Spectroscopy Instruments
Filter
Showing 1651–1680 of 2629 results
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model Variants | TR555, TR557, TR777, DM55, DM77 |
| Spectral Range | 200 nm – 2.2 µm |
| Resolution (Additive Mode) | up to 0.13 cm⁻¹ (TR777) |
| Resolution (Subtractive Mode) | up to 0.4 cm⁻¹ |
| Stray Light Rejection | <1×10⁻⁶ (enabling Raman measurements within 5 cm⁻¹ of Rayleigh line) |
| Focal Length Options | 500 mm, 750 mm, 1000 mm, 1500 mm, 1750 mm, 2250 mm |
| Aperture Ratio | f/6.5 – f/9.7 |
| Grating Compatibility | Up to 1800 grooves/mm |
| Operating Modes | Additive (high-resolution), Subtractive (ultra-low stray light), Independent Dual/Triple Stage |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Process Guardian™ |
| Instrument Type | In-line Raman Spectrometer |
| Laser Wavelength | 785 nm |
| Enclosure | 19-inch rack-mount industrial chassis |
| Control Architecture | Embedded real-time system with integrated display and HMI |
| Fiber Interface | FC/PC dual-fiber connector |
| Channel Expansion | Up to 8 channels via multiplexer integration |
| Safety Features | Laser fiber break detection, emergency stop interface |
| Optical Technology | HTVS™ (High-Throughput Virtual Slit) spectrograph |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant data handling, ATEX/IECEx-certified options available for hazardous areas |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | AtmosFIRair |
| Instrument Type | Portable FTIR Spectrometer |
| Wavenumber Range | 485–8500 cm⁻¹ |
| Resolution Options | 1, 2, 4, or 8 cm⁻¹ |
| Scan Speed | Up to 1 spectrum per second (resolution-dependent) |
| Signal-to-Noise Ratio | >20,000:1 (peak-to-peak, 1-min acquisition), >120,000:1 (RMS, 1-min acquisition) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Brand | PSC |
|---|---|
| Origin | USA |
| Model | mIRage |
| Instrument Type | Laboratory Benchtop System |
| Spectral Range | IR (3600–800 cm⁻¹), Raman (3900–200 cm⁻¹) |
| Spatial Resolution | ~500 nm |
| Measurement Mode | Non-contact, Reflection-Based Optical Photothermal Infrared (O-PTIR) |
| Compliance | Fully Compatible with ASTM E1252, ISO 18387, USP <1119>, FDA 21 CFR Part 11 (via optional audit-trail software module) |
| Software Platform | mIRage Pro v4.2 with GLP/GMP-ready data integrity controls |
| Brand | PSC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | mIRage-LS |
| Instrument Category | Laser-Based Infrared Spectrometer |
| Instrument Type | Laboratory Benchtop System |
| Wavenumber Range | 3600–800 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Brand | PTT-Kagaku Analys |
|---|---|
| Origin | Taiwan |
| Model | MRIX |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 90–3500 cm⁻¹ |
| Spectral Resolution | Standard 2.0 cm⁻¹ |
| Spatial Resolution | 1 µm |
| Minimum Wavenumber | 90 cm⁻¹ |
| Spectral Reproducibility | <1 cm⁻¹ |
| Excitation Wavelengths | 488 nm / 532 nm / 633 nm / 785 nm |
| Objective Magnifications | 10× / 50× / 100× |
| Weight | 4 kg |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Rotating Disc Electrode (RDE) Atomic Emission Spectrometer |
| Sample Introduction | Direct liquid introduction |
| Waste Disposal | Rear exhaust configuration |
| Atomization Mode | Vapor generation / Hydride generation |
| Detectable Elements | Al, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce |
| Detection Limit | ≤1 ppb (μg/L) for most elements |
| Precision | RSD ≤1.5% |
| Stability | RSD ≤2.0% |
| Linear Dynamic Range | 5 orders of magnitude |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (±0.05%) |
| RF Power Output | 800–1600 W (±0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Minimum Sample Volume | >1 mL |
