| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Keebio-96P |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well format |
| Max Heating Rate | 6°C/s |
| Temperature Accuracy | ≤ ±0.1°C at 55°C |
| Block Uniformity | ≤ ±0.2°C at 55°C |
| Programmable Ramp Rate | 0.1–5°C/s |
| Gradient Range | Horizontal 1–24°C / Vertical 1–30°C |
| Gradient Temp Range | 30–105°C |
| Block Temp Range | 0–105°C |
| Heat Lid Temp Range | 30–115°C |
| Heat Lid Precision | 0.1°C |
| Max Cycles | 200 |
| Program Storage | 20,000 protocols |
| 4°C Hold Function | Yes |
| Power Input | 100–240 VAC, 50/60 Hz |
| Output Power | 800 W |
| Dimensions (D×W×H) | 380 × 280 × 220 mm |
| Net Weight | 8 kg |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-96S |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL format) |
| Max Heating/Cooling Rate | 5 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C at 55 °C |
| Block Uniformity | ≤ ±0.2 °C at 55 °C |
| Gradient Range | 1–30 °C (±0.3 °C accuracy), 30–105 °C |
| Temperature Control Modes | Block & Tube |
| Programmable Ramp Rate | 0.1–5 °C/s |
| Max Cycles | 100 |
| Time Increment/Decrement | 1–600 s |
| Temp Increment/Decrement | 0.1–10 °C |
| Program Storage | 20,000 protocols |
| 4 °C Hold Function | Yes |
| Power Input | 100–240 VAC, 50/60 Hz |
| Output Power | 700 W |
| Dimensions (D×W×H) | 293 × 190 × 183 mm |
| Net Weight | 5.5 kg |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-96G |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL format, compatible with full-skirted, half-skirted, non-skirted plates |
| Temperature Range | 4–99.9 °C |
| Max Heating/Cooling Rate | 5.0 °C/s |
| Block Temperature Uniformity | ±0.3 °C at 55 °C |
| Gradient Range | Up to 36 °C, accuracy ±0.5 °C |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Temperature Control Modes | BLOCK mode (block surface temperature), TUBE mode (algorithm-based estimation of actual sample temperature) |
| Ramp Rate Adjustment | 0.1–4.5 °C/s |
| Programmable Cycles | Up to 99 |
| Time Increment/Decrement | 0.1–9 min 59 sec |
| Temp Increment/Decrement | 0.1–9.9 °C |
| Hold Temperature | 4 °C long-term hold |
| Heat Lid Temperature Range | Room temp +5 to 110 °C |
| Heat Lid Accuracy | ±5 °C |
| Heat Lid Display Resolution | 0.1 °C |
| Power Input | 100–240 VAC, 50/60 Hz |
| Max Power Consumption | 600 W |
| Dimensions (D×W×H) | 280 × 187 × 190 mm |
| Net Weight | 7 kg |
| Display | 7-inch color capacitive touchscreen |
| Data Interface | USB port |