| Brand | JKRD |
|---|---|
| Model | AA800 |
| Type | Flame AAS |
| Origin | Beijing, China |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 180–900 nm |
| Grating Density | 1800 lines/mm |
| Monochromator | Czerny-Turner |
| Spectral Bandwidths | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switching) |
| Wavelength Accuracy | ≤ ±0.1 nm |
| Wavelength Repeatability | ≤ ±0.025 nm |
| Baseline Drift | ≤ 0.003 ABS/30 min (static), ≤ 0.005 ABS/15 min (dynamic) |
| Resolution (Cu 324.7 nm, 0.2 nm BW) | ≤ 0.2 ± 0.01 nm |
| Characteristic Concentration (Cu) | 0.025 µg/mL / 1% |
| Detection Limit (Cu) | 0.006 µg/mL |
| Burner Head | Titanium, 0.5 mm × 100 mm |
| Nebulizer | High-efficiency glass-in-metal |
| Atomization Chamber | Corrosion-resistant all-plastic |
| RSD (repeatability) | ≤ 0.5% |
| Safety Features | Auto-shutoff on acetylene leak detection, flame-out protection, gas flow monitoring |
| Power Supply | AC 220 V / 50 Hz, 150 W |
| Dimensions | 1000 × 400 × 470 mm (L×W×H) |
| Weight | 70 kg |
| Software | Windows XP/Vista/7 compatible, Chinese-language AAS control & quantitation suite with linear regression calibration, multi-point standard curve fitting, statistical reporting, and RS232/USB connectivity |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio1000 |
| Spectral Bandwidth | 1.0, 0.5, 0.1, 0.05, 0.02 mm (auto-switching) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 185–910 nm |
| Cuvette Absorbance Range | 0–4 A |
| Sample Volume | 0.2–2.0 µL |
| Optical Path Lengths | 0.02–1.0 mm (motorized auto-adjustment) |
| Light Source | Xenon flash lamp (≥10⁹ flashes, ~10-year operational life) |
| Detector | 3648-pixel linear CCD array |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.002 A |
| OD₆₀₀ Mode | 600 ± 8 nm |
| Measurement Time | ≤5 s per sample |
| dsDNA Quantitation Range | 0–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Data Export | USB port, microSD slot |
| Optional fluorescence module (Ex | 460 nm, Em: 525 nm) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio1000 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 185–910 nm |
| Cuvette Mode (OD600) | 600 ± 8 nm |
| Sample Volume | 0–2.0 µL |
| Optical Path Lengths | 1.0 / 0.5 / 0.1 / 0.05 / 0.02 mm (auto-switching) |
| Light Source | Xenon flash lamp (≥10 yr lifetime) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm (FWHM at Hg 546 nm) |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.002 A |
| Absorbance Range (10-mm equivalent) | 0–780 A |
| OD600 Range | 0–4 A |
| Measurement Time | ≤5 s |
| dsDNA Quantification Range | 0–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Data Export | USB port, SD-RAM card |
| Optional fluorescence module (Ex | 460 nm, Em: 525 nm) |
| Brand | JU CHUANG ENVIRONMENTAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Domestic |
| Model | UV-759CRT |
| Optical Design | Single-beam |
| Detector | CMOS array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | 0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Photometric Accuracy | ±0.003% T |
| Photometric Repeatability | 0.001% T |
| Absorbance Range | –0.30 to 3.00 A |
| Transmittance Range | 0.0–200.0% T |
| Concentration Range | 0–1999 units |
| Baseline Flatness | ±0.001 A |
| Stability | ±0.0005 A/h at 500 nm |
| Interface | USB (RS-232 emulation) |
| Display | 128×64 graphic LCD |
| Data Storage | 200 calibration curves + 200 measurement sets |
| Software Support | UV-759CRT dedicated analysis software |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm (over full operating temperature range) |
| Detector | Photomultiplier Tube (PMT) |
| Optical Design | Dual Monochromator |
| Power Supply | 230 VAC or 115 VAC |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather housing) |
| Measured Parameters | Total Ozone Column, SO₂ Column, Spectral UV Irradiance (UVA, UVB, UVE), UV Index (UVI) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SSR-3000 |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 180–3300 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Signal-to-Noise Ratio | 400:1 @ 100 ms integration time |
