| Brand | Jiapeng |
|---|---|
| Model | BS-16A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 16 × 100 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 460 mm |
| Weight | 6.5 kg |
| Data Retention | 10 years after power loss |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS polymer (injection-molded, solvent-resistant grade) |
| Panel Angle | 35° ergonomic tilt |
| Tube Tray | Circular, digitally labeled (01–16), interchangeable with standardized 16-position racks |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic or piston-driven pumps |
| Valve Type | Keebio precision fluid shut-off valve (standard) |
| Brand | Jiapeng |
|---|---|
| Model | BSZ-100 |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Display | Chinese-language LCD (blue membrane, large-character) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | 10 years |
| Continuous Operation Time | >200 h |
| Housing Material | ABS (injection-molded, fully enclosed) |
| Control Interface | COM port for external pump triggering |
| Valve Type | Keebio fluid shut-off valve |
| Tube Tray | Circular, digitally numbered, solvent-resistant (optional) |
| Brand | Jiapeng |
|---|---|
| Model | JP-FCD100 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Time-based, Drop-counting, UV/absorbance Threshold-triggered |
| Tube Capacity | 100 × 12 mL |
| Touchscreen | 5.5-inch capacitive LCD |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Threshold Range | ±6 AU (requires external UV detector) |
| Peak Trigger Input | 0–100 mV analog signal |
| Delay Volume Compensation | Software-configurable |
| Valve Type | PEEK fluidic solenoid valve (organic solvent compatible) |
| Continuous Operation | >200 hours |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-100 |
| Collection Capacity | 100 tubes × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Display | 6-digit LED |
| Tube Tray | Circular, digitally numbered (001–100) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | ≥10 years |
| Continuous Operation Time | >200 h |
| Construction Material | ABS polymer (chemical-resistant, injection-molded) |
| Valve Type | Keebio fluid shut-off solenoid valve |
| Interface | RS-232 COM port for external trigger (e.g., peristaltic pump synchronization) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-40 |
| Collection Mode | Time-Based |
| Tube Capacity | 40 × 50 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Display | 6-digit LED数码 tube indicator |
| Tube Tray | Circular, digitally numbered, solvent-resistant (optional) |
| Data Retention | 10 years after power loss |
| Continuous Operation | >200 h |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Compliance | Designed for GLP-aligned lab workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BS-160A |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 5 mL per tube |
| Max. Tube Count | 160 tubes |
| Timing Range | 1 second to 24 hours (user-selectable) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | 10 years |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS plastic (injection-molded, enclosed design) |
| Tube Tray | Circular, digitally numbered, solvent-resistant (optional) |
| Valve Type | Keebio fluid shut-off valve |
| External Trigger Interface | RS-232 COM port for pump synchronization |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Model | BS-40A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 40 × 50 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Data Retention | 10 years after power loss |
| Display | 6-digit LED数码 tube |
| Tube Tray | Circular, digitally labeled, solvent-resistant (optional) |
| Enclosure Material | ABS plastic, injection-molded, fully enclosed |
| Interface | RS-232 COM port for external trigger (e.g., peristaltic pump synchronization) |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | CBS-B |
| Instrument Type | Liquid-Phase Fraction Collector |
| Collection Modes | Time-Based, Drop-Based, Peak-Based, Programmable Control |
| Tube Capacity | 100 × 12 mL (standard), optional trays: 16 × 100 mL, 36 × 50 mL, 169 × 5 mL |
| Timing Range | 1 s – 999 h 59 min 59 s |
| Drop Counting Range | 1–999 drops |
| Peak Threshold Range | 1–200 mV |
| Programmable Segments | 1–10 |
| Movement Mechanism | Suspended X-Y Positioning |
| Valve Type | 12 V DC Solenoid |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 345 × 360 × 270 mm |
| Weight | 14 kg |
| Data Retention | ≥10 years after power loss |
| Continuous Operation | >200 hours |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | DBS-100 |
| Fraction Collection Type | Liquid-phase |
