Spectroscopy Instruments
Filter
Showing 1531–1560 of 2629 results
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | TAP-02 |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Temperature Range | Ambient to 300°C (573 K) |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Stability | ±0.2°C (40–300°C) |
| Programmable Segments | 8-step ramp/soak |
| Heating Rate | >20°C/min |
| Cooling Design | Active rapid cooling |
| Operating Environment | Ambient pressure with controllable gas flow (N₂, O₂, Ar, etc.) |
| Power Supply | AC 220 V, 5 A, 500 W |
| Compatibility | Modular integration with Hitachi F-4500/F-7000/F-4600/F-2700 |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Price Range | USD 1,400 – 140,000 |
| Brand | Paeonia Innovations |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Instrument Type | Online |
| Wavenumber Range | 900–1800 cm⁻¹ |
| Dimensions | 50 × 55 × 60 mm |
| Weight | 450 g |
| Response Time | 0.3 s |
| Operating Pressure | 0–5 bar |
| Operating Temperature | −15 °C to +60 °C |
| Flow Path Fitting | 1/8″ NPT or Swagelok |
| Power Supply | 5 V DC via USB-C |
| Software Platform | Windows 10 & 11 Native Application for Real-Time Data Acquisition and Instrument Control |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Expert |
| Protection Rating | IP67 |
| Wavelengths | 430 nm, 465 nm, 530 nm, 575 nm, 620 nm (auto-selected per method) |
| Display | 16:9 full-color touchscreen, 800 × 480 px resolution |
| Photometric Accuracy | ±1% T |
| Wavelength Accuracy | ±2 nm |
| Memory Capacity | 1000 test records with timestamp, sample ID, operator info, dilution factor, and method metadata |
| Preloaded Calibration Curves | >100 (for chlorine, COD, ammonia-N, total phosphorus, total nitrogen, hardness, color, heavy metals, etc.) |
| Cuvette Compatibility | 12 mm and 25 mm round glass or plastic cuvettes |
| Power Supply | 6 × AA batteries (≈5000 measurements per charge) or AC adapter |
| Data Interface | Waterproof USB port compliant with USB 2.0 |
| Operating Languages | English, Chinese, Spanish, French, German, Portuguese |
| Compliance | Designed to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 365.2, USP <643>, and EN ISO 6226 for photometric water analysis methods |
| Brand | Other Brands |
|---|---|
| Origin | Domestic |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | PEM Photoelastic Modulator (Domestic) |
| Price | Upon Request |
| Brand | PerfectLight |
|---|---|
| Model | DT-Series (e.g., DT 350, DT 405, DT 550, etc.) |
| Substrate Material | Fused Silica |
| Diameter | 63 mm |
| Clear Aperture | >57 mm |
| Center Wavelength Range | 320–700 nm (UV-Vis) |
| Full Width at Half Maximum (FWHM) | 20 nm ±3 nm |
| Blocking Range | OD ≥4 from 200–1200 nm (typical) |
| Surface Quality | 20–10 scratch-dig |
| Parallelism | <3 arcsec |
| Transmission Peak | >85% (typical) |
| Operating Temperature | –20 °C to +70 °C |
| Compliance | ISO 9001-manufactured, RoHS-compliant |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | UVref |
| Filter Type | Cut-On / Cut-Off, Bandpass, and Narrowband |
| Substrate Material | Fused Silica (Quartz) |
| Diameter | 63 mm |
| Clear Aperture | >57 mm |
| Spectral Range | 320–2500 nm |
| Optical Density (OD) @ Blocking Region | ≥4.0 (typ.) |
| Surface Quality | 20–10 scratch-dig |
| Parallelism | <3 arcsec |
| Coating Type | Hard Dielectric Multilayer |
| Incident Angle | 0° ± 2° (for specified spectral performance) |
| Compliance | ISO 9001-manufactured optical components |
| Application Domain | Laboratory-based NIR, UV-Vis, and FT-NIR spectroscopy systems |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Custom 2 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Custom 9 |
| Pricing | Upon Request |
| Detection Principle | Laser Raman Spectroscopy |
| Target Analytes | Monoethanolamine (MEA), Diethanolamine (DEA) |
| Concentration Range | 0–55% (w/w) |
| Accuracy | ≤ ±1% FS |
| Response Time | ≤ 30 s |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 15–85% RH |
| Probe Configuration | In-situ or Extractive |
| System Architecture | Modular (Separated Spectrometer Unit & Immersion Probe) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PR-GLRSA |
| Quotation | Upon Request |
| Detection Channels | 2 (simultaneous) |
| Target Gases | H₂, CO, C₃H₈, C₃H₆ |
| Concentration Ranges | H₂: 0–50% vol, CO: 0–10% vol, C₃H₈: 0–50% vol, C₃H₆: 0–80% vol |
| Accuracy | ≤ ±3% FS |
| Response Time | ≤ 30 s |
