| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio600 |
| Detection Method | Absorbance Photometry |
| Wavelength | 600 nm |
| Wavelength Accuracy | ±4.0 nm |
| Spectral Bandwidth | 8 nm |
| Absorbance Range | −0.3 to 3.0 A |
| Absorbance Accuracy | ±0.005 A (0–0.5 A), ±0.01 A (0.5–1.0 A) |
| Absorbance Repeatability | 0.002 A |
| Sample Volume | ≥200 µL |
| Light Source | Long-life LED (Cold White) |
| Detector | Silicon Photodiode |
| Display | 7-inch Color Touchscreen (1024 × 600) |
| Data Storage | Internal (128 MB) + USB/SD Card Export |
| Connectivity | USB-B |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V / 3 A |
| Dimensions (W×D×H) | 290 × 260 × 100 mm |
| Weight | 2.15 kg |
| Brand | Keebio |
|---|---|
| Model | MR200 |
| Type | Automated Absorbance Microplate Reader |
| Wavelength Range | 340–800 nm |
| Absorbance Range | 0.000–4.000 A |
| Accuracy | ≤ ±0.005 A or ±0.2% T |
| Light Source | High-Stability LED (20,000 h lifetime) |
| Optical Path | 8-Channel Simultaneous Detection |
| Plate Format | Standard 96-well (flat/U/V-bottom compatible) |
| Read Speed | ≤3 sec/plate (single wavelength), ≤6 sec/plate (dual wavelength) |
| Filter Positions | 10 (standard: 405, 450, 492, 630 nm |
| Bandwidth | ≤8 nm (FWHM) |
| Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Repeatability | ≤0.2% (A) or ≤0.2% T |
| Drift | ≤±0.002 A or ≤0.5% T / 10 min |
| Data Storage | 2,000 plates (96-well), ≥500 assay protocols |
| Interface | USB 2.0, RS232, parallel printer port, USB mouse/keyboard support |
| Display | 7-inch color TFT LCD touchscreen |
| Operating Environment | 5–40 °C, 15–80% RH |
| Dimensions | 475 × 350 × 210 mm |
| Net Weight | 10 kg |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-5000PRO |
| Detection Method | Absorbance (UV-Vis) |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Absorbance Range | 0–4.0 A |
| Absorbance Linearity | ±2% (0–2.5 A) |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 ± 0.4 nm |
| Stray Light | ≤0.05% at 220 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Absorbance Precision | SD < 0.003 A or CV < 1.0% (at 450 nm) |
| Absorbance Accuracy | ±(1.0% + 0.003 A) for 0–2.0 A |
| Plate Formats | 96-well and 384-well microplates |
| Cuvette Compatibility | 1-cm standard quartz/glass cuvettes |
| Incubation Temperature Range | Ambient +5°C to 45°C (±0.5°C uniformity at 37°C) |
| Reading Time | 10 s per 96-well plate, 20 s per 384-well plate |
| Plate Shaking | Linear shaking with low/medium/high speed settings |
| Display | 10-inch color capacitive touchscreen |
| Interfaces | RS232, USB |
| Dimensions (W×D×H) | 503 × 376 × 330 mm |
| Weight | 15 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |