- All
- Favorite
- Popular
- Most rated
| Brand | MAPADA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.5 nm |
| [Brand | MPB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Compliance | ISO/IEC 17025-compatible validation protocols supported] |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | PV1 |
| Price Range | USD 1,400 – 2,800 |
| Optical System | Single-beam |
| Detector Type | Photocell |
| Automation Level | Automatic Wavelength Scanning |
| Wavelength Range | 320 – 1050 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.8 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Single-beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Setting | Motorized Automatic |
| Display | 320 × 240 pixel LCD (5-inch) |
| Measurement Modes | Transmittance (T), Absorbance (A), Concentration (C), Energy (E) |
| Scan Speed Options | High/Medium/Low (up to 3800 nm/min) |
| Light Sources | Imported long-life deuterium lamp and tungsten-halogen lamp |
| Sample Compartment Dimensions | Accommodates cuvettes from 5 mm to 100 mm pathlength |
| Data Interface | USB port |
| Print Interface | Parallel port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions (W×D×H) | 590 × 420 × 260 mm |
| Net Weight | 20 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Setting | Motorized Auto-Scanning |
| Display | 128×64 Dot-Matrix LCD |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Light Sources | Imported Long-Life Tungsten Lamp & Deuterium Lamp |
| Sample Compartment Dimensions | Accommodates Cuvettes from 5 mm to 100 mm Pathlength |
| Interface | USB Port (Data Export), Parallel Port (Printer Output) |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Dimensions (W×D×H) | 490 × 360 × 240 mm |
| Net Weight | 14 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Domestic |
| Model | UV-670 |
| Price Range | USD 14,000–21,000 (FOB Shanghai) |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized Auto-Scanning |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 4.0 nm (selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Light Source | Imported Long-Life Deuterium Lamp & Tungsten-Halogen Lamp |
| Grating | Holographic, 1600 lines/mm |
| Measurement Modes | Absorbance (A), Transmittance (T), Concentration (C), Energy (E) |
| Data Interface | USB 2.0 + Parallel Printer Port |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Dimensions | 600 × 480 × 260 mm |
| Weight | 32 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Scanning Mode | Automatic |
| Housing Material | Reinforced Engineering Plastic with Aluminum Alloy Base Structure |
| Sample Compartment Design | Removable Front Panel, Damped Hinged Lid (0–120° Position Lock), Integrated Spill Drain Port |
| Brand | MPB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | M7 |
| Price Range | USD 9,800 – 14,000 |
| Optical Design | Dual-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190 – 1100 nm |
| Wavelength Scanning Mode | Motorized Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Setting | Automatic |
| Display | 128×64 Dot-Matrix LCD |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Light Sources | Imported Deuterium Lamp & Tungsten-Halogen Lamp |
| Data Interface | USB Port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions (W×D×H) | 490 × 360 × 240 mm |
| Net Weight | 14 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Scanning Speed | Up to 3800 nm/min (High Mode) |
| Photometric Range | 0–200% T, –4.0 to +4.0 A |
| Display | 320 × 240 pixel LCD (5-inch) |
| Interface | USB data output, Parallel port for printer |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions | 490 × 360 × 240 mm |
| Net Weight | 14 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Setting | Motorized Auto-Scanning |
| Display | 128×64 Dot-Matrix LCD |
| Photometric Modes | Transmittance (T%), Absorbance (A), Concentration (C), Energy (E) |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Data Interface | USB 2.0 |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions (W×D×H) | 490 × 360 × 240 mm |
| Net Weight | 14 kg |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | V-1200 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 325–1000 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Setting | Automatic |
| Display | 128 × 64 Dot-Matrix LCD (0.1 nm Resolution) |
| Absorbance Range | –0.3 to 3.0 A |