| Explosion Protection | Ex db ec ib pzc II C T3 Gc (Positive-Pressure Purged & Pressurized) |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V / 50 Hz, ≤ 800 W (host only) |
| Purge Gas | Clean, oil-free, dry, particle-free compressed air, 0.4–0.8 MPa |
| Brand | PERIC |
|---|---|
| Model | PR-LM |
| Type | Portable / Handheld Raman Spectrometer |
| Origin | Hebei, China |
| Manufacturer | PERIC Instrument Co., Ltd. |
| Measurement Range | 0–100% (v/v) |
| Detection Limit | 1 µmol/mol |
| Accuracy | ±0.1% (full scale) |
| Analysis Time | 1–300 s (user-configurable) |
| Sample Inlet | Integrated diaphragm pump |
| Dimensions (L×W×H) | 557 × 420 × 330 mm |
| Weight | <23 kg |
| Target Gases | H₂, N₂, O₂, CO, CO₂, CH₄, NH₃, H₂O, H₂S, C₂H₂, C₂H₄, C₂H₆, C₃H₆, and other hydrocarbons and inorganic gases |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Region | Domestic (China) |
| Model | PR-LR |
| Pricing | Upon Request |
| Gas Detection Range | N₂, O₂, H₂, CH₄, CO, CO₂, C₂H₆, C₂H₄, C₂H₂, C₃H₈, C₃H₆, C₄H₁₀, NO, NO₂, SO₂, H₂S |
| Accuracy | ≤±1% FS for components >1% full scale |
| Resolution | ≤0.01% (for >1% FS) |
| Analysis Time | 10–30 s (adjustable) |
| Laser Wavelength | 532 nm |
| Laser Linewidth | ≤0.1 nm |
| Spectral Range | 0–4200 cm⁻¹ |
| Spectral Resolution | 5 cm⁻¹ |
| Power Supply | 220 VAC, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Temperature | 10–35 °C |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PR-RM |
| Instrument Type | Online Raman Spectrometer |
| Gas Species | Benzene, Nitrogen, Hydrogen, Carbon Dioxide, Carbon Monoxide, Carbonyl Sulfide, Hydrogen Sulfide, Oxygen, Methane |
| Range | 0–100 %vol |
| Detection Limit | ≤50–100 ppm (gas-dependent) |
| Accuracy | ≤2 %FS |
| Measurement Cycle | 1–30 s (adjustable) |
| Sampling Method | Pump-aspirated with integrated pre-treatment |
| Environmental Robustness | Rated for high-pressure, high-temperature, high-humidity, high-dust, and hazardous-area operation |
| Maintenance | Consumable-free design |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 210VGP |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu ≤ 0.005 mg/L |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±0.1 nm |
| Slit Widths | 0.2 / 0.7 / 2.0 nm |
| Background Correction | Deuterium Lamp (190–350 nm) and Self-Reversal HCL (190–900 nm) |
| Atomization | Air/Acetylene, N₂O/Acetylene, Ar/H₂ premixed flame |
| Furnace Max Temp | 3000 °C in <1 s |
| Data Interface | RS-232C, IEEE-488 (GPIB), Parallel Printer Port |
| Dimensions (L×W×H) | 991 × 279 × 305 mm |
| Net Weight | 23 kg |
| Brand | PerkinElmer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Mode Flame/GF-AAS |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + AC Zeeman |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Flame (Cu): ≤0.02 µg/mL |
| GF-AAS (Cd) | ≤5.0×10⁻¹³ g |
| Precision (RSD) | Flame (Cu): ≤0.45% |
| GF-AAS (Cd) | ≤3.0% |
| Detection Limit | Flame (Cu): ≤0.003 µg/mL |
| GF-AAS (Cd) | ≤1.0×10⁻¹² g |
| Baseline Stability | ≤0.002 A/30 min (static) |
| Lamp Turret | 8-position Auto-rotating |
| Graphite Furnace | Transversely Heated |
| Magnetic Field | AC Zeeman, 0.6–1.1 T adjustable in 0.1 T increments |
| Optional Features | Integrated Graphite Furnace Viewing System |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 600 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Resolution | 0.3 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu ≤ 0.006 mg/L |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 800 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Automatic Deuterium/Hollow Cathode Lamp (D₂/HCL) |
| Spectral Resolution | 0.3 nm |
| Sensitivity | ≥ 0.3 A for 5 ppm Cu solution |
| Precision (RSD) | < 0.3% |
| Detection Limit (Cu) | ≤ 0.006 mg/L |
| Compliance | ASTM E1921, ISO 7185, USP <731>, FDA 21 CFR Part 11–ready software environment |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 200 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Gas Consumption | <8 L/min Ar (typical operational mode) |
| Startup Time | <5 minutes from cold start to analysis-ready |
| Dual-View Capability | Axial and Radial Simultaneous Observation without Sensitivity Loss |
| Linear Dynamic Range | Up to 9 orders of magnitude |
| Detector | Back-Illuminated CCD with On-Chip Background Correction |
| Plasma Technology | Flat Plate™ RF Generator and PlasmaShear™ Air-Based Tail Flame Elimination |
| Torch Orientation | Vertical, Tool-Free Adjustable Base with Interchangeable Injector Tubes |
