| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-3000 |
| Detection Principle | UV Absorbance (214 nm, 254 nm, 280 nm, 340 nm) |
| Optical Path Length | 4 mm |
| Flow Cell Volume | 80 µL |
| Minimum Detectable Concentration | 48 µg/mL (at 280 nm, for BSA) |
| Absorbance Range | 0.05 A to 2 A (6 selectable ranges) |
| Wavelength Accuracy | ±1 nm |
| Data Interface | USB + RS-232 (COM) |
| Software | Proprietary chromatographic data acquisition & analysis suite (Windows XP/7/10 compatible) |
| Column Compatibility | Standard GE Healthcare/AKTA-compatible fittings (1/16" OD tubing, female Luer lock inlet/outlet) |
| Compliance | Designed per ISO/IEC 17025-relevant instrumentation requirements for analytical lab use |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-97-1 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell Path Length | 3 mm |
| Flow Cell Volume | 100 µL |
| Minimum Detectable Concentration | 48 µg/mL |
| Absorbance Range | 0.05 A – 2 A (7 ranges) |
| Transmittance Range | 0–100% T |
| Display | High-clarity LED, triple-channel OD readout |
| Control System | Embedded microcomputer chip |
| Compatibility | GE/AKTA-compatible column fittings |
| Gradient Type | Linear |
| Max. System Pressure | 3 MPa |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Brand | Jipeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2880Plus |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 3096(H) × 2080(V), 6.4 Megapixels |
| Bit Depth | 16-bit |
| Dynamic Range | 4.5 OD |
| CCD Sensor Size | 1/2.5" |
| Detection Sensitivity | ≤ 0.01 ng double-stranded DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | ≥ 56 dB |
| Lens | Motorized optical zoom lens, 8–48 mm, 6× zoom, f/1.2 aperture |
| Transmission UV Source | 302 nm (standard), optional 254 nm / 365 nm reflectance UV |
| Transilluminator Area | 210 × 260 mm (UV), 210 × 300 mm (blue/white light panel) |
| Filter | Standard 590 nm emission filter, compatible with EB, SYBR Safe, GoldView, and other common nucleic acid stains |
| Software | JP-GEL 1D Image Analysis Suite |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 380 × 430 × 730 mm |
| Weight | 18.1 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | DHL-A |
| Pump Type | Dual-Channel Peristaltic Pump |
| Flow Rate Range | 2 × (0.6–900) mL/h |
| Speed Range | 0–65 rpm |
| Speed Resolution | 0.1 rpm |
| Maximum Pressure | ≥3 kg/cm² |
| Tube Compatibility | Ø1.2×3 mm, 3×5 mm |
| Quantitative Volume Range | 0.01–99990 mL |
| Flow Calibration Range | 1–300% |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 125×150×180 mm |
| Weight | 1.55 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-9 |
| Instrument Type | Darkroom Transilluminator |
| UV Wavelength | 366 nm |
| UV Lamp Quantity | 4 × 8 W |
| UV Transmission Area | 200 × 80 mm |
| UV Filter Dimensions | 200 × 50 mm |
| Visible Light Lamp | 6 W (1 unit) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| External Dimensions | 320 × 220 × 310 mm |
| Compliance | Designed for GB/T 5750.12–2006 and GB 5749–2006 water quality testing protocols |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HL-2F |
| Pump Type | Dual-Channel Peristaltic Pump |
| Flow Rate Range | 2 × (0.5–900) mL/h |
| Speed Range | 0–65 rpm (dispensing mode: 0–60 rpm) |
| Pressure Rating | 3 kg/cm² |
| Display | Gold LED Digital Screen |
| Pump Head | Dual 6-Roller with PTFE Housing |
| Tubing Compatibility | 1.2×3 mm and 3×5 mm ID/OD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 125 × 150 × 180 mm |
| Weight | 1.5 kg |
| Direction Control | Bidirectional (Forward/Reverse) |
| Enclosure Material | ABS Plastic (Injection-Molded, Full-Enclosure Design) |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | FWA-201B |
| Instrument Type | Darkroom-style |