| Collection Modes | Time-based, Drop-counting, Peak-triggered |
| Tube Capacity | 100 × 12 mL |
| Time Range | 1 s – 199 h 59 min 59 s |
| Drop Range | 1–9999 drops |
| Peak Threshold Range | 0–100 mV |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | 10 years |
| Display | Large Blue-backlit Chinese LCD |
| Tube Tray | Circular, Digitally Labeled (00–99) |
| Continuous Operation Time | >200 h |
| Housing Material | ABS Plastic (Injection-molded, Closed-loop Design) |
| Compliance | Designed for GLP-aligned chromatographic workflows |
| Brand | Jiapeng |
|---|---|
| Model | BS-30A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Number of Collection Positions | 30 |
| Collection Volume Capacity | Unlimited (via external containers) |
| Timing Range | 1 second to 24 hours (adjustable in 1-second increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Display | 6-digit high-brightness LED |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation Time | >200 hours |
| Housing Material | ABS (impact-resistant, solvent-resistant grade) |
| Control Interface | RS-232 COM port for external pump synchronization |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Net Weight | 6.5 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-16 |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 16 × 100 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS (injection-molded, solvent-resistant grade, optional) |
| Tube Tray | Circular, digitally labeled (01–16), 35° ergonomic tilt |
| Valve Type | Keebio fluid shut-off solenoid valve (chemically resistant) |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic or piston pumps |
| Continuous Operation Duration | >200 h |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | Jiapeng |
|---|---|
| Model | BS-160A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 160 × 5 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | ≥10 years |
| Housing Material | ABS polymer (chemical-resistant, injection-molded) |
| Display | Backlit Chinese-language LCD with menu-driven interface |
| Tube Tray | Circular, digitally numbered, solvent-compatible (optional) |
| Valve Type | Keebio fluid shut-off solenoid valve |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic pumps |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-30 |
| Type | Liquid-phase fraction collector |
| Collection mode | Time-based |
| Number of collection positions | 30 |
| Collection volume capacity | Unlimited (with external containers) |
| Timing range | 1 second to 24 hours (adjustable in 1-second increments) |
| Power failure data retention | 10 years |
| Display | 6-digit high-brightness LED |
| Housing material | ABS plastic (medical-grade, solvent-resistant grade optional) |
| Control interface | RS-232 COM port for external pump synchronization |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Input power | AC 220 V, 50/60 Hz |
| Continuous operation capability | >200 hours |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | SBS-160 |
| Fraction Capacity | 160 × 5 mL tubes |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Droplet Counting Range | 1–9999 drops |
| Peak Trigger Range | 0–100 mV (for SBS-100 variant |
| Display | Large blue-backlit Chinese LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation Time | >200 hours |
| Housing Material | ABS plastic (injection-molded, fully enclosed) |
| Tube Rack | Circular, digitally numbered (1–160), compatible with standard 12 × 75 mm or 13 × 100 mm test tubes |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic pumps (e.g., Keebio constant-flow pumps) |
| Valve Type | Solenoid-actuated fluid cutoff valve (optional solvent-resistant version available) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-160 |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 5 mL per tube |
| Max. Tube Count | 160 |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS polymer (chemical-resistant, injection-molded) |
| Panel Angle | 35° ergonomic tilt |
| Tube Rack | Circular, digitally numbered for unambiguous identification |
| Valve Type | Keebio fluid shut-off solenoid valve |
| Compatibility | Interchangeable standard tube racks (same footprint) |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic pumps |
| Brand | Jiapeng |
|---|---|
| Model | JP-FCD160 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Time-based, Drop-counting, UV/absorbance threshold-triggered |
| Tube Capacity | 160 × 5 mL |
| Touchscreen Interface | 5.5-inch capacitive LCD |
| UV Input Range | 0–100 mV (analog) / –6 to +6 AU (digital, requires external UV detector) |