| Operating Temperature | 20–45 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Software | PICP-V2.1 multi-language platform (CN/EN/KO/JP), compliant with ASTM D6595, D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | PULUODY |
|---|---|
| Model | P-ICP-II |
| Origin | Shaanxi, China |
| Detection Principle | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (stability ≤0.05%) |
| RF Power Output | 800–1600 W (stability ≤0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Required | >1 mL |
| Operating Temperature | 20–45 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Elemental Detection Capability | ≥61 elements |
| Detection Limit | down to 1 ppb (µg/L) for most metals |
| Linear Dynamic Range | 5 orders of magnitude |
| Analysis Speed | ≥4 elements per minute |
| Precision (RSD) | ≤1.5% |
| Stability (RSD) | ≤2.0% |
| Accuracy | ±3% (method-dependent) |
| Compliance Standards | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Multi-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Direct Nebulization |
| Waste Disposal | Rear Exhaust Design |
| Gas Flow Control | Rotameter-Based Pneumatic System |
| Detectable Elements | Al, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce |
| Relative Standard Deviation (RSD) | <1% |
| Linear Dynamic Range | 5 orders of magnitude (0.01–10,000 µg/L) |
| Detection Limits | Sub-ppb (≤0.01 µg/L) for most elements |
| Photomultiplier Tube Wavelength Range | 200–1000 nm |
| Atomizer Temperature Control Range | Ambient to 45 °C |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (stability ≤0.05%) |
| RF Power Output | 800–1600 W (stability ≤0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Requirement | >1 mL |
| Operating Temperature | 15–45 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 185–900 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm) |
| Wavelength Repeatability | ≤0.05 nm (at D₂ line, 656.1 nm) |
| Spectral Bandwidth | Continuously Adjustable from 0.1 to 5.0 nm |
| Stray Light | ≤0.00004%T (NaI, 220 nm) |
| Stray Light | ≤0.00002%T (NaNO₂, 360 nm) |
| Photometric Range | –8 to +8 Abs |
| Baseline Flatness | ±0.0005 Abs |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (>1.0 Abs) |
| Photometric Repeatability | ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs), ≤0.1%T (>1.0 Abs) |
| Drift | ≤0.1%T/h |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TAS-986 |
| Pricing | Upon Request |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TU-1901 / TU-1900 |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190 nm – 900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.5 nm, 1.0 nm, 2.0 nm, 5.0 nm |
| Stray Light | ≤0.01%T at 220 nm (NaI), ≤0.05%T at 360 nm (NaNO₂) |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (0–100%T) |
| Photometric Range | –4.0 to +4.0 Abs |
| Baseline Flatness | ±0.001 Abs |
| Baseline Drift | 0.0004 Abs/h (at 500 nm, 0 Abs, after 2 h warm-up) |
| Photometric Noise | ±0.0004 Abs |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | Continuously Variable from 0.1 to 5.0 nm (0.1 nm increments) |
| Stray Light | ≤0.01% T at 220 nm (NaI), ≤0.05% T at 360 nm (NaNO₂) |
| Baseline Flatness | ±0.001 Abs |
| Drift | ≤0.1%/h |
| Dimensions | 610 × 570 × 300 mm |
| Weight | 39 kg |
| Brand | Ocean Insight |
|---|---|
| Origin | USA |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | Configurable from 185–1100 nm |
| Resolution | 18-bit ADC |
| Peak Quantum Efficiency | 90% |
| Signal-to-Noise Ratio | 1000:1 (full well, single acquisition) |
| Dynamic Range | 85,000 (typical, at full well capacity) |
| Stray Light | <0.08% at 600 nm |
| Cooling | Thermoelectrically cooled to –15 °C (stabilized ±0.1 °C) |
| Onboard Memory | 15,000 spectra buffer |
| Interface | USB 2.0 / USB 3.0 compatible |
| Slit Options | 5–200 µm (interchangeable) |
