Spectroscopy Instruments
Filter
Showing 1171–1200 of 2630 results
| Brand | LISICO |
|---|---|
| Model | LS-100 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Configuration | Modular Benchtop System |
| Optical Architecture | Michelson Interferometer with Solid-State Laser Reference |
| Spectral Range | 10,000–4,000 cm⁻¹ (1,000–2,500 nm) |
| Resolution | Adjustable down to 4 cm⁻¹ |
| Detector | Thermoelectrically Cooled InGaAs |
| Sampling Modes | Transmission (liquids), Diffuse Reflectance (solids), Non-contact Reflectance (Dual-Eye probe) |
| Connectivity | USB 3.0, Ethernet, Optional Fiber-Optic Interface (up to 8 channels) |
| Software Platform | S-Cal (PLS/QPLS modeling), S-Seq (automated sequence control), S-Online (real-time DCS integration) |
| Brand | LISICO |
|---|---|
| Model | LS-100-Pro |
| Type | Online FT-NIR Spectrometer |
| Channels | 8-channel multiplexed |
| Form Factor | Integrated cabinet system with embedded industrial PC, temperature control module, and PLC for DCS integration |
| Dimensions | 540 mm × 350 mm × 650 mm (L×W×H) |
| Weight | 10 kg (excluding spectrometer optics core) |
| Origin | Shanghai, China |
| Instrument Category | Domestic manufactured |
| Distribution Model | Authorized distributor supply |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | LITOS |
| Channel Capacity | 16–32 parallel channels |
| Environmental Chambers | 4 independent, sealed chambers with individual temperature/humidity/light control |
| Temperature Range | 0–125 °C |
| Voltage Range | −10 V to +10 V |
| Current Range | ±20 mA per channel |
| Sample Size Support | up to 2-inch substrates |
| Compliance | ISOS protocols (ISOS-L-1, ISOS-L-2, ISOS-O-1, ISOS-D-1) |
| Optional In Situ Spectroscopy | UV-VIS absorption (PV mode) or electroluminescence (OLED mode) |
| Integrated PAIOS Transient Platform Support | J-V, CELIV, DLTS, TPV, TPC, TEL, IMPS/IMVS, IS/CV |
| Automation | Full script-driven operation with timestamped data logging and real-time curve generation |
| Brand | Lohand |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LH-S700 |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2.0 nm |
| Wavelength Accuracy | ±0.5 nm (190–340 nm) |
| Wavelength Repeatability | ≤±0.2 nm (190–340 nm) |
| Stray Light | ≤0.2% at 220 nm and 360 nm |
| Brand | Louis LWL |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Detectable Elements | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | Hg ≤ 0.001 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Brand | Louyi SmartLink (LWL) |
|---|---|
| Origin | Fujian, China |
| Model | FL-200 |
| Instrument Type | Dual-Channel Hydride Generation Atomic Fluorescence Spectrometer (HG-AFS) |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Detectable Elements | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | Hg ≤ 0.001 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MD200 |
| Pricing | Upon Request |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | Acton LS 785 |
| Focal Length | 85 mm |
| Aperture Ratio | f/2.0 |
| Spectral Resolution | 5 cm⁻¹ (with 25 µm fiber) |
| Linear Dispersion | 6.13 nm/mm @ 900 nm |
| Grating | 1200 g/mm, gold-coated |
| Wavelength Range | 750–1100 nm (tunable via micrometer-driven grating stage) |
| Optical Design | Prism-based, AR-coated fused silica prism + optimized f/2 imaging optics |
| Detector Compatibility | Fully compatible with Teledyne Princeton Instruments PIXIS and PyLoN deep-depletion CCD cameras |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LSZJQ |
| Pricing | Upon Request |
| Compatible Systems | Universal Microscope–Spectrometer–Camera Integration |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aryelle 150 |