| Timer Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Delay Volume Compensation | Adjustable in software |
| Valve Type | PEEK solenoid valve (organic solvent compatible, drip-free switching) |
| Continuous Operation | >200 h |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | CBS-A |
| Instrument Type | Liquid-Phase Fraction Collector |
| Collection Modes | Time-Based, Drop-Based, Peak-Based, Program-Controlled |
| Tube Capacity | 12 mL (standard, 100-tube rack) |
| Timing Range | 1 s – 999 h 59 min 59 s |
| Drop Counting Range | 1–999 drops |
| Programmable Methods | 10 user-defined protocols |
| Movement Mechanism | Suspended X-Y stepper-driven positioning |
| Display | Large-backlit Chinese-language LCD (blue membrane) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 345 × 360 × 270 mm |
| Weight | 14 kg |
| Data Retention | 10 years after power loss |
| Continuous Operation | >200 hours |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Optional Racks | 16-tube (100 mL/tube), 36-tube (50 mL/tube), 169-tube (5 mL/tube) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BS-100A |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | 10 years |
| Display | 6-digit high-brightness LED |
| Tube Tray | Circular, digitally numbered (1–100), solvent-resistant (optional) |
| Control Interface | RS-232 COM port for external pump synchronization |
| Enclosure Material | ABS polymer, injection-molded, fully enclosed |
| Panel Angle | 35° ergonomic tilt |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | SBS-100 |
| Fraction Collection Type | Liquid-phase |
| Collection Modes | Time-based, Drop-counting, Peak-triggered |
| Tube Capacity | 12 mL per tube |
| Number of Tubes | 100-position circular rack |
| Time Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Peak Detection Input | 0–100 mV analog signal |
| Display | Large blue-backlit Chinese-language LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation Time | >200 hours |
| Housing Material | ABS polymer, injection-molded, fully enclosed |
| Compliance | Designed for GLP-compliant chromatography workflows in R&D and pilot-scale purification |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JP-KeebioFC |
| Instrument Type | Mixed-Mode Fraction Collector |
| Collection Mechanism | Suspended X-Y Robotic Movement |
| Display | 8.5-inch HD Touchscreen |
| Tube Capacity Options | 100 × 12 mL (standard), 16 × 100 mL (optional), 36 × 50 mL (optional), 169 × 5 mL (optional) |
| Timing Range | 1 s – 999 h 59 min 59 s |
| Drop Counting Range | 1–9999 drops |
| Peak Threshold Range | 1–200 mV |
| Programmable Segments | 1–10 segments |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 385 × 390 × 310 mm |
| Weight | 14 kg |
| Continuous Operation Time | >200 hours |
| Data Retention (Power Loss) | Up to 10 years |
| Valve Actuation | 12 V DC Solenoid |
| Tube Tray Design | Modular Square Rack with Integrated Waste Channel |
| Corrosion Resistance | Compatible with aqueous and common organic solvents (e.g., methanol, acetonitrile, chloroform, ethyl acetate) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | DBS-160 |
| Fraction Collection Modes | Time-based, Drop-counting, Peak-triggered |
| Max. Tube Capacity | 160 × 5 mL |
| Time Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Peak Threshold Range | 0–100 mV |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation | >200 hours |
| Display | Large Backlit Blue-Membrane Chinese LCD |
| Tube Rack | Circular, Digitally Labeled (001–160) |
| Housing Material | ABS Plastic (Injection-Molded, Closed-Structure) |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-160 |
| Collection Method | Time-Based |
| Tube Capacity | 5 mL per tube |
| Max. Tube Count | 160 |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Housing Material | ABS (high-impact, solvent-resistant grade) |
| Display | Backlit Chinese-language LCD with menu-driven interface |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| External Trigger Interface | RS-232 (DB9 COM port) for synchronized operation with peristaltic pumps |
| Brand | Jiapeng |
|---|---|
| Model | BS-100A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | Large Blue-backlit Chinese LCD with Menu-driven Interface |
| Housing Material | ABS Plastic (Injection-molded, Closed-loop Design) |
| Panel Angle | 35° Ergonomic Tilt |
| Tube Rack | Circular, Digitally Labeled (1–100), Interchangeable with Standard 12-mL Tube Formats |
| Valve Type | Keebio Fluid Shut-off Solenoid Valve |
| Compatibility | External Trigger via RS-232 COM Port (for Synchronization with Peristaltic Pumps) |