| Grating Options | Multiple groove densities and blaze wavelengths available |
| Internal Shutter | Optional for dark current optimization |
| Brand | Ocean Insight |
|---|---|
| Origin | USA (Manufactured in Orlando, FL) |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | Configurable from 185–1100 nm |
| Resolution | 18-bit digitization |
| Peak Quantum Efficiency | 90% |
| Signal-to-Noise Ratio | 1000:1 (full well, single acquisition) |
| Dynamic Range | 85,000:1 (typical, with on-board averaging) |
| Stray Light | <0.08% at 600 nm |
| Onboard Memory Buffer | 15 MB |
| Brand | Qilin |
|---|---|
| Model | QL-5800A |
| Instrument Type | Floor-standing |
| Excitation Method | Spark discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 130–600 nm |
| Number of Channels | 32 |
| Operating Environment | Argon-purged optical chamber |
| Optical Stability | Thermostatically controlled at 38 °C ±0.2 °C |
| Dimensions (L×W×H) | 1120 × 750 × 920 mm |
| Net Weight | 266 kg |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | QL-5800A |
| Instrument Type | Floor-standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 130–600 nm |
| Number of Analytical Channels | 32 |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QL-5800E |
| Price | USD 23,500 (FOB Nanjing) |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | High-Performance CCD Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Spectral Channels | 60 |
| Optical System | Paschen-Runge Mount with Vacuum-Enclosed Roland Circle |
| Light Source | Digital Plasma Spark Source with High-Energy Pre-Ignition (HEPS) |
| Discharge Frequency | 100–1000 Hz |
| Power Supply | AC 220 V, 50/60 Hz, 1000 W |
| Dimensions (W×D×H) | 780 × 565 × 360 mm |
| Weight | 78 kg |
| Typical Analysis Time | ~20 s per sample |
| Electrode Material | Tungsten Jet Electrode |
| Inter-Electrode Gap | 4 mm |
| Vacuum System | Multi-Stage Oil-Backstream Prevention with Differential Pressure Valve and In-Line Oil Trap |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | QL-5800E |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CCD Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Detection Channels | 60 |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | QL-5800E |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | High-Performance CMOS Array (CCD-compatible architecture) |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Detection Channels | 60 |
| Power Supply | AC 220 V, 50/60 Hz, 1000 W |
| Dimensions (W×D×H) | 780 × 565 × 360 mm |
| Weight | 78 kg |
| Typical Analysis Time | ~20 s per sample |
| Inter-electrode Gap | 4 mm |
| Electrode Material | Tungsten |
| Vacuum System | Integrated oil-free vacuum with differential pressure valve and multi-stage oil-trap protection |
| [Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector | CCD Array |
| Focal Length | 400 mm |
| Groove Density | 2400 lines/mm |
| Wavelength Range | 130–900 nm |
| Number of Channels | 60] |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-5800E |
| Instrument Type | Benchtop OES |
| Excitation Source | Spark Discharge |
| Detector | CCD Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Detection Channels | 60 |
| Optical System | Paschen–Runge Mount with Vacuum-Enclosed Roland Circle |
| Base Materials Supported | Fe, Cu, Al, Ni, Co, Mg, Ti, Zn, Pb, Sn, Ag |
| Analysis Time | ~20 s per sample |
| Dimensions | 780 × 565 × 360 mm |
| Weight | 78 kg |
| Power Supply | AC 220 V, 50/60 Hz, 1000 W |
| Brand | QL |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Benchtop |
| Excitation Mode | Spark |
| Detector | High-Performance CMOS Array (CCD-compatible architecture) |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Simultaneous Channels | 60 |
| Optical System | Paschen-Runge Mount with Vacuum-Enclosed Roland Circle |