| Pricing | Upon Request |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ARYELLE400 |
| Price Range | USD 135,000–162,000 (est.) |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Focal Length | 400 mm |
| Relative Aperture | f/10 |
| Spectral Resolution (practical) | 8 pm @ 192 nm (typical), down to 4 pm @ 192 nm (max) |
| Resolving Power (λ/Δλ) | 9,400–25,000 (typical), up to 50,000 (max, practical) |
| Wavelength Coverage (single acquisition) | 192–1090 nm (configurable subsets: 192–950 nm, 192–750 nm, etc.) |
| Slit Dimensions | 50 × 50 µm (custom widths available) |
| Detector Compatibility | PI/Andor CCD (2048 × 512 px |
| Timing Resolution | 100 ns minimum gate step (2 ns / 5 ns achievable with compatible detectors) |
| Dynamic Range | 15-bit system, 16-bit A/D conversion |
| Spectral Calibration | Internal Hg lamp + motorized shutter for automated recalibration |
| Spectral Database | NIST atomic emission line database with auto-line-matching algorithm |
| Optical Coupling | Mirror-based or fiber-optic (SMA connector) |
| Spectral Accuracy | Better than 1/4 of spectral resolution |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ARYELLE Butterfly |
| Price Range | USD 135,000 – 162,000 |
| Instrument Type | Benchtop |
| Integration | Integrated System |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Coverage | 190–950 nm (UV-VIS-NIR) + VUV extension via reflective optics |
| Spectral Resolution | <20 pm @ 200 nm |
| Spectral Resolution Power | >10,000 (practical, non-pixel-limited) |
| Detector Format | 1024 × 255 pixels, 26 × 26 µm, full-well capacity 1 Me⁻ |
| Detector Cooling | −70 °C thermoelectric |
| Optional Detectors | EMCCD or ICCD |
| Focal Length | 400 mm per channel |
| f-number | f/10 |
| Calibration | Automated wavelength recalibration using Hg lamp and internal shutter |
| Optical Path | SMA-fiber-coupled for UV-VIS-NIR |
| Dual-Channel Architecture | Independent VUV and UV-VIS-NIR channels sharing one detector plane |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | ARYELLE150 |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Resolution (λ/Δλ) | 6,000 – 15,000 |
| Wavelength Coverage (Single Acquisition, No Scanning) | 200–600 nm (configurable options: 220–800 nm, 200–590 nm, 230–548 nm) |
| Slit Width | 35 µm (customizable) |
| Spectral Sampling Rate | Up to 30 spectra/s |
| Detector Interface | Fiber-coupled (SMA) or free-space |
| Calibration Source | Integrated Hg lamp with automated wavelength recalibration |
| Spectral Accuracy | Better than 1/4 of spectral resolution |
| Detector Options | EMCCD (1004 × 1002, 8 × 8 µm pixels), Scientific Cooled CCD or ICCD (application-dependent) |
| Dark Current | 0.06 e⁻/pixel/sec (@ −50 °C) |
| Full Well Capacity | 32,700 e⁻ (linear) |
| Max EMCCD Gain | 4000 |
| Timing Resolution (LIBS gating) | 100 ns minimum step width |
| NIST Emission Database Integration | Yes |
| Automatic Spectral Line Identification | Yes |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | ARYELLE200 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Resolution (λ/Δλ) | 7,000 – 20,000 (practical) |
| Wavelength Coverage (single-shot, gap-free) | 200–750 nm (configurable options: 192–594 nm, 225–574 nm, 200–900 nm, 250–950 nm) |
| Slit Width | 45 µm (optional widths available) |
| Detector Interface | SMA fiber coupling or free-space input |
| Spectral Sampling Rate | Up to 30 spectra/s |
| Detector Options | ICCD (1024 × 1024, 13 × 13 µm pixels), scientific cooled CCD/EMCCD/EMICCD |
| Minimum ICCD Gate Width | 5 ns (optional down to 0.5 ns) |
| ICCD Max Relative Gain | 1000 |
| Dark Noise | 0.2 e⁻/pixel/sec |
| Full Well Capacity | 100,000 e⁻ |
| Calibration Source | Internal Hg lamp with automated software-driven recalibration |