| Excitation Wavelength | 785 ± 0.5 nm |
| Laser Linewidth | < 0.06 nm |
| Output Power | 0–500 mW (digitally adjustable) |
| Integration Time | 10 ms – 20 min |
| Weight | < 4 kg |
| Dimensions | 370 × 270 × 120 mm |
| Power Supply | External AC 100–240 V, 50/60 Hz |
| Internal Battery | 12 V, 8000 mAh Li-ion (laptop-grade) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-2600d / CM-2500d |
| Optical Geometry | d/8° integrating sphere (SCI/SCE simultaneous measurement) |
| Wavelength Range | 360–740 nm |
| Wavelength Interval | 10 nm |
| Spectral Bandwidth | ~10 nm |
| Detector | Dual-row silicon photodiode array (40 elements) |
| Illumination | Pulsed xenon lamp (2 lamps for CM-2500d |
| Measurement Apertures | MAV Φ8 mm / SAV Φ3 mm |
| Repeatability | ΔE*ab ≤ 0.04 (after white calibration, 30 measurements) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.2 (SCI/MAV, BCRA Series II) |
| Display | High-resolution graphical LCD with intuitive navigation wheel interface |
| Compliance | ISO 7724-1, CIE No. 15, ASTM E1164, DIN 5033-7, JIS Z 8722, ISO 2470, ASTM D2244, E308, E313, E1164, BS 6923, VDA 280 Part 1–3 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | FD-9 |
| Optical Geometry | 45°a:0° (annular illumination) |
| Wavelength Range | 380–730 nm |
| Wavelength Interval | 10 nm |
| Spectral Bandwidth | ~10 nm |
| Measurement Aperture | ~3 mm |
| Light Source | LED |
| Reflectance Range | 0–150% |
| Repeatability | σΔE₀₀ ≤ 0.05 (after white calibration, 30 measurements at 1 s intervals) |
| Inter-instrument Agreement | ΔE₀₀ ≤ 0.3 (BCRA Series II 12-color tile average) |
| Measurement Time | ~4 minutes for 1500 patches |
| Compliance | CIE No. 15, ISO 7724-1, ISO 13655, DIN 5033 Teil 7, ASTM E1164, JIS Z 8722 |
| Interfaces | USB 2.0, 10/100Base-T Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz → DC 24 V, 5 A |
| Dimensions (FD-9 only) | 716 × 251 × 159 mm |
| Weight (FD-9 only) | ~10.5 kg |
| Operating Environment | 10–35 °C, 30–85% RH (non-condensing) |
| Brand | KPM PSC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QuikCheck |
| Application | Laboratory & At-Line Analysis |
| Instrument Principle | Filter-Based NIR |
| Wavelength Channels | 1400 nm, 1820 nm, 1940 nm, 2200 nm |
| Scan Speed | Real-Time |
| Data Sampling Interval | User-Configurable |
| Sample Presentation | Diffuse Reflectance |
| Chemometrics Software | Onboard Embedded Suite |
| Brand | KPM Sensortech |
|---|---|
| Origin | USA |
| Model | NIR-6000 |
| Instrument Type | Online Near-Infrared Spectrometer |
| Principle | Filter-Based NIR Reflectance |
| Wavelength Range | 550–2500 nm |
| Measurement Interval | User-Configurable (as low as 4 ms) |
| Sampling Mode | Diffuse Reflectance |
| Scan Speed | Real-Time |
| Chemometrics Software | Embedded KPM NIR Analysis Suite |
| Operating Temperature | −20°C to +85°C (with optional thermal management) |
| Ingress Protection | IP65 |
| Calibration | Pre-Loaded Application-Specific Models |
| Brand | KPM Unity |
|---|---|
| Origin | USA |
| Model | SpectraStar XT Series |
| Wavelength Range | 680–2600 nm |
| Scan Speed | 10–60 s (20 scans) |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Detector | Cooled Dual InGaAs |
| Calibration Standard | NIST-traceable |
| Software | uScan & UCAL |
| Power Consumption | <5 W |
| Operating Temperature | 1–40 °C |
| Compliance | ISO 12099, LIMS-compatible, IP52-rated enclosure |
| Sample Mass Range | 1–300 g |
| Optical System | Holographic Scanning Grating, Sealed All-Reflective Path with Fused Silica Window |
| Brand | KRÜSS |
|---|---|
| Origin | Germany |
| Model | FP8000 |
| Measurement Principle | Flame Atomic Emission Spectrometry (F-AES) |
| Simultaneous Channels | 5 |
| Detectable Elements | Na, K, Li, Ca, Ba, Mg |
| Display | 8.4" TFT Touchscreen |
| Data Storage Capacity | 999 measurements |
| Measurement Throughput | up to 300 samples/hour |
| Compliance | cGMP/GLP, FDA 21 CFR Part 11, DHCP & LIMS Integration Capable |