| Wavelength Options | Dual-band (254 nm & 365 nm) |
| UV Filter Dimensions | 200 × 50 mm |
| UV Lamp Power | 16 W |
| Input Voltage | AC 220 V ± 10%, 50/60 Hz |
| UV Intensity at 20 cm | ≥20 µW/cm² |
| Built-in Rechargeable Li-ion Battery | 4800 mAh |
| Display | LCD with Chinese interface |
| Image Storage Capacity | ≥5000 frames |
| Dimensions (L×W×H) | 310 × 200 × 300 mm |
| Weight | 3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-2000 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell Path Length | 3 mm |
| Flow Cell Volume | 100 µL |
| Minimum Detectable Concentration | 48 µg/mL |
| Absorbance Range | 0.05 A – 2 A |
| Transmittance Range | 0–100 %T |
| Display | Triple-channel LED readout of OD values (A254, A280, A340 or user-selectable) |
| Microprocessor Control | Embedded MCU with real-time analog signal processing |
| Compatibility | Standard Luer-lock and GE/AKTA-compatible column interfaces |
| Gradient Type | Linear gradient support |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | KEEBIO-HE120 |
| Gel Dimensions | 60×60 mm, 120×60 mm, 120×120 mm (max) |
| Sample Capacity | Up to 2 gels simultaneously |
| Voltage Input | 220 V AC |
| Buffer Volume Capacity | 660 mL |
| Electrode Material | 99.95% pure platinum |
| Housing Material | Injection-molded polycarbonate |
| Weight | 1.2 kg |
| External Dimensions | 310 × 155 × 70 mm |
| Comb Options | 8 types (1.0 mm, 1.5 mm, 2.0 mm thickness |
| Max Loading Volume per Well | 15–550 µL (depending on comb configuration) |
| Gel Casting | Compatible with multi-purpose casting trays (no tape sealing required) |
| Thermal Stability of Casting Tray | Up to 135 °C |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZF-108 |
| Price Range | USD 280–700 |
| Instrument Type | Darkroom-style |
| Wavelength Options | 254 nm and 365 nm |
| UV Filter Size | 200 × 50 mm |
| UV Lamps | 2 × 20 W |
| Power Consumption | 20 W |
| Display | LCD with Chinese interface |
| Control System | Microcontroller-based |
| UV Lamp Angle | Adjustable |
| UV Intensity at 20 cm | ≥20 µW/cm² |
| Built-in Rechargeable Battery | 4800 mAh |
| Dimensions (L×W×H) | 310 × 200 × 300 mm |
| Weight | 3 kg |
| Compliance | NY/T 1257–2006 (Detection of Fluorescent Substances in Edible Fungi) |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | KEEBIO-VE180 |
| Instrument Type | Vertical Electrophoresis Apparatus |
| Gel Dimensions (Hand-cast) | 83 × 73 mm |
| Gel Thickness Options | 0.75 mm / 1.0 mm / 1.5 mm (default: 1.0 mm) |
| Max Gel Capacity | 2 gels (standard), upgradable to 4 gels (optional) |
| Voltage Input | 220 V AC |
| External Dimensions | 170 × 120 × 120 mm |
| Electrode Material | 99.95% Pure Platinum |
| Weight | 2.56 kg |
| Compliance | CE-marked design principles |
| Sample Capacity | 1 gel unit per run (dual-gel configuration supported) |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | HE260 |
| Electrophoresis Tank Type | Horizontal |
| Max Gel Dimensions (mm) | 245 × 250 / 245 × 125 |
| Max Sample Capacity | 350 samples per run |
| Max Voltage | 500 V |
| Buffer Volume Capacity | 1660 mL |
| Gel Casting Volume | 350–400 mL (245×250 mm) or 175–200 mL (245×125 mm) |
| Dimensions (L×W×H, mm) | 440 × 280 × 130 |
| Weight | 3 kg |
| Electrode Material | 99.99% Pure Platinum |
| Adjustable Leveling Feet | Yes |
| Replaceable Electrode Assembly | Yes |
| Comb Options | 1.0 mm & 1.5 mm thickness |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio3009 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Isocratic & Step Gradient |
| UV Detector Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Accuracy | ±1.2% |
| UV Detection Range | –6 to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Maximum System Pressure | 3 bar |
| Conductivity Range | 0.001–400.00 mS/cm |