| NIST Emission Database Integration | Yes |
| Automatic Line Identification | Yes |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | CORALIS |
| Instrument Type | Benchtop |
| Integration | Fully Integrated Dual-Modal Platform |
| LIBS Laser Energy | Up to 50 mJ (1064 nm, optionally 532 nm or 266 nm) |
| Raman Laser Power | Up to 50 mW (532 nm and 785 nm) |
| Spectral Coverage (LIBS) | 190–520 nm (scan-free) |
| Spectral Resolution (LIBS) | 0.013–0.035 nm |
| Spectral Coverage (Raman) | 530–950 nm (up to 6000 cm⁻¹) |
| Spectral Resolution (Raman) | 2.5–2.0 cm⁻¹ (532 nm), 1.7–1.4 cm⁻¹ (785 nm) |
| XYZ Stage Travel | X=50 mm, Y=50 mm, Z=35 mm |
| Positioning Accuracy & Repeatability | 1 µm |
| Macro Imaging Field | 28 × 19 mm (10×) |
| Micro Imaging Field | 3.5 × 2.5 mm (80×) |
| Dimensions | 1200 × 750 × 750 mm |
| Laser Safety Class | Class 1 |
| Software | FusionRL CORALIS |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | DEMON NIR Series |
| Form Factor | Benchtop |
| Integration | Integrated Monolithic Design |
| Optical Configuration | Littrow-Mounted Echelle Spectrometer with Dual Grating Architecture |
| Wavelength Range | 600–1700 nm |
| Spectral Resolution (λ/Δλ) | >60,000 (e.g., <0.026 nm @ 1550 nm, <0.01 nm @ 600 nm, 0.011 nm @ 656 nm) |
| Linear Dispersion | λ/90,000 |
| Minimum Measurable FWHM | ≤0.014 nm @ 800 nm |
| Spectral Window | 2.5–8 nm (wavelength-dependent) |
| Detector Interface | Scientific-grade InGaAs area detector (16-bit) |
| Relative Aperture | f/10 |
| Minimum Exposure Time | 1 ms (CCD-compatible) |
| Stray Light Level | Ultra-low (optimized Littrow echelle optical path) |
| Absolute Wavelength Accuracy | Pixel dispersion × 10 pixels |
| Active Wavelength Stabilization | Built-in Hg reference lamp + automated self-calibration |
| Control Interface | Full PC-based motorized control via USB/Ethernet |
| Dimensions (L×W×H) | 600 × 310 × 230 mm |
| Weight | 25 kg |
| Software Platform | SOPHI spectral acquisition & analysis suite (LabVIEW driver optional) |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | DEMON Series |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Wavelength Range | 175–1100 nm (configurable) |
| Spectral Resolution | down to 1.34 pm @ 200 nm |
| Spectral Resolving Power | 75,000–200,000 |
| Linear Dispersion | λ/225,000 |
| Absolute Wavelength Accuracy | ±0.25 pm (after auto-calibration) |
| Stray Light Level | <10⁻⁶ |
| Detector Compatibility | Scientific CCD, ICCD, EMCCD, EMICCD |
| Slit Control | Motorized |
| Shutter | Integrated Mechanical |
| Exposure Time | 1 ms (CCD), 5 ns / 2 ns (ICCD) |
| Interface | Full PC-based motorized control |
| Dimensions (L×W×H) | 750 × 310 × 230 mm |
| Weight | 25 kg |
| Software | Sophi (with embedded NIST spectral database), LabVIEW driver optional |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | LTB LIBSorter |
| Instrument Type | Benchtop |
| Integration | Integrated System |
| Laser Energy | 5 mJ – 850 mJ |
| Brand | Ocean Optics |
|---|---|
| Model | FD-LTMS |
| Wavelength Range | 400–700 nm |
| Detector | 1024-element linear array |
| Optical Design | Asymmetric crossed Czerny-Turner spectrometer |
| Spectral Sampling Interval | 10 nm |
| FWHM | 6 nm |
| Light Source | Pulsed LED (>250 million measurements lifetime) |
| Sample Holders | 10 mm pathlength cuvette & flow-cell interface |
| Connectivity | USB 2.0 |
| OS Compatibility | Windows 7+, 64-bit |
| Enclosure Rating | IP67 |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating (1800 lines/mm, blazed at 250 nm) |
| Optical System | Single-beam Czerny-Turner |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm (6-step automatic switching) |
| Wavelength Range | 185–900 nm |
| Lamp Positions | 8 |
