stainless steel chamber with electrostatic powder-coated exterior |
| Safety Features | Overload protection circuit |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | HZQ-311C |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0.1 h to 999 h 59 min |
| Oscillation Frequency | 30–250 rpm |
| Orbit Diameter | 20 mm |
| Temperature Range | 4–60 °C |
| Number of Shaking Platforms | 1 |
| Platform Dimensions | 920 × 500 mm |
| Power Input | 1700 W |
| Display | Large Backlit LCD with Menu-Driven Interface |
| Construction | Stainless Steel Interior & Shaking Surface |
| Insulation | CFC-Free Polyurethane Foam |
| Safety Features | Independent Over-Temperature Cut-Off, Door-Interlocked Shutdown, Brushless AC Motor, Programmable Multi-Stage Control (Optional), RS-485/USB Data Export (Optional) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Temperature-Controlled Orbital Shaker |
| Model | KBC-82A |
| Timer Range | 1–999 h |
| Oscillation Speed | 30–300 rpm |
| Orbit Diameter | 30 mm |
| Temperature Range | Ambient to 60 °C |
| Platform Quantity | 1 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LB-2102 |
| Timer Range | 0–999 h |
| Oscillation Frequency | 40–280 rpm |
| Orbit Diameter | 50 mm |
| Temperature Range | 4–60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Stability | ±0.5 °C |
| Tray Dimensions | 750 × 500 mm |
| Number of Trays | 2 |
| Max Capacity | 70 × 250 mL or 50 × 500 mL or 24 × 1000 mL |
| Drive Type | Brushless DC Motor |
| Control System | Microprocessor-based with Programmable Multi-Stage Profile (up to 10 segments) |
| Safety Features | Independent Over-Temperature Cut-off, Door Interlock Switch, Motor Overheat Protection, Power-Fail Recovery, Soft-Start Acceleration |
| Optional | Humidity Control Module, USB Data Logging Interface, Stainless Steel Mirror-Finish Interior, Tempered Glass Viewing Window, Inert Gas Inlet Port |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP-8A |
| Instrument Type | Horizontal Oscillating Shaker |
| Timer Range | 1–999 min |
| Oscillation Speed | 0–200 rpm |
| Stroke Amplitude | 40 mm |
| Number of Platforms | 1 |
| Maximum Bottle Capacity | 16 × 2000 mL |
| Power Consumption | 120 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Compliance | HJ 557–2009 (China Environmental Protection Standard for Solid Waste Leaching Toxicity – Horizontal Oscillation Method) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | TCLB-20 |
| Type | Inversion Shaker |
| Timer Range | 1–999 h |
| Oscillation Speed | 0–60 rpm |
| Oscillation Amplitude | 180° (inversion motion) |
| Temperature Range | Ambient +5°C to 50°C |
| Shelf Quantity | 1 stainless-steel platform |
| Sample Capacity | Up to six 2 L containers (glass, PE, PTFE, or HDPE) |
| Construction | Stainless steel outer chamber with electrostatic epoxy coating |
| Safety Features | Overload protection circuit |
| Control System | Digital PID temperature controller + microprocessor-based speed regulator |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | TCLB-6A |
| Instrument Type | Inverting Shaker |
| Temperature Range | Ambient +5°C to 60°C |
| Timer Range | 0–999 h |
| Speed Range | 0–45 rpm (no-load), 30 ±2 rpm (loaded, 2 L bottles) |
| Number of Shaking Plates | 2 |
| Chamber Material | Stainless steel housing with electrostatic powder coating |
| internal fixtures | aluminum alloy |
| Safety Features | Overload protection |
| Compatible Vessels | 2 L glass, PE, PTFE, and ZHE containers |
| Compliance | Designed for GLP-compliant laboratory workflows requiring traceable, repeatable sample inversion under controlled thermal conditions |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | YY-82A |
| Instrument Type | General-Purpose Temperature-Controlled Orbital Shaker |
| Timer Range | 1–120 min |
| Oscillation Speed | 0–280 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient +5°C to 300°C |
| Heating Medium | Thermal Oil |
| Temperature Control | Digital PID |
| Temperature Accuracy | ±5°C |
| Chamber Material | Stainless Steel (Interior), Powder-Coated Steel (Exterior) |
| Platform | Single Deck |
| Packaging | Reinforced Wooden Crate |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-2112 |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 1–999 h |