| Accuracy | ±2% (with temperature compensation) |
| Solvent Compatibility | Aqueous buffers, common chromatographic mobile phases, and biocompatible solutions used in protein purification |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-6 |
| Instrument Type | Benchtop |
| Wavelength Modes | 254 nm and 365 nm (dual-band) |
| UV Filter Dimensions | 200 × 50 mm |
| UV Lamp Power | 8 W × 2 |
| Visible Light Lamp | 4 W × 1 |
| UV Intensity | 20 µW/cm² at 20 cm distance |
| Input Voltage | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 270 × 280 × 270 mm |
| Weight | 1.2 kg |
| Compliance | JJF 1936–2021 (National Verification Regulation for UV Analyzers) |
| Enclosure Material | High-strength, eco-friendly ABS polymer |
| UV Lamp Angle | Adjustable |
| Regulatory Status | Domestic (PRC) |
| Manufacturer Role | Authorized Distributor |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K300 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 4/3" |
| Pixel Size | 5.4 µm × 5.4 µm |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs ambient) |
| Quantum Efficiency | >75% |
| Lens Aperture | f/0.95 Fixed-Focus Macro Lens |
| White Light Source | Top-Mounted Uniform LED Panel |
| Minimum Detectable DNA | 0.01 ng (EB-stained) |
| Dark Current | <0.0005 e⁻/pixel/s |
| SNR | ≥56 dB |
| Dual Imaging Area | 9.5 × 9.5 cm & 12.5 × 12.5 cm |
| Power Input | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Keebio |
|---|---|
| Model | MiniES |
| Type | Horizontal Submarine Electrophoresis Apparatus |
| Gel Tray Dimensions | 120 × 60 mm and 60 × 60 mm (included) |
| Max Gel Size | 126 × 126 mm |
| Buffer Capacity | 230 mL |
| Output Voltage Options | DC 35 V / 50 V / 100 V (fixed, user-selectable) |
| Timer Range | 1–99 min |
| Input Power | AC 100–240 V, 50–60 Hz |
| Power Consumption | 40 W |
| Chamber Internal Dimensions (W×D×H) | 110 × 121 × 43 mm |
| Housing Material | High-Temperature-Resistant Alloy Polymer |
| Overall Dimensions (W×D×H) | 205 × 140 × 60 mm |
| Weight | 0.8 kg |
| Safety | Lid-Interlocked Auto-Shutoff Circuit |
| Included Comb Sets | 3 × 1 × 22 mm, 5.6 × 1 × 12 mm, 3 × 1 × 18 mm, 5.6 × 1 × 10 mm |
| Brand | Jiapeng |
|---|---|
| Model | BS-16A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 16 × 100 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 460 mm |
| Weight | 6.5 kg |
| Data Retention | 10 years after power loss |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS polymer (injection-molded, solvent-resistant grade) |
| Panel Angle | 35° ergonomic tilt |
| Tube Tray | Circular, digitally labeled (01–16), interchangeable with standardized 16-position racks |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic or piston-driven pumps |
| Valve Type | Keebio precision fluid shut-off valve (standard) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | Nano-600 |
| Sample Volume | 0.5–2.0 µL |
| Analytes | dsDNA, RNA, BSA |
| DNA Detection Range | 2–17,500 ng/µL (dsDNA) |
| Protein Detection Range | 0–440 mg/mL (BSA) |
| Wavelength Accuracy | ±1 nm |
| Measurement Time | ≤5 s |
| Wavelength Range | 185–910 nm |
| Absorbance Range (10-mm equivalent) | 0.02–300 A |
| Absorbance Precision | ±0.002 A |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Optical Path Lengths | 0.05 mm, 0.2 mm, 1.0 mm (auto-switching) |
| Light Source | Xenon flash lamp (rated lifetime ≥10 years) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm FWHM (at Hg 546 nm) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 270 × 210 × 196 mm |
| Weight | 3.5 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZF1-II |
| Instrument Type | Darkroom-style |
| Wavelength Modes | Multi-wavelength |
| UV Transmission Wavelength | 302 nm |
| UV Reflection Wavelengths | 254 nm, 365 nm |
| Filter Type | Transparent short-wave cutoff filter |
