Spectroscopy Instruments
Filter
Showing 1201–1230 of 2631 results
| Brand | Luchu Tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Detector Type | CCD |
| Spectral Range | 200–1100 nm |
| Optical Resolution | 0.11–3.42 nm (FWHM) |
| Signal-to-Noise Ratio | 1000:1 (full signal) |
| Dynamic Range | 4400:1 (single acquisition) |
| Stray Light | <1% |
| Detector | 2048 × 64 pixel back-illuminated CCD with single-stage TEC cooling |
| Pixel Size | 14 µm × 14 µm |
| Optical Design | Crossed Czerny-Turner |
| f-number | f/4 |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Integration Time | 2.4 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| Interface | USB 2.0 Type-B |
| Digital I/O | Yes |
| Fiber Connector | SMA905 |
| Weight | 1.25 kg |
| OS Compatibility | 32/64-bit Windows 7/10/11 |
| Brand | Luchu Tech |
|---|---|
| Model | SEER |
| Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelengths | 532 nm / 785 nm |
| Raman Shift Range | SEER-532: 150–3600 cm⁻¹ |
| SEER-785 | 200–2500 cm⁻¹ |
| Spectral Resolution | SEER-532: 7 cm⁻¹ (25 µm slit, measured) |
| SEER-785 | 6 cm⁻¹ (25 µm slit, measured) |
| Wavenumber Accuracy | ±3 cm⁻¹ |
| Detector Integration Time | 9.5 ms – 20 s |
| SNR | 600:1 |
| Dynamic Range | 79,000:1 |
| Laser Linewidth | <0.1 nm |
| Laser Output | Multimode/Single-mode options at 100 mW or 500 mW |
| Microscope Spot Size | 3 µm @ 100× (532 nm, measured) |
| Objective Lenses | Interchangeable 10×/20×/50×/100× |
| Illumination | LED white-light coaxial illumination |
| Tube Lens Focal Length | 180 mm |
| Software | RudeerTek RamanSoft (Windows 32/64-bit, Win7/10/11) |
| Interface | USB 2.0 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Detector Type | CCD Array |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.11–3.42 nm |
| Signal-to-Noise Ratio | 450:1 (full signal) |
| Dynamic Range | 2100:1 (single acquisition) |
| Stray Light | <1% |
| F-number | f/4 |
| Optical Design | Crossed Czerny-Turner |
| Slit Options | 10/25/50/75/100 µm |
| Pixel Array | 2048 × 64 pixels |
| Pixel Size | 14 µm × 14 µm |
| A/D Resolution | 16-bit |
| Integration Time | 2.4 ms – 10 s |
| Linearity | ≥0.998 |
| Interface | USB 2.0 Type-B, Digital I/O, SMA905 fiber port |
| Weight | 1.07 kg |
| OS Support | 32/64-bit Windows 7/10/11 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | SLAK |
| Detector | CMOS linear array sensor (2048 × 1 pixels) |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.3–7 nm |
| Signal-to-Noise Ratio | 320:1 |
| Dynamic Range | 1500:1 |
| Stray Light | <1% |
| Optical Design | Symmetrical Czerny-Turner |
| f-number | f/7 |
| Cooling | Uncooled |
| Interface | USB Type-C, Digital I/O |
| Fiber Connector | Standard SMA905 (customizable) |
| Dimensions | 95 × 68 × 25 mm |
| Weight | 195 g |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFlector |
| Beam Configuration | Single-beam |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 290 nm – 1650 nm |
| Wavelength Accuracy | > ±20 nm |
| Stray Light | < 0.01% T |
| Automation Level | Automatic Wavelength Scanning |
| Sample Interface | Non-contact, optical surface |
| Measurement Time | ~20 s per analysis |
| Calibration | User-definable or factory-customized for specific product matrices |
| Product Parameter Output | Up to 4 simultaneous quantitative parameters per measurement |
| Preloaded Methods | Up to 8 product-specific analysis profiles |
| Brand | Lumenera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LFFM-20 |
| Price Range | USD 14,000 – 28,000 |
| Sampling Rate | 0–20 kHz |
| Dynamic Range | 2 × 10⁵ |
| Spectral Response | CIE 1931 V(λ), f₁′ ≤ 4.5% |
| Detector Dimensions (mm) | 25 × 25 × 45 |
| Power Meter Dimensions (mm) | 300(L) × 210(W) × 90(H) |
| Interface | USB |
| Compliance Standards | IEC TR 61547-1, CIE TN 006:2016, IEEE 1789-2015, ENERGY STAR SSL V2.1, IES TM-30-20, CEC Title 20, ASSIST Mp, CIE SVM, Pst-LM |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-Panaroma |