| Optical Platform | 20-mm-thick monolithic aluminum vibration-isolated mounting base |
| Atomizer | Titanium combustion head with motorized vertical positioning |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating (1800 lines/mm, blazed at 250 nm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Wavelength Range | 185–900 nm |
| Spectral Bandwidths | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm (6-step automatic switching) |
| Lamp Positions | 8 |
| Optical Platform | 20-mm-thick monolithic aluminum vibration-isolated mount |
| Atomizer | Titanium combustion system with motorized vertical positioning |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Plane Grating (1800 lines/mm, blazed at 250 nm) |
| Optical System | Single-beam Czerny-Turner |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Dual-Mode |
| Spectral Bandwidths | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm (6-step automatic switching) |
| Wavelength Range | 185–900 nm |
| Lamp Positions | 8-slot automatic turret |
| Atomizer Control | Motorized graphite furnace vertical positioning |
| Automation | Fully automated wavelength scanning, peak search, HV optimization, energy balancing, and method recall |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LIM-001 |
| Price | Upon Request |
| Wavelength Range | 190–1100 nm |
| Detector | Imported Silicon Photodiode |
| Monochromator | Czerny-Turner Mount with Holographic Blazed Grating |
| Cuvette Material | Quartz |
| Lamp Switching | Automatic at 340 nm (adjustable) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | M5 |
| Quotation | Upon Request |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Display | 11-inch 2.8K Resolution Tablet PC |
| Optical System | Dual-Beam Ratio Monitoring |
| Light Sources | Deuterium Lamp + Tungsten Halogen Lamp |
| Spectral Bandwidth | 2 nm |
| Photometric Resolution | 0.00001 Abs |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | M600 |
| Optical System | Dual-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Photometric Range | –4 to +4 Abs |
| Photometric Resolution | 0.00001 Abs |
| Wavelength Scanning Mode | Automated |
| Display | 11-inch 2.8K Tablet (iPad-compatible, touch-enabled, bilingual UI) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | M6S |
| Quotation | Upon Request |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Display | 11-inch 2.8K Resolution Tablet PC |
| Light Sources | Deuterium Lamp + Tungsten Halogen Lamp |
| Spectral Bandwidth | Adjustable (0.1 / 0.2 / 0.5 / 1 / 2 / 4 / 5 nm) |
| Absorbance Resolution | 0.00001 Abs |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | M700S |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Display | 11-inch 2.8K Resolution Tablet PC |
| Light Sources | Deuterium Lamp & Tungsten-Halogen Lamp |
| Photometric Range | –4 to +4 Abs |
| Photometric Resolution | 0.00001 Abs |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | M8 |
| Pricing | Upon Request |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Motorized Wavelength Scanning |
| Display | 11-inch 2.8K Tablet (iPad-compatible interface) |
| Spectral Bandwidth | 1 nm |
| Absorbance Resolution | 0.00001 Abs |
| Light Source | Pulsed Xenon Lamp |
| IoT Connectivity | Embedded Wi-Fi & Bluetooth |
| User Management | Multi-tier Role-Based Access Control |
| Data Notification | Email & SMS Alerting for Anomalies |
| Compliance Support | Audit Trail Ready (GLP/GMP-aligned logging) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Display | 11-inch 2.8K Resolution Tablet PC |
| Optical System | Dual-beam with Integrated Reference Detector |
| Light Source | Pulsed Xenon Lamp |
| Photometric Range | –4 to +4 Abs |
| Photometric Resolution | 0.00001 Abs |
| Spectral Bandwidth | 1 nm |