BrandJiapeng
OriginShanghai, China
ModelGHX-IV
Light Source TypeMercury Lamp
Irradiation ModeInternal Illumination
Power Range100–1200 W (continuously adjustable)
Lamp OptionsMercury (300/500/1000 W), Xenon (300/500/1000 W), Metal Halide (500 W)
Sample Capacity8 parallel positions
Reaction Vessel Options250 / 500 / 1000 / 2000 / 3000 mL glass reactors
Quartz Tube Options30 mL or 50 mL
Filter Configuration16 UV/optical bandpass filters, dual 8-position filter holders
CoolingDual-layer quartz cold well (Φ70 × 380 mm), low-temperature circulating chiller (–20 °C to 100 °C, >1000 W cooling capacity)
StirringMagnetic stirring, 0–1800 rpm (8-channel synchronized), temperature control up to 300 °C
Timer0–999 min (digital microprocessor controller)
SafetyRadiation-shielded dark chamber with UV-blocking insertable shutter, hinged observation window, ventilation ports, and integrated cooling fan
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiapeng
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelBSZ-8
Light Source TypeMercury Lamp
Irradiation ModeInternal Illumination
Sample Capacity8 positions
Quartz Reaction Tube Options30 mL or 50 mL (customizable up to 200 mL)
Quartz Cold Finger DimensionsΦ70 × 380 mm
Stirring Speed Range0–1800 rpm (continuously adjustable)
Rotation Cycle per Tube1 s – 24 h (continuously adjustable)
Filter Configuration16 standard optical filters + 2 dedicated 8-position filter holders
Light Incidence GeometryPerpendicular transmission through filters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiapeng
OriginShanghai, China
ModelGHX-V
Light Source TypeMercury Lamp
Irradiation ModeInternal Illumination
Power Control Range100–1200 W (continuously adjustable)
Lamp Options300/500/1000 W Mercury Lamp (selectable), 300/500/1000 W Xenon Lamp (selectable), 500 W Metal Halide Lamp
Sample Capacity8 parallel positions
Quartz Tube Volume30 mL or 50 mL (customizable)
Quartz Cold FingerΦ70 × 380 mm
Reaction Vessel Options250 / 500 / 1000 / 2000 / 3000 mL
Filter Wheel16-position, dual 8-slot filter holder
Filter Transmission GeometryPerpendicular incidence
Stirring Speed (per tube)0–1800 rpm (stepless)
Rotation Period per Tube0–9999 s (stepless)
Magnetic Stirrer Temp. RangeAmbient to 300 °C
Timer RangeUp to 999 min
Cryogenic CirculatorCooling Capacity >1000 W, Temp. Control Range: −20 to 100 °C