Spectroscopy Instruments
Filter
Showing 1561–1590 of 2629 results
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Instrument Type | Imported |
| Model | LAMBDA 465 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T at 340 nm |
| Automation | Motorized Wavelength Scanning |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Regulatory Compliance | FDA 21 CFR Part 11–enabled Software |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Lambda 650 / Lambda 850 / Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized & Auto-Calibrated |
| Wavelength Range | 175 nm to 3300 nm (model-dependent: Lambda 650: 190–900 nm |
| Lambda 850 | 175–900 nm |
| Lambda 950 | 175–3300 nm) |
| Linear Dynamic Range | Up to 8 A (Lambda 850/950), 6 A (Lambda 650) |
| Wavelength Accuracy | ±0.08 nm (UV-Vis region) |
| Stray Light | < 0.00008% T at 220 nm (typical) |
| Beam Geometry | Ratio-recording, chopper-synchronized dual-beam |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 750 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized Automatic |
| Wavelength Range | 175 nm to 3300 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 850+ |
| Instrument Architecture | Double-Beam |
| Detector Type | R6872 Photomultiplier Tube (PMT) |
| Automation Level | Motorized Wavelength Scanning |
| Wavelength Range | 175–900 nm |
| Wavelength Accuracy | ±0.025 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Imported |
| Model | Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | R6872 Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm (185 nm minimum under nitrogen purge) |
| Spectral Bandwidth | Variable (0.01–8 nm), software-selectable |
| Wavelength Accuracy | ±0.08 nm (UV/Vis), ±0.2 nm (NIR) |
| Stray Light | <0.00008% T at 220 nm (NaI), <0.0001% T at 340 nm (NaNO₂) |
| Photometric Linearity | Up to 8.0 A (absorbance) |
| Baseline Flatness | ±0.0004 A (190–3300 nm, 1 nm SBW) |
| Automation | Fully motorized optics, auto-lamp switching (D₂ & W/Tungsten), auto-correcting chopper, PC-controlled |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LS-55 |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 5300DV |
| Instrument Type | Simultaneous (Multi-Channel) ICP-OES |
| Detection Limit (Zn at 213.856 nm) | ≤0.003 µg/L |
| Precision (RSD) | ≤1.5% |
| Long-Term Stability (4-hr drift) | ≤2.0% |
| Wavelength Range | 165–870 nm |
| Optical Resolution (FWHM) | ≤0.007 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 8000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 1 ppm |
| Precision (RSD) | ≤1.5% |
| Short-Term Stability (1 hr) | RSD <1% |
| Long-Term Stability (4 hr) | RSD <2% |
| Wavelength Range | 160–900 nm |
| Optical Resolution | ≤0.003 nm (pixel resolution at 200 nm) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 8300 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Wavelength Range | 167–782 nm |
| Optical Resolution | 0.006 nm at 200 nm |
| Configuration | Used (Refurbished & Verified) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Model | PinAAcle 500 |
| Monochromator | Echelle Grating |
| Optical System | Dual-Beam |
| Detector | Solid-State CCD Array |
| Background Correction | Deuterium Lamp |
| Flame System | FAST Flame Automated Burner Head Positioning and Gas Control |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Country of Origin | Imported |
| Model | PinAAcle 900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Longitudinal Zeeman |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | PinAAcle 900Z |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Dual-Beam (not Single-Beam — corrected per official specs) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Longitudinal Zeeman Effect |
| Resolution | 0.3 nm |
| Sensitivity (Cd 228.8 nm) | 0.3 pg |
| RSD (Repeatability) | ≤0.3% |
| Detection Limit (Cd) | 0.006 pg |
| Baseline Stability | ±0.005 absorbance units/30 min |
| Height | 64.0 cm |
| Width | 95.0 cm |
| Weight | 127.0 kg |
| 21 CFR Part 11 Compliance | Yes |
| Warranty | 1 Year |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PinAAcle D900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp Correction |
| Safety Interlocks | 7 Integrated Sensors |
| Automation | Dual-Mode Autosampler Compatible with Both Flame and GF Modes |
| Software Interface | Touchscreen-Controlled Method Wizard with Real-Time Camera Integration |
| Reporting | Customizable PDF Reports Including Calibration Curves and Sample Data |
| Brand | PerkinElmer |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | PinAAcle™ 950D |
| Pricing | Available upon request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectrum 3 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Instrument Category | Fourier Transform Type |
| Wavenumber Range | Not Specified |
| Resolution | Not Specified |
| Scan Speed | Up to 100 scans/sec |
| Signal-to-Noise Ratio | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | L160000A |
| Instrument Type | Benchtop Laboratory FT-IR Spectrometer |
| Wavenumber Range | 350–7500 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Wavenumber Accuracy | ±0.1 cm⁻¹ |
| Wavenumber Precision | ±0.01 cm⁻¹ |
| Signal-to-Noise Ratio | 9,300:1 (5 scans, peak-to-peak), 32,000:1 (60 sec scan, peak-to-peak) |
| Detector | High-performance DTGS or optional MCT |
| Interferometer | DynaScan™ permanent alignment, no moving mirrors |
| Beamsplitter | KBr-coated |
| Optical Enclosure | Sealed, desiccated cavity with OpticsGuard™ moisture protection |
| Dimensions | 450 × 300 × 210 mm |
| Weight | 13 kg |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spectrum Two |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Instrument Category | Fourier Transform Infrared (FTIR) Spectrometer |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Spectrum Two N |