| Light Source | Digital Plasma Spark Source with High-Energy Pre-Ignition (HEPS) |
| Discharge Frequency | 100–1000 Hz |
| Max Discharge Current | 500 A |
| Vacuum System | Multi-Stage Oil-Backstream Prevention with Differential Pressure Valve & In-Line Oil Trap |
| Analysis Gap | 4 mm |
| Electrode Material | Tungsten Jet Electrode |
| Argon Consumption | Optimized via Integrated Pneumatic Module |
| Data Interface | Gigabit Ethernet (TCP/IP) |
| Dimensions (W×D×H) | 780 × 565 × 360 mm |
| Weight | 78 kg |
| Typical Analysis Time | ~20 s per sample |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R-3000 / R-3000QE |
| Price | Upon Request |
| Brand | Endress+Hauser |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RAMANRXN2 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Excitation Wavelength Options | 532 nm, 785 nm, or 1000 nm |
| Channel Configuration | Single-Channel (Standard), Optional 4-Channel Multiplexing |
| Probe Compatibility | Rxn-10 (with accessory optics), Rxn-30, Rxn-40, Rxn-41, Rxn-45, Rxn-46 |
| Hazardous Area Certifications | ATEX, IECEx, North American Class I Div 1/2, Class II Div 1/2 |
| Installation Form Factor | Benchtop or Mobile Cart-Mounted |
| Regulatory Compliance | Designed for cGMP/GLP environments, supports FDA 21 CFR Part 11–compliant audit trails when integrated with validated software platforms |
| Software Interface | Embedded touchscreen control with optional remote web-based access via Ethernet/Wi-Fi |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Nanophoton RAMANdrive |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm (X), 500 nm (Y), 1 µm (Z) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | RamSPEC-VUV-0.3-0.6 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 140–550 nm |
| Spectral Resolution | 0.1 nm |
| Spatial Resolution | 1 µm |
| Minimum Raman Shift | 0 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.01 cm⁻¹ |
| Brand | Rayleigh |
|---|---|
| Origin | Beijing, China |
| Model | WQF-600N |
| Instrument Principle | Fourier Transform (FT) |
| Wavenumber Range | 3300–10000 cm⁻¹ |
| Spectral Resolution | < 4 cm⁻¹ |
| Wavenumber Accuracy | Better than half the set resolution |
| Transmittance Repeatability | ±0.5% T |
| Signal-to-Noise Ratio (S/N) | >10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹) |
| Beam Splitter | CaF₂ |
| Detector Options | DTGS (PbS, InGaAs optional) |
| Light Source | Air-cooled tungsten-halogen lamp |
| Data System | PC-based with Windows OS |
| Software | Full-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099 |
| Brand | Rayscience |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | THz |
| Spectral Range | 0.1–4.0 THz |
| Spectral Resolution | <50 GHz (after FFT) |
| Dynamic Range | >70 dB (at peak) |
| Operation Modes | Transmission or Reflection |
| Sample-to-Source Distance | 1–40 cm |
| Emitter | Photoconductive Antenna |
| Detector | ZnTe Electro-Optic Crystal |
| Control Software | LabVIEW-based GUI |
| Interface | USB 2.0 & Bluetooth |
| Dimensions | 10.5" × 6.25" × 2.75" (267 × 159 × 70 mm) |
| Weight | <4.2 lbs (1.9 kg) |
| Brand | Redback Systems |
|---|---|
| Origin | Australia |
| Model | RS10k |
| Spectral Range | 450–1030 nm |
| Resolution (R = λ/Δλ) | 17,000–10,000 |
| Wavelength Stability | <10 pm/°C |
| Wavelength Accuracy | <50 pm |
| SNR | 350:1 |
| Detector | Uncooled Sony STARVIS CMOS |
| Pixel Read Noise | <2 e⁻/pixel (rms) |
| Dark Current | <0.5 e⁻/pixel/s |
| Exposure Time | 1 ms–60 s |
| Data Acquisition Rate | Up to 10 Hz |
| Input Interface | Single-mode fiber, FC/PC |
| Dimensions (H×W×L) | 40 mm × 78 mm × 120 mm |
| Polarization Independence | Yes |
| Software | RedSolve (license-free) |
| API | Python-based RedMote SDK |