| Transmittance Range | 0–200% T |
| Light Source | Tungsten Halogen Lamp |
| Data Interface | USB Standard Port |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V / 50 Hz or 110 V / 60 Hz |
| Dimensions | 480 × 360 × 210 mm |
| Weight | 12 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UV-3000PC |
| Price Range | USD 4,200–7,000 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Setting | Motorized Auto-Scanning |
| Display | 320 × 240 LCD (5-inch), Graphical Interface |
| Measurement Modes | Transmittance (%T), Absorbance (A), Concentration (C), Energy (E) |
| Scan Speed Options | High / Medium / Low (up to 3800 nm/min) |
| Photometric Range | 0–200% T, –4.0 to +4.0 A |
| Light Sources | Imported long-life deuterium lamp (D₂) and tungsten-halogen lamp (W) |
| Lamp Monitoring | Real-time operational hour logging for both lamps |
| Sample Compartment | Accommodates cuvettes from 5 mm to 100 mm pathlength |
| Data Interface | USB 2.0 |
| Printer Interface | Parallel port (Centronics) |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Dimensions (W × D × H) | 490 × 360 × 240 mm |
| Net Weight | 14 kg |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Selection |
| Compliance | CE-marked, ISO/IEC 17025-compatible operation environment |
| Brand | MPD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Quasi-Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Display | 5-inch Capacitive Color Touchscreen |
| Sample Compartment Design | Removable Front Panel, Damped Hinged Lid (0–120° Position Hold), Integrated Spill Drain Port |
| Brand | MAPADA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | P9 |
| Price Range | USD 9,800 – 14,000 (FOB Shanghai) |
| Optical Design | Dual-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190 – 1100 nm |
| Wavelength Scanning Mode | Motorized Automatic |
| Spectral Bandwidth | Adjustable at 0.5, 1.0, 2.4, and 5.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | UV-6300 |
| Price Range | USD 7,000–10,000 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Scanning Speed | Up to 3800 nm/min (High Mode) |
| Display | 320 × 240 LCD (5-inch) |
| Data Interface | USB 2.0 |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions (W×D×H) | 590 × 420 × 260 mm |
| Net Weight | 26 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Single-Beam |
| Detector | Silicon Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Light Sources | Imported Deuterium Lamp & Tungsten-Halogen Lamp |
| Display | 128×64 Dot-Matrix LCD |
| Data Interface | USB 2.0 Standard Port |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions (W×D×H) | 490 × 360 × 240 mm |
| Net Weight | 14 kg |
| [Brand | MPB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Scanning | Motorized & Auto-Calibrated |
| Light Source | Pulsed Xenon Lamp (No Preheating Required)] |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | UV-6100S |
| Price Range | USD 7,000–10,000 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm (fixed) |
| Wavelength Setting | Automatic |
| Display | 320 × 240 LCD |
| Measurement Modes | Transmittance (T), Absorbance (A), Concentration (C), Energy (E) |
| Scan Speed Options | High/Medium/Low (up to 3800 nm/min) |
| Light Sources | Long-life imported tungsten lamp and deuterium lamp |
| Detector Type | Imported silicon photodiode |
| Interface | USB port for data export |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Dimensions | 590 × 420 × 260 mm |
| Net Weight | 26 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.3 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.3 nm |
| Stray Light | ≤0.05 %T at 220 nm and 360 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Setting | Motorized Auto-Scanning |
| Display | 320 × 240 LCD |
| Data Interface | USB Port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions (L×W×H) | 590 × 420 × 260 mm |
| Net Weight | 26 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Scanning Speed | Up to 3800 nm/min (High/Medium/Low Selectable) |
| Display | 320×240 LCD with Graphical Interface |
| Photometric Range | 0–200% T, –4.0 to +4.0 A |
| Light Sources | Imported Long-Life Deuterium Lamp & Tungsten-Halogen Lamp |
| Sample Compartment | Accommodates Cuvettes from 5 mm to 100 mm Pathlength |
| Data Interface | USB Port |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Dimensions | 590 × 420 × 260 mm |
| Net Weight | 20 kg |
Show next