| Safety | Integrated Intelligent Safety System |
| Calibration Output | Tabular and Graphical Calibration Curves |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Model | BE-9000 |
| Spectral Range | 190–850 nm |
| Spectral Bandwidth | 190–850 nm (full-range xenon flash lamp) |
| Wavelength Accuracy | ±1 nm |
| Sample Volume | 0.5–2 µL |
| Optical Path Lengths | 0.05 mm, 0.2 mm, and 1.0 mm |
| dsDNA Quantitation Range | 2–15,000 ng/µL |
| Absorbance Accuracy | ±1% at 7.332 A (260 nm) |
| Absorbance Precision | 0.003 A (at 0.2 mm path) |
| Absorbance Linearity Range (10-mm equivalent) | 0.04–300 A |
| Measurement Time | <6 s |
| OD600 Range | 0.000–6.000 A |
| Detector | Hamamatsu UV-enhanced CMOS linear array sensor |
| Light Source | Pulsed xenon flash lamp |
| Display | 7-inch capacitive touchscreen (1024 × 600) |
| Operating System | Android-based embedded OS |
| Dimensions | 200 × 260 × 165 mm |
| Weight | 5 kg |
| Power Supply | DC 24 V adapter |
| Power Consumption | 25 W (operational), 5 W (standby) |
| Absorbance Stability & Repeatability | ≤0.5% (0–3 A), ≤2% (3–4 A) |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L Boundary Density Meter |
| Pricing | Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabFlicker |
| Dimensions (L × W × H) | 115 × 53 × 13 mm |
| Weight | 0.16 kg |
| Shipping Dimensions (L × W × H) | 170 × 130 × 70 mm |
| Shipping Weight | 0.5 kg |
| Warranty | 2 years |
| Software Integration | Light Inspector (Viso Systems) |
| Output Metrics | Flicker Percentage, Flicker Index, Flicker Frequency, SVM (Stroboscopic Visibility Measure), PstLM (Short-Term Flicker Indicator per IEC TR 61547-1), JA8 §24 Compliance Data |
| Data Export | CSV & Excel-compatible arrays |
| Real-time Signal Processing | Onboard intelligent algorithm engine |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LABMAN High-Throughput Automated Absorbance Measurement System |
| Optical Design | Dual-Beam |
| Detector | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–900 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 650 nm |
| Wavelength Accuracy | ±2.0 nm |
| Stray Light | ≤0.01% T |
| Sample Capacity | 192-position rack (17 mm height, dual-diameter transparent glass vials) |
| Throughput | Up to 180 samples/hour |
| Scan Speed | ≥12 vials/minute |
| LED Source | Red 4-element array @ 650 nm |
| Brand | Labsphere |
|---|---|
| Model | CSS-04-010 |
| Material | Spectralon® (PTFE-based diffuse reflectance standard) |
| Diameter | 1.25 in |
| Colors | Red, Green, Blue, Yellow |
| Reflectance Uniformity | < ±0.2% across surface |
| Angular Independence | Lambertian behavior (±0.5° viewing angle tolerance) |
| Thermal Stability | –40 °C to +80 °C |
| Cleanability | Water-rinsable, non-abrasive wipe compatible |
| Compliance | NIST-traceable calibration available (optional) |
| Origin | USA |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LABSPION |
| Price | USD 35,000 (FOB Copenhagen) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Model | LabAA 2000 |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Resolution | Mn Doublet (279.5–279.8 nm), Valley-to-Peak Ratio ≤30% at 279.5 nm |
| Sensitivity | Flame Mode — Cu Characteristic Concentration ≤0.035 mg/L |
| Precision (RSD) | Flame Cu (2 ppm) ≤1.0% |
| Detection Limits | Flame — sub-ppb to ppm range |
| Baseline Stability | ≤±0.003 Abs over 30 min at Cu 324.8 nm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Liquid Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Rotameter |
| Detectable Elements | As, Sb, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn |
| Relative Standard Deviation (RSD) | ≤0.7% |
| Linear Dynamic Range | ≥3 orders of magnitude |
| Detection Limits | As, Se, Bi, Pb, Sb, Te, Sn, Zn < 0.01 µg/L |
| Photomultiplier Tube (PMT) Wavelength Range | 160–320 nm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | <1 ppb (typ. for key elements) |
| Precision (RSD) | ≤1% |
