| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Dual-Beam (Optical for Flame / Electronic for GF) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Detection Limit (Cu, Flame) | ≤0.002 μg/mL |
| Baseline Stability | Zero Drift ±0.002 Abs / 30 min |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-320 |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36% |
| Sensitivity | Cu 0.04 µg/mL per 1% absorption |
| Repeatability (RSD) | ≤0.9% (flame mode) |
| Detection Limit | Cu 0.007 µg/mL (flame mode) |
| Optional Accessory | Hydride Generation System |
| Brand | WITec |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Alpha 300 Access |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤0.2 cm⁻¹ |
| Spatial Resolution | Lateral 350 nm, Axial 800 nm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤±0.02 cm⁻¹ |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WITec Alpha 300R |
| Price | €500,000 |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 0.3 µm, Axial 0.8 µm (at 532 nm) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.02 cm⁻¹ |
| Brand | WITec |
|---|---|
| Origin | Germany |
| Model | Alpha 300S |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤0.2 cm⁻¹ |
| Spatial Resolution | Lateral 350 nm, Axial 800 nm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤±0.02 cm⁻¹ |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Model | alpha300 access |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤0.2 cm⁻¹ |
| Spatial Resolution | Lateral 350 nm, Axial 800 nm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤±0.02 cm⁻¹ |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | alpha300 R |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤0.2 cm⁻¹ |
| Spatial Resolution | Lateral 350 nm, Axial 800 nm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤±0.02 cm⁻¹ |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Model | cryoRaman |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution (lateral) | <400 nm |
| Minimum Wavenumber Shift | ±10 cm⁻¹ |
| Spectral Reproducibility | 0.02 cm⁻¹ |
| Brand | WITec |
|---|---|
| Origin | Germany |
| Manufacturer | WITec GmbH (Oxford Instruments Distribution Partner) |
| Instrument Type | Confocal Raman Microscope Integrated with SEM |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Wavenumber Accuracy | ≤ ±0.02 cm⁻¹ |
| Spatial Resolution | Lateral 360 nm, Axial 900 nm |
| Minimum Detectable Wavenumber | 100 cm⁻¹ |
| Sensitivity | SNR >20:1 for Si third-order Raman peak |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WQF-520 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WSSL-10 |
| Pricing | Available Upon Request |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | pH 3310 |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.005 (at 25 °C, for range –2.000–19.999) |
| mV Range | ±2000 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | –5.0 to 105.0 °C |
| Temp. Accuracy | ±0.1 °C |
| Automatic Temperature Compensation (ATC) | Yes |
| Calibration | 1-, 2-, or 3-point with auto-buffer recognition (DIN & NIST) |
| IP Rating | IP66/IP67 |
| Display | 7-segment LCD with large, high-contrast digits |
| Auto-read Delay | 15 s |
| Repeatability | < 0.02 pH |
| Battery Life | Up to 2500 hours (4 × AA alkaline) |
| Power Options | 4 × 1.5 V AA alkaline or 4 × 1.2 V NiMH rechargeable |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | photoLab 7600 VIS |
| Optical Design | Pseudo-double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automatic Wavelength Selection | Yes |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.003E (for E < 0.600), ±0.5% (for 0.600 < E < 2.00) |
| Brand | Wyoptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | EQ4000-1 |
| Spectral Range | 200–1100 nm |
| Detector | Toshiba TCD1304DG linear CCD |
| Optical Resolution | 0.035–4.88 nm FWHM (configurable via grating & slit) |
| System Sensitivity | 2 × 10⁸ |
| Single-Scan Dynamic Range | 1300:1 |
| Signal-to-Noise Ratio (SNR) | 400:1 |
| Full Dynamic Range | 3000:1 |
| Stray Light | < 0.1% @ 600 nm |
| A/D Resolution | 16-bit |
| Integration Time | 1 ms – 2 s |
| Slit Options | 5, 10, 25, 50, 100, 200 µm |
| EX Broadband Technology | 200–1100 nm coverage with variable-order suppression |
| Brand | X-Rite |
|---|---|
| Model | Ci7500 |
| Measurement Principle | D/8° (Diffuse Illumination / 8° Viewing) with Integrated Sphere |
| Wavelength Range | 360–750 nm |
| Optical Geometry | SCI & SCE Simultaneous |
| Aperture Options | 25 mm & 10 mm |
| Repeatability (White Tile) | ≤0.03 ΔE* uv (D65, UV Filter On) |
| Inter-Instrument Agreement (SCI) | ≤0.15 avg. ΔE CIELAB |
| Spectral Bandwidth | 10 nm |
| Reflectance Range | 0–200% |
| Measurement Cycle Time | <3 s |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TFPE |
| Pricing | Available Upon Request |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6431 |
| Detection Elements | K, Na, Ca |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Ca | 0.01 mmol/L |
| Response Time | ≤5 s |
| Repeatability | RSD ≤1.5% |
| Sample Flow Rate | 6–8 mL/min |
| Display | 7-inch capacitive touch LCD |
| Data Export | USB port & U-disk support |
| Safety Features | Flame-out protection & gas leakage alarm |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, 250 W |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6432 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Flow Rate | < 6 mL/min |
| Wavelength Accuracy | K/Li/Ca/Ba ≤ ±7 nm |
| Bandwidth (FWHM) | ≤ 15 nm for all elements |
| Background Transmittance | ≤ 0.5% |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz |
| Rated Power | 30 W |
| Display | 7-inch capacitive touch LCD |
| Data Storage | 10-point calibration curves (max), 200 sample records |
| Connectivity | USB port, U-disk export, cloud-enabled interface |
| Safety Features | Flame-out detection, gas leak alarm |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6440 |
| Detection Elements | K, Na, Li, Ca |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Li | 0.005 mmol/L |
| Ca | 0.01 mmol/L |
| Response Time | <8 s |
| Repeatability | RSD ≤1.5% |
| Nebulization Flow Rate | 6–8 mL/min |
| Display | 7-inch capacitive touch LCD |
| Safety Features | Flame-out protection, gas leakage alarm |
| Data Interface | USB port, U-disk export, PC connectivity |
| Cloud Connectivity | Yes |
| Calibration Function | Automatic correlation coefficient calculation |
| Optional Accessory | Thermal printer |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6450 |
| Detection Elements | K, Na, Li, Ca, Ba |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Li | 0.005 mmol/L |
| Ca | 0.01 mmol/L |
| Ba | 0.02 mmol/L (typical) |
| Response Time | <8 s |
| Repeatability | RSD ≤1.5% |
| Sample Uptake Rate | 6–8 mL/min |
| Display | 7-inch capacitive touchscreen LCD |
| Data Storage | Up to 10-point calibration curves and 200 sample results |
| Connectivity | USB port, USB flash drive export, cloud-enabled data synchronization |
| Safety Features | Automatic flame-out detection, gas leak alarm |
| Calibration Modes | Linear and piecewise linear (broken-line) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Rated Power | 30 W |
| Printer | Optional external thermal printer |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i3 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 360–900 nm (Visible) |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Display | 7-inch TFT touchscreen (1024 × 768) |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Wavelength Setting | Automatic |
| Light Source | Dual-lamp system with long-life halogen and deuterium lamps (optional UV extension) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Software Functions | Wavelength scanning, kinetic analysis, quantitative analysis, nucleic acid/protein assay, spectral overlay, derivative/integration processing |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | i4 |
| Instrument Architecture | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Spectral Bandwidth | 4 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% Transmittance, –0.3 to 3.0 Absorbance |
| Display | 7-inch capacitive touchscreen (1024 × 768 resolution) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Software Functions | Wavelength Scanning, Kinetic Measurement, Quantitative Analysis, Nucleic Acid & Protein A260/A280 Assay, Multi-Wavelength Overlay, First-Order Derivative, Integration |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | i5 |
| Quotation | Upon Request |
| Optical Design | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 360–900 nm (Visible Region) |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5%T at 420 nm (NaNO₂ reference) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i6 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Display | 7-inch capacitive touchscreen (1024 × 768 px) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Auto Functions | Automatic wavelength calibration, automatic lamp switching (D₂/WS), T/A mode toggle, real-time baseline correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-3700 |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Internal Storage | 5000 absorbance measurements or 500 calibration curves |
| Data Export Formats | *.csv, *.qua, *.txt, *.bmp |
| Compliance | GLP/GMP-aligned software architecture with user management, audit trail, and electronic signature support |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L-3700S |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1 nm (standard), adjustable to 0.5/2.0/4.0/5.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-3800 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI) |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Light Source | Imported deuterium and tungsten lamps |
| Internal Data Storage | Up to 5000 absorbance measurements or 500 calibration curves |
| Scan Speed | Full-spectrum scan in <1.5 s |
| Auto-functions | Automatic wavelength calibration, source switching, zero adjustment, and baseline correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L-3800S |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (fixed), with optional 0.5/2.0/4.0/5.0 nm selectable via software |
| Stray Light | ≤0.03% T at 220 nm (NaI) |
| Absorbance Range | –4 to +4 Abs |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Internal Storage | 5000 absorbance measurements or 500 calibration curves |
| Data Export Formats | CSV, QUA, TXT, BMP |
| Compliance | GLP/GMP-ready software architecture with user management, audit trail, and electronic record retention |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L1 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (default per spec sheet) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂ method) |
| Display | 7-inch color TFT-LCD touchscreen (1024 × 768 resolution) |
| Data Storage | 2000 spectra or absorbance readings |
| Connectivity | USB 2.0 port, integrated Wi-Fi module, Bluetooth 5.0 module |
| Software Compatibility | Yokelab PC software (optional), cloud sync via YOKE@Cloud Data app |
| Data Export | CSV/Excel-compatible format via USB flash drive |
| Compliance | Designed to support GLP-compliant workflows with timestamped audit trails, user-access logging, and exportable metadata |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L2 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (optional) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Display | 7-inch color TFT-LCD (1024 × 768) with capacitive touch |
| Data Storage | 2000 spectra + 96 calibration curves |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Interface | Yokelab PC software (optional), YOKE@Cloud Data mobile app (QR-code enabled) |
| Output Format | CSV/Excel-compatible export via USB drive |