- All
- Favorite
- Popular
- Most rated
| Brand | Jipeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2880Plus |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 3096(H) × 2080(V), 6.4 Megapixels |
| Bit Depth | 16-bit |
| Dynamic Range | 4.5 OD |
| CCD Sensor Size | 1/2.5" |
| Detection Sensitivity | ≤ 0.01 ng double-stranded DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | ≥ 56 dB |
| Lens | Motorized optical zoom lens, 8–48 mm, 6× zoom, f/1.2 aperture |
| Transmission UV Source | 302 nm (standard), optional 254 nm / 365 nm reflectance UV |
| Transilluminator Area | 210 × 260 mm (UV), 210 × 300 mm (blue/white light panel) |
| Filter | Standard 590 nm emission filter, compatible with EB, SYBR Safe, GoldView, and other common nucleic acid stains |
| Software | JP-GEL 1D Image Analysis Suite |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 380 × 430 × 730 mm |
| Weight | 18.1 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K300 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 4/3" |
| Pixel Size | 5.4 µm × 5.4 µm |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs ambient) |
| Quantum Efficiency | >75% |
| Lens Aperture | f/0.95 Fixed-Focus Macro Lens |
| White Light Source | Top-Mounted Uniform LED Panel |
| Minimum Detectable DNA | 0.01 ng (EB-stained) |
| Dark Current | <0.0005 e⁻/pixel/s |
| SNR | ≥56 dB |
| Dual Imaging Area | 9.5 × 9.5 cm & 12.5 × 12.5 cm |
| Power Input | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K900 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD (0–65535 grayscale) |
| Pixel Binning Options | 1×1, 2×2, 3×3, 4×4, 6×6, 8×8 |
| Detection Sensitivity | <20 pg double-stranded DNA stained with ethidium bromide |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens Aperture | F/0.95 fixed-focus lens |
| CCD Sensor | Sony IMX533CLK-D, 4/3″ format |
| Cooling Temperature | −45°C (ΔT ≈ −65°C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Quantum Efficiency | >75% |
| Dark Current | <0.0005 e⁻/pixel/s |
| Transmission UV Source | 302 nm (standard), optional 254 nm / 365 nm reflectance UV |
| White Light Transilluminator | Integrated drawer-style uniform panel (200 × 200 mm) |
| Excitation Light Sources | UV transillumination (302 nm), optional UV reflectance (254/365 nm), blue/red/green LED fluorescence modules |
| Filter Wheel | Motorized 5-position (standard), optional 10-position |
| Imaging Area | Dual-stage—9.5 × 9.5 cm and 12.5 × 12.5 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K600 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | >4.0 OD (4.8 OD typical) |
| CCD Sensor Size | 4/3" (SONY IMX533CLK-D) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs ambient) |
| Lens Aperture | f/0.95 fixed-focus macro lens |
| Detection Sensitivity | <20 pg double-stranded DNA stained with ethidium bromide |
| Signal-to-Noise Ratio | ≥56 dB |
| White Light Transmission Area | 200 × 200 mm |
| UV Transillumination | 300 nm (transmission), optional 254/365 nm (reflection) |
| Filter Wheel | 5-position motorized (optional 10-position) |
| Standard Emission Filter | 590 nm |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3300Plus |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD (0–65535 grayscale) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Sensor Format | 4/3-inch Sony IMX533CLK-D |
| Cooling Temperature | −45 °C (ΔT ≤ −65 °C vs ambient) |
| Lens Aperture | f/0.95 fixed-focus lens |
| Signal-to-Noise Ratio | ≥56 dB |
| Quantum Efficiency | >75% |
| White Light Source | Top-mounted uniform LED transilluminator |
| Dual Imaging Area | 9.5 × 9.5 cm & 12.5 × 12.5 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3900Plus |
| Imaging Type | Multicolor Fluorescence & Chemiluminescence Gel Imager |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 4/3" (SONY IMX533CLK-D) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs. ambient) |
| Quantum Efficiency | >75% |
| Lens | F/0.95 Fixed Focus (optional F/0.8) |
| Optical Zoom | 8–48 mm (6×) |
| Detection Sensitivity | ≥0.02 ng Protein (Western blot), ≥0.05 ng DNA (ethidium bromide-stained) |
| Signal-to-Noise Ratio | ≥56 dB |
| Transmission UV Sources | 300 nm (standard), 254/365 nm (optional reflectance) |
| UV Transilluminator Area | 200 × 200 mm |
| White Light Transmission Panel | Uniform LED-based, integrated |
| Filter Wheel | Motorized 5-position (optional 10-position), with standard bandpass filters at 535, 590, 605, and 699 nm |
| Imaging Area Options | 9.5 × 9.5 cm and 12.5 × 12.5 cm (dual-stage drawer platform) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K4600Plus |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 3000 × 3000 (9 MP) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 4/3-inch |
| Detection Sensitivity | 4.8 OD at 16-bit grayscale (0–65,535) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Motorized Optical Zoom 8–48 mm (6× zoom ratio) |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs. ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning Options | 1×1 to 8×8 |
| Quantum Efficiency | >75% |
| Dark Current | <0.0005 e⁻/pixel/s |
| White Light Source | Top-mounted, uniform illumination |
| Imaging Area | 10 cm × 8.8 cm |
| Sample Stage | Motorized drawer-type, 11 cm × 11 cm active area |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 295 × 245 × 450 mm |
| Weight | 5 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3900 |
| Imaging Modality | Chemiluminescence, Fluorescence (UV/Blue/Green/Red), White Light Transmission & Reflection |