| Stability (RSD, 4h) | ≤2% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | 6 pm / 7 pm / 10 pm @ 257.610 nm (Mn line, measured) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | LabICP 2000 ICP-OES |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Optical Design | Prism + High-Resolution Echelle Grating Two-Dimensional Cross-Dispersed System |
| Detector | Megapixel Large-Area CCD |
| Plasma Orientation | Vertical Torch |
| Observation Modes | Radial, Axial, Dual-View, and Attenuated Variants |
| Gas Control | Mass Flow Controllers (MFCs) for All Gases |
| Software | HiICP Platform with Real-Time & Offline Analysis Capabilities |
| Cooling | Thermoelectrically Cooled CCD with MPS Thermal Isolation Structure |
| Purge | Positive-Pressure Sealed Spectrometer Chamber with Independent Front-Optics Purge |
| RF Generator | Solid-State Crystal-Controlled RF Source with Real-Time Power Monitoring |
| Brand | Laman Optics |
|---|---|
| Origin | Guangdong, China |
| Model | LM70 |
| Spectral Range | 380–800 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 2 nm @ 50 µm slit width, 4 nm @ 100 µm slit width |
| Sensitivity | 75 photons/count @ 400 nm |
| Signal-to-Noise Ratio | >60 dB |
| Interface | USB 2.0 (bus-powered) |
| Fiber Connector | SMA905 |
| Software Features | Wavelength calibration, irradiance measurement, absorbance, transmittance, time-resolved spectral scanning |
| Brand | Laman Optics |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LMS300A3 |
| Application System | Universal |
| Number of Gratings | 3 |
| Wavelength Range | 200–1400 nm |
| Wavelength Accuracy | ±0.4 nm (200–900 nm), ±2.0 nm (900–1400 nm) |
| Wavelength Repeatability | ±0.2 nm (200–900 nm), ±1.0 nm (900–1400 nm) |
| Grating Options | 1200 L/mm (Grating 1), 600 L/mm (Grating 2), Custom Third Grating (e.g., 300 L/mm or 2400 L/mm) |
| Slit Width Adjustment | 0–2 mm (continuous, 0.01 mm resolution), Slit Height: 15 mm |
| Focal Length | 302.5 mm |
| Stray Light | ≤0.3% T |
| Dimensions | 436 × 267.5 × 190 mm |
| Weight | 20 kg |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Lamda-280R / 280RS / 280D / 280DS |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Selection |
| Spectral Bandwidth | 1.8 nm (fixed) |
| Wavelength Accuracy | ±0.1 nm at 656.1 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% T at 220 nm and 360 nm |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | LIBS 3000 |
| Instrument Type | Online |
| Pricing | Upon Request |
| Key | Value Format: None |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LIBS 5000 |
| Instrument Type | Online |
| Pricing | Upon Request |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Handheld |
| Model | LIBS 810 |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (software audit trail enabled) |
| Laser Class | 3B (IEC 60825-1 compliant) |
| Weight | 1.65 kg |
| Detection Principle | Pulsed Nd:YAG laser-induced plasma emission spectroscopy |
| Elemental Coverage | Mg, Al, Si, Fe, Cu, Zn, Mn, Ti, Cr, Ni, Pb, Sn, and other metallic elements (Z ≥ 12) |
| Typical LOD | 1–50 ppm for major alloying elements (matrix-dependent) |
| Spectral Resolution | < 0.1 nm (FWHM at 300–800 nm range) |
| Analysis Time | ≤ 2 s per measurement |
| Sample Form Compatibility | Solid metals (polished or as-received), alloys, scrap, coatings, welds |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Handheld |
| Model | LIBS 820C |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (Software Audit Trail Enabled) |
| Laser Class | 3B Pulsed Nd:YAG (1064 nm, <10 ns pulse width, ≤50 mJ/pulse) |
| Weight | 1.7 kg |
| Detection Elements | C, Si, Mn, Cr, Ni, Mo, V, Nb, Ti, Al, Cu, Co, W, B, Be, Li, P, S, N, Fe (matrix) |
| Typical Carbon LOD | 25–50 ppm (steel matrix, Ar purge) |
| Spectral Resolution | ≤0.1 nm (FWHM @ 247.8 nm C I line) |
| Analysis Time | ≤3 s per measurement |
| Sample Interface | Non-contact, micro-ablation spot size: 50–100 µm |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Environmental Rating | IP54 |
| Operating Temperature | −10 °C to 50 °C |