| Oscillation Frequency | 30–280 rpm |
| Amplitude | 30 mm (horizontal circular) |
| Temperature Range | 5–60 °C |
| Shelf Quantity | 2 |
| Tray Dimensions | 800 × 500 mm |
| External Dimensions (per shelf) | 1280 × 770 × 1500 mm |
| Height Occupancy (stacked) | 1930 mm |
| Heating Power | 500 W (per shelf) |
| Cooling Power | 280 W (per shelf) |
| Refrigeration System | Imported compressor with R134a refrigerant |
| Control System | Microprocessor-based LED display with membrane keypad |
| Safety Features | Overheat protection, low-temperature cutoff, leakage current protection, door-open auto-stop, parameter encryption, and real-time alarm prompts for abnormal conditions |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-2112B |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0–500 h |
| Oscillation Frequency | 30–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 25 mm |
| Temperature Control Range | Ambient +5°C to 60°C |
| Temperature Resolution | ±0.1°C |
| Temperature Uniformity | ≤±1°C (at 25°C) |
| Temperature Stability | ≤±0.5°C (at 37°C) |
| Shelf Quantity | 2 |
| Shelf Dimensions | 970 × 560 mm |
| Chamber Volume | 582 L |
| Internal Dimensions | 1095 × 625 × 850 mm |
| External Dimensions | 1200 × 820 × 1600 mm |
| Net Weight | 425 kg |
| Power Consumption | 1150 W |
| Input Voltage | AC 220 V, 50/60 Hz |
| Maximum Load Capacity | 100 mL × 164 |
| Standard Configuration | 250 mL × 45 & 500 mL × 35 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-211C |
| Instrument Type | Full-temperature orbital shaker |
| Timer Range | 999 h |
| Oscillation Frequency | 40–280 rpm |
| Oscillation Amplitude | 26 mm (Φ) |
| Temperature Control Range | 4–60 °C |
| Humidity Control Range | 50–95 %RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±1 %RH |
| Temperature Accuracy | ≤±0.1 °C |
| Humidity Accuracy | ±3 %RH |
| Frequency Accuracy | ±1 rpm |
| Shelving | 1 stainless steel polished platform (970 × 480 mm) |
| External Dimensions (W×D×H) | 1260 × 830 × 1010 mm |
| Net Weight | 230 kg |
| Cooling System | Air-cooled, R134a refrigerant, frost-free operation |
| Humidification | External high-efficiency humidifier |
| Drive Mechanism | Brushless AC motor, constant-torque, wide-speed-range |
| Control Algorithm | PID with environmental scanning microprocessor |
| Display | Backlit LCD with real-time parameter monitoring |
| Interface | RS-232 port for data export |
| Safety Protections | Independent over-temperature cutoff, over-speed cutoff, leakage current protection, circuit breaker, compressor overload protection, low-water-level alarm, sensor fault detection, power-fail recovery, auto-restart after outage |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water Bath Constant-Temperature Shaker / Platform Shaker |
| Timer Range | 1–999 h |
| Oscillation Frequency | 0–280 rpm |
| Oscillation Amplitude | 200 mm |
| Temperature Control Range | Ambient +5°C to 100°C |
| Number of Platforms | 1 |
| Operating Mode | Reciprocating Motion |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Varioshake |
| Instrument Type | Water-Bath Temperature-Controlled Orbital Shaker |
| Timer Range | 1 min – 999 h |
| Oscillation Frequency | 20–250 rpm |
| Orbit Diameter | 10–32 mm |
| Temperature Range | 20–70 °C (with water cooling) / 28–70 °C (ambient air operation) |
| Temperature Stability | ±0.2 K |
| Display Resolution | 0.1 °C |
| Control Interface | Membrane Keypad with Symbol-Based UI |
| Safety Features | Door-Interlocked Shutdown (shaking & heating), Visual/Audible Low-Temperature Alarm |
| Communication | RS232 Serial Interface |
| Chamber Construction | Electrogalvanized Steel with Powder-Coated Finish |
| Tray Capacity | 1 standard platform (dual-tray configuration supported for containers ≤180 mm height) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 15 B |
| Timer Range | 1 min to 99:59 h |
| Oscillation Frequency | 20–300 rpm |
| Amplitude | 30 mm |
| Platform Quantity | 1 |
| Max Load Capacity | 15 kg |
| Platform Dimensions (W × D) | 450 × 450 mm |
| Ambient Temperature Range | 10–50 °C |
| Power Consumption | 0.07 kW |
| Overall Dimensions (W × D × H) | 480 × 487 × 160 mm |
| Weight | 18 kg |