| CCD Sensor | Sony IMX533CLK-D, 4/3-inch format, 3000 × 3000 (9 MP) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Bit Depth | 16-bit (0–65,535 grayscale) |
| Dynamic Range | >4.8 OD |
| Cooling Temperature | −45 °C (ΔT ≤ −65 °C vs ambient) |
| Quantum Efficiency | >75% |
| Lens | Computar F/0.95, 8–48 mm motorized zoom lens |
| Signal-to-Noise Ratio | ≥56 dB |
| Detection Sensitivity | Protein ≥0.02 ng, DNA ≥0.05 ng (chemiluminescent substrates) |
| Dark Current | <0.0005 e⁻/pixel/s |
| Transmission UV Sources | 302 nm (standard), 254 nm & 365 nm (optional reflectance) |
| UV Transilluminator | 200 × 200 mm, high-intensity |
| White Light Source | Top-mounted, uniform LED panel with >90% homogeneity |
| Sample Stage | Dual-position drawer-style platform (9.5 × 9.5 cm and 12.5 × 12.5 cm imaging areas) |
| Filter Wheel | Motorized 5-position (standard), optional 10-position |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-288 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5 MP (3096 × 2080 pixels) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.5 OD |
| CCD Sensor Size | 1/2.5" |
| Minimum Detectable DNA | 0.01 ng (EB-stained dsDNA) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Motorized High-Transmission Zoom Lens (Computar, f/1.2, 8–48 mm) |
| Transmission UV Source | 300 nm (210 × 260 mm area) |
| Reflected UV Sources | 254 nm & 365 nm |
| Blue/White Light Transilluminator | 210 × 300 mm |
| Standard Emission Filter | 590 nm |
| Software | JP-GEL 1D Image Analysis Suite |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 435 × 390 × 760 mm |
| Weight | 19.68 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2880 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5 MP (3096 × 2080) |
| Bit Depth | 16-bit |
| Dynamic Range | >4.5 OD |
| CCD Sensor Size | 1/2.5" |
| Minimum Detectable DNA | 0.01 ng (EB-stained dsDNA) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Motorized High-Transmission Zoom Lens (Computar, 8–48 mm, f/1.2) |
| Transmission UV Source | 302 nm (210 × 260 mm area) |
| Optional Blue/White Light Transilluminator | 210 × 300 mm |
| Standard Emission Filter | 590 nm |
| Software | JP-GEL 1D Image Analysis Suite |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 380 × 430 × 730 mm |
| Weight | 18.1 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | JP-K4600 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 4/3-inch (SONY IMX533CLK-D) |
| Detection Sensitivity | ≥0.02 ng for Protein |
| Signal-to-Noise Ratio | 56 dB |
| Lens | Fixed F/0.95 lens (optional F/0.8), 8–48 mm optical zoom (6× zoom ratio) |
| Sample Stage | 11 × 11 cm illuminated platform with anti-scatter design |
| Cooling Temperature | −45 °C (ΔT = −65 °C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning | 1×1 to 8×8 |
| Dark Current | <0.0005 e⁻/pixel/s |
| White Light Source | Top-mounted, uniform illumination |
| Image Area | 10 × 8.8 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 295 × 245 × 450 mm |
| Weight | 5 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3600 |
| Instrument Type | Chemiluminescent Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | >4.8 OD |
| CCD Sensor Size | 4/3" |
| Detection Sensitivity | Protein ≥0.02 ng, DNA ≥0.05 ng (EB-stained dsDNA ≤20 pg) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens Aperture | f/0.95 Fixed Focus Lens |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning Options | 1×1 to 8×8 |
| White Light Transilluminator | Uniform Top-Illumination Panel |
| UV Transilluminator | 300 nm (transmission), optional 254/365 nm (reflection) |
| UV Tray Size | 200 × 200 mm |
| Filter Wheel | 5-position motorized (optional 10-position) |
| Standard Emission Filter | 590 nm |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-388Plus |
| CCD Resolution | 20 MP (5472 × 3660) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.5 OD |
| CCD Sensor Size | 1-inch |
| Signal-to-Noise Ratio | ≥42 dB |
| Lens | Motorized Zoom Lens, 8–48 mm (6× optical zoom), f/1.2 aperture |
| UV Excitation | Transmitted 300 nm |
| UV Transilluminator Area | 210 × 260 mm |
| Blue/White Light Converter Plate | 210 × 300 mm |
| Standard Emission Filter | 590 nm |
| Software | JP-GEL 1D & JP Analysis 3.3 |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 440 × 430 × 460 mm |
| Weight | 19 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K3600Plus |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 4/3" |
| Detection Sensitivity | ≥0.02 ng Protein, ≥0.05 ng DNA |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Motorized Optical Zoom 8–48 mm (6×), f/0.95 Fixed Aperture (optional f/0.8) |
| Cooling Temperature | −45 °C (ΔT ≤ −65 °C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning Modes | 1×1 to 8×8 |
| Transmission White Light Panel | Uniform LED Illuminator |
| UV Transilluminator | 200 × 200 mm, 300 nm (transmission), optional 254/365 nm reflectance |
| Filter Wheel | 5-position motorized (optional 10-position), standard F590 emission filter |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K3300 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD (0–65,535 grayscale levels) |
| Pixel Binning Options | 1×1, 2×2, 3×3, 4×4, 6×6, 8×8 |
| Detection Sensitivity | ≥0.02 ng Protein |
| Signal-to-Noise Ratio | 56 dB |
| Lens Aperture | f/0.95 Fixed Focus Lens |
| CCD Sensor | Sony IMX533CLK-D, 4/3″ format |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs. ambient) |
| Quantum Efficiency | >75% |
| Pixel Size | 5.4 µm × 5.4 µm |
| White Light Transilluminator | Uniform top-mounted LED source |
| Dual Imaging Area | 9.5 × 9.5 cm and 12.5 × 12.5 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
Show next