| Instrument Type | Laboratory Benchtop |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling (reflectance, transmission, remote probe) |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Model | Spectrum Two N |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform (Interferometric) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spotlight 400/400N |
| Instrument Type | Laboratory FT-IR Imaging System |
| Detector Architecture | Patented Linear Array MCT Detector |
| Spectral Range | Up to 720 cm⁻¹ (Mid-IR) and Extended NIR Capability |
| Spatial Resolution | 1.56 µm (ATR mode), 6.25 µm / 25 µm / 50 µm (Transmission/Reflection modes) |
| Imaging Speed | Up to 170 spectra/sec |
| Scan Modes | Single-region, Multi-region, Unattended Overnight Acquisition |
| Sample Stage | Motorized, High-Precision, Repeatability ±0.001% |
| Optional Accessories | Imaging ATR, Large-Area Sample Stage |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Wavelength Accuracy | ±0.15 nm |
| Baseline Stability | ±0.002 A/30 min (static) |
| RSD (Repeatability) | ≤0.6% for Cu (air-acetylene), ≤1.0% for Cu (LPG-air) and Ba (N₂O-acetylene), ≤2.0% for Cu and Cd (graphite furnace) |
| Characteristic Concentration | Cu < 0.02 µg/mL/1% (air-acetylene & LPG-air), Ba < 0.15 µg/mL/1% (N₂O-acetylene) |
| Detection Limit | Cu < 0.004 µg/mL (flame), Cd < 0.4 pg (graphite furnace) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Cu Sensitivity | >0.3 A at 5 ppm |
| Precision (RSD) | <0.4% |
| Cu Detection Limit | <0.004 µg/mL |
| Baseline Drift | <0.0008 A/30 min |
| Peak-to-Peak Baseline Noise | <0.0008 A/30 min |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Model | AA990 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Condition | Professionally Refurbished & Fully Qualified |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | CPG2/CPG2S |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer (GFAAS) |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | Automatic Deuterium/Hollow Cathode Lamp Dual-Beam Background Correction |
| Detection Limits | Pb: 0.02 mg/kg, Cd: 0.002 mg/kg |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Persee General Instrument Co., Ltd. |
| Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Gravity-driven |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% (for As, Sb, Bi, Hg) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL (As, Sb, Bi) |
| Photomultiplier Tube | Hamamatsu R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PF5 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Discharge | Gravity-driven (Static) |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% for representative elements (As, Sb, Bi, Hg) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL for As, Sb, Bi |
| Photomultiplier Tube (PMT) | R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C |
| [Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Gravity-driven (Static) |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% for As, Sb, Bi, Hg |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL for As, Sb, Bi |
| Photomultiplier Tube (PMT) | Hamamatsu R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C] |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SA7/5 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Pneumatic Flow Injection System (replaces peristaltic pump) |
| Waste Disposal | Gravity-driven dual-port drainage |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sb |
| RSD | ≤1.0% (at 0.01 ng/mL for As, Sb, Bi |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As/Sb/Bi ≤ 0.01 ng/mL |
| PMT Spectral Range | Hamamatsu R7154, 160–320 nm |
| Atomizer Temperature Control | Ambient to 100 °C, adjustable in 0.1 °C increments |
| UV Digestion Cell | Quartz plate-type flow-through reactor with high UV photon utilization |
| Dual-Channel Waste Separation | Organic and inorganic waste streams isolated via dedicated tubing paths |
| Certified Performance Data Source | Public Service Platform for Enterprise Standard Information (China) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Solid Sample Testing Solution |
| Price Range | USD 14,000 – 21,000 (FOB) |
| Optical Architecture | Dual-Wavelength Configuration |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning Mode | Automatic |
| Stray Light | < 0.0004% (4 × 10⁻⁴ %) |
| Compatible Accessories | 150 mm Integrating Sphere (Standard), 60 mm Integrating Sphere (Standard), Eyewear-Specific Measurement Fixture |
| Sample Types | Opaque/Translucent Solids, Powders, Turbid Liquids |
| Measurement Modes | Diffuse Reflectance, Specular Reflectance, Total Transmittance, Diffuse Transmittance |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | T400 / T500 |
| Price Range | USD 1,400 – 4,200 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1100 nm (T400) / 190–1100 nm (T500) |
| Wavelength Accuracy | ±0.2 nm (T400) / ±0.1 nm (T500) |
| Wavelength Repeatability | ≤0.4 nm (T400) / ≤0.2 nm (T500) |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05%T at 360 nm (T400) / ≤0.05%T at 220 nm (T500) |
| Wavelength Scanning Speed | 2500 nm/min |
| Wavelength Setting Speed | 7000 nm/min |
| Dimensions (W×D×H) | 470 × 400 × 210 mm |
| Weight | 11 kg |
| Display | 7-inch Color Touchscreen |
| Data Export | USB Flash Drive Support |
| Sample Compartment | Open-Design with Integrated Cuvette Storage Rack |
| Software Interface | PC-Connectable Workstation with GLP Compliance Features |
| Firmware Upgradability | Over-the-Air (OTA) for Application Module Expansion (e.g., Protein Quantitation, Pesticide Residue Analysis, Water Quality Testing) |