| Software Platform | Syngistix for ICP-OES (21 CFR Part 11 Compliant) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Argon Consumption | <10 L/min (typical operational mode) |
| Plasma Orientation | Dual-View (Axial & Radial) |
| Plasma Technology | Flat Plasma™ |
| Background Correction | Real-Time Synchronous Background Correction |
| Detection Capability | Multi-element, simultaneous quantitative analysis of metals and some non-metals in liquid samples |
| Software Platform | Syngistix™ for ICP-OES |
| Brand | PerkinElmer |
|---|---|
| Model | Avio 550 |
| Origin | Imported |
| Configuration | Refurbished Unit |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Plasma Observation | Dual-view (Axial and Radial) |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Nebulization System | 4-channel, 12-roller peristaltic pump |
| Plasma Torch Design | Vertical, tool-free, maintenance-free torch with integrated tail-flame cutoff |
| Argon Consumption | Ultra-low |
| Diagnostic Capability | Real-time plasma imaging via integrated color plasma camera |
| Data Acquisition | Universal Data Acquisition (UDA) — full-wavelength, simultaneous, time-resolved detection |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio 550/560 |
| Pricing | Upon Request |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Configuration | Dual-View (Axial and Radial) |
| Detection Technology | Solid-State CCD Detector Array |
| Gas Consumption | Ultra-Low Argon Flow (<10 L/min typical plasma gas) |
| Torch Design | Vertical, Tool-Free, Maintenance-Free Plasma Torch with Integrated Tail-Flame Suppression |
| Optical System | Flat-Field Echelle Spectrometer with UV-Visible Wavelength Coverage (165–900 nm) |
| Pump System | 4-Channel, 12-Roller Peristaltic Pump |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Camera Integration | Integrated Color Plasma Torch Imaging System for Real-Time Torch & Injector Monitoring |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio® 550 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Orientation | Vertical Torch Configuration |
| Software Platform | Syngistix™ for ICP |
| Sample Introduction System | Scott/Cross-Flow Nebulizer with Cyclonic Spray Chamber |
| Optional Capability | HF-Compatible Sample Handling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Avio 200 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 0.003 ng/mL (typical, e.g., Mg II 279.553 nm) |
| Precision (RSD) | ≤1% at 1 µg/L |
| Stability (RSD over 4h) | ≤1% |
| Wavelength Range | 110–900 nm |
| Optical Resolution | ≤0.007 nm (FWHM at 200 nm) |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 6500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | >750:1 (RMS) |
| Dispersion Element | Grating |
| Light Source | Pulsed Xenon Lamp |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 8500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | 4000:1 (RMS), 1000:1 (Peak-to-Peak) |
| Dispersion Element | Holographic Grating |
| Excitation Source | Continuous Xenon Arc Lamp |
| Maximum Scan Speed | 60,000 nm/min |
| Footprint | 66 cm (26 in) width |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 7000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Distribution Channel | Authorized Third-Party Reseller |
| Import Status | Imported Instrument |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 1050+ |
| Optical Design | Double-beam |
| Detector Type | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–3300 nm |
| Wavelength Accuracy | ±0.025 nm (UV-Vis), ±0.02 nm (NIR) |
| Automation | Motorized wavelength scanning and accessory control |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 265 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | <0.03% T at 340 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 365 |
| Instrument Configuration | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | Selectable (0.5, 1, 2, 5, or 20 nm) |
| Wavelength Accuracy | ±0.1 nm |
| Stray Light | <0.02% T at 340 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Configuration | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Spectral Bandwidth | 0.5 nm to 20 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.02 nm |
| Stray Light | <0.00004% T at 220 nm and 340 nm |
| Absorbance Range | Up to 4.0 A |
| Automation Level | Fully Automated Wavelength Scanning & Parameter Control |
| Compliance | ASTM E275, ISO 9001, USP <857>, FDA 21 CFR Part 11 Ready |