| UV Lamp Count | 10 |
| UV Filter Dimensions | 200 × 150 mm |
| UV Transmission Area | 200 × 150 mm |
| UV Lamp Power | 8 W per lamp |
| Input Power | AC 220 V, 50/60 Hz |
| White Light Source | 40 W incandescent lamp |
| UV Intensity at 20 cm | 20 µW/cm² |
| Cut-out Tool Kit | 1 gel-cutting blade with 4 replaceable tips |
| Darkroom Dimensions (L×W×H) | 375 × 280 × 380 mm |
| Net Weight | 4.88 kg |
| Brand | Keebio |
|---|---|
| Model | MT2500 |
| Type | Benchtop Multi-Sample Vortex Mixer |
| Drive | Brushless DC Motor |
| Operating Mode | Continuous |
| Speed Range | 500–2500 rpm (±10 rpm setting resolution) |
| Oscillation Amplitude | 4 mm horizontal circular motion |
| Display | Digital LCD (simultaneous speed and timer readout) |
| Timer Range | 1 min – 99 h 59 min |
| Power Supply | AC 100–230 V, 50/60 Hz, 100 W |
| Dimensions (W×D×H) | 240 × 420 × 430 mm |
| Net Weight | 20 kg |
| Construction | Anodized aluminum housing |
| Sample Capacity | Up to 50 tubes (configurable via interchangeable foam tube holders) or up to 4 standard microtiter plates (96-well or 384-well format) |
| Compliance | CE-marked, RoHS-compliant, designed for GLP-aligned laboratory environments |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-7 |
| Instrument Type | Darkroom-style |
| Wavelengths | 254 nm & 365 nm (dual-band) |
| Visible Light Source | 4 W white LED |
| UV Transillumination Area | 200 × 50 mm |
| UV Lamp Configuration | Two 8 W low-pressure mercury lamps (254 nm & 365 nm) |
| UV Filter Dimensions | 200 × 50 mm |
| Adjustable UV Lamp Angle | Yes |
| Viewing Window | UV-blocking acrylic (99% UVC/UV-A attenuation) |
| Operating Distance | 20 cm |
| UV Intensity at 20 cm | 20 µW/cm² |
| Power Input | AC 220 V, 50/60 Hz |
| External Dimensions (L×W×H) | 280 × 330 × 330 mm |
| Internal Cavity Dimensions | 280 × 245 × 220 mm |
| Net Weight | 2.65 kg |
| Compliance | JJF 1936–2021 (National Verification Regulation for UV Analyzers) |
| Patents | ZL201920792756.2, ZL202221777391.4, ZL202222383825.9 |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio1000 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 185–910 nm |
| Cuvette Mode (OD600) | 600 ± 8 nm |
| Sample Volume | 0–2.0 µL |
| Optical Path Lengths | 1.0 / 0.5 / 0.1 / 0.05 / 0.02 mm (auto-switching) |
| Light Source | Xenon flash lamp (≥10 yr lifetime) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm (FWHM at Hg 546 nm) |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.002 A |
| Absorbance Range (10-mm equivalent) | 0–780 A |
| OD600 Range | 0–4 A |
| Measurement Time | ≤5 s |
| dsDNA Quantification Range | 0–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Data Export | USB port, SD-RAM card |
| Optional fluorescence module (Ex | 460 nm, Em: 525 nm) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-5 |
| Instrument Type | Portable (Handheld) |
| Wavelength Options | 254 nm & 365 nm (or 302 nm) |
| UV Filter Dimensions | 200 × 50 mm |
| UV Lamps | 8 W × 2 |
| UV Intensity | ≥20 µW/cm² at 20 cm distance |
| Input Power | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 280 × 80 × 120 mm |
| Weight | 0.7 kg |
| Compliance | JJF 1936–2021 (National Verification Regulation for UV Analyzers) |
| Patents | ZL202221777391.4, ZL202222383825.9 |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-600S |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 3–600 V |
| Current Range | 4–800 mA |
| Power Range | 1–300 W |
| Display Resolution | 0.1 V / 0.1 mA / 0.1 W |
| Timer Range (Single Step) | 1–9999 min |
| Timer Range (Multi-Step, 10 steps × 10 programs) | 1–999 min per step |
| Output Ports | 4 independent DC outputs |
| Input | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 250 × 230 × 90 mm |
| Weight | 1.5 kg |
Show next