| Wavelength Range (Excitation) | 210–840 nm |
| Wavelength Range (Emission) | 210–690 nm (up to 840 nm optional) |
| Spectral Resolution | <8 nm (15 nm optional) |
| Wavelength Accuracy | <3 nm |
| Signal-to-Noise Ratio | >100 (up to 200) |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Sensitivity | >200:1 |
| Detector | PMT |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Volume | 0.01–3 mL |
| Dimensions | 400 × 355 × 150 mm |
| Weight | 13 kg |
| Power Supply | 110/220 V, 50/60 Hz, 60 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Model | InfraLUM FT-12 |
| Wavelength Range | 760–1150 nm |
| Spectral Resolution | 8 / 16 / 32 / 64 cm⁻¹ |
| Sampling Mode | Diffuse Reflectance / Transmission |
| Data Acquisition Interval | 1 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Sample Volume | 50 mL |
| Analysis Time | ≤90 s |
| Dimensions | 530 × 450 × 380 mm |
| Weight | 32 kg |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 110 W |
| Chemometrics Software | RIM (with PARCLE integration) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | InfraLUM FT-12 Industrial |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) NIR |
| Wavelength Range | 760–1150 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Parcel |
| Sample Compatibility | Liquid, semi-solid, and homogeneous solid samples in transmission cells |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | FT-08 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 8000–350 cm⁻¹ |
| Resolution | 0.25–64 cm⁻¹ (selectable) |
| Scan Speed | 0.8 s at 16 cm⁻¹ |
| SNR | >75,000 (4 cm⁻¹, 1 min, 2150±50 cm⁻¹) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Detector | High-Sensitivity DLATGS |
| Beamsplitter | KBr-coated Ge (8000–350 cm⁻¹), hermetically sealed and desiccated |
| Interferometer | Patented Suspended Double Cat’s Eye Design |
| Light Source | High-Stability Ceramic IR Emitter |
| Power Consumption | 65 W |
| Dimensions | 580 × 550 × 340 mm |
| Weight | 32 kg |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-1000 |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Quasi-Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect (50 kHz) |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A |
| RSD (Repeatability) | ≤0.3% |
| Detection Limit (Cu) | <0.006 µg/L |
| Max Graphite Furnace Temperature | 3000 °C |
| Heating Rate | Up to 7000 °C/s |
| Argon Flow Rate | <1 L/min (high-purity) |
| Wavelength Range | 185–900 nm |
| Typical LODs | Pb ≤0.05 µg/L, Cr ≤0.01 µg/L |
| Dimensions | 800 × 475 × 310 mm |
| Weight | 50 kg |
| Power Supply | 380 VAC, 50 Hz (3-phase) |
| Cooling | Integrated Closed-Loop Recirculating Water System |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-915MD |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A (for Cu at 324.8 nm) |
| RSD (Repeatability) | <0.3% |
| Detection Limit (Cu) | <0.006 mg/L |
| Detection Limits (Typical) | Pb ≤ 0.05 µg/L, Cr ≤ 0.01 µg/L |
| Max Graphite Furnace Temperature | 2950 °C |
| Max Heating Rate | 7000 K/s |
| Argon Flow Rate (Ultra-High Purity) | <1 L/min |
| Wavelength Range | 190–900 nm |
| Dimensions | 800 × 570 × 390 mm |
| Weight | 75 kg |
| Power Supply | 380 V AC, 50 Hz (3-phase) |
| Cooling | Closed-Loop Recirculating Water System |
| Power Consumption | <0.2 kW (standby/analysis), <18 kW (atomization/cleaning) |
| Brand | LUCHI Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Detector | CMOS Linear Array |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.29–5.91 nm |
| Signal-to-Noise Ratio | 320:1 (full signal) |
| Dynamic Range | 1500:1 (single acquisition) |
| Stray Light | <1% |
| Pixel Count | 4096 × 1 |
| Pixel Size | 14 µm × 200 µm |
| Optical Design | Crossed Czerny-Turner |
| f-number | f/4 |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Integration Time | 1 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| Interface | USB 2.0 Type-B, Digital I/O |
| Fiber Connector | SMA905 |
| Weight | 460 g |
| OS Support | 32/64-bit Windows 7/10/11 |
| Brand | Luqi Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Category | Domestic (China) |
| Model | LUNA-HS / UV-Enhanced |
| Detector | Linear CMOS Array |
| Spectral Range | 200–1100 nm |
| Optical Resolution | 0.39–6.6 nm (FWHM) |
| Signal-to-Noise Ratio | 320:1 (full signal) |
| Dynamic Range | 1500:1 (single acquisition) |
| Stray Light | <1% |
| Integration Time | 1 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| F-number | f/4 |
| Optical Design | Crossed Czerny-Turner |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Pixel Array | 2048 × 1 pixels |
| Pixel Size | 14 µm × 200 µm |
| Interface | USB 2.0 Type-B, Digital I/O, SMA905 fiber port |
| Weight | 460 g |
| OS Compatibility | 32/64-bit Windows 7/10/11 |
| Brand | LuQi Technologies |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Category | Domestic (China) |
| Model | LUNA-ST |
| Pricing | Upon Request |
| Detector Type | Linear CCD Array |
| Spectral Range | 350–1100 nm |
| Optical Resolution (FWHM) | 0.39–6.6 nm |
| Signal-to-Noise Ratio | 300:1 (full signal) |
| Dynamic Range | 1300:1 (single acquisition) |
| Stray Light | <1% |
| Focal Ratio | f/4 |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Integration Time | 1 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| Pixel Count | 2048 × 1 |
| Pixel Size | 14 µm × 56 µm |
| Optical Design | Crossed Czerny-Turner |
| Weight | 460 g |
| Interfaces | USB 2.0 Type-B, Digital I/O, SMA905 fiber port |
| OS Compatibility | 32/64-bit Windows 7/10/11 |
| Brand | LWLI |
|---|---|
| Origin | Fujian, China |
| Model | D-Series |
| Instrument Type | LC-AFS Hyphenated System |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride/Vapor Generation Mode | On-line UV Digestion + Chemical Reduction |
| Target Elements (Total) | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Target Species (Speciation) | As(III), As(V), MMA, DMA, monomethylmercury (MMHg), ethylmercury (EtHg), Se(IV), Se(VI), selenomethionine, antimony species, etc. (≥12 species) |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (ng/L) | Hg ≤ 0.001 |
| PMT Wavelength Range | 160–320 nm |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | WD-2112B |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 190–850 nm |
| Sample Volume Requirement | 0.5–2 µL |
| Optical Pathlengths | 0.02, 0.05, 0.2, and 1.0 mm |
| dsDNA Detection Range | 0–27,500 ng/µL |
| BSA Detection Range | 0.06–820 mg/mL |
| Fluorescence Sensitivity (dsDNA) | 0.5 pg/µL |
| Fluorescence Linearity | ≤1.5% |
| OD₆₀₀ Accuracy | ±0.005 A (0–2 A), ±1% (2–3 A), ±2% (3–4 A) |
| Absorbance Precision | ±0.005 A or ±1% |
| Spectral Resolution | <1 nm |
| Measurement Time | <5 s |
| Power Consumption (Operating) | 25 W |
| Dimensions | 200 × 260 × 165 mm |
| Weight | 5 kg |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M500 |
| Price | Upon Request |
| Wavelength Range | 4000–600 cm⁻¹ |
| Scan Speed Options | 3 / 6 / 12 / 24 min per scan |
| Data Points per Scan | 4,250 (3 min) to 34,000 (24 min) |
| Detector | 1×2 mm DLaTGS (Deuterated L-Alanine doped Triglycine Sulfate), Sensitivity: 1 V/mW |
| Sample Compartment Area | 150 mm² |
| Display | Built-in LCD for wavenumber/absorbance readout |
| Interface | RS-232, analog recorder output |
| Heater Element | NiCr wire on sintered ceramic core |
| Dimensions | 66.7 × 38.7 × 18.4 cm (26.25″ × 15.25″ × 7.25″) |
| Weight | 17.2 kg (38 lbs) |
| Power Supply | 115/230 V AC, 50/60 Hz, 150 W |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M530 |
| Price Range | USD 9,200 – 13,100 (est.) |
| Optical Design | Pseudo-Double-Beam |
| Detector | DLATGS (Deuterated L-Alanine doped Triglycine Sulfate) |
| Spectral Range | 4000 – 600 cm⁻¹ |
| Spectral Resolution | <3 cm⁻¹ (4000–2000 cm⁻¹), <2 cm⁻¹ (2000–600 cm⁻¹) |
| Wavelength Accuracy | ±0.1 cm⁻¹ |
| Spectral Bandwidth | 4 cm⁻¹ (nominal) |
| Stray Light | <0.01% T |
| Automation Level | Motorized Wavelength Calibration & Auto-Alignment |
| Display | Integrated 7-inch Capacitive Touchscreen |
| Interface | RS-232, USB 2.0 |
| Power Supply | 115/230 VAC, 50/60 Hz, 150 W |
| Dimensions (W×D×H) | 66.7 × 38.7 × 18.4 cm |
| Weight | 17.2 kg (38 lbs) |
| Sample Compartment | 150 mm² Clear Aperture |
| Source | Ceramic-encapsulated NiCr Wire (1250 K, 36 W) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | NANOCOLOR 500D |
| Wavelength Range | 340–860 nm |
| Wavelength Selection | 10 fixed-band interference filters (345, 365, 436, 470, 520, 540, 585, 620, 690, 800 nm) |
| Wavelength Accuracy | ±2 nm |
| Bandwidth | 10–12 nm |
| Light Source | Tungsten halogen lamp |
| Detector | Silicon photodiode |
| Photometric Accuracy | ±1% of reading |
| Stability | <0.002 Abs/h |
| Sample Holders | 16-mm round cuvettes (NANOCOLOR tubes), plus 10 mm, 20 mm, and 50 mm rectangular cuvettes |
| Data Storage | 500 measurements with GLP-compliant metadata |
| Display | Graphic LCD (64 × 128 pixels), backlit, 10-language interface |
| Interfaces | RS-232 (bidirectional), USB 1.1 |
| Power | Internal rechargeable 6 V / 3.2 Ah battery or AC adapter (100–240 V~, 50/60 Hz) |
| Operating Environment | 0–50 °C, ≤90% RH (non-condensing) |
| Dimensions | 227 × 282 × 105 mm |
| Weight | 2.4 kg |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | 919650.1 |
| Optical Design | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 340–960 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±1 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | ≤0.5% |
| Automation | Automatic wavelength selection |
| Compliance | EN ISO 7027 for turbidity measurement |
| Brand | Macylab |
|---|---|
| Origin | Beijing, China |
| Model | UL-5000 |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±1% (0.76 at 260 nm) |
| Wavelength Repeatability | ≤0.5% for OD < 3, ≤2% for OD 3–4 |
| Photometric Range | 0–4.000 Abs (OD600) |
| Minimum Sample Volume | 0.3 µL |
| Pathlength Options | 0.02–1 mm (auto-adjustable), 1/2/5/10 mm cuvette |
| Absorbance Resolution | 0.002 Abs (1 mm path) |
| Detector | UV-enhanced CMOS linear array sensor |
| Light Source | Imported miniature xenon flash lamp (≥10⁹ flashes, >10-year lifetime) |
| Measurement Time | <3 s |
| Display | 7-inch Android-based touchscreen |
| Optical Principle | Fixed-pathlength, direct-drop microvolume absorbance measurement |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TerraSpec HALO |
| Instrument Type | Portable |
| Operating Principle | Grating-based Scanning NIR Spectrometer |
| Wavelength Range | 350–2500 nm |
| Scan Rate | 100 spectra per second |
| Spectral Sampling Interval | 1 nm |
| Measurement Modes | Diffuse Reflectance, Specular Reflectance, Transmission |
| Chemometrics Software | Indico Pro |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.3 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Scanning Mode | Automatic |
| Housing Material | Reinforced Engineering Plastic with Aluminum Alloy Base Structure |
| Sample Compartment Design | Removable Front Panel, Damped Hinged Lid (0–120° Position Lock), Integrated Spill Drain Port |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | P1 |
| Price Range | USD 1,400 – 2,800 |
| Optical Configuration | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195 – 1050 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.8 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | P3 |
| Price Range | USD 1,400 – 2,800 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.5 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | P4 |
| Price Range | USD 2,800 – 4,200 (FOB Shanghai) |
| Optical Configuration | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190 – 1100 nm |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Drive |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.3 nm |
| Stray Light | ≤0.05 %T at 220 nm and 360 nm |
| Brand | MAPADA